TSB #:
221024

DATE:
10/24/22
RE:
IQ PANEL 2 & 2 PLUS - 2.7.2 SOFTWARE UPDATE
RELEASE NOTES & UPDATE INSTRUCTIONS
Release Notes:
Fixes/Improvements:

Fixed an issue where the panel could report a false AC status

Spanish / Portuguese / Turkish language improvements

Corrected an issue where HSM2108 expanders connected to an IQ Hardwire PowerG (PGxHRDW8 /
PGxWLSHW8) would not allow N/C zone configuration

KP-141/241 keypad improvements: Keypad is functioning as per the product manual when paired to IQ Panel
2/2+

Corrected an issue with PG9905 and ADC Smarter Business Temperature Monitoring (SBTM) service

Anti-Masking is now supported (On/Off) for PowerG motion sensors that support this feature

Corrected an issue where the PowerG Keypad/Siren will not function properly when enabled for all sounds in
Partition 1

Corrected an issue where Liftmaster GDO might not respond to commands properly from the Panel UI

Improved Panel camera exposure for Alarm Videos

Thermostat UI on the Panel can now show and set half degree increments (Celsius only)

Improved Corbus keypad and PowerG Keypad functionality when EN Grade 2 is enabled

Modified some sensor configurable fields to non-editable by the Master User

Added support for the KP-140 to support silent arming

New setting that when activated transmits a unique event code to the CS when the Power Down function is
used on the Panel

Improvement to keep light state in sync on the panel for the Sengled Z-Wave Bulb V11-N13

Corrected an issue where the Panel Camera and PIR cam images had an incorrect time stamp on the ADC
customer site

PowerG Photoelectric Beam Detector DQ trouble now displays on ADC as offline/malfunction

Added messaging on the Alarm.com history to show when Exit Delay is complete

Includes PowerG Modem Firmware Version 2.4.2 (V2/V3) / 2.0.16.86(V4) - Build 80.63 (V2/V3) / 82.8(V4)

Includes ADC Firmware v9.75
Update Instructions:
Compatibility Note: Your IQ Panel must be on software version 2.0.1 or higher and connected to Wi-Fi to install
this update wirelessly. Panels running 2.5.0 & 2.5.1 must be updated to 2.5.3 first, then they can be updated
directly to 2.7.2:
1- Swipe down from the top of the screen and touch “Settings"
2- Touch “Advanced Settings”

3- Enter a valid installer code (default is 1111)
TECHNICAL SERVICE BULLETIN
IQ PANEL 2 & 2 PLUS - 2.7.2 SOFTWARE UPDATE - RELEASE NOTES AND INSTRUCTIONS 4- Touch "Upgrade Software"
5 -Touch “Patch Tag” and enter the patch
iqpanel2.7.2
then touch OK

6- Touch "Upgrade Using Network" (panel must be connected to Wi-Fi).
 
Update will download and install

7- Once complete touch "OK" to reboot the panel.
 
DO NOT TOUCH THE SCREEN.

 
The update process will
take approximately 5 minutes. After the panel reboots the home screen will appear and the LED will turn green.
TECHNICAL SERVICE BULLETIN
IQ PANEL 2 & 2 PLUS - 2.7.2 SOFTWARE UPDATE - RELEASE NOTES AND INSTRUCTIONS