Qolsys IQ Hardwire 8-S - Quick Install Guide
Related Products
Related Categories
Document Transcript
1.
Mount the IQ Hardwire 8-S vertically in your desired location.
2.
Install provided antenna into the “ANT” terminal at the top of the unit free from
obstructions
3.
Wire all hardwired sensors/leads into the terminals marked “Zone 1-8”
a.
All sensors must have a resistor installed between 1k-10k Ohm in either the N/O or N/C position
4.
Plug in a 5Ah Max backup battery with included battery leads (battery not included).
5.
With provided transformer, connect power supply leads into the terminals marked +16.0V
GND then plug in the IQ Hardwire 8-S power supply. (IMPORTANT: dashed wire is positive)
INFORMATION
The
IQ Hardwire 8-S
offers a cost effective way of integrating hardwired security zones
with the IQ Panel. It includes backup battery charging and features end-of-line resistor
learning, making rewiring different resistor values a thing of the past.
Note: Not for use with life safety devices, such as Smoke or CO detectors
TECHNICAL SPECIFICATIONS
Input Voltage:
16.0VDC Plug-In Transformer
Backup Battery:
12VDC 5AH Max (optional)
Dimensions:
5.5” X 3.5”
Operating Temperature:
32 to 122F (0 to 50C)
Humidity:
95% RH Max
EOL Supervision:
1K to 10K Ohm
Input Zones:
8 (must have resistor)
Zone Type:
N/O or N/C compatible
Document #: IQHW8SQG
Revision Date: 7/31/17
Qolsys Part #: QS7130-840
STEP 1: INSTALL THE HARDWARE
IN THE BOX
IQ Hardwire 8-
S
Cover
Antenna
Power Supply
4 Screws
8 Resistors (3K)
Battery cables
If mounting inside a metal can, the
antenna must extend outside the
enclosure to ensure RF communication
QUICK GUIDE
Confidential & Proprietary.
Made in Taiwan.
Full installation manual and
other documentation
available at Qolsys.com.
STEP 2: PAIRING INDIVIDUAL ZONES/SENSORS
Press and hold “EOL Learn”
for 1-2 secs.
(
all Zone LED’s
flash and then turn off)
EOL Cal LED will turn ON.
This puts the module into
“Enroll Mode”.
Trip (Open/Close)
each hardwired zone
one at a time
The IQ Panel will “chime”
indicating it has found a
new sensor. Touch
“Okay” to proceed.
Customize sensor type
and settings as desired.
Repeat for each zone.
When a sensor has
been tripped, the
resistor value is
calibrated and the
Zone LED will
illuminate and stay
on until you exit
enroll mode.
Once all desired zones have been learned,
press the “EOL Learn” button to exit
“Enroll Mode”. The EOL Cal LED will turn
OFF indicating you
are no longer in
“Enroll Mode” and
all zone LED’s will
turn OFF.
Page
of
Qolsys Confidential and Proprietary.
1
2
8-S
HARDWIRE
8-S
HARDWIRE
8-S
HARDWIRE
Place your panel in “auto learn”
mode QUICK GUIDE
Page
of
Qolsys Confidential and Proprietary.
2
2
TROUBLESHOOTING
EOL LEARN Button:
To enter and exit “Enroll Mode” and calibrate resistor values
MEMORY RESET Button:
Clears memory and resets the device to factory defaults
PROCESSOR LED:
Flashes during normal operation
RF XMIT LED:
Flashes when RF transmission is being sent
EOL CAL LED:
Flashes when EOL resistors are not calibrated or when no zones have been learned in. ON when device is in “Enroll Mode”. OFF when
device is in “Normal Operation Mode”
ZONE LED:
Flashes several times when EOL Cal button is pressed. OFF while in “Enroll Mode” unless a zone has been learned in or tripped, then ON.
OFF while in “Normal Operation Mode” unless a zone is open, then ON.
How to Clear the Memory:
Power down the unit by unplugging the battery leads and the power supply. Hold down “Memory Reset” for 3 seconds
while re-applying power to the device. Processor, RF Xmit and EOL Cal LED’s will begin to flash indicating that the module has been reset.
NEED MORE HELP?
CONTACT TECH SUPPORT
(855) 4-QOLSYS
TechSupport@Qolsys.com
?
WIRING DIAGRAM
8-S
HARDWIRE
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute
interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.
FCC ID: 2ABBZ-RF-CHW-ITI-S
IC: 11817A-RF
CHWITIS