The sensor should be permanently mounted in a corner or on a
flat wall that is free of vibrations, at a height of 6.5 feet, using the
built-in angle mount.
•
Mount the sensor on an insulated exterior wall facing in.
•
Position the sensor to protect an area where an intruder is most
likely to walk across the detection pattern.
•
Position the sensor so it faces a solid reference point, such as a
wall.
•
If possible, mount the sensor within 100 ft of the panel. While
the transmitter may have a range of 600 ft or more out in the
open, the environment at the installation site can have a
significant effect on transmitter range. Verify actual transmitter
range for each installation.
•
Close all windows in an area with an armed motion sensor.
IQ MOTION INSTALLATION MANUAL
•
Advanced circuit technology
resulting in ultra-low power
consumption
•
40 lb. Pet immunity
•
Tamper detection/reporting
•
Rigid wall mounting for discreet
placement
•
Easy to install batteries
•
Supervisory health messaging
PRODUCT FEATURES
IQ MOTION
•
Wireless signal range: 600 ft, open air
•
Code outputs: paring, tamper, tamper restore, alarm detect motion,
alarm restore, supervisory, low battery
•
Transmitter frequency: 319.5MHZ +-15KHz
•
Transmitter bandwidth: 24KHZ
•
Modulation type: ASK-OOK
•
RF output power 91.1dBuV +/- 5% at 3m
•
Sensor Range 30 ft x 40 ft
•
Maximum Horizontal Sensing Angle 80°
•
Replace batteries every 5 years with AAA Alkaline (x2)
•
Sensor: 3.4H x 2.4W x 1.5D in.
TECHNICAL SPECIFICATIONS
STEP
1
CHOOSE
INSTALLATION
LOCATION
•
Aim the sensor at windows, fireplaces,
air conditioners, area heaters, forced
air heating vents or drapes.
•
Place the sensor in direct sunlight as
sudden changes in temperature may
trigger a false alarm.
•
Mount the sensor near duct work or
other large metallic surfaces that may
affect the RF signals.
•
Set the sensor on a shelf.
•
Mount outdoors or in a non-
temperature controlled environment.
Qolsys Inc. proprietary.
Reproduction without permission is not permitted.
LOCATION MOUNTING GUIDELINES:
DO NOT:
X
Avoid placement
looking at ceiling
fans
✓
Outside walls
pointed away from
windows are great
locations
X
Avoid
HVAC
ducts &
drapes
X
✓
Install at
6.5’ high
✓ STEP
2
REMOVE
BATTERY
TABS
STEP
4
CHOOSE
MOUNTING
TYPE
SECURE
ALL
HARDWARE
LEARN
INTO
PANEL
STEP
5
OPEN
DEVICE
CASING
STEP
3
STEP
6
Place your panel in
“autolearn" mode
Open and close the case
to “tamper” the device
Customize name and settings
as desired and and touch “ADD”
ADD
ANGLED
FLAT
ANGLED
CORNER
MOUNT AT
6.5 FEET HIGH
DO NOT USE
THESE MOUNTING
LOCATIONS
Walk test mode is activated by opening the motion detector back plate enough to release the tamper switch, then closing it again. During walk
test mode the red LED on the front of the detector will light up every time motion is detected. Use this feature to test the coverage pattern of
the protected area. The motion detector will remain in walk test mode until there is a period of one minute of inactivity, meaning that no
motion is detected for one minute, at which time it will return to normal mode.
MODES & BEHAVIORS
NORMAL MODE:
Normal mode defines the motion detector’s behavior set in which it can detect motion. It is the default state of the sensor, given no motion has
been detected. While in normal mode, a motion detector sensor can go into both sleep mode and walk test mode, as is described below.
During any given time in normal mode, the motion detector can transmit up to TWO active events. Once the first active event is sent, the
motion detector has a 4 second timeout delay before a second active event can be transmitted. After the first active event is sent, a 5 minute
timer starts; if a second active event is sent during this 5 minute period, the motion detector will go into sleep mode for the remainder of the 5
minute period. Once this 5 minute period times out, the motion detector returns to its normal behavior where it can transmit two active events.
During normal mode, a motion detector will send a supervisory heartbeat to the panel 70 minutes after the last event transmission. If the
device has been idle for 70 minutes consecutively, it will send out a heartbeat supervisory transmission.
Qolsys Inc. proprietary.
Reproduction without permission is not permitted.
SLEEP MODE:
WALK TEST MODE:
Sleep mode defines a limited period when the motion detector does not transmit any active or idle events to the panel in order to conserve
battery life.
The sleep mode timer last five minutes and starts once the first active event is sent. During this period, if a second active event is
transmitted, the motion detector will go into sleep mode until the timer finishes counting down.
PET IMMUNITY:
The IQ Motion Detector is pet immune up to 40 lbs when mounted at 6.5 feet high and angled downward. Pets must not be allowed to climb
on objects such as furniture, shelves, boxes, etc. within the field of coverage (see detection pattern on page 3 of this manual). The detector
should not be looking directly at stairs that would allow a pet to walk up them when the panel is armed. AAA Alkaline (2 per sensor)
Battery life expectancy: 5 years. (Lifetime may vary
depending on number of activations, environmental
conditions, etc.)
To replace batteries:
•
Push button on bottom of sensor and remove from
backplate.
•
Remove old batteries and replace with new ones.
•
Re-install in reverse order.
Operating Temperature: -10C~50C
Relative Humidity: 5-85%
Storage Temperature: -40-80C
ENVIRONMENTAL
Document#: IQM-IM-01-18
Revision#: 1/29/18
Issue Date: JAN 2018
Qolsys Part #: QS1200-P01
TechSupport@Qolsys.com
Qolsys Inc. proprietary.
Reproduction without permission is not permitted.
FCC ID: 2AAJXQS1200
IC: 11205A-QS1200
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute
interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.
CONTACT TECH SUPPOR
T
GOT QUESTIONS?
DETECTION PATTERN
BATTERY REPLACEMENT
TOP VIEW:
SIDE VIEW:
- Uploaded