Honeywell Home PROTAKEOVER Transmitter Compatibility Chart - Dated 6/20 Rev. A
Related Products
Document Transcript
PROTAKEOVER
Wireless Converter Communication Module
PROTAKEOVER Compatibility
The PROTAKEOVER module is compatible with the brand
s and model numbers listed in the following table.
Special enrollment requirements for the applicable
modules are also provided.
The Sensors are enrolled or “learned” into the syst
em using the AlarrmNet 360 (AN360) programming Tool
(www.alarmnet360.com) using the “Add New Sensor” pr
ograming option. The sensor can be enrolled via RF
Learning or by manually by entering the serial numb
er. Select Sensor Type 5800 or Takeover from the dr
op-
down options. When entering manually, AN360 will ac
cept a maximum of seven digits and will not accept
special characters. Once enrolled, certain sensors
require the programming of additional attributes as
noted in
the accompanying table.
After entering AN360, Select Sensors> Add sensor >
Learn > Fault sensor >Accept serial number > Enter
Loop
number > Enter device type > Zone type > Select Don
e > Save or Save and Add Another
For devices that support more than one loop, AN360’
s add service/loop option is used to add additional
loops.
Note:
The applicable brand protocol must be selected on
the PROTAKOVER module. (The options include
5800, 2GIG, DSC, ITI/Qolsys and Bosch.
Using devices not listed here as compatible is not
recommended and may cause unexpected behavior.
Brand
Model No.
Sensor Type
Enrollment Process
Resideo
5814
Window Ultra Small
For the reed loop, open th
e magnetic contact for
2 seconds and close the contact. Repeat for a
total of 3 times. For the tamper, no tripping is
needed. The sensor will automatically report
tamper if any loop is learned. In AN360 enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Perimeter
5815/5815WG
Door/Window Transmitter
For the hardwi
re loop, open the contact for 2
seconds and close the contact. Repeat for a
total of 3 times. For the reed loop, open the
magnetic contact for 2 seconds and close the
contact. Repeat for a total of 3 times. For the
tamper, no tripping is needed. The sensor will
automatically report tamper if any loop is
learned. In AN360 enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Perimeter
5816/5816OD
Door/Window Transmitter
Outdoor Wireless Contact
Transmitter
For the Reed loop, open the magnetic contact
for 2 seconds and close the contact for 2
seconds. Repeat for a total of 3 times. In AN360
enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Perimeter
5817XT
Three Point Wireless Transmitter
For each h
ardwire loop, open the contact for 2
seconds and close the contact. Repeat for a
total of 3 times. Each of the 3 hardwire loops
must be enrolled separately. For tamper, no
tripping is needed. The sensor will automatically
report troubles if any loop is learned. In AN360
enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Perimeter Brand
Model No.
Sensor Type
Enrollment Process
Resideo
(Continued)
5817CBXT
Three Zone Commercial
Fire/Burg Transmitter
DIP switch #1 must be off during enrollment. For
the supervised hardwire loop, short the contact
for 2 seconds and restore the 470kohm
resistance for 2 seconds. Repeat for a total of 3
times. For the unsupervised hardwire loop, open
contact for 2 seconds and close the contact.
Repeat for a total of 3 times. For the reed loop,
open the magnetic contact for 2 seconds and
close the contact. Repeat for a total of 3 times.
For tamper, no tripping is needed. The sensor
will automatically report tamper if any loop is
learned. In AN360 enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Perimeter
5818MNL
Door Recessed
For the reed loop, open the
magnetic contact for
2 seconds and close the contact for 2 seconds.
Repeat for a total of 3 times. In AN360 enter:
•
Loop number = 1
•
Device type = Door or Window
Response type = Perimeter
5819S
Wireless Shock Sensor
Enroll by faulting and restoring Loop 1 (shock),
Loop 2 (magnet/reed), Loop 3 (terminal) for a
total of 3 times for each loop. Shock the sensor,
open the magnetic contact or short the terminal
with a wire as applicable. In AN360 enter:
•
Loop number = 1
•
Device type = Door or Window
•
Response type = Perimeter
5820L
Slim Line Transmitter
For the reed loop, ope
n the magnetic contact for
2 seconds and close the contact. Repeat for a
total of 3 times. For the tamper, no tripping is
needed. The sensor will automatically report
tamper if any loop is learned. In AN360 enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Perimeter
5821
Flood Detector
Enroll remote flood detector only by
faulting and
restoring
the case tamper.
Note:
Do not enroll more than 1 loop.
In AN360 enter:
•
Loop number = 1
•
Device type = Flood
•
Response type = Monitor
5822T
Tilt Sensor
Remove the sensor from the garag
e door to
enroll. For the tilt loop, fault the 5822T by
rotating the device to simulate garage door
movement to the open position and holding it for
2 seconds. Restore it by returning it to the
closed garage door position and hold again for 2
seconds. Repeat motion for a total of 3 times.
For the hardwire loop, open contact for 2
seconds and close the contact. Repeat for a
total of 3 times. For the tamper, no tripping is
needed. The sensor will automatically report
tamper if any loop is learned. In AN360 enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Perimeter Brand
Model No.
Sensor Type
Enrollment Process
Resideo
(Continued)
5853
Glass Break Detector
Enroll by faulting and re
storing the tamper. In
AN360 enter:
•
Loop number =1
•
Device type = Glass Break
•
Response type = Perimeter
5869
Wireless Hold-Up Switch
Slide red switch to e
ngage, use key to release
lock after 2 seconds. Repeat for a total of 3
times. For the tamper, no tripping is needed.
The sensor will automatically report tamper if
any loop is learned. In AN360 enter:
•
Loop number =1
•
Device type = Police
•
Response type = 24hr Audible
5898
DUAL TEC Motion Sensor
Remove all the batteri
es and reinstall to enter
the test mode for 10 minutes. Reassemble the
device. Wait for the LED to flicker and turn
yellow. Trigger the motion sensor for 2 seconds
and stop motion to allow it to restore. Repeat for
a total of 3 times. For the tamper, no tripping is
needed. The sensor will automatically report
tamper if any loop is learned.
Note:
The Low Temperature loop is not
supported and cannot be learned
In AN360 enter:
•
Loop number =1
•
Device type = Pir
•
Response type = Interior Follower
5800PIR-OD
Wireless Outdoor Motion Sensor
Set DIP
switch 1 to ON to enter Walk test mode.
Reassemble the device. Trigger the motion
sensor for 2 seconds and stop motion to allow it
to restore. Repeat for a total of 3 times. For the
tamper, no tripping is needed. The sensor will
automatically report tamper if any loop is
learned. Set DIP switch 1 to OFF for normal
operation. In AN360 enter:
•
Loop number =1
•
Device type = Pir
•
Response type = Interior Follower
5800PIR-RES
Wireless Motion Detector -
Residential
Remove the battery and reinstall to enter the
test mode for 10 minutes. Reassemble the
device. Trigger the motion sensor for 2 seconds
and stop motion to allow it to restore. Repeat for
a total of 3 times.
Note:
The Low/High Temperature loop is not
supported and cannot be learned.
In AN360 enter:
•
Loop number =1
•
Device type = Pir
•
Response type = Interior Follower
5800PIR-COM
Passive Infrared Motion Sensor -
Commercial
Remove the battery and reinstall to enter the
test mode for 10 minutes. Reassemble the
device. Trigger the motion sensor for 2 seconds
and stop motion to allow it to restore. Repeat for
a total of 3 times. For the tamper, no tripping is
needed. The sensor will automatically report
tamper if any loop is learned. In AN360 enter:
•
Loop number =1
•
Device type = Pir
•
Response type = Interior Follower
Brand
Model No.
Sensor Type
Enrollment Process
DSC
WS4945
Door/Window Sensor
When using the magnet, op
en contact for 2
seconds and close. Repeat for a total of 3
times. When using the reed loop, open the
magnetic contact for 2 seconds and close.
Repeat for a total of 3 times. In AN360 enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Perimeter
EV-DW4917
Door/Window Sensor
For the reed loop, ope
n the magnetic contact for
2 seconds and close. Repeat for a total of 3
times. In AN360 enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Entry Exit Follower
WS4985
Wireless Flood Detector
Enroll by
faulting and
restoring
the tamper.
AN360 enter:
•
Loop number = 1
•
Device type = Flood
•
Response type = Monitor
WLS914
Wireless Pet-Immune Passive
Infrared Detector
Enroll by
faulting and restoring
the tamper. In
AN360 enter:
•
Loop number = 1
•
Device type = PIR
•
Response type = Interior Follower
EV-DW4975
Door/Window Sensor
For the reed loop, open the magn
etic contact for
2 seconds and close. Repeat for a total of 3
times. In AN360 enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Entry Exit Follower
WLS922L
Wireless Glassbreak Detector
Enroll by
faulting and restoring
the tamper. In
AN360 enter:
•
Loop number = 1
•
Device type = Glassbreak
Response type = Perimeter
WS4904
Wireless Passive infrared
Detector
Enroll by
faulting and restoring
the tamper. Set
to loop 1 on save. In AN360 enter:
•
Loop number = 1
•
Device type = PIR
•
Response type = Interior Follower
DW4927SS
Wireless Shock Sensor with Built-
In Door/Window Contact
Shock the sensor and allow it to restore a total
of 3 times.
Note:
The door/window contact trips the same
zone as shock and is not separately
learned.
In AN360 enter:
•
Loop number = 1
•
Device type = Window
•
Response type = Perimeter
Brand
Model
No.
Sensor Type
Enrollment Process
2GIG
2GIG-DW20R-345 Recessed Door/Window Contact
For the
reed loop, open the magnetic contact for
2 seconds and close. Repeat for a total of 3
times. For the tamper, no tripping is needed.
The sensor will automatically report tamper if
any loop is learned. In AN360 enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Perimeter
2GIG-DW10-345
Thin Door/Window Contact
For the reed
loop, open the magnetic contact for
2 seconds and close. Repeat for a total of 3
times. For the hardwire loop, open contact for 2
seconds and close. Repeat for a total of 3
times. For the tamper, no tripping is needed.
The sensor will automatically report tamper if
any loop is learned. In AN360 enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Perimeter
2GIG-TILT1-345
Tilt Sensor
Remove the sensor from
the garage door to
enroll. For the tilt loop, fault it by rotating the
device simulate garage door movement to the
open position, holding it for 2 seconds. Restore
it by returning it to the closed garage door
position and hold again for 2 seconds. Repeat
motion for a total of 3 times. For the tamper, no
tripping is needed. The sensor will automatically
report tamper if any loop is learned. In AN360
enter:
•
Loop number = 1
•
Device type = Garage Door
•
Response type = Garage
2GIG-FT1-345
Flood and Temperature Sensor
Enroll by faulting and restoring the tamper.
Note:
Do no enroll more than 1 loop. In AN360
enter:
•
Loop number = 1
•
Device type = Flood
•
Response type = Monitor
2GIG-GB1-345
Wireless Glass Break Detector
Enroll by faulting and restoring the tamper. In
AN360 enter:
•
Loop number = 1
•
Device type = Glassbreak
•
Response type = Perimeter
2GIG-PIR1-345
Passive Infrared Motion Detector
Enroll by faulting and restoring the tamper. In
AN360 enter:
•
Loop number = 1
•
Device type = PIR
•
Response type = Interior Follower
ITI
TX-E201
Door/Window Sensor
For the reed loop, open the magn
etic contact for
2 seconds and close. Repeat for a total of 3
times. For the tamper, no tripping is needed.
The sensor will automatically report tamper if
any loop is learned. In AN360 enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Entry Exit Follower
Brand
Model
No.
Sensor Type
Enrollment Process
ITI
(Continued)
TX-E221
Door/Window Sensor
For the reed loop, open
the magnetic contact for
2 seconds and close. Repeat for a total of 3
times. For the tamper, no tripping is needed.
The sensor will automatically report tamper if
any loop is learned. In AN360 enter:
•
Loop number = 1
•
Device type = Door
•
Response type = Entry Exit Follower
TX-E401
Tilt Sensor
Remove the sensor from the gara
ge door to
enroll. For the tilt loop, fault it by rotating the
device simulate garage door movement to the
open position, holding it for 2 seconds. Restore
it by returning it to the closed garage door
position and hold again for 2 seconds. Repeat
motion for a total of 3 times. In AN360 enter:
•
Loop number = 1
•
Device type = Garage Door
•
Response type = Garage
TX-E611
Flood/Freeze Sensor
Sensor has separate serial numbers for flood
low temp. To learn as a flood sensor, tap a
magnet to the sensor at the point indicated by
the line.
Repeat as required. Save as loop 1.
To learn the freeze sensor, tap and hold a
magnet at the point indicated by the line for two
seconds. Repeat as required. Save as loop 1.
In
AN360 enter:
•
Loop number = 1
•
Device type = Flood or Temp
•
Response type = Monitor
60-362N-10-319.5 Door/Window Sensor
For the hardwir
e loop, open contact for 2
seconds and close. Repeat for a total of 3
times. For the reed loop, open the magnetic
contact for 2 seconds and close. Repeat for a
total of 3 times. For the tamper, no tripping is
needed. The sensor will automatically report
tamper if any loop is learned. In AN360 enter:
•
Loop number = 1
•
Device type = Door or Window
•
Response type = Perimeter
Bosch
Radion RFDW-
SM-A
Surface Mount Door/Window
Sensor
For the reed loop, open the magnetic contact for
2 seconds and close. Repeat for a total of 3
times. For the tamper, no tripping is needed.
The sensor will automatically report tamper if
any loop is learned. In AN360 enter:
•
Loop number = 1
•
Device type = Door or Window
•
Response type = Perimeter
Radion RFUN-A
Radion Universal Transmitter
For the
supervised hardwire loop, short the
contact for 2 seconds and restore the 2.2kohm
resistance for 2 seconds. Repeat for a total of 3
times. For the reed loop, open the magnetic
contact for 2 seconds and close. Repeat for a
total of 3 times. In AN360 enter:
•
Loop number = 1
•
Device type = Door or Window
•
Response type = Perimeter
– NOTES –
www.resideo.com
Resideo Technologies, Inc
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
© 2020 Resideo Technologies, Inc. All rights reserv
ed.
The Honeywell Home trademark is used under license
from
Honeywell International, Inc.
This product is manufactured by Resideo Technologie
s, Inc. and its
affiliates.
R800-26221A 6/20 Rev. A
- Uploaded