WIRING
1.
Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT!
Verify power is OFF to switch box before continuing.
2.
Remove wallplate.
3.
Remove the switch mounting screws.
4.
Carefully remove the outlet from the outlet box.
5.
Disconnect the wires from the existing outlet. Label wires
according to the previous terminal connection.
6.
There are three screw terminals on the Z-Wave Smart Outlet;

these are marked:
A.
LINE (Hot) — Black (connected to power)
B.
NEUTR AL — White
C.
GROUND — Green/Bare
Match these screw terminals to the wires connected to the
existing outlet.
OBSERVE IMPORTANT WIRING INFORMATION
WIRE STRIP LENGTH
Always follow the recommended wire strip length (5/8in./16mm)
and wiring combination when making wiring connections. Consult
an electrician with questions or for professional installation.
UL specifies the tightening torque for the screws is 14 Kgf-cm (12 lbf-in).
IMPORTANT!
This receptacle is rated for and intended to only be used with
copper wire.
WIRE GAUGE REQUIREMENTS
Use 14 AWG or larger wires suitable for at least 80° C for supplying line (hot),
neutral, and ground connections.
7.
Insert Z-Wave controlled outlet into the box being careful not to pinch or
crush wires.
8.
Secure the outlet to the box using the supplied screws.
9.
Mount the wallplate.
10.
Reapply power to the circuit at fuse box or circuit breaker and test
the system.
BASIC OPERATION
The connected device can be turned ON/OFF in two ways:

Manually from the front program button.

Remotely with a Z-Wave controller.
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the
service panel. All wiring connections must be made with the POWER OFF to avoid
personal injury and/or damage to the outlet. This device is intended for installation in
accordance with the National Electric Code and local regulations in the United States,
or the Canadian Electrical Code and local regulations in Canada. If you are unsure or
uncomfortable about performing this installation, consult a qualified electrician.
AVAILABLE CONFIGURATION PARAMETERS
LED light
Parameter No: 3
Length = 1 by te
Possible values = 0, 1 (default) or 2
Value descriptions

“0”
- LED ON when load is OFF, LED OFF when ON

“1”
- LED ON when load is ON, LED OFF when load is OFF

“2”
- LED always OFF
MANUAL LED INVERT METHOD

Device needs to be paired with a Z-Wave certified controller
.

Quickly press the ON/OFF button 10 times; the LED will invert if
done correctly
.
Z-W
ave
® C
ertified
W
ireless
l
ighting
C
ontrol
C
ommande

d

éClairage

sans

fil

Certifiée
Z-W
ave
®
Z-W
ave
® C
ontrol

de
i
lumina
Ción
i
nalámbri
Co

Certifi
Cado
FCC / IC - EN
Z5OUTLET
ZW1002
A.
Line
(Hot)
B.
Neutral
C.
Ground
D.
Always-on outlet
E.
Manual/program button
F.
Z-Wave controlled outlet
A
C
B
IMPORTANT!
The device plugged into the Z-Wave controlled Smart Outlet must not exceed
960W (incandescent); 1800W (15A ) resistive or 1/2HP motor. The total
maximum rating for both outlets combined is 1800W (15A ) resistive load.

One Z-Wave controlled outlet

One always-on outlet

Remote ON/OFF control via the Z-Wave controller/network

Manual ON/OFF control with the manual /program button

Blue LED indicates outlet location in a dark room
FE AT URES
2
TOOLS
INSTALL ATION
1
3
TR
TR
CONNECTING YOUR DEVICE TO A Z-WAVE NET WORK
1.
Follow the instructions for your Z-Wave certified controller to add a
device to the Z-Wave network.
2.
Once the controller is ready to add your device, press and release the
program button. Repeat as necessar y to add the smart outlet to

the network.
Now, you have complete control to turn your fixture ON/OFF according to
groups, scenes, schedules and interactive automations programmed by

your controller.
If your Z-Wave certified controller features remote access, you can control
your fixture from your mobile devices.
REMOVING AND RESETTING THE DEVICE
1.
Follow the instructions for your Z-Wave certified controller
to remove a device from the Z-Wave network.
2.
Once the controller is ready to remove your device, press and release
the manual /program button to remove it from the network.
RETURNING SWITCH TO FACTORY DEFAULTS
Quickly press the button 3 times, then press and hold the button
for at least 3 seconds. The LED will blink 5 times to confirm.
Note:
This should only be used in the event your network ’s
primary controller is missing or otherwise inoperable.
CONNECTION
4
This device supports Association Command Class (3 Groups)

Association Group 1 suppor ts Lifeline, Binar y Switch Repor t

Association Group 2 suppor ts Basic Set and is controlled
by pressing the ON or OFF button with the local load

Association Group 3 suppor ts Basic Set and is controlled
by double pressing the ON or OFF button

Each Association Group suppor ts 5 total nodes
8
from
brea
Ker
bo
X
6
9
B
A
C
1
1
2
6
3
D
E
F
SMART OUTLET
IN-WALL TAMPER RESISTANT
TOMACORRIENTE INTELIGENTE
TOMACORRIENTE DE PARED A PRUEBA DE ALTERACIONES
PRISE INTELLIGENTE
INVIOLABLE À MONTAGE MURAL
This product can be included and operated in any Z-Wave network with other Z-Wave cer tified
devices from other manufacturers and/or other applications. All non-batter y operated nodes
within the network will act as repeaters regardless of vendor to increase reliabilit y of the network.
Ce produit peut être utilisé dans un réseau Z-Wave avec d’autres appareils
cer tifiés Z-Wave produits par d’autres fabricants et d’autres applications. Tous les
nœuds fonctionnant sans pile au sein du réseau joueront le rôle de répétiteurs,
quel que soit le fournisseur, afin de rehausser la fiabilité du réseau.
Este producto se puede incluir y puede funcionar en cualquier red Z-Wave con dispositivos
de otros fabricantes y otras aplicaciones que cuenten con la homologación Z-Wave. Todos
los nodos que formen par te de la red y que funcionen sin pilas actuarán de repetidores
independientemente del proveedor con el fin de aumentar la fiabilidad de la red.
Z W1002
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.4/916MHz
Total maximum load for both outlets: 180 0W (15A) resistive
Maximum load for Z-Wave controlled outlet: 960W, incandescent,
1/2HP Motor or 180 0W (15A) resistive
Range: Up to 150f t. line of sight between the wireless controller
and the closest Z-Wave receiver module.
Operating temperature range: 32-104° F (0-4 0° C)
For indoor use only.
Specifications subject to change without notice due to continuing product improvement
Z W1002
Alimentation : 120VCA , 60Hz
Signal (fréquence) : 908.4/916MHz
Charge maximale totale pour les deux prises : résistance de 180 0W (15A)
Charge maximale pour prise commandée Z-Wave : 960W (incandescent),
moteur de 1/2HP ou résistance de 180 0W (15A)
Por tée : Distance à vue maximale de 150 pi (45.7m) entre la télécommande
et le module de réception Z-Wave le plus proche.
Plage de températures de fonctionnement : de 32 à 104° F (de 0 à 4 0° C)
Utilisation intérieure uniquement.
En raison d’améliorations continues du produit, les spécifications
peuvent faire l ’objet de changements sans préavis.
Z W1002
Alimentación: 120VCA , 60Hz
Señal (frecuencia): 908.4/916MHz
La capacidad máxima de carga resistiva de ambos tomacorrientes es de 180 0W (15A).
Carga máxima para el tomacorriente controlado por Z-Wave: 960W,
incandescente, motor de 1/2HP o 180 0W (15A) de carga resistiva
Alcance: hasta 150 pies (45.7m), sin obstrucciones, entre el controlador
inalámbrico y el módulo receptor Z-Wave más cercano.
Rango de temperatura de funcionamiento: 32-104° F (0-4 0° C)
Para uso en interiores exclusivamente.
Las especificaciones están sujetas a cambios sin previo aviso por
las constantes mejoras a que se someten los productos.
SPECIFICATIONS
Z-WAVE INTEROPERABILITY
SPÉCIFICATIONS
INTEROPÉRABILITÉ ENTRE LES DISPOSITIFS Z-WAVE
ESPECIFICACIONES
INTEROPERABILIDAD Z-WAVE
A
C
All brand names shown are trademarks
of their respective owners.
Tous les noms de marque illustrés
sont des marques de commerce
de leurs propriétaires respectifs.
Todos los nombres de marca
que aparecen son marcas
comerciales pertenecientes a
sus respectivos propietarios.
This device complies with Par t 15 of the FCC and Industr y Canada license-exempt
RSS standards. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC NOTE:
The manufacturer is not responsible for any radio or T V interference caused

by unauthorized modifications to this equipment. Such modifications could void the user’s
authorit y to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Par t 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy, and if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee interference will not occur in a par ticular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to tr y to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different
to which the receiver is connected.

Consult the dealer or an experienced radio/ T V technician for help.
Important note:
To comply with the FCC RF exposure compliance requirements, no change to
the antenna or the device is permitted. Any change to the antenna or the device could result in the
device exceeding the RF exposure requirements and void user’s authorit y to operate the device.
FCC /IC - FR
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les
appareils exempts de licence d’Industrie Canada. Son utilisation est sujette aux
deux conditions suivantes (1) cet appareil ne doit pas occasionner de brouillage
préjudiciable et (2) cet appareil doit accepter toutes les interférences reçues, notamment
les interférences qui peuvent provoquer un fonctionnement non désiré.
REMARQUE DE L A FCC :
Le fabricant n’est pas responsable des interférences sur les fréquences
radioélectriques ou télévisuelles pouvant être causées par des modifications non autorisées de
ce matériel. De telles modifications peuvent annuler le droit de l ’utilisateur à utiliser cet appareil.
REMARQUE :
Cet appareil a été testé et cer tifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites
ont été définies afin de fournir une protection raisonnable contre le brouillage préjudiciable
en milieu résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence
radio et, s’il n’est pas installé et utilisé conformément aux instructions, il peut provoquer un
brouillage préjudiciable aux communications radio. Il n’existe toutefois aucune garantie que
des interférences ne se produiront pas dans une installation donnée. Si cet appareil occasionne
un brouillage préjudiciable à la réception radiophonique ou télévisuelle, il suf fit d’allumer et
d’éteindre l ’appareil pour déterminer sa responsabilité. Nous encourageons l ’utilisateur à
essayer de corriger ces interférences en appliquant une ou plusieurs des mesures suivantes :

Réorienter ou déplacer l’antenne de réception.

Augmenter la distance entre l ’appareil et le récepteur.

Brancher l ’appareil à une prise secteur différente de celle du récepteur.

Pour obtenir de l ’aide, consulter le revendeur ou un technicien
spécialisé en postes radio ou téléviseurs.
Remarque importante
:
Pour se conformer aux exigences de conformité de la
FCC concernant l ’exposition aux RF, aucune modification appor tée à l ’antenne
ou au dispositif n’est autorisée. Toute modification apportée à l ’antenne ou au
dispositif pourrait faire en sor te que le dispositif dépasse les exigences d’exposition
aux RF et pourrait annuler le droit de l ’utilisateur à utiliser ce dispositif.
FCC /IC - ES
Este dispositivo cumple con las especificaciones del apar tado 15 de las normas de
la FCC y con las especificaciones de las normas radioeléctricas (RSS) del Ministerio
de Industria de Canadá aplicables a aparatos exentos de licencia. El funcionamiento
está sujeto a las siguientes dos condiciones: (1) este dispositivo no debe provocar
interferencia perjudicial, y (2) este dispositivo debe aceptar toda interferencia
que reciba, incluso la que pudiera causar un funcionamiento no deseado.
NOTA DE L A FCC:
El fabricante no se hace responsable de ninguna interferencia de radio
o T V ocasionada por modificaciones no autorizadas efectuadas a este equipo. Estas
modificaciones podrían anular la autoridad del usuario para utilizar este equipo.
NOTA:
Este equipo ha sido probado y cumple con los límites para dispositivos digitales de
Clase B, de conformidad con el apar tado 15 de la normativa de la FCC. Estos límites están
diseñados para proveer protección razonable contra interferencias perjudiciales en instalaciones
residenciales. Este equipo genera, usa y puede irradiar energía de radiofrecuencias y, si
no se instala y usa según las instrucciones, puede provocar interferencia perjudicial a las
radiocomunicaciones. No obstante, no hay garantías de que no ocurrirá interferencia en una
instalación en par ticular. Si este equipo provoca interferencia perjudicial a la recepción de
radio o televisión, lo que puede determinarse encendiendo y apagándolo, se recomienda que
el usuario intente corregir la interferencia aplicando una o más de las siguientes medidas:

Reorientar o reubicar la antena receptora.

Incrementar la separación entre el equipo y el receptor.

Conectar el equipo a un tomacorriente de un circuito diferente
del circuito al que el receptor está conectado.

Consultar al distribuidor o a un técnico con experiencia en
radio/televisión para solicitar asistencia.
Nota importante:
Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier
cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de
exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
FCC — U2Z Z W10 02 | IC: 6924A-Z W10 02
Model: ZW1002/39456
CAN ICES-3(B)/NMB-3(B)
RISK OF FIRE

RISK OF ELECTRICAL SHOCK

RISK OF BURNS
CONTROLLING APPLIANCES
CAUTION:

DO NOT E XCEED R ATINGS

DO NOT USE TO CONTROL ANY DE VICE
WHERE UNINTENDED OPERATION
COULD CAUSE UNSAFE CONDITIONS
(HE AT L AMP, SUN L AMP, E TC.)

FOR INDOOR USE ONLY
RISQUE D’INCENDIE

RISQUE DE CHOC ÉLECTRIQUE

RISQUE DE BRÛLURES
COMMANDE DES APPAREILS
ATTENTION
:

NE PAS DÉPASSER LES
CARACTÉRISTIQUES NOMINALES

NE PAS UTILISER POUR COMMANDER
DES APPAREILS POUR LESQUELS
UN FONCTIONNEMENT IMPRÉVU
POURRAIT ENTRAÎNER DES
CONDITIONS DANGEREUSES (LAMPE
INFR AROUGE, L AMPE SOL AIRE, E TC.)

POUR UTILISATION INTÉRIEURE
UNIQUEMENT
RIESGO DE INCENDIO

RIESGO DE DESCARGA ELÉCTRICA

RIESGO DE QUEMADUR AS
CONTROL DE APAR ATOS
PRECAUCIÓN:

NO SUPER AR LOS VALORES
NOMINALES ELÉCTRICOS

NO USAR PARA CONTROLAR
DISPOSITIVOS EN LOS QUE
EL FUNCIONAMIENTO NO
INTENCIONADO PODRÍA PROVOCAR
SITUACIONES PELIGROSAS
(LÁMPARAS DE CALEFACCIÓN,
LÁMPARAS SOLARES, ETC.)

PAR A USO EN INTERIORES
EXCLUSIVAMENTE
WARNING
AVERTISSEMENT
ADVERTENCIA
NOT FOR USE WITH MEDICAL OR
LIFE-SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES SHOULD
NE VER BE USED TO SUPPLY POWER TO
OR CONTROL THE ON/OFF STATUS OF
MEDICAL OR LIFE-SUPPORT EQUIPMENT.
NE PAS UTILISER AVEC UN
ÉQUIPEMENT MÉDICAL
OU DE SURVIE
LES DISPOSITIFS COMPATIBLES
AVEC L A TECHNOLOGIE Z-WAVE NE
DEVRAIENT JAMAIS ÊTRE UTILISÉS
POUR ALIMENTER OU COMMANDER
L A MISE EN MARCHE OU L’ARRÊ T DE
L’ÉQUIPEMENT MÉDICAL OU DE SURVIE.
SE PROHÍBE SU EMPLEO EN
EQUIPO MÉDICO O EQUIPO
PAR A EL MANTENIMIENTO DE
L AS FUNCIONES VITALES
LOS DISPOSITIVOS Z-WAVE NUNCA
SE DEBEN USAR PAR A SUMINISTR AR
ENERGÍA ELÉCTRICA , NI PAR A
CONTROL AR EL ESTADO DE ENCENDIDO
O APAGADO DEL EQUIPO MÉDICO Y/O
EL EQUIPO PARA EL MANTENIMIENTO
DE FUNCIONES VITALES.
MADE IN CHINA /FABRIQUÉ EN CHINE /HECHO EN CHINA
39456 | Z W10 02 | 0 4/05/19 v3
Resideo Technologies, Inc.
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
www.security.honeywellhome.com
| 1-800-645-7492
This Z-Wave smar t outlet has advanced features that allow you to customize
your experience — these features can only be adjusted by a Z-Wave enabled
controller that suppor ts the Z-Wave configuration command class.
PARAMETERS
NUMBER
SIZE
DEFINITION
VALUE
3
1
Invert/Disable LED
( Adjusts when the
indicator LED is turned
ON, OFF, or disabled)
0 - LED ON/Device OFF
1 - (Default) LED
ON/Device ON
2 - Disable LED
SUPPORT
SOUTIEN
APOYO
U.S. WARRANTY
U.S. GARANTIE
GARANTÍA DE U.S.
https://mywebtech.honeywellhome.com/
https://www.security.honeywellhome.com/

hsc/resources/wa/index.html
M y WebTe ch
Warranty/Garantie/
Garantía
The Honeywell Home trademark is used under license

from Honeywell International, Inc.

This product is manufactured by Resideo.


Uploaded