Qolsys IQ Translator-HT Installation Manual



Document Transcript

QS-8130-P01 IQ Translator TH Instructions.doc
Page 1 of 4
9/18/2013
www.ResolutionProducts.com



QS-8130-P01 IQ Translator™ TH

2GIG
®
-and Honeywell
®
-to-Qolsys Wireless Translator™


Features


Listens to both 2GIG and Honeywell protocol wireles
s devices.


Transmits Qolsys-compatible wireless.


Enrolls up to 63 devices.


Unique wireless ID for each zone, plus 1 for main d
evice.


All sensor alarm, supervisory and trouble signals a
re passed through.


Dual antennas for both Receive and Transmit diversi
ty for reliable range.


Back-up battery operation.

Key Instructions


Not for use with life safety devices, such as Smoke
or CO sensors.


Certain Honeywell Door/Window sensors will not tran
slate correctly. See
NOTICES.


External supply: 12V DC at least 50 mA. Power ter
minals do not care which
wire is positive or negative!


3 AAA Alkaline batteries give 72 hours backup if ex
ternal supply fails. INSTALL
BATTERIES ONLY WHEN EXTERNAL SUPPLY IS READY TO CON
NECT.


Enrolling:


Sensors
1.

Place Panel in Add Sensors mode.
2.

Select the behaviors you want the sensor to have.
3.

Press Translator Enroll switch repeatedly until Dev
ice Type LED
matches the type of device you’re enrolling. ENROL
LING AS WRONG
DEVICE TYPE CAN CAUSE IMPROPER OPERATION.
4.

Trip the particular 2GIG or Honeywell sensor as fol
lows:
o

PIR: Tamper – ENROLL PIRs FIRST
No tamper on Honeywell 5800PIR-RES: Insert battery

o

Panic: Button
o

Key Fob: Lower Right
o

DWS: Tamper
5.

Automatic responses:
o

Green LED blinks on receipt of 2GIG & HW packets.
o

Translator beeps on enrollment into Translator.
o

Red LED blinks on transmit of Qolsys packet to pane
l.
o

The Translator transmits packets to the panel as so
on as it
learns a new sensor.
o

Panel, if in Add Sensors mode, will generally learn
the Trip
Sensor signals simultaneously with the Translator.


Translator itself (necessary to monitor the Transla
tor’s health):
1.

Select Translator Group 13 behavior.
2.

When panel asks to “Trip Sensor”, trip the Translat
or tamper.


Delete all sensors:
1.

Press enroll button repeatedly until all Device Typ
e LEDs are off.
2.

Press and hold enroll key for 5 seconds until beep.


Delete just one Device Type:
1.

Press enroll button repeatedly until target Device
Type LED is lit.
2.

Press and hold enroll key for 5 seconds until beep.

POWERED BY
QS-8130-P01 IQ Translator TH Instructions.doc
Page 2 of 4
9/18/2013
www.ResolutionProducts.com


Operation



Existing 2GIG & Honeywell protocol sensors transmit
as usual. Translator
passes information on to control panel as if they w
ere Qolsys transmitters.

Here is the Fob behavior...
2GIG Fob
Buttons
HNW Fob
Buttons
... do these actions on the Qolsys
system
Unlock
OFF
Unlock
Away
ON
Lock
Stay
Left
Lights
Away+Disarm

Right
Double button press: Lock & Unlock
Star

no action




Translator Module Zone wireless transmission ( uniq
ue ID):
Tamper, when cover opened. Also sends restore.
Low battery, when low battery. Also sends restore.

Supervisory every hour. Supervisory stopped if 12V
DC power absent.
Translator Module does not send any alarm signals a
bout itself.



LED Operation


Green LED


On if 12V DC power present.


Blinks on receipt of 2GIG & Honeywell-compatible pa
ckets.


Red LED


On if device low battery (unless there’s no 12V DC
power).


Blinks on transmit of Qolsys-compatible packets.




Application Diagram
New

Qolsys

Wireless
System
New
Qolsys
Wireless
Sensors

Existing
Honeywell
Wireless
Sensors

Existing
2GIG
Wireless
Sensors
QS-8130-P01 IQ Translator TH Instructions.doc
Page 3 of 4
9/18/2013
www.ResolutionProducts.com


Specifications
Backup batteries:
Three AAA Alkaline.
External supply:
8.5 to 13 VDC or 6-9 VAC
Standard: Resolution RE012: 12VDC, 50mA.
Optional: GE 60-898-ITI, for securing screw
Wire connection polarity DOESN’T matter!
Current draw with supply: 4mA, normal operation.
Power Fail Conditions: 12V DC gone. Translator dev
ice ID supervisories
(including low battery reports) are stopped during
12V DC loss.
Back-up Battery Life on 12V DC Fail: 72 hours (cu
mulative).
Device Low Battery: When approximately 48 hours rem
ain in back-up.
Housing dimensions: 4x6x1 inches

Design & Manufacture: Resolution Products, Inc.

Specifications subject to change without notice.


Internal Picture


Device Type select switch
Power Terminals

[do not care about polarity!]
Tamper Switch & spring
Device Type Indicator LEDs

Battery bucket for 3 AAAs

Indicator LEDs & buzzer
2 Antennas for:

Dual Diversity Receive and
Dual Diversity Transmit
Note: Antennas mounted
on outer
terminals
QS-8130-P01 IQ Translator TH Instructions.doc
Page 4 of 4
9/18/2013
www.ResolutionProducts.com

Notices

Not for use with life safety devices, such as Smoke
or CO sensors.

“Honeywell”, and “2GIG” are trademarks owned by Hon
eywell International Inc. and 2GIG Technologies
Inc., respectively.

“Translator”is a trademark owned by Resolution Prod
ucts, Inc.

This Translator product will function with Honeywel
l or 2GIG sensors. However, it is not endorsed by,

nor is officially associated with Honeywell or 2GIG
.

These Honeywell devices, which operate their primar
y zone on Loop 1, will not function correctly with
the Translator, and should not be attempted to use:
5800 Micra, 5811 Micro, 5814 Micro, 5816 Temp,
5818 Recessed, 5820L Slim; and also devices that do
multiple functions on multiple Loops: 5817
Commercial, 5819 Shock, 5870 Asset. These devices
may enroll, but will not function correctly.

Warranty

Qolsys will replace products that are defective in
their first two years.

FCC Notice

This device complies with Part 15 of the FCC rules.
Operation is subject to the following two
conditions:
This device may not cause harmful interference.
This device must accept any interference that may b
e received, including interference
that may cause undesired operation.

Changes or modifications not expressly approved by
Resolution Products, Inc. could void the
user's authority to operate this equipment.

FCC ID: U5X-RE124

IC Notice

This product meets the applicable Industry Canada t
echnical specifications/Le présent materiel
est conforme aux specifications techniques applicab
les d’Industrie Canada. Operation is subject
to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, includ
ing interference that may cause
undesired operation of the device.
To reduce potential radio interference to other use
rs, the antenna type and its gain should be
so chosen that the equivalent isotropically radiate
d power (e.i.r.p.) is not more than that
permitted for successful communication.
This device has been designed to operate with the a
ntennas listed below, and having a
maximum gain of 2 dBi. Antennas not included in thi
s list or having a gain greater than 2 dBi
are strictly prohibited for use with this device. T
he required antenna impedance is 50 ohms.
- Resolution-supplied 8.5" monopole antenna
IC: 8310A-RE124

Patents