The
IQ Hardwire 16-S
offers a cost effective way of integrating hardwired security zones
with the IQ Panel. It includes backup battery charging, an onboard siren relay and
features end-of-line resistor learning, making rewiring different resistor values a thing of
the past. It also supports magnetic contacts and powered zones such as motion sensors
and glass break detectors.
Note: Not for use with life safety devices, such as Smoke or CO detectors
QUICK GUIDE
1.
Mount the IQ Hardwire 16-S vertically in your desired location.
2.
Install provided antenna into the “ANT” terminal at the top of the unit free from
obstructions
3.
Wire all hardwired sensors/leads into the terminals marked “Zone 1-16”
a.
All sensors must have a resistor installed between 1k-10k Ohm in either the N/O or N/C position
b.
Wire the Positive and Negative leads from powered devices, such as motion sensors and glass break sensors,
into the “AUX” (+) and “GND” (-) terminals to power the device. (see wiring diagram)
c.
Wire the tamper switch into the tamper terminals. (optional)
d.
Wire optional hardwired siren (60VDC/1A Max, see wiring diagram)
4.
If learning the IQ Hardwire 16-S into the Panel for supervision, plug in a 5Ah Max backup
battery with included battery leads (battery not included).
5.
With provided transformer, connect power supply leads into the terminals marked +16.0V
GND then plug in the IQ Hardwire 16-S power supply. (IMPORTANT: dashed wire is positive)
INFORMATION
TECHNICAL SPECIFICATIONS
Input Voltage:
16.0VDC Plug-In Transformer
Backup Battery:
12VDC 5AH Max (optional)
Dimensions:
5.5” X 3.5”
Operating Temperature:
32 to 122F (0 to 50C)
Humidity:
95% RH Max
EOL Supervision:
1K to 10K Ohm
Input Zones:
16 (must have resistor)
Zone Type:
N/O or N/C compatible
Auxiliary Voltage Output:
12VDC @ 500mA
Tamper Zone:
Optional zone input for tamper
Relay Contact:
60VDC/1A Max drives siren or
other device
Document #: IQHW16SQG
Revision Date: 7/31/17
Qolsys Part #: QS7131-840
STEP 1: INSTALL THE HARDWARE
IN THE BOX
IQ Hardwire 16-S
Cover
Antenna
Power Supply
4 Screws
16 Resistors (3K)
Battery cables
If mounting inside a metal
can, the antenna must extend
outside the enclosure to
ensure RF communication
Confidential &
Proprietary.
Made in Taiwan.
Full installation
manual and other
documentation
available at
Qolsys.com.
Trip the module
by “shorting” the
“Tamper”
terminals on the
module with a
piece of wire.
STEP 2: PAIR THE IQ HARDWIRE 16 WITH THE IQ PANEL
Note: This allows the IQ Panel to supervise the IQ
Hardwire battery, power status, aux power out, &
tamper
Press and hold “EOL
Learn” for 1-2 secs.
(
all Zone LED’s
flash and then
turn off)
EOL Cal LED
will turn ON.
This puts the
module into
“Enroll Mode”.
Follow the onscreen
prompts on the IQ
Panel to finish the
enrolling process. The
IQ Hardwire 16-S
should be learned in as
a “Hardwire Translator”
Page
of
Qolsys Confidential and Proprietary.
1
2
Place your panel in “auto learn”
mode QUICK GUIDE
Page
of
Qolsys Confidential and Proprietary.
2
2
TROUBLESHOOTING
EOL LEARN Button:
To enter and exit “Enroll Mode”
and calibrate resistor values
MEMORY RESET Button:

Clears memory and
resets the device to factory defaults
PROCESSOR LED:

Flashes during normal operation
RF XMIT LED:

Flashes when RF transmission is being
sent

EOL CAL LED:

Flashes when EOL resistors are not
calibrated or when no zones have been learned in. ON
when device is in “Enroll Mode”. OFF when device is in
“Normal Operation Mode”

ZONE LED:

Flashes several times when EOL Cal
button is pressed. OFF while in “Enroll Mode” unless a
zone has been learned in or tripped, then ON. OFF while
in “Normal Operation Mode” unless a zone is open, then
ON.

How to Clear the Memory:
Power down the unit by
unplugging the battery leads and the power supply. Hold
down “Memory Reset” for 3 seconds while re-applying
power to the device. Processor, RF Xmit and EOL Cal
LED’s will begin to flash indicating that the module has
been reset.
NEED MORE HELP?
CONTACT TECH SUPPORT
(855) 4-QOLSYS
TechSupport@Qolsys.com
?
Trip (Open/Close)
each hardwired zone
one at a time
Once all desired zones have been
learned, press the “EOL Learn”
button to exit “Enroll Mode”. The
EOL Cal LED will turn OFF
indicating you are no longer in
“Enroll Mode” and all zone LED’s
will turn OFF.
When a sensor has been
tripped, the resistor value is
calibrated and the Zone LED
will illuminate and stay on
until you exit enroll mode.
STEP 3: PAIRING INDIVIDUAL ZONES/SENSORS
Customize sensor type
and settings as desired.
Repeat for each zone.
The IQ Panel will “chime”
indicating it has found a
new sensor. Touch
“Okay” to proceed.
WIRING DIAGRAM
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute
interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.
FCC ID: 2ABBZ-RF-CHW-ITI-S
IC: 11817A-RF
CHWITIS


Uploaded