MXBASE AND MX916/926/936 FIRE
DEVICES INSTALLATION INSTRUCTIONS
29011151R001 2
MXBASE AND MX916/926/936 FIRE DEVICES INSTALLATION INSTRUCTIONS Contents
Contents
Cautions, warnings, and regulatory information.........................................................................................5
Introduction......................................................................................................................................................6
MXBASE installation......................................................................................................................................... 7
Device settings..................................................................................................................................................9
MXBASE AND MX916/926/936 FIRE DEVICES INSTALLATION INSTRUCTIONS
3 4
MXBASE AND MX916/926/936 FIRE DEVICES INSTALLATION INSTRUCTIONS Cautions, warnings, and regulatory information
READ AND SAVE THESE INSTRUCTIONS
Follow the instructions in this installation manual. These
instructions must be followed to avoid damage to this product and associated equipment. Product
operation and reliability depend upon proper installation.
DO NOT INSTALL ANY PRODUCT THAT APPEARS DAMAGED
Upon unpacking your Tyco
product, inspect the contents of the carton for shipping damage. If damage is apparent,
immediately file a claim with the carrier and notify an authorized product supplier.
ELECTRICAL HAZARD
Disconnect electrical field power when making any internal
adjustments or repairs. All repairs should be performed by a representative or an
authorized agent of your local Tyco product supplier.
STATIC HAZARD
Static electricity can damage components. Handle as follows:

Ground yourself before opening or installing components.

Prior to installation, keep components wrapped in anti-static material at all times.
5
MXBASE AND MX916/926/936 FIRE DEVICES INSTALLATION INSTRUCTIONS Introduction
The Photo-Heat, Photo, and Heat detectors, use heat, and smoke detection methods to detect fires,
see Figure 1 and Figure 2. Operate these detectors with HSM3105 MX module. See Table 1 for a
description of each detector type.
Note:
Refer to document 29011152: MX916/926/936 PRODUCT APPLICATION

AND
DESIGN DOCUMENT ENG for details on detector features, placement, testing, and

maintenance.
Table 1:
Detector types
Part Number
Detector name
Detector description
88030899
MX 916 Photo-
Heat Detector
The combined optical and heat multi-sensor can detect a wide

range of fires from smoldering

to flaming.
88030900
MX926 Photo
Detector
The optical sensor is used in environments where any
potential fire is slow-burning.
88030901
MX936 Heat
Detector
The heat sensor operates in fixed temperatures and rate-
of-rise modes with a number of

approved sensitivities.
Figure 1:
Heat detector
Figure 2:
Photo, Photo-Heat, or Photo-Heat-
CO
Table 2:
Detector images description
Callout
Description
A
Status indicator, red LED
B
Unlock aperture and position where test magnet should be held.
See Table 3 for standard detector bases.
Table 3:
Detector bases
Base
Part number
Name
Detector base
description
MXBASE
88030903
4 in. Detector Base
Use when short
circuit isolation is not
required.
MXBASE AND MX916/926/936 FIRE DEVICES INSTALLATION INSTRUCTIONS
6 MXBASE installation
Install the MXBASE as shown in the wiring diagram below. As these are life-safety devices, it is
recommended to use the loop configuration to wire these devices to the HSM3105 module as
shown in Figure 3.
Figure 3:
Addressable base wiring diagram
Figure 4 and Table 4 shows the description for the MXBASE.
7
MXBASE AND MX916/926/936 FIRE DEVICES INSTALLATION INSTRUCTIONS Figure 4:
MXBASE
Table 4:
Detector images description
Callout
Description
Callout
Description
1
LED aperture plug fits here
5
Continuity Spring Loaded
Contact (4B-C Only)
2
Temporary park plunger
6
Detector locking pin, as
supplied
3
Detector locking pin fits here
7
LED aperture plug, as supplied
4
Fixing screw slot, enlarged
8
Fixing screw slot
Detector installation
To install the Photo-Heat, Photo, or Heat detectors by docking them to the MXBASE, use the
following steps:
1. Identify the raised rib alignment markers on the edges of the detector and base.
2. With the detector marker positioned approximately 15 mm or 15 degrees counter-clockwise
from the base marker, attach the detector to the base.
3. Twist the detector clockwise to align the markers and lock the detector in place.
4. Insert the detector locking pin into its hole on the side of the base, see Figure 3. Use the
locking pin to prevent the detector from rotating out of the base.
Important:
Remove the dust cover once the installation is complete.
Note:
a. To release the locking pin, depress its spring tab by using a suitable tool that
would fit inside the access hole of the decetor cover, for example a screwdriver.
b. Photo-Heat detectors will not generate an alarm on heat alone.
c. Do not use smoke detectors with detector guards unless the combination has
been evaluated and found suitable for that purpose.
MXBASE AND MX916/926/936 FIRE DEVICES INSTALLATION INSTRUCTIONS
8 Device settings
Refer to the 29011148: HSM3105 Expansion Module Installation Guide & MX alarm control

panel instruction manual for enrollment information.
Note:
Note: The detectors should be wired into the MX loop before the start of the auto-enroll
process.
To change a default device setting, select
DEVICE SETTINGS
from the MX panel menu and
configure one or more setting options in the following definition list:

LED blinking during poll:
To turn off the LED blink during polling, select
LED OFF
. The
default setting is
LED ON
. This option is available in MX916, MX926, and MX936.

Smoke Sensitivity:
Select the smoke sensing sensitivity from
Low
,
Medium
or
High
. The
default setting is
Medium
. This option is available in MX916 and MX926 only.
The following features are hardcoded and not available for installer:

Threshold Compensation
: Hardcoded option - Enabled in the MX alarm control panel. This
option is applicable to MX916 and MX926 only.

Supervision
: Hardcoded option: Enabled in the MX alarm control panel. This option is
applicable to MX916, MX926, and MX936.
9
MXBASE AND MX916/926/936 FIRE DEVICES INSTALLATION INSTRUCTIONS © 2022 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document
revision and are subject to change without notice. Additional listings may be applicable, contact your local Tyco product
supplier for the latest status. Listings and approvals under Tyco, and the product names listed in this material are marks
and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered
trademarks of the National Fire Protection Association (NFPA).


Uploaded