Resideo Honeywell Home Vista-21iPLTE Total Connect 2.0 Tech Tip - Addendum



Related Products

Honeywell VISTA-21iPLTE - Internet Alarm Control Panel
Honeywell VISTA-21iPLTE
Internet Alarm Control Panel
List Price: $392.00
Our Price: $242.99

Related Categories


Document Transcript

Document ID 800-21692V1 Rev. A

Ê800-21692IŠ
800-21692V1 5/19 Rev A

The Honeywell Home Trademark is used under license
from Honeywell
International Inc. Total Connect and AlarmNet are
trademarks of
Resideo Technologies, Inc.



Tech TIP

ATTENTION TOTAL CONNECT

2.0 INSTALLER


TO AVOID A SETUP/PROGRAMMING ERROR MESSAGE: WHEN IN
STALLING THIS
SYSTEM FOR USE WITH TOTAL CONNECT 2.0, SEE THE PROG
RAMMING NOTES BELOW

This document applies to
Vista-21IPLTE panels
.

If you found this document included in the control
panel packaging,
it applies to your system
!
NOTE
: If you see the error message shown above, click t
he
TROUBLESHOOTING TIPS
button for a support
document that will help you clear the error.

REQUIRED CONTROL PANEL PROGRAMMING FOR TOTAL CONNEC
T 2.0:

STEP 1. Use program field

29 to set the communicator for IP/Cell.
NOTE
: To avoid overwriting Total Connect settings that
may have been previously programmed when
creating a Total Connect account,
do not
use the control panel’s

29



Communication Device Menu Mode
(pass-through programming) to program the communica
tor. Use AlarmNet360
®
instead.

a. In panel programming, select

29
b. Enter ‘1’ to enable IP/Cell, then select the sta
r key (

) to continue
c. If you are installing this system with an IP con
nection, press ‘0’ to exit field

29 program mode, then select
the star key (

) to continue to Step 2.
DO NOT FULLY ENTER

∗∗

29 COMMUNICATOR PROGRAM MODE


If you are installing this system with LTE-21V only
(no
IP connection), press ‘1’ to enter program mode and

toggle the Internal Device option to Cell only, the
n exit
programming as follows without entering the Primary

City ID at the next prompt:

After toggling to Cell Only: select Function Key D,
then
Function Key A, then select the pound key (#) to ex
it at
the
Review? Y/N
prompt.


STEP 2. Set program field

∗∗

189 to enable the Total Connect remote services key
pad
a. In panel programming, select

189
b. Enter 1, 5, 0, 0

∗∗

189

Touch Screen Device








[default = 1, 1, 0, 0]


(
AUI)

Enable

AUI 1 AUI 2 AUI 3 AUI 4

By default, the Total Connect (virtual) keypad will
be set to address 2 in the communicator programmin
g. The
suggested input of 1,5,0,0 assumes this programming
has been left at default and also assumes you have
a
touchscreen keypad installed for partition 1 at add
ress 1. See panel programming documentation for oth
er
valid inputs.
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
(B)
A
D
S
ENTER
SHIFT
N / Y
/
BS/ESC
SPACE
B
E
T
C
F
X
#
ARMED
READY
6160-7720P-001-V0
SHIFT
FUNCTION
WHEN LIT
(C)
(D)
(A)


Uploaded