First Alert CAMW-WDB VX1 HD - Installation Instructions - Dated 01/2023 Rev. A



Related Products

First Alert CAMW-WDB - VX1 HD Video Doorbell by Resideo
First Alert CAMW-WDB
VX1 HD Video Doorbell by Resideo
List Price:
Our Price: $177.99

Document Transcript

Phillips #2 screwdriver
Wall Anchors (x2)
Trim Ring
(1 white, 1 gray)
Doorbell
Flat Moun�ng
Bracket
Angled Moun�ng Bracket
(Reversible)
CAMW-CHA
Chime Adapter
Wall Screws
(x3, one spare)
1/10 in x 7/16 in
(2.5 mm x 20 mm)
Terminal Screw
Spare
Drill
Home Wi-Fi Password
Tools you will need
:
When power is on, the front bu�on light
should be illuminated white to signal it
is ready for pairing.
Follow instruc�ons in app to complete
setup.
Installa�on Guide
VX1 Video Doorbell
www.resideo.com
Online Guides
TC2 Account & Password
Removing the Old Doorbell
Download and install the Total Connect
2.0 app.
The loca�on owner’s Wi-Fi password
may be needed.
1.
2.
Turn on the power at the breaker box
once device has been properly wired and
installed.
1.
3.
2.
Read these instruc�ons carefully; failure
to follow the instruc�ons can damage
the product or cause a hazardous
condi�on.
Check the product informa�on to see if
product is suitable for your applica�on.
1.
2.
Installer must be a trained, experienced
service technician.
3.
A�er comple�ng installa�on, use these
instruc�ons to verify the product
opera�on.
4.
Wire Stripper
Needle-Nose Pliers
Connec�ng to App
Choose moun�ng bracket
Before you start:
On the back of the product, use the notch to
remove the trim ring and change to
preferred color (op�onal).
Depending on the position the user
would like the camera to face, choose
the angled or flat mounting bracket.
1
2
1
2
3
4
A�ach moun�ng bracket
Insert the bundle of wires through the
back of the mounting bracket and screw
the mounting bracket to the wall.
Note: Use provided wall anchors if
necessary.
Connect exis�ng wires
Using a screwdriver, wrap the wires
around the back terminals of the
doorbell and �ghten. Gently tug on the
wires to verify they are secure.
Note: Wires can go on either terminal.
A�ach doorbell camera
A�ach the wired doorbell camera to the
moun�ng bracket. You should hear it
click into place to know it’s secure. The
trim ring should be flush with the
moun�ng bracket.
Note: Be sure to route cables back into
wall before clicking into place.
1.
2.
3.
4.
Moun�ng Bracket
Angled Moun�ng Bracket
is Reversible
Back View
Back View
Doorbell Camera Installa�on
Turn off the power at the breaker
box and check that the
system is off.
1.
2.
Remove the exis�ng doorbell from
the wall.
Note: Make sure to keep the wires
from falling back into the wall.
Release Tool
OFF
OFF
ON
OFF
ON
Breake
r box
Chime Adapter Installa�on
Locate Chime
Once chime is found, remove the chime
cover to reveal the wiring. Wiring may differ
for mechanical and digital chimes.
Connect Chime Adapter
Attach chime adapter to terminal screws
that the doorbell will be connected to.
Note: Chime adapter cables can be wired
to either terminal.
Replace Chime Cover.
Secure Chime Adapter with the adhesive
pad and replace the chime cover.
1.
2.
3.
1
2
3
ON
You may need
:
Before Installa�on.....
Included in the Box
Setup and opera�on require a Total Connect
® 2.0 account and the
Total Connect
2.0 mobile app.

If using the flat bracket, make sure the
Resideo logo is posi�oned at the top.
Use the app for step-by-step install and
setup instruc�ons.
Or con�nue steps 1 to 4 below...
If above wiring scenarios don’t match your scenario please view addi�onal
wiring scenarios in the Total Connect 2.0 app.
*Wire polarity does not have
to be considered
when wiring to doorbell camera.
*Wire polarity does not have
to be considered
when wiring to doorbell camera.
Typical Wiring Scenarios
Power using exis�ng doorbell wiring
16v 10va
(min)
18 gauge wire at 180�
(max)
18 gauge wire at 180�
(max)
16v 10va
(min)
Power directly to transformer
Video Doorbell
Transformer
Chime
Chime Adapter
Video Doorbell
Transformer
4
3
1
2
*Wire polarity does not have
to be considered
when wiring Chime Adapter.
From the Camera screen, tap the Add Camera bu�on
Select the correct device
Follow the in-app instruc�ons.
*Wire polarity does
not have to be
considered when
wiring Chime Adapter.
Drill Bits
1/16” (1.5mm)
1/4” (6mm) or
Troubleshoo�ng
Release tool
Hex Key
Paper Clip
Keep Release Tool:
Alternative tools to release the device
may be a small Hex Key or a Paper Clip.
To uninstall, adjust wiring, and access the reset bu�on, use
the provided tool in the pinhole at the bo�om of the
device.*
*If you’re s�ll experiencing issues, follow the setup
instruc�ons in the app.
If the light does not illuminate, check that the power is
on and the wires are �ght on the terminals.*
Removing the Doorbell:
The reset bu�on is located on the back of the device.*
Accessing the Reset Bu�on
Use Total Connect 2.0 app to adjust sensi�vity under the
doorbell camera se�ngs.
Adjus�ng Camera and Event Sensi�vity:
Doorbell does not Power On:
If the blue light does not illuminate use the release tool to
remove the doorbell and perform a factory reset.*
Doorbell not in Pairing Mode:
To force reboot for any reason, remove doorbell and press
the reset bu�on for 5 seconds.*
Forced Reboot:
To factory reset for any reason, remove doorbell and press
the reset bu�on for 25 seconds.*
Factory Reset:
SUP
POR
T
&
WA
RRAN
TY

For the
la
test
d
o
c
u
m
ent
a�
on
a
n
d
on
l
ine support infor
ma�
on, p
l
e
a
se
g
o to:

www
.
resi
d
eo
.c
o
m

For the
la
test w
a
rr
a
nt
y
infor
ma�
on, p
l
e
a
se
g
o to:

www
.
resi
d
eo
.c
o
m


Responsib
l
e P
a
rt
y
/ Issuer of Supp
l
ier

s De
cla
r
a�
on of
C
onfor
m
it
y
: A
d
e
mc
o In
c.
,
a
subsi
d
i
a
r
y
of Resi
d
eo
T
e
c
hno
l
o
g
ies, In
c.

2
C
orpor
a
te
C
enter Dr
.
, Me
lv
i
ll
e, N
Y
11747, Ph:
5
16
-577-2000

T
his pro
d
u
c
t
ma
nuf
ac
ture
d
b
y
Resi
d
eo
Technologies, Inc. and its affiliates





www.resideo.com

Resi
d
eo
T
e
c
hno
l
o
g
ies, In
c

2
C
orpor
a
te
C
enter Dri
v
e, Suite 1
00

P
.
O
.
Bo
x
9
0
4
0
, Me
lv
i
ll
e, N
Y
11747
© 2
0
22

Resi
d
eo
T
e
c
hno
l
o
g
ies, In
c.
A
ll
ri
g
hts reser
v
e
d.


The user shall not make any changes or modifica�ons to the equipment unless authorized by the Installa�on Instruc�ons or User's Manual.
Unauthorized changes or modifica�ons could void the user's authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protec�on against harmful interference in a residen�al installa�on. This equipment
generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc�ons, may cause harmful
interference to radio communica�ons. However, there is no guarantee that interference will not occur in a par�cular installa�on. If this
equipment does cause harmful interference to radio or television recep�on, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient or relocate the receiving antenna.
• Move the radio or television receiver away from the receiver/control.
• Increase the separa�on between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
FCC / ISED STATEMENT
This device complies with Part 15 of the FCC Rules, and ISED’s license-exempt RSSs. Opera�on is subject to the following two condi�ons:
1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may
cause undesired opera�on.
Cet appareil est conforme à la par�e 15 des règles de la FCC et exempt de licence RSS d’ISED. Son fonc�onnement est soumis aux condi�ons
suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les
interférences causant une récep�on indésirable.
RF EXPOSURE STATEMENT:

The antenna(s) used for this device must be installed to provide a separa�on distance of at least 7.8 inches (20 cm) from all persons and must
not be co-located or opera�ng in conjunc�on with any other antenna or transmi�er except in accordance with FCC and ISED mul�-transmi�er
product procedures.
MISE EN GARDE EXPOSITION AUX FRÉQUENCES RADIO:
La/les antenne(s) u�lisée(s) pour cet éme�eur doit/doivent être installée(s) à une distance de sépara�on d'au moins 20 cm (7,8 pouces) de
toute personne et ne pas être située(s) ni fonc�onner parallèlement à tout autre transme�eur ou antenne, excepté en conformité avec les
procédures de produit mul� transme�eur FCC et ISED.
FEDERAL COMMUNICATIONS COMMISSION & ISED STATEMENTS
This equipment should be installed in accordance with Na�onal Electrical Code, NFPA 70, Standard for the Installa�on of Residen�al Fire
Warning Systems, CAN/ULC-S540 and Chapter 2 of the Na�onal Fire Alarm Code, ANSI/NFPA 72 (Na�onal Fire Protec�on Associa�on,
Ba�erymarch Park, Quincy, MA 02269). Printed informa�on describing proper installa�on, opera�on, tes�ng, maintenance, evacua�on
planning, and repair service is to be provided with this equipment.
Canadian Installa�ons
For Installa�on in Canada, wiring shall be in accordance with CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical
Installa�ons ; CAN/ULC S302, Standard for the Installa�on, Inspec�on and Tes�ng of Intrusion Alarm Systems; and CAN/ULC S301, Standard for
ignal Receiving Centre Intrusion Alarm Systems and Opera�ons.
Any a�empt to reverse-engineer this device by decoding proprietary protocols, de-compiling firmware, or any similar ac�ons is strictly
prohibited.
The product should not be disposed of with other household waste. Check for the nearest authorized collec�on centers or authorized recyclers.
The correct disposal of end-of-life equipment will help prevent poten�al nega�ve consequences for the environment and human health.
Or con�nue steps 1 to 4 below...
Light On Device
Light Color
Device Status
Bu�on Light
White
Solid/Dim
Idle Night/Dark Conditions
White
Slow Pulse
Waiting for Bluetooth Pairing
White
2 X Pulse
Ring Doorbell
White
Pulsing
Firmware Update
Wait for Update to Complete
White
Brightness Increase
Person Sensed
Green
Solid
Two Way Communication
Blue
Slow Pulse
Blue
Solid
Bluetooth Pairing
Wi-Fi Pairing and Registration
No Light
Normal Operation
Installa�on
In Use
Note/Resolu�on
Red
Solid
Not Charging
Check Wiring Connections
Yellow
White
Solid
Solid
Initial Boot Up
Below Operating Charge and Charging
Allow Time for Device to Charge
Red
2 Rapid Pulse
Error/Setup Fail
Follow In-App Troubleshooting
Green
2 Rapid Pulse
Success/Confirmation
No Light
No Power
Check Wiring Connections
Yellow
Solid 5 Sec
Forced Reboot(Reset Button Pressed)
Red
Solid 5 Sec to Cycle
Factory Reset(Reset Button Held)
No Light
Idle Day/Bright Conditions
Status LED
Ligh�ng Func�ons
Light Behavior
Ligh�ng Func�ons Con�nued...
Light On Device
Light Color
Device Status
Note/Resolu�on
Light Behavior
White
Person Sensed
Colored NightVision Mode On
Solid
White
Tamper Alarm or Alarm Triggered
Reconnect Device or Disable Alarm
Rapid Pulsing
Spotlight
From the Camera screen, tap the Add Camera bu�on
Select the correct device
Follow the in-app instruc�ons.
Doorbell Specifications
Wired Doorbell
Part Number..........................................................................................................................................................
.................................CAMW-WDB
Operating Temperature...........................................................................................................................................-40 ̊F to 122 ̊F (-40 ̊C to 50 ̊C)
Operating Humidity.......................................................................................................................................................20 to 85% Non-condensing
Shipping Temperature....................................................................................................
......................
.....................-4 ̊F to 158 ̊F (-20 ̊C to 70 ̊C)
Shipping Humidity.............................................................................................................
..................
..........................10 to 95% Non-condensing
Physical Dimensions.....................................................................................................................4-3/4 x 1-3/4 x 1-1/8in (120.6 x 45 x 28.5mm)
Color.........................................................................................................................................................................................................Gray/White
Power Input..................................................................................................................................................................16-24 VAC, 10 VA minimum
Weatherproofing.......................................................................................................................
............................
..............................................IP65
Chime Adapter
Part Number
.......................................................................................................................................................................................CAMW-CHALP
Operating Temperature.............................................................................................................................................-4 ̊F to 122 ̊F (-20 ̊C to 50 ̊C)
Operating Humidity.......................................................................................................................................................20 to 85% Non-condensing
Shipping Temperature...
......................................................................................................................................
.....-4 ̊F to 158 ̊F (-20 ̊C to 70 ̊C)
Shipping Humidity........................................................................................................................................................10 t
o 95% Non-condensing
Physical Dimensions.........................................................................................................................1-5/8 x 1-1/8 x 13/32in (41 x 28 x 10.5mm)
Color.........................................................................
............................................................................................................
........................
.....White
Power Input..................................................................................................................................................................16-24 VAC, 10 VA minimum
Weatherproofing...........................
.......................................................................................................................................................................N/A
R800-27607A 1/23 Rev A


Uploaded