IMPORTANT!
3-way switches can be wired in different ways. These instructions explain
the most common method. If you have difficulty with the instructions or your
home wiring, contact a licensed electrician for assistance.
1.
Shut off power to the
circuit
at circuit breaker or fuse box.
IMPORTANT!
Verify power is OFF to switch box before continuing.
2.

Remove both wallplates.
3.
Remove the switch mounting screws.
4.

Carefully remove both switches from each switch box location. DO NOT
disconnect the wires yet.
5.

Identify switch connected to fuse box. This is the “Line Switch.” Label
wire connected to Common terminal, “LINE.”
6.

Identify switch connected to lighting/fixture. This is the “Load Switch.”
Label wire connected to Common terminal, “LOAD.”
OBSERVE IMPORTANT WIRING INFORMATON
IMPORTANT!
This switch is rated for and intended
to only be used with copper wire.
WIRE GAUGE REQUIREMENTS
Use 14 AWG or larger wires suitable for at least 80° C for supplying Line
(HOT), Load, Neutral, Ground and Traveler connections.
WIRE STRIP LENGTH:
7.
For attachment to screw terminals:
strip insulation 1” (25mm).
8.

For attachment using the enclosure’s holes:
strip insulation 5/8” (16mm).
UL specifies that the tightening torque for the screws is
14 Kgf-cm (12 lbf-in).
SWITCH CONNECTED TO FUSE BOX “LINE SWITCH”

(REPLACING STANDARD SWITCH WITH HONEYWELL HOME PRIMARY
SWITCH)
9.
Disconnect all wires on existing switch.
10.
Locate neutral wires found inside switch box. Remove wire nut securing
them (A). (These are typically a bundle of white wires in the back of the box.)
11.
Locate jumper wire (included in packaging of primary switch). Connect
with neutral wires and secure again with wire nut previously removed (A).
12.
Connect opposite end of jumper wire to NEUTRAL terminal on Primary
Switch (B).
13.

Connect wire you previously labeled, “LINE” to LINE terminal on
Primary Switch (C).
14.
Connect ground wire (bare/copper/green) to GROUND terminal on
Primary Switch (D).
15.
Connect one of the two remaining wires (T1) to LOAD terminal on
Primary Switch (E). Write down the color of the wire. You will need this
when installing the Add-on switch.
16.
Connect the remaining wire (T2) to TRAVELER terminal on the Primary
Switch (F).
SWITCH CONNECTED TO LIGHTING “LOAD SWITCH”

(REPLACING STANDARD SWITCH WITH HONEYWELL HOME ADD-ON
SWITCH)
17.
Disconnect all wires on existing switch.
18.
Locate neutral wires found inside switch box. Remove wire nut
securing them (AA). (These are typically a bundle of white wires in the
back of the box.)
19.

Locate jumper wire (included in packaging of primary switch). Connect with
neutral wires and secure again with wire nut previously removed (AA).
20.

Connect opposite end of jumper wire to NEUTRAL terminal on Add-on
Switch (BB).
21.

Connect ground wire (bare/copper/green) to GROUND terminal on
Add-on Switch (CC).
22.
Locate the same colored wire you wrote down previously in the switch
box (T1). Using a wire nut, secure it only to the wire you previously
labeled, “LOAD.”
23.
Connect the remaining wire to TRAVELER terminal on the Add-on
Switch (DD). This will be the same color as the wire connected to
TRAVELER terminal on the primary switch.
ATTACH SWITCH TO BOX
24.
Carefully place both switches into their respective switch box, being
careful not to pinch or crush wires.
25.

Secure each switch to the box using the supplied screws.
26.

Mount each switch wallplate.
27.

Reapply power to the circuit at fuse box or circuit breaker and test


the system.
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting
fixture at the service
panel.
All wiring connections must be made with the POWER OFF to avoid personal injury
and/or damage to the switch. This device is intended for installation in accordance with the
National Electric Code and local regulations in the United States, or the Canadian Electrical
Code and local regulations in Canada. If you are unsure or uncomfortable about performing
this installation consult a qualified electrician.
SINGLE-, DUAL- AND TRIPLE-GANG BOXES
When installing the Add-on switch in multiple-gang boxes, it may be
necessary to break off one or both sides of the scored tabs on the front yoke.
A.
Neutral
(White)
B.
Traveler
(Red/Other)
C.
Ground
(Green/Bare)
D.

The Add-on switch takes
the characteristics of the
primary switch. Refer to the
primary switch’s manual for
instructions.
TOOLS
INSTALLATION
1
3
1.
CHANGING THE COLOR OF THE PADDLE
This step is optional. Before you start you may want to change the color of
the paddle to match your wallplate or decor.
1.
Push side tabs in on one side and then the other to release paddle. Lift
the cover up and off.
2.
Simply put the new paddle onto the switch by side tabs and

snap securely into place.
Once this step has been completed please proceed to Section 3.
2
CUSTOMIZATION
1
1
2
3
25
26
27
27
B
A
D
C

10
5
9
23
6
STANDARD 3-WAY SWITCH WIRING
LINE
SWITCH
OUT TO ;LOAD
SWITCH
OUT TO ;LIGHT
(LOAD)
FROM BREAKER BOX
IN FROM LINE SWITCH
LOAD
SWITCH
HONEYWELL HOME ADD-ON SWITCH WIRING
LINE SWITCH
(PRIMARY SWITCH)
LOAD SWITCH
(ADD ON SWITCH)
OUT TO LIGHT (LOAD)
FROM BREAKER BOX
LINE
LINE
NEUTRAL JUMPER
GROUND
NEUTRAL
NEUTRAL
LOAD
LOAD
GROUND
IN FROM LINE SWITCH
T2
T2
T2
T2
T2
T2
T1
T1
T1
T1
T1
T1
D
E
C
F
B
A
A
AA
AA
CC
DD
BB
NEUTRAL JUMPER
-
COMMON
COMMON
ADD-ON SWITCH
IN-WALL
INTERRUPTOR AUXILIAR
DE LA PARED
INTERRUPTEUR SUPPL
É
MENTAIRE
DANS LE MUR
Z53WSWITCH
ZW2004
MADE IN CHINA/FABRIQUÉ EN CHINE/ HECHO EN CHINA
39457 | ZW2004 | 04/05/19 v3
All brand names shown are
trademarks of their respective owners.
Tous les noms de marque illustrés
sont des marques de commerce
de leurs propriétaires respectifs.
odos los nombres de marca
que aparecen son marcas
comerciales pertenecientes a
sus respectivos propietarios.
Resideo Technologies, Inc.
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melv ille, NY 11747
www.security.honeywellhome.com
| 1-800-645-7492
RISK OF FIRE

RISK OF ELECTRICAL SHOCK

RISK OF BURNS
CONTROLLING APPLIANCES:
CAUTION:

DO NOT EXCEED RATINGS

DO NOT USE TO CONTROL ANY DEVICE
WHERE UNINTENDED OPERATION
COULD CAUSE UNSAFE CONDITIONS
(HEAT LAMP, SUN LAMP, ETC.)

DO NOT USE TO CONTROL
RECEPTACLES

FOR INDOOR USE ONLY
RISQUE D’INCENDIE

RISQUE DE CHOC ÉLECTRIQUE

RISQUE DE BRÛLURES
COMMANDE DES APPAREILS :
ATTENTION :

NE PAS DÉPASSER LES
CARACTÉRISTIQUES NOMINALES

NE PAS UTILISER POUR COMMANDER
DES APPAREILS POUR LESQUELS
UN FONCTIONNEMENT IMPRÉVU
POURRAIT ENTRAÎNER DES
CONDITIONS DANGEREUSES (LAMPE
INFRAROUGE, LAMPE SOLAIRE, ETC.)

NE PAS UTILISER POUR COMMANDER
DES PRISES DE COURANT

POUR UTILISATION INTÉRIEURE
UNIQUEMENT
RIESGO DE INCENDIO

RIESGO DE DESCARGA ELÉCTRICA

RIESGO DE QUEMADURAS
CONTROL DE APARATOS:
PRECAUCIÓN:

NO SUPERAR LOS VALORES
NOMINALES ELÉCTRICOS.

NO USAR PARA CONTROLAR
DISPOSITIVOS EN LOS QUE
EL FUNCIONAMIENTO NO
INTENCIONADO PODRÍA PROVOCAR
SITUACIONES PELIGROSAS
(LÁMPARAS DE CALEFACCIÓN,
LÁMPARAS SOLARES, ETC.)

NO UTILIZAR EL DISPOSITIVO PARA
CONTROLAR TOMACORRIENTES

PARA USO EN INTERIORES
EXCLUSIVAMENTE
WARNING
AVERTISSEMENT
ADVERTENCIA
NOT FOR USE WITH MEDICAL OR
LIFE SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES SHOULD
NEVER BE USED TO SUPPLY
POWER TO, OR CONTROL THE ON/
OFF STATUS OF MEDICAL AND/
OR LIFE SUPPORT EQUIPMENT.
NE PAS UTILISER AVEC UN
ÉQUIPEMENT MÉDICAL
OU DE SURVIE
LES DISPOSITIFS COMPATIBLES
AVEC LA TECHNOLOGIE Z-WAVE NE
DEVRAIENT JAMAIS ÊTRE UTILISÉS
POUR ALIMENTER OU COMMANDER
LA MISE EN MARCHE OU L’ARRÊT DE
L’ÉQUIPEMENT MÉDICAL OU DE SURVIE.
SE PROHÍBE SU EMPLEO EN
EQUIPO MÉDICO O EQUIPO
PARA EL MANTENIMIENTO DE
LAS FUNCIONES VITALES
LOS DISPOSITIVOS Z-WAVE NUNCA
SE DEBEN USAR PARA SUMINISTRAR
ENERGÍA ELÉCTRICA, NI PARA
CONTROLAR EL ESTADO DE ENCENDIDO
O APAGADO DEL EQUIPO MÉDICO Y/O
EL EQUIPO PARA EL MANTENIMIENTO
DE FUNCIONES VITALES.
ZW2004
Power: 120 VAC, 60 Hz.
Operating Temperature Range: 32-104° F (0-40° C)
For indoor use only.
Specifications subject to change without notice due to continuing product improvement
ZW2004
Tension : 120 VCA, 60 Hz.
Plage de températures de fonctionnement : de 32 à 104 °F (de 0 à 40 °C).
Utilisation intérieure uniquement.
En raison d’améliorations continues du produit, les spécifications
peuvent faire l’objet de changements sans préavis.
ZW2004
Alimentación: 120 VAC, 60 Hz
Rango de temperatura de funcionamiento: 32-104 °F (0-40 °C).
Para espacios interiores solamente.
Especificaciones sujetas a cambio sin aviso debido a continuas mejoras del producto
SPECIFICATIONS
SPÉCIFICATIONS
ESPECIFICACIONES
https://mywebtech.honeywellhome.com/
SUPPORT
SOUTIEN
APOYO
https://www.security.honeywellhome.com/

hsc/resources/wa/index.html
U.S. WARRANTY
U.S. GARANTIE
GARANTÍA DE U.S.
MyWebTech
Warranty/Garantie/
Garantía
The Honey well Home trademark is used under license

from Honeywell International, Inc.

This product is manufactured by Resideo.


Uploaded