DSC HSM3105 MX Addressable Loop Module - Install Guide - Dated 2022 R001



Related Products

DSC HSM3105 - MX Wired Zone Expander for Qolsys IQ Pro
DSC HSM3105
MX Wired Zone Expander for Qolsys IQ Pro
List Price:
Our Price: $179.99

Document Transcript

*29011148R001*
HSM3105
© 2022 Johnson Controls. All rights reserved.
HSM3105 Expansion Module Installation
Guide
29011148R001 2
HSM3105 Expansion Module Installation Guide
© 2022 Johnson Controls. All rights reserved. Contents
Contents
MX expander.....................................................................................................................................................5
Compatible devices..........................................................................................................................................5
Specifications
....................................................................................................................................................5
Familiarization with the HSM3105 module
................................................................................................... 6
Terminal descriptions............................................................................................................................6
Compatibility
.......................................................................................................................................... 7
System configuration............................................................................................................................ 7
Low power mode..........................................................................................................................................7
High power mode – external mount..........................................................................................................9
MX addressable loop wiring configuration...................................................................................... 10
Current Loading on the MX Loop.................................................................................................................11
MX Bus Wire Length.......................................................................................................................................12
Enclosures.......................................................................................................................................................13
Automatically enrolling on the alarm panel............................................................................................... 14
Status LED
....................................................................................................................................................... 14
Firmware update indications............................................................................................................. 14
MX diagnostics
................................................................................................................................................15
Limited Warranty............................................................................................................................................15
Software Product License..............................................................................................................................15
FCC and ISED Canada Information.............................................................................................................. 18
Modification statement
.......................................................................................................................18
FCC class B digital device notice........................................................................................................ 18
© 2022 Johnson Controls. All rights reserved.
HSM3105 Expansion Module Installation Guide
3 4
HSM3105 Expansion Module Installation Guide
© 2022 Johnson Controls. All rights reserved. MX expander
HSM3105 is an expansion module intended to provide MX addressable device expansion to IQ Pro
and IQ Pro P Panel. The module connects to the panel using the Corbus interface and provides
connectivity for two 2 wire MX addressable buses that devices are connected to. The two MX buses
which are left and right can be configured to operate as a single loop or as separate left and right
spurs.
Note:
The reference in this manual to model IQ Pro is also representative for model IQ Pro P
unless stated differently.
Compatible devices
The following wired devices and modules are compatible with the HSM3105.
Table 1:
HSM3105 compatible devices
Model
Name
Standby current
(mA)
Alarm current
(mA) (including
LED as applicable)
MX945
Addressable universal input devices
0.46
4.50
MX916
Addressable smoke heat detector with
base
0.35
4.00
MX862
Addressable ceiling mount PIR
0.30
3.50
MX920
Line isolator module
0.09
16.00
MX922
Addressable glassbreak
0.30
6.00
MX926
Addressable smoke detector with base
0.35
4.00
MX936
Addressable heat detector with base
0.35
4.00
MX975
Addressable door/window contact
sensor
0.20
3.00
MX974
Addressable PIR with animal immunity
0.30
3.50
MXBASE
Addressable 4” continuity fire base
N/A
N/A
Note:
For the MX920 device, the alarm current (16mA) is due to a loop fault. This fault occurs
when the isolator is triggered. (loop in short condition)
Specifications

Temperature range: -10°C to + 55°C
• Relative Humidity: 5% to 93% RH non-condensing

Input rating: 11.3 to 12.5 VDC / 350 mA to 325 mA (provided by the alarm controller)
Note:
Higher loading is possible when using a separate power supply, refer to further
instructions in this manual. For details of the maximum loading of the MX loop refer to
the MX loop maximum loading table below.

Board current draw: 100 mA (with no devices on the MX loop) + MX Loop current draw
(depending on the connected loop devices)
5
HSM3105 Expansion Module Installation Guide
© 2022 Johnson Controls. All rights reserved. •
Board dimensions: 83 mm x 145 mm (3.25 in x 5.7 in)

Corbus wire distance: 3 ft Max between the panel and the module

The ROHS compliant hardware.

This equipment must be installed by skilled service persons in non-hazardous, indoor
locations.

You can add a maximum of 126 devices to the HSM3105. Refer to the spreadsheet linked in the
Current Loading on the MX Loop
section of this document for the accurate number of devices
that can be enrolled based on current availability.
Table 2: MX Loop maximum loading @ 40V
Application
Standby time +
alarm
4Ah
7Ah
17Ah
Resi fire/ULC Com
burg
24 h + 5 min
-
50 mA
170 mA
Resi/Com burg
4 h + 15 min
230 mA
400 mA
400 mA
Note:
For applications where the MX loop current loading exceeds 67 mA @ 40 V, use
approved external power supply models HSM2300 or HSM2204. See the
System configuration
section for details.
Familiarization with the HSM3105 module
This section provides details about the HSM3105 in relation to terminal descriptions, module
compatibility, system configuration, and MX addressable loop wiring configurations.
Terminal descriptions
TMP- Used to connect to the tamper switch that protects against the unauthorized opening of the
enclosure the HSM3105 is mounted in. Connect a normally closed (NC) switch across +TMP and -
TMP. If the tamper is not being used, connect a piece of wire across +TMP and -TMP to remove the
trouble condition.
Note:
Tamper protection is required for UL/ULC commercial/residential burglary installations.
There are LFT and RGT terminals for the MX Loop connection that are used to connect the
compatible MX Devices. Each Loop has + and - terminals. Refer to
MX addressable loop wiring
configuration for further information.
CORBUS - The panel uses the 4-wire Corbus to communicate with the module. Connect the RED,
BLK, YEL and GRN terminals to the Corbus terminals on the IQ Pro main control.
HSM3105 Expansion Module Installation Guide
6
© 2022 Johnson Controls. All rights reserved. Callout
Component
A
Mounting hole
B
Status LED
C
Earth Ground connection. The IQ Pro panel and HSM3104 module shall both be
connected to the same earth ground.
Compatibility
The table below outlines the HSM3105 module compatibility.
Table 3: Compatibility
Component
Compatibility details
Panel Compatibility
IQ Pro and IQ Pro P
Enclosure Compatibility
The module can be installed in the same enclosure with IQ Pro (if it is
a metal configuration enclosure) or by itself in any of the following,
separately listed compatible enclosures: HSC3010C, HSC3010CR,
HSC3030CAR, HSC3020C, HSC3001C, HSC3001CP, PC4050CAR,
PC4050CR, PC5003C.
Connectivity Compatibility
Corbus
Auxiliary Power Supply
HSM2300, HSM2204
System configuration
Low power mode
You can mount the HSM3105 in an IQ Pro enclosure (metal configuration only) or in a separate
enclosure (See
Enclosures) from the control panel, as shown in Figure 1 and 2 respectively. The
Corbus wire runs between the control panel and the HSM3105 and shall not exceed 3ft using
22AWG wire.
7
HSM3105 Expansion Module Installation Guide
© 2022 Johnson Controls. All rights reserved. The MX loop is powered from the Corbus supply power, and can have a maximum MX loop current
draw of 67 mA @ 40 V (equivalent to 360 mA @11.3 V or 325 mA @ 12.5 V)
Figure 1:
Low power mode – internal mount
AC mains
Power
adapter
IQ Pro/IQ Pro P
CORBUS
MX loop
IQ Pro/IQ Pro P enclosure
HSM3105
Figure 2:
Low Power Mode – External Mount
AC mains
Power
adapter
IQ Pro/IQ Pro P
CORBUS
MX loop
IQ Pro/IQ Pro P enclosure
HSM3105
HSM3105 enclosure
HSM3105 Expansion Module Installation Guide
8
© 2022 Johnson Controls. All rights reserved. High power mode – external mount
Only mount the HSM3105 module in an external enclosure (See
Enclosures) along with one of
the following approved auxiliary power supply units: HSM2204, HSM2300. The power supply unit
provides power to the HSM3105 module and the MX loop. The Corbus wire runs between the
control panel and the HSM3105 must not exceed 3ft using 22AWG wire.
The HSM3105 is designed to handle a maximum allowable MX loop current draw of 400 mA @ 40
V (equivalent to 1600 mA @11.3 V or 1500 mA @ 12.5 V). Check the manual for the chosen power
supply unit to understand how much current would be available for the MX loop.
Note:
HSM2300 and HSM2204 can only provide up to 228 mA @ 40 V (1000 mA @ 12.5 V) or 260
mA @ 40 V (1000 mA @ 11.3 V)
Figure 3:
High Power Mode – External Mount
AC mains
Power
adapter
IQ Pro/IQ Pro P
CORBUS
MX loop
IQ Pro/IQ Pro P enclosure
HSM3105
HSM3105 enclosure
HSM2300
HSM2204
BATTERY
AC mains
Power
adapter
Figure 4:
High Power Mode - wiring diagram
18VDC
+ -
+ -
+ -
+ -
BELL
CORBUS
AUX 1
AUX 2

RED BLK YEL GRN

RED BLK YEL GRN

AC AC AUX+ RED BLK YEL GRN TAM 01 02 03 04
IQ Pro/IQ Pro P Control Panel
HSM2204/HSM2300 Power Supply
HSM3105 MX Addressable Interface
9
HSM3105 Expansion Module Installation Guide
© 2022 Johnson Controls. All rights reserved. MX addressable loop wiring configuration
The HSM3105 supports two wire and four wire wiring configurations. You can configure the
HSM3105 to manage a spur or two wire wiring scheme. See
Figure 5.
Figure 5:
Two wire wiring
Figure 6:
Four wire wiring
You can configure a HSM3105 module using a loop configuration or four wire wiring. See
Figure
6. In the case of a single wiring trouble, for example a cable break or short circuit trouble, all the
devices can still be managed, depending on the isolators that are present on the loop.
Configure the MX loop by selecting the spur for two wire configuration and loop for a four wire
configuration with the IQ Pro installer app.
1.
Open the IQ Pro installer app.
2. Select
Installation
>
Devices
>
Security Sensors
>
MX Module.
3. Click
Configuration.
4. Click
Bus Configuration
and select the required Spur or Loop configuration based on the site
requirement.
HSM3105 Expansion Module Installation Guide
10
© 2022 Johnson Controls. All rights reserved. Figure 7:
Line T- Tapping
If multiple spurs are required for the installation, then you can use multiple MX920 Isolator
modules. These spurs can be applied to either two wire or four wire MX loop configurations. Refer
to the MX920 manual for more details on the isolator modules. See
Figure 7.
You can now wire the MX devices to the HSM3105 based on the chosen configuration.
Current Loading on the MX Loop
The following information describes the HSM3105 MX Loop Current Load Calculator tool provided
to calculate the current loading on the MX loop.
Note:
To use this tool, the installer will require access to Microsoft Excel or an equivalent
spreadsheat reader.
The linked spreadsheet must be used as a tool by the installer to properly calculate the current load
on the MX loop and avoid overloading the system. Further details and instructions can be found on
the spreadsheet at. www.dsc.com/29011178
The spreadsheet allows the installer to:
1.
input the MX devices that will be installed
2.
define the system configuration (low power or high power mode) as well as the auxiliary
power supply unit used (for high power mode only)
3.
specify the expected maximum percentage of devices that can turn ON the Alarm LED at the
same time.
The output would be the current loading on the MX loop and the percentage of max load used.
The installer can pick and choose which MX devices to be added/removed on the MX loop to avoid
overloading the system.
11
HSM3105 Expansion Module Installation Guide
© 2022 Johnson Controls. All rights reserved. For the MX920 device, the loop fault current (16mA) occurs when the isolator is triggered (loop in
short condition). As a result, the MX loop Current Load Calculator tool does not account for this
value during alarm current calculation. The installer must account for this fault separately.
MX Bus Wire Length
The following table outlines the maximum MX bus wire length that can be used depending
on the maximum load on the MX loop (obtained from the load calculation spreadsheet, using
the maximum value between inrush current or alarm current) and the wire gauge used in the
installation.
Table 4:
Max. MX Bus Wire Length
Max. allowable wire pair length
LOOP
maximum
loads (mA)
Cable 2.5
square mm
14AWG (2.08
mm2)
16AWG (1.31
mm2)
18AWG
(0.823 mm2)
20AWG
(0.518 mm2)
22AWG
(0.324 mm2)
10
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
20
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
30
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
40
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
50
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
60
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
70
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
5732 FT 1745
m
80
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
5015 FT 1527
m
90
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
4458 FT 1358
m
100
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6404 FT 1952
m
4012 FT 1222
m
110
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
5822 FT 1772
m
3648 FT 1111
m
120
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
5337 FT 1627
m
3344 FT 1018
m
130
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
6435 FT 1961
m
4926 FT 1502
m
3086 FT 940
m
140
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
5975 FT 1821
m
4574 FT 1394
m
2866 FT 873
m
HSM3105 Expansion Module Installation Guide
12
© 2022 Johnson Controls. All rights reserved. Table 4:
Max. MX Bus Wire Length
Max. allowable wire pair length
150
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
5577 FT 1699
m
4269 FT 1301
m
2675 FT 815
m
160
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
5228 FT 1593
m
4002 FT 1220
m
2508 FT 764
m
170
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
4921 FT 1499
m
3767 FT 1148
m
2360 FT 719
m
200
6562 FT 2000
m
6562 FT 2000
m
6562 FT 2000
m
4183 FT 1275
m
3202 FT 976
m
2006 FT 611
m
250
6562 FT 2000
m
6562 FT 2000
m
5317 FT 1625
m
3346 FT 1020
m
2562 FT 781
m
1605 FT 489
m
300
6562 FT 2000
m
6562 FT 2000
m
4431 FT 1354
m
2789 FT 850
m
2135 FT 651
m
1337 FT 407
m
350
6562 FT 2000
m
6049 FT 1839
m
3798 FT 1161
m
2390 FT 728
m
1830 FT 558
m
1146 FT 349
m
400
6562 FT 2000
m
5293 FT 1609
m
3323 FT 1026
m
2091 FT 637
m
1601 FT 488
m
1003 FT 305
m
Note:
The table above was calculated considering a maximum voltage drop on the loop of 13
V. The burglary devices can house a maximum cable section of 16AWG.
Enclosures
The HSM3105 must be installed within 3ft of the panel. For high power mode, a separate enclosure
(listed below) must be used. For low power mode, there is an option to use an internal mount
(inside the IQ Pro metal enclosure) or a external mount (using one of the enclosures listed below).
The plastic enclosure configuration for the IQ Pro P does not support the installation of HSM3105
inside the cabinet and a separate enclosure must be used. Internal and/or external wiring for this
module must be routed, supported, clamped or secured in a manner that reduces the likelihood of
excessive strain on wire and terminal connections, loosening of terminal connections, and damage
of conductor insulation.
The HSM3105 can be installed in the enclosures listed below. Tamper protection switches can
be installed on all enclosures, including door opening protection or removal from the mounting
position. Doors can be secured using screws or keylock.
• Model HSC3010C (hinged door) made of 18 Ga steel, painted white, dimensions 372 mm x 412
mm x 114 mm , weight: 9.75 lb or 4.2 Kg

Model HSC3010CR (hinged door) made of 18 Ga steel, painted red, dimensions 372 mm x 412
mm x 114 mm, weight: 10.0 lb or 4.5 Kg
• Model HSC3030CAR (hinged door) made of 18 Ga steel (base) and 16 Ga (door), painted white,
dimensions 375 mm x 412 mm x114 mm, weight 11.45 lb or 5.2 Kg

Model HSC3020C (removable door) made of 18 Ga steel, painted white, dimensions 459 mm x
414 mm x 103 mm, weight: 11.5 lb or 4.3 Kg
• Model HSC3001C (hinged door) made of 22Ga steel, dimension 260mm x 237 mm x 69 mm,
weight 1.2kg
13
HSM3105 Expansion Module Installation Guide
© 2022 Johnson Controls. All rights reserved. •
Model HSC3001CP (removable cover) made of ABS, color white, dimensions 254 mm x 177.8
mm x 62 mm, weight: 350g

Model HSC3020CP (removable door) made of PC-ABS, color white, dimensions 368 mm x 489
mm x 108 mm, weight: 4.7 lb or 2.1 Kg
• Model PC4050CAR - Made of 18Ga steel, painted. 376 mm x 305 mm x 125mm
• Model PC4050CR - Made of 18Ga steel, painted. 376 mm x 305 mm x 128mm
• Model PC5003C - Made of 22Ga steel, painted. 288 mm x 298mm x 78mm
Automatically enrolling on the alarm panel
To enroll the HSM3105, complete the following steps:
1.
Ensure that the system is not powered.
2. Connect the HSM3105 to the Corbus.
3.
Power up the system.
4. Open the IQ installer app.
5.
Tap
Installation
>
Devices
>
Security Sensors
>
Add Device
>
Autolearn
>
Start Autolearn
.
Result
This HSM3105 module is enrolled on the panel.
What to do next:
After the MX module is enrolled and the loop configuration settings are complete, see MX
addressable loop wiring configuration, open the installer app, go to
Installation > Devices >
Security Sensors > Add Device "+" > Autolearn + MX > Start Autolearn
. This enrolls all of the
MX devices connected to the HSM3105. When enrollment of all the MX devices connected has
completed, the IQ Installer app shows this message:
MX Autoenrollment completed
.
Status LED
The HSM3105 is equipped with a status LED to indicate the current condition of the module. If the
HSM3105 is operating correctly, the status LED flashes 120 ms ON and 10 seconds OFF. When a
trouble condition is present, the status LED displays a series of flashes then remains blank for 1.7
seconds. The number of flashes indicates the trouble condition as outlined below.
Number of Flashes
Trouble Condition
1
Module not enrolled
2
Alarm Panel supervision trouble
3
Corbus low voltage
7
MX bus fault
8
Device trouble (this status is indicated if there are troubles with an MX Device.
Firmware update indications
During a firmware upgrade process the Status LED flash: 800 ms on / 800 ms off This cadence
shall clear at the end of the firmware upgrade process. If the firmware upgrade fails, the status
LED flash: 200 ms on / 200 ms off. This cadence shall clear when the firmware upgrade process is
reattempted
HSM3105 Expansion Module Installation Guide
14
© 2022 Johnson Controls. All rights reserved. MX diagnostics
Access MX diagnostics in the installer app.
1. Open the IQ installer app.
2.
Tap
Installation
>
Devices
>
Security Sensors
>
MX module
>
Diagnostics
.
3.
For a device count, tap
Run
.
4.
For noise level in the MX Loop, tap
Run
.
5.
For smoke and heat diagnostics, tap
Run
.
Limited Warranty
Digital Security Controls (DSC) warrants that for a period of twelve months from the date of purchase, the
product shall be free of defects in materials and workmanship under normal use and that in fulfilment of any
breach of such warranty, DSC shall, at its option, repair or replace the defective equipment upon return of the
equipment to its factory. This warranty applies only to defects in parts and workmanship and not to damage
incurred in shipping or handling, or damage due to causes beyond the control of DSC such as lightning, exces-
sive voltage, mechanical shock, water damage, or damage arising out of abuse, alteration or improper applica-
tion of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other
warranties, whether expressed or implied and of all other obligations or liabilities on the part of DSC. This war-
ranty contains the entire warranty. Digital Security Controls neither assumes responsibility for, nor authorizes
any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any
other warranty or liability concerning this product. In no event shall DSC be liable for any direct or indirect or
consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in
connection with the purchase, installation or operation or failure of this product.
WARNING:
Digital Security Controls recommends that the entire system be completely tested
on a regular basis. However, despite frequent testing, and due to, but not limited to, criminal
tampering or electrical disruption, it is possible for this product to fail to perform as expected.
IMPORTANT - READ CAREFULLY: DSC Software purchased with or without Products and Components is copy-
righted and is purchased under the following license terms:
This End-User License Agreement (“EULA”) is a legal agreement between You (the company, individual or enti-
ty who acquired the Software and any related Hardware) and Digital Security Controls, a division of Tyco Safe-
ty Products Canada Ltd. (“DSC”), the manufacturer of the integrated security systems and the developer of
the software and any related products or components (“HARDWARE”) which You acquired. If the DSC software
product (“SOFTWARE PRODUCT” or “SOFTWARE”) is intended to be accompanied by HARDWARE, and is NOT
accompanied by new HARDWARE, You may not use, copy or install the SOFTWARE PRODUCT. The SOFTWARE
PRODUCT includes computer software, and may include associated media, printed materials, and “online” or
electronic documentation. Any software provided along with the SOFTWARE PRODUCT that is associated with a
separate end-user license agreement is licensed to You under the terms of that license agreement.
By installing, copying, downloading, storing, accessing or otherwise using the SOFTWARE PRODUCT, You agree
unconditionally to be bound by the terms of this EULA, even if this EULA is deemed to be a modification of any
previous arrangement or contract. If You do not agree to the terms of this EULA, DSC is unwilling to license the
SOFTWARE PRODUCT to You, and You have no right to use it.
Software Product License
The SOFTWARE PRODUCT is protected by copyright laws and international copyright treaties, as well as other
intellectual property laws and treaties. The SOFTWARE PRODUCT is licensed, not sold.
1. GRANT OF LICENSE This EULA grants You the following rights:
(a) Software Installation and Use - For each license You acquire, You may have only one copy of the SOFTWARE
PRODUCT installed.
(b) Storage/Network Use - The SOFTWARE PRODUCT may not be installed, accessed, displayed, run, shared or
used concurrently on or from different computers, including a workstation, terminal or other digital electronic
device (“Device”). In other words, if You have several workstations, You will have to acquire a license for each
workstation where the SOFTWARE will be used.
15
HSM3105 Expansion Module Installation Guide
© 2022 Johnson Controls. All rights reserved. (c) Backup Copy - You may make back-up copies of the SOFTWARE PRODUCT, but You may only have one copy
per license installed at any given time. You may use the back-up copy solely for archival purposes. Except as
expressly provided in this EULA, You may not otherwise make copies of the SOFTWARE PRODUCT, including the
printed materials accompanying the SOFTWARE.
2. DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS
(a) Limitations on Reverse Engineering, Decompilation and Disassembly - You may not reverse engineer, de-
compile, or disassemble the SOFTWARE PRODUCT, except and only to the extent that such activity is expressly
permitted by applicable law notwithstanding this limitation. You may not make any changes or modifications
to the Software, without the written permission of an officer of DSC. You may not remove any proprietary no-
tices, marks or labels from the Software Product. You shall institute reasonable measures to ensure compli-
ance with the terms and conditions of this EULA.
(b) Separation of Components - The SOFTWARE PRODUCT is licensed as a single product. Its component parts
may not be separated for use on more than one HARDWARE unit.
(c) Single INTEGRATED PRODUCT - If You acquired this SOFTWARE with HARDWARE, then the SOFTWARE PROD-
UCT is licensed with the HARDWARE as a single integrated product. In this case, the SOFTWARE PRODUCT may
only be used with the HARDWARE as set forth in this EULA.
(d) Rental - You may not rent, lease or lend the SOFTWARE PRODUCT. You may not make it available to others
or post it on a server or web site.
(e) Software Product Transfer - You may transfer all of Your rights under this EULA only as part of a permanent
sale or transfer of the HARDWARE, provided You retain no copies, You transfer all of the SOFTWARE PRODUCT
(including all component parts, the media and printed materials, any upgrades and this EULA), and provided
the recipient agrees to the terms of this EULA. If the SOFTWARE PRODUCT is an upgrade, any transfer must al-
so include all prior versions of the SOFTWARE PRODUCT.
(f) Termination - Without prejudice to any other rights, DSC may terminate this EULA if You fail to comply with
the terms and conditions of this EULA. In such event, You must destroy all copies of the SOFTWARE PRODUCT
and all of its component parts.
(g) Trademarks - This EULA does not grant You any rights in connection with any trademarks or service marks
of DSC or its suppliers.
3. COPYRIGHT - All title and intellectual property rights in and to the SOFTWARE PRODUCT (including but not
limited to any images, photographs, and text incorporated into the SOFTWARE PRODUCT), the accompanying
printed materials, and any copies of the SOFTWARE PRODUCT, are owned by DSC or its suppliers. You may not
copy the printed materials accompanying the SOFTWARE PRODUCT. All title and intellectual property rights in
and to the content which may be accessed through use of the SOFTWARE PRODUCT are the property of the re-
spective content owner and may be protected by applicable copyright or other intellectual property laws and
treaties. This EULA grants You no rights to use such content. All rights not expressly granted under this EULA
are reserved by DSC and its suppliers.
4. EXPORT RESTRICTIONS - You agree that You will not export or re-export the SOFTWARE PRODUCT to any
country, person, or entity subject to Canadian export restrictions.
5. CHOICE OF LAW - This Software License Agreement is governed by the laws of the Province of Ontario,
Canada.
6. ARBITRATION - All disputes arising in connection with this Agreement shall be determined by final and bind-
ing arbitration in accordance with the Arbitration Act, and the parties agree to be bound by the arbitrator’s de-
cision. The place of arbitration shall be Toronto, Canada, and the language of the arbitration shall be English.
Limited Warranty
(a) NO WARRANTY - DSC PROVIDES THE SOFTWARE “AS IS” WITHOUT WARRANTY. DSC DOES NOT WARRANT
THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS OR THAT OPERATION OF THE SOFTWARE WILL BE
UNINTERRUPTED OR ERROR-FREE.
(b) CHANGES IN OPERATING ENVIRONMENT - DSC shall not be responsible for problems caused by changes in
the operating characteristics of the HARDWARE, or for problems in the interaction of the SOFTWARE PRODUCT
with non-DSC-SOFTWARE or HARDWARE PRODUCTS.
(c) LIMITATION OF LIABILITY; WARRANTY REFLECTS ALLOCATION OF RISK - IN ANY EVENT, IF ANY STATUTE IM-
PLIES WARRANTIES OR CONDITIONS NOT STATED IN THIS LICENSE AGREEMENT, DSC’S ENTIRE LIABILITY UN-
DER ANY PROVISION OF THIS LICENSE AGREEMENT SHALL BE LIMITED TO THE GREATER OF THE AMOUNT AC-
TUALLY PAID BY YOU TO LICENSE THE SOFTWARE PRODUCT AND FIVE CANADIAN DOLLARS (CAD$5.00). BE-
CAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUEN-
TIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
(d) DISCLAIMER OF WARRANTIES - THIS WARRANTY CONTAINS THE ENTIRE WARRANTY AND SHALL BE IN LIEU
OF ANY AND ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED (INCLUDING ALL IMPLIED WAR-
RANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE) AND OF ALL OTHER OBLIGATIONS
OR LIABILITIES ON THE PART OF DSC. DSC MAKES NO OTHER WARRANTIES. DSC NEITHER ASSUMES NOR AU-
THORIZES ANY OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MODIFY OR TO CHANGE THIS WAR-
RANTY, NOR TO ASSUME FOR IT ANY OTHER WARRANTY OR LIABILITY CONCERNING THIS SOFTWARE PROD-
UCT.
(e) EXCLUSIVE REMEDY AND LIMITATION OF WARRANTY - UNDER NO CIRCUMSTANCES SHALL DSC BE LIABLE
FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT DAMAGES BASED UPON BREACH OF WAR-
HSM3105 Expansion Module Installation Guide
16
© 2022 Johnson Controls. All rights reserved. RANTY, BREACH OF CONTRACT, NEGLIGENCE, STRICT LIABILITY, OR ANY OTHER LEGAL THEORY. SUCH DAM-
AGES INCLUDE, BUT ARE NOT LIMITED TO, LOSS OF PROFITS, LOSS OF THE SOFTWARE PRODUCT OR ANY
ASSOCIATED EQUIPMENT, COST OF CAPITAL, COST OF SUBSTITUTE OR REPLACEMENT EQUIPMENT, FACILITIES
OR SERVICES, DOWN TIME, PURCHASERS TIME, THE CLAIMS OF THIRD PARTIES, INCLUDING CUSTOMERS, AND
INJURY TO PROPERTY. WARNING: DSC recommends that the entire system be completely tested on a regular
basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical disrup-
tion, it is possible for this SOFTWARE PRODUCT to fail to perform as expected.
17
HSM3105 Expansion Module Installation Guide
© 2022 Johnson Controls. All rights reserved. FCC and ISED Canada Information
This information applies to model HSM3105.
Modification statement
Tyco Safety Products Canada Ltd. has not approved any changes or modifications to this device by
the user. Any changes or modifications could void the user’s authority to operate the equipment.
Tyco Safety Products Canada Ltd. n’approuve aucune modification apportée à l’appareil par
l’utilisateur, quelle qu’en soit la nature. Tout changement ou modification peuvent annuler le droit
d’utilisation de l’appareil par l’utilisateur.
FCC class B digital device notice
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.

Consult the dealer or an experienced radio/TV technician for help.
ISED Canada
CAN ICES-3(B)/NMB-3(B)
© 2022 Johnson Controls. All rights reserved.


Uploaded