IQ SHOCK MINI-S INSTALLATION MANUAL

Reed Switch


Advanced accelerometer based
shock detection


3 distinct sensitivity settings


LED for easy calibration


Ultra small form factor


Easy to install batteries


Supervisory health messaging
PRODUCT FEATURES
IQ SHOCK
MINI-S
TECHNICAL SPECIFICATIONS
Qolsys Inc. proprietary.

Reproduction without permission is not permitted.
IMPORTANT NOTE:

The IQ Shock is intended to be installed on doors with or without glass inserts and
on window frames but not on the actual glass surface.
MAGNET

Exterior Doors

Sliding
glass
doors
Windows



CHOOSE
INSTALLATION
LOCATION
Two dip switches allow you to customize the behavior of this device:

STEP

2
DIP

SWITCH
CONFIGURATION
STEP

1
DS#1 - Installer Test Mode:

-
Calibrates accelerometer orientation.

-
LED is Active for dialing in shock
sensitivity with potentiometer.

-
Please note, when test mode is enabled
(ON) the IQ Shock Mini will NOT transmit
signals to the compatible panel.
 
This
mode is only used for initial installation
and calibration of the shock sensor.
ON:

OFF:

-
Disables installer
test mode.
DS#2 - Reed Switch:

ON:

OFF:

-
Enables reed switch (must be ON for UL
installations).
-
Disables reed switch.

SENSITIVITY
LEVEL
ON
1
2
MAX
MIN
LED
DIP

SWITCHES
Sensitivity Level:

CLOCKWISE:

COUNTER-
CLOCKWISE:
-
More Sensitive
-
Less Sensitive

Sensor: 2.5”H x 1”W x .5”D

Code outputs: tamper, tamper restore, alarm, alarm restore, low battery.

Transmitter frequency: 319.5 MHz

Supervisory keep-alive interval: 70 minutes.

RF Peak field strength: typical 36000 uV/m at 3m

UL/ULC listed for residential use only

Operating Temperature: 0C~49C

Relative Humidity: 5-93% Non-Condensing

Storage Temperature: -25-70C

For use indoor, in dry, ordinary locations only.

Door frame height: typical 7ft to 8ft (213 to 244 cm)

Door frame width: typical 1ft to 4ft (30.5 to 122 cm)

Door frame thickness: 1 1/2" to 1 3/4" (3.8 to 4.4 cm)
-
IQ Shock Mini-S can be installed on sliding glass doors,
windows, doors that swing and more.

-
Enclosure base is secured to the installation surface with
double sided tape, manufactured by 3M, part number 4945,
UL recognized under file MH17478 (QOQW2).

-
UL/ULC NOTE:

The IQ Shock Mini - S has been listed by UL/ULC for
residential applications only and in accordance with the
requirements in the Standards UL 634 and UKLC/ORD-
C634 for Door and Window Contact with supplementary
Shock Sensor. The shock sensor is for supplementary
detection only and not for primary protection of the surface
and is not intended for use as a glass break detector.
Battery Life Expectancy: 5 years (for typical use) with all sensors
enabled. (Not tested by UL/ULC). Replace battery with exact
replacement, 3V Panasonic CR2032 Lithium (x2). Low battery
threshold (2.55v). Note: For UL/ULC certified installations replace
battery yearly.

MAINTENANCE CAUTION!

This product uses Lithium Batteries. Improper handling of lithium
batteries may result in HEAT GENERATION, EXPLOSION or FIRE,
which may lead to personal injuries.

WARNING! DANGER OF EXPLOSION IF BATTERIES ARE INSTALLED
INCORRECTLY. REPLACE ONLY WITH THE SAME OR EQUIVALENT
TYPE RECOMMENDED BY THE MANUFACTURER. KEEP AWAY FROM
SMALL CHILDREN: IF SWALLOWED PROMPTLY SEE A DOCTOR. Do
not try to recharge these batteries. For use only with IQ Panel 4, IQ4 Hub, IQ4 NS or IQ Pro variants with compatible SRF 319.5MHz daughter card receiver installed.
ADDITIONAL INFORMATION
PLACEMENT TESTING:
Before permanently mounting any wireless device, temporarily mount the device and perform a placement test from the control panel.
For
detailed placement instructions refer to the control panel installation manual.

IMPORTANT!
Only GOOD or STRONG signal strengths are acceptable. If you receive a POOR signal from the device, re-locate it and re-test
until a GOOD or STRONG signal is received.

Note:
For UL/ULC installations, only STRONG signal levels are acceptable. After installation verify the product functionality in conjunction
with the compatible panel receiver.
GAP SEPARATION:
COMPATIBLE RECEIVERS:
Recommended maximum gap separation for installation depends on specified materials and axes of use is 6.25mm (0.25”). See table below.
STEP

3
STEP

5
APPLY
ADHESIVE
STEP

4
REMOVE
BATTERY
TABS
MOUNT

SENSOR &
MAGNET
STEP

6
LEARN

INTO

PANEL
Place your
panel in
“Auto Learn”
mode
Open and
close the case
to “tamper”
the device
ADD
Customize name
and settings as
desired and and
touch “ADD”
STEP

7
ADJUST

SHOCK

SENSITIVITY
Adjusting the Shock Sensitivity:

IMPORTANT:
Calibrate the IQ Shock Mini’s accelerometer from the final mounting position by moving dip switch 1 to ON (enable installer test
mode).
 
While in this mode the LED will flash RED when it detects a shock level strong enough to trigger an alarm at the control panel. There are
3 total sensitivity settings and the LED will flash each time the sensitivity threshold is changed.
Please note that no RF transmission from the
sensor occurs during installer test mode.

Gently hit (using the palm of your hand) the surface on which the device is installed. Gradually increase the pressure or turn the shock sensitivity
adjustment dial clockwise with a small screwdriver until the desired response is obtained. Ensure that the device is not triggered by accidental
vibration (e.g., wind, birds, window coverings) hitting the protected window or surface. Normal traffic or operation of the door/window should not
trip the shock sensor. When testing the sensitivity of the unit, do not cause stress or damage to the mounting surface or to the glass.
WARNING:

In order to avoid personal injury while testing sensitivity, do not apply pressure to glass inserts or windows.

Move dip switch 1 to OFF (disable installer test mode) once shock sensitivity has been set to the desired level. Verify that the IQ Shock Mini
properly communicates with the Panel.
Document#: IQSM-IM01

Revision#: 04/27/23

Qolsys Product #: IQSM

FCC ID: 2AAJXQS-IQSKM

IC: 11205A-QSIQSKM

CAN ICES- 3 (B)/NMB- 3(B)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of
the device. Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne
doit pas provoquer d'interférences et (2) cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.
Z
Y
X
Direction of
Movement
Approach/
Make
Remove/
Break
Approach/
Make
Remove/
Break
Axis X
14 - 19mm
19 - 24mm
14 - 27mm
16 - 29mm
Axis Y
10 - 13mm
13 - 18mm
12 - 18mm
15 - 23mm
Axis Z
20 - 26mm
24 - 30mm
20 - 29mm
25 - 32mm
Metallic (ferrous) Materials
Non-Metallic (non-ferrous)
Materials


Uploaded