DOCUMENTATION Limitations of the Alarm System or Device
This quick start guide is NOT a substitute for the
EA
Pro
®

User Manual. All documentation related to
operations should be followed. For further guidelines and safety information, please read the entire
EA
Pro
®
User Manual prior to installation and operation of this unit.
While your alarm system or device is reliable and sophisticated, it does not offer guaranteed
protection against burglary, fire or other emergencies. Any security product, whether commercial
or residential, is subject to compromise or failure-to-warn for a variety of reasons.
This equipment, like other electrical devices, is subject to component failure.
The most common cause of a system not functioning properly is due to
inadequate maintenance. Your system should be tested weekly to make sure all detection
devices are operating properly. Your control panel and keypads should be tested as well.
Images and software are subject to change.
For the most up-to-date information, please use the QR code provided above.
eapro.winland.com 4.7”
TOUCHSCREEN
AC
CEPT/HOME
LIGHT LED
INCREASE
DECREASE
CANCEL/SILENCE
FRONT PANEL BACK PLATE
OUT #
1
INPUT #4
INPUT #3
INPUT #2
INPUT #1
OUT #
2
OUT #
3
OUT #
4
(-) (+)
(-)
(+)
(-)
(+)
(-)
(+)
(-)
(+)
PWR IN
(-) (+)
PWR OUT
UPS BA
TT
ER
Y
POWER C
ONNECT
IONS
RELAY
OUTPUTS
SENSOR INPUTS
PWR ON
OUT #
5 POWER ON
1.
Zip tie UPS Battery to PCB.
2.
Connect the UPS Battery to the
MOLEX connection on the PCB.
3.
Ensure POWER SWITCH, is in the
DOWN (OFF) position.
4.
Connect either PoE cable to the RJ45
connector or 12~24V DC @1A power to
the PWR IN terminal block. Both can
be connected at the same time for
redundancy.
5.
Adjust POWER SWITCH f rom OFF to
ON.
IMPORTANT!
Incorrect polarity can cause personal
injury and / or damage to the unit.
PWR ON
(-) (+)
PWR IN
(-) (+)
PWR OUT
UPS BA
TT
ER
Y
POWER C
ONNECT
IONS
PoE RJ45
POWER SWIT
CH 5:51 P
M
BACK
CO
NFIRM
LOGI
N
SUPER ADMI
N
-
.
CANCEL
CLEAR
ENTER
UNLOCK
DEFAULT PIN: 1234
To UNLOCK the
EA
Pro
®-Gateway
, press the
LOCK ICON.
Press BLUE Button next to USERNAME to
select USERNAME, then repeat for PIN.
Enter the PIN using the keypad.
1
2
3
4
5
6
7
8
9
0
+
7 Jan 2021
5:51 PM (CST
)
NO SENSORS
LO
CK IC
ON
HOME
MENU HARDWIRE SENSOR (BLUE) TEMP-L-S
MENU
>
SENSORS
>
ADD SENSOR
>
HARDWIRE
>


SELECT SENSOR INPUT
>
NOTE
Device MUST be unlocked to program/edit/delete
sensors. Not all screens are shown in the quick start
guide. RF Sensor similar to HARDWIRE.
NOTIFI
CA
TION
LOGS
DA
TA
LOGS
SENSORS
SYS
TEM
RELA
YS
USERS
NETW
ORK
REBOOT
ABOUT
5:51 P
M
MAIN MENU
UNLO
CKED
5:51 P
M
SENSOR TY
PE & NAM
E
DROP DO
WN
PROBE TY
PE
NAM
E
DROP DOW
N
IN MINU
TES
COLLECTION
FREQUEN
CY
BACK
CO
NFIRM
DROP DO
WN
DEFAULT
SETTING NAME
PROBE TYPE
>
NAME
>
COLLECTION FREQUENCY
>

CONFIRM
NOTE
PROBE TYPE is based on your probe/sensor model.
Output will be incorrect if the wrong type is
programmed. NAME can be toggled for common or
custom names. COLLECTION FREQUENCY will
determine sensor logs history.
Winland recommends 15 minutes as a baseline. HARDWIRE SENSOR (BLUE) TEMP-L-S
LOW LIMIT: Absolute low value to trigger alarm. Select
which RELAY will activate signal.
LOW LIMIT DELAY: Requires time value for alarm to
become active.
NOTE
Not all of the settings are required to program a sensor.
5:51 P
M
SENSOR LO
W LIMITS
ON - OFF
SETTING NAM
E
SET POIN
T
SELEC
T
REL
AY
LO
W LIMI
T
15
IN MINU
TES
LO
W LIMIT DELA
Y
RELA
Y 1 *
LO
W W
ARNING
15
IN MINU
TES
LO
W W
ARNING
DELA
Y
BACK
CO
NFIRM
15.0
17.0
NOTE
WARNING and LIMITS are a dual system notification.
Both can toggle indepentent notifications/relays.
TOGGLE UNIT OF MEASURE
>
TOGGLE TO ENABLE
LIGHTS AND / OR BUZZER
IF DESIRED

>
CONFIRM
>

TOGGLE RELAYS AND LIGHT
IF DESIRED
>
CONFIRM
>
NOTE
Mutiple set points can trigger the same relay.
5:51 P
M
SENSOR GENERAL
SET POIN
T
FAHRENHEI
T
UNIT OF MEASURE
0.1
HY
STERESI
S
LIGHTS
ON
BUZZER
BACK
CO
NFIRM
ON
DEFAULT
SETTING NAME HOME
Cooler #
1
8.1 ̊C
6.31
6.1
LO
W
4.0
HIGH
12.0
7 Jun 2022
5:51:52 PM
SENSOR READIN
G
SENSOR L
OG
S
MIN & MA
X
LIMITS
HOME SCREEN
SENSOR is added. Select ADD ANOTHER SENSOR,
ADJUST SENSOR DETAILS, HOME to view sensor
information, or DELETE SENSOR to remove a sensor.
5:51 P
M
SENSOR ADDED
SENSOR ADDED!
ADD ANOTHER
SENSOR
AD
JUST SENSO
R
DETA
ILS
HOME
DELETE SENSO
R
NOTE
Repeat process for HIGH LIMITS and HIGH WARNINGS.
NOTE
HOME is the default view once a sensor has been
programmed.
LOW and HIGH limits are based on absolute limit and
NOT on warnings.
MIN & MAX will auto clear on reboot, and can be
manually cleared.
MIN
MAX HOME SCREEN
NOTE
Each sensor is programmed independantly. Thus, not all
colors will reflect for each sensor.
NOTE
LATCHED relays are not commonly used, and will only
be seen if a relay is programmed to be latched.
Normal

Co
nditio
n
Wa
rnin
g
Co
nditio
n
Relay La
tche
d
Co
nditio
n
Alar
m
Co
nditio
n
W
ARNING DELA
Y
ALARM DEL
AY
LA
TCHED REL
AY
ACTIVE A
LARM
ICON
S HOME SCREEN
COOLER #1
Within parameters. Pending Warning Condition (delay
active). Warning limits set points will NOT be on display.
COOLER #2
Warning Condition. Pending Alarm Condition (delay
active).
UTIL ROOM
Within parameters after an Alarm Condition has
cleared, the relay is still latched. Manual clear is
required for relay to stop sending an Alarm Condition.
WEST COOLER
WEST COOLER: Active Alarm Condition.
HOM
E
Cooler #
1
8.1 ̊C
MI
NM
AX
6.31
6.1
LO
W
4.0
HIGH
12.0
Cooler #
2
8.1 ̊C
MA
X
MI
N
8.1
1.5
LO
W
2.0
HIGH
7.0
We
st C
ooler
50.2 ̊
F
MI
NM
AX
34
.2
67
.3
LO
W
33.0
HIGH
48
.0
Util Room
93.1 PSi
MI
NM
AX
8.91
20
.3
LO
W
10.0
HIGH
180.
0
7 Jun 2022
5:51:52 PM 5:51 P
M
NETW
ORK - HARDW
IRE
SETTING NAM
E
SET POIN
T
DISABLED
DHCP
IP
255.255.255.
0
SUBNET
192.
168.
0.10
PRIMARY DNS
BACK
CO
NFIR
M
192.
168.
0.101
-
.
CANCEL
CLEAR
ENTER
NETWORK ETHERNET
MENU NETWORK
>
EDIT ETHERNET
>
Enable/Disable DHCP
>
Follow prompt to enter IP settings
>
CONFIRM
>
Press OK on prompt.
NOTE
Ensure the Network Toggle is set properly for your
application. WI-FI Progamming similar.
1
2
3
4
5
6
7
8
9
0
+
OUT #1
INPUT #4
INPUT #3
INPUT #2
INPUT #1
OUT #1
OUT #1
OUT #1
OUT #1
PWR ON
(-) (+)
(-)
(+)
(-)
(+)
(-)
(+)
(-)
(+)
PWR IN
(+) (-)
PWR OU
T
WI-FI Chi
p
NE
TWORK T
OGGLE
PoE RJ45

WI-F
I
Chip
WI-F
I
RJ45 INSIGHT
MENU
>
NETWORK
>
CLOUD ENABLE
>
SYNC (select
option)
>
CONFIRM. Press OK on Prompt.
SN & Key provided at: MENU
>
ABOUT
>
CONFIRM.
Log into
INSIGHT
: www.winlandinsight.com
Use the SN&KEY provided to:
Account Administration > Add Device
NOTE
INSIGHT
is a subcription based system. It is not
required to operate this device. For more information
about
INSIGHT
:
SN: 000-0AB8C
KE
Y: 41FA-
9A
11
BACK
XX
:XX:XX
:XX:XX
:XX
XX
:XX:XX
:XX:XX
:XX
ETHERNET MA
C
WI
FI:
192.
168.
0.1
255.255.255.
0
192.
168.
0.10
8.8.8.
8
192.
168.
0.10
192.
168
.0.
2
CO
NFIRM
Guides INFORMATION
For the complete
EA
Pro
®
User Manual,
including product specifications,
user-interface details, and warranty
details, please follow the QR code:
http://manual.eapro.winland.com