GSM Communicators
iGSMV/GSMV/iGSMHS
GSMCF
GSMX
GSMVLP
GSMVLP5
VISTA-GSM
G
SERVICE
Honeywell is focused on providing the best alarm communication solutions for the security industry. Alternative communication methods are critical in the marketplace due to VoIP, migration from POTS and global growth of digital networks. Honeywell’s Digital Cellular Communicators deliver secure, reliable and complementary digital communications via the GSM (Global System for Mobile) network. Our use of Dual-Path GPRS service with SMS backup provides substantial benefits to protect your investment, helping to maintain and grow your recurring revenue.
This groundbreaking communications solution offers full data reporting and uploading/downloading with most Honeywell control panels. In addition, with onboard zone inputs and optional dialer capture capability, we’re compatible with other manufacturers’ security panels as well. Honeywell communication products and control panels combine to make installations faster and easier. All signals are delivered to Honeywell’s AlarmNet® Network Control Center, which routes the information to the appropriate central station. The state-of-the-art AlarmNet Network Control Center is fully redundant and monitored 24/7. AlarmNet has the ability to route messages using AlarmNet-i and 800 PLUS services, providing true redundancy and multi-path message delivery.
FEATURES
• Full Contact ID or ADEMCO High-Speed Reporting Contact ID reporting using ECP mode with compatible Honeywell control panels or combined with optional dialer capture for non-ECP capable control panels. • 256-bit AES Encryption Advanced encryption standard used for secure communications. • Dual-Path Technology Uses GPRS (General Packet Radio Service) as primary digital cellular path and automatically switches to SMS (Short Message Service) if GPRS is unavailable. • Triple-Path Technology Provides three paths of communication using Internet, GPRS (General Packet Radio Service), and SMS (Short Message Service). Uses Internet as primary with dual GSM technology as back-up. GSM path utilizes GPRS and automatically switches to SMS if GPRS is unavailable (iGSMV only). • Upload/Download With select Honeywell control panels using GPRS. Requires Compass version 1.5.8.54a or higher. • Integration Quick and easy installation of GSM for VISTA and LYNX controls. • Dynamic Signaling with Certain Honeywell Control Panels Provides management of control panel dialer and digital cellular communicator. Programmable priority and delays determine signal path. • Diagnostic LEDs Provide signal strength and status indications. • QOS Quality of Service diagnostics via AlarmNet supply vital information including when a message was received, battery voltage, input voltage, signal strength and message path. • Commercial Fire Communicator Code compliant fire communication approved to replace one or both phone lines (standalone) in commercial fire applications. See agency listings for details. • Web-Based Programming Allows complete interactive programming from AlarmNet Direct. https://services.alarmnet.com /AlarmnetDirect • Intelligent Supervision Any message generated serves as a supervision message per optional 24 hour or 30 day intervals. This feature effectively limits required messages to be sent. • Remote Services Capability* Optional Total Connect value-added web-based or SMS system control as well as e-mail notification of system events. • Two-Way Voice Transport GSM voice channel capable to allow two-way voice session in conjunction with an audio verification system. (GSMX/iGSMV/GSMV/iGSMHS) • Line Security Approved for line security applications with 200-second supervision intervals. (iGSMHS)
*Service subscription required.
GSM Communicators
FEATURES
Features that apply to the iGSMV/GSMV and iGSMHS • Universal Control Panel Compatibility Flexible modes of operation allow ECP alarm reporting by Honeywell control panels, 4204 relay mode for Honeywell controls (that do not support ECP alarm reporting) and zone triggering for use with other control panels. (GSMV only) • Dialer Capture Ready Compatible with Dialer Capture Intelligence Device DCID (for LYNX) or DCID-EXT (other control panels). Captures Contact ID messages from the panel’s phone line and sends them to the central station via the GSM radio (not agency approved). (GSMV only) • Six Input Zones Digital processing for improved detection and false alarm protection • Tamper Protected Enclosure Built-in tamper sends a report when a tamper condition is detected and a restore when cleared. • Built-in Power Supply Onboard charging circuit design accommodates back-up battery. Includes primary power and battery supervision. • Back-Up Battery 6V 3.1Ah supplied to deliver up to 24 hours of standby operation.
SPECIFICATIONS
iGSMHS Description • Encrypted line security communication Physical • Dimensions: 8.4" x 8.0" x 1.5" • Weight: 2.4 lbs. with battery Electrical • Input Power: 9VAC, 15VA transformer, Honeywell Model No. 1332 • Backup Battery: 6V, 3.1AH, Honeywell Part No. K14139, (included) • Expected Battery Life: 5 years approx. • Current Drain: 35mA average standby, 500mA peak transmit • Fault Relay Output: Open collector, 12VDC, .25W max. • Input Trigger Levels: (V+) 6V – 13V; (V-) 0V – 1V RF • Transceiver Type: Tri-Band GSM/ GPRS Class 10 • Modulation: GMSK • Antenna: Internal GSM quad-band 1.3dBi gain Environmental • Operating temperature: -20º to 55º C • Storage temperature: -40º to 70º C • Humidity: 0 to 95% relative humidity, non-condensing • Altitude: to 10,000 ft. operating; to 40,000 ft. storage
GSMVLP (LYNX Plus only)/GSMVLP5 (LYNX Touch only) Description • Voice capable, quad band digital cellular communicator for use with L3000/L5000 series controls • Uses an integrated quad band antenna that eliminates the coaxial cable connections for a high reliability RF interface Physical • Dimensions: 5.5" x 2.5" (GSMVLP) 4.75" x 2.5" (GSMVLP5)
GSMX
Electrical • Powered and battery backed directly from L3000 Control • Input Voltage: 10.5VDC nominal (GSMVLP) 5VDC nominal (GSMVLP5) • Quiescent Current: 40mA (GSMVLP) 15mA (GSMVLP5) • Average Current During Transmit: 200mA (GSMVLP) 300mA (GSMVLP5)
Antenna • Quad Band: GSM 850, 900, 1800 & 1900 • VSWR: 3:1 • Peak Gain: 3 dBi • Impedance: 50 ohms • Polarization: linear
Description • Quad band digital cellular communicator for use with ECP capable Honeywell control panels • Supports cabinet mount or may
be remotely located
Physical • Dimensions: 4" x 7" x 1.75" 2
Electrical • Input Voltage: 12VDC (powered via the ECP bus) • Standby Current: 30mA • Transmit Current: 200mA (Average) • Transceiver Type: GSM/GPRS with internal antenna
• Dialer Capture Ready: Compatible with Dialer Capture Intelligence Device DCID (for LYNX) or DCID-EXT (other control panels). Captures Contact ID messages from the panel’s phone line and sends them to the central station via the GSM radio (not agency approved).
GSM Communicators
SPECIFICATIONS
VISTA-GSM
Physical • Dimensions: 2.2" x 4.0" Electrical • Input Voltage: 4.1V • Peak Current During Transmit: 1.6A • Quiescent Current: 20mA
VISTA-GSM Antenna • Type: Dual band, dipole • VSWR: <2:1 • Bands: 824-896 MHz, 1850-1990 MHz • Impedance: 50 ohms
• • • •
Polarization: Vertical Dimensions: 161mm x 26mm Gain (Peak): 0-4 dBi Connector Type: SMA male
Communications Device Agency Listings (U.S.)
Communication Devices Description Testing Agency Commercial Standards
UL1610 UL365 Police Central UL1635 Connected Station Digital Alarm Burglar Alarm UL609 Local Burglar Alarm Communications Commercial Burglar Alarm Commercial Commercial Burglar Burglar Burglar Systems
*Standalone listing does not require a separate listed DACT. **Primary/backup listing requires use of a listed DACT.
Residential Standards
Encrypted Line Security (Grade AA) Commercial Burglar
UL864 Standalone*
UL864 Primary/ Backup**
California State Fire Marshall (CSFM)
UL1023 UL985 Household Household Burglar Alarm Fire
AlarmNet-G
GSMCF GSMV iGSMHS GSMVLP GSMVLP5 GSMX iGSMCF iGSMV
Commercial Fire Kit (GSMV included) GSM Cellular Communicator Line Security Communicator GSM Communication Module for LYNX Plus GSM Communication Module for LYNX Touch GSM Cellular Communicator Internet/GSM Cellular Communicator Snap-in GSM Communication Module for VISTA-21iP Control UL UL/ETL
3 3
3
(ETL Only)
3 3
3
(UL Only)
3
(ETL Only)
3
3 3 3 3 3
3 3 3 3 3
3 3 3 3
3
ETL
ETL
ETL
ETL
3 3
3 3
3 3 3
3
3
3 3 3 3
VISTA-GSM
ETL
Communications Device Agency Listings (Canada)
Communication Devices Description Testing Agency
ULC-S303 Local Burglar Alarm ULC-S304 Central and Monitoring Station Burglar Alarm
Canadian Standards
ULC-S545 Residential Fire Warning System ULC/ORD-C1023 Household Burglar
ULC-S559
AlarmNet-G
GSMCN GSMVCN GSMLCN GSMVLPCN GSMVLP5CN GSMXCN iGSMCN iGSMVCN GSM Cellular Communicator Snap-in GSM Communication Module for LYNX Control GSM Communicator Module for LYNX Plus GSM Communicator Module for LYNX Touch GSM Cellular Communicator Internet/GSM Cellular Communicator Snap-in GSM Communication Module for VISTA-21iP Control cUL/ULC cETL ETL ETL ETL ETL
3 3
3 3
3 3 3 3 3
3 3 3 3 3 3 3
3
cUL/ULC
3 3
3 3
3 3
3
VISTA-GSMCN
ETL
3
GSM Communicators
ACCESSORIES*
7720P Programmer K14139 Battery 1361 Transformer Two-Way Voice Audio Cables DCID Dialer Capture Intelligence Device (For Non-ECP LYNX controls) DCID-EXT Dialer Capture Intelligence Device (For Non-ECP capable control panels)
*Consult the installation instructions for accessory use and compatibility.
ORDERING
U.S. GSMCF GSM-EAA iGSMHS GSMV GSMV-AUDIO GSMV-KT GSMVLP GSMVLP5 GSMVLP-AUDIO GSMVLP-KT GSMX GSMX-AUDIO iGSMCF iGSMV-KT iGSMV VISTA-GSM Canada GSMVCN GSMVLPCN GSMVLP5CN GSMXCN iGSMVCN VISTA-GSMCN
Commercial Fire Communication Kit includes: GSMV, Commercial Red Cabinet, 3 dB Antenna Kit
External Antenna Adapter (GSMX and GSMVLP only) Line Security Communicator Digital Cellular Communicator with Two-Way Voice Transport Capability Two-Way Voice Audio Cable GSMV with Audio Cable (GSMV-Audio) for Two-Way Voice Applications Internal GSM Module for LYNX Plus with Two-Way Voice Transport Capability Internal GSM Module for LYNX Touch with Two-Way Voice Transport Capability Audio Cable Required for LYNX Plus/GSMVLP Two-Way Voice Applications GSMVLP with Audio Cable (GSMVLP-AUDIO) for Two-Way Voice Applications Digital Cellular Communicator for VISTA Control Panels Two-Way Voice Audio Cable Commercial Fire Communication Kit includes: GSMV, Commercial Red Cabinet, 3db Antenna Kit iGSMV with Audio Cable (GSMV-Audio) for Two-Way Voice Applications Internet and GSM Communicator with Two-Way Voice Transport Capability Plug-in GSM Module for VISTA-21iP
Digital Cellular Communicator with Two-Way Voice Transport Capability (Canada) Internal GSM Module for LYNX Plus with Two-Way Voice Transport Capability (Canada) Internal GSM Module for LYNX Touch with Two-Way Voice Transport Capability (Canada) Digital Cellular Communicator for VISTA Control Panels (Canada) Internet and GSM Communicator with Two-Way Voice Transport Capability (Canada) Plug-in GSM Module for VISTA-21iP (Canada)
Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com
L/GSMXD/D January 2012 © 2012 Honeywell International Inc.