Honeywell AlarmNet Message Definitions



Related Products

Honeywell 7626-25HC - AlarmNet 25' RF Antenna Coax Cable
Honeywell 7626-25HC
AlarmNet 25' RF Antenna Coax Cable
List Price: $172.00
Our Price: $121.99
Honeywell 7626-50HC - AlarmNet 50’ RF Antenna Coax Cable
Honeywell 7626-50HC
AlarmNet 50’ RF Antenna Coax Cable
List Price: $264.00
Our Price: $185.99
Honeywell 7626-5 - AlarmNet 5' RF Antenna Coax Cable
Honeywell 7626-5
AlarmNet 5' RF Antenna Coax Cable
List Price: $110.00
Our Price: $78.99
Honeywell 7670F - AlarmNet GSM-ANT3DB Antenna Mounting Bracket
Honeywell 7670F
AlarmNet GSM-ANT3DB Antenna Mounting Bracket
Honeywell 7847i - AlarmNet Internet Alarm Monitoring Communicator
Honeywell 7847i
AlarmNet Internet Alarm Monitoring Communicator
Honeywell 7847i-L - AlarmNet L3000 LYNX Plus Internet Alarm Monitoring Communicator
Honeywell 7847i-L
AlarmNet LYNX Plus Internet Alarm Monitoring Communicator
Honeywell CELL3DB25KT - AlarmNet 25’ Antenna Kit
Honeywell CELL3DB25KT
AlarmNet 25’ Antenna Kit
List Price: $398.00
Our Price: $278.99
Honeywell CELL3DB50KT - AlarmNet 50’ Antenna Kit
Honeywell CELL3DB50KT
AlarmNet 50’ Antenna Kit
List Price: $490.00
Our Price: $342.99
Honeywell GSM3DBKT - AlarmNet Antenna Kit
Honeywell GSM3DBKT
AlarmNet Antenna Kit
List Price: $224.00
Our Price: $157.99
Honeywell GSM-ANT3DB - AlarmNet Remote Weatherproof GSM Antenna
Honeywell CELL-ANT3DB
AlarmNet Remote Weatherproof Cellular Antenna
List Price: $168.00
Our Price: $118.99
Honeywell GSM-ANT - AlarmNet Indoor 10’ Remote GSM Antenna
Honeywell CELL-ANT
AlarmNet Indoor 10’ Remote GSM Antenna
Honeywell GSM-EAA - AlarmNet External Antenna Accessory
Honeywell GSM-EAA
AlarmNet External Antenna Accessory
Honeywell GSMV - AlarmNet Cellular Alarm Monitoring Communicator
Honeywell GSMV
AlarmNet Cellular Alarm Monitoring Communicator
Honeywell GSMVLP5-4G - AlarmNet LYNX Touch L5100 Total Connect Cellular Alarm Monitoring Communicator
Honeywell GSMVLP5-4G
AlarmNet LYNX Touch Cellular Alarm Monitoring Communicator
Honeywell GSMVLP5 - AlarmNet LYNX Touch Cellular Alarm Monitoring Communicator
Honeywell GSMVLP5
AlarmNet LYNX Touch Cellular Alarm Monitoring Communicator
Honeywell GSMVLP - AlarmNet LYNX Plus Cellular Alarm Monitoring Communicator
Honeywell GSMVLP
AlarmNet LYNX Plus Cellular Alarm Monitoring Communicator
Honeywell GSMV-TC2 - AlarmNet Total Connect 2.0 Upgrade Kit
Honeywell GSMV-TC2
AlarmNet Total Connect 2.0 Upgrade Kit
Honeywell GSMX - AlarmNet Cellular Alarm Monitoring Communicator
Honeywell GSMX
AlarmNet Cellular Alarm Monitoring Communicator
Honeywell GSMX-TC2 - AlarmNet Total Connect 2.0 Upgrade Kit
Honeywell GSMX-TC2
AlarmNet Total Connect 2.0 Upgrade Kit
Honeywell iGSMHS - AlarmNet High Security Dual Path Alarm Monitoring Communicator
Honeywell iGSMHS
AlarmNet High Security Dual Path Alarm Monitoring Communicator
Honeywell iGSMV - AlarmNet Dual Path Alarm Monitoring Communicator
Honeywell iGSMV
AlarmNet Dual Path Alarm Monitoring Communicator
Honeywell iGSMV-TC2 - AlarmNet Total Connect 2.0 Upgrade Kit
Honeywell iGSMV-TC2
AlarmNet Total Connect 2.0 Upgrade Kit
Honeywell ILP5 - Front AlarmNet LYNX Touch Internet Alarm Monitoring Communicator
Honeywell ILP5
AlarmNet LYNX Touch Internet Alarm Monitoring Communicator
List Price: $194.00
Our Price: $136.99
Honeywell K14139 - AlarmNet Alarm Communicator Battery Backup
Honeywell K14139
AlarmNet Alarm Communicator Battery Backup
List Price: $22.00
Our Price: $16.99
Honeywell K14207LF - AlarmNet MMCX to SMA Adapter Cable
Honeywell K14207LF
AlarmNet MMCX to SMA Adapter Cable
Honeywell L5100-WIFI - AlarmNet LYNX Touch L5100 Security System WiFi Alarm Monitoring Communicator
Honeywell L5100-WIFI
AlarmNet LYNX Touch WiFi Alarm Monitoring Communicator
List Price: $128.00
Our Price: $90.99
Honeywell VISTA-GSM - AlarmNet VISTA-21iP Cellular Alarm Monitoring Communicator
Honeywell VISTA-GSM
AlarmNet VISTA-21iP Cellular Alarm Monitoring Communicator
Honeywell WA7626-CA - AlarmNet SMA to N Adapter Cable
Honeywell WA7626-CA
AlarmNet SMA to N Adapter Cable
List Price: $54.00
Our Price: $38.99

Related Categories


Document Transcript

AlarmNet Message Definitions

®

Definitions of AlarmNet Network and Subscriber Messages
[02/07/2011]

Important notes:
General  The information contained in this document concerns AlarmNet transmissions only, and assumes that the user has knowledge of central station receivers, formats, procedures, and programming. It is designed to be a supplementary reference to existing instructions. Be sure to read all documentation that comes with any and all equipment used to report and monitor alarms.  It is up to the Central Station to determine how to respond to the conditions reported by devices as described in this manual. It is also important that all the messages pertaining to your subscribers and Central Station configuration are entered into your Central Station’s automation system so that operators can respond to them properly. There may be additional charges for sending messages, or a limit to the number of messages included in the monthly subscription charges for any subscriber. Check with your Central Station, or with AlarmNet for further information. It is important to read the definitions contained in the Glossary to determine meanings and causes of certain expressions for conditions used in this manual. AlarmNet may make additions and changes to this document without notice. Please contact AlarmNet to confirm that you have the latest edition. If you have any questions, or are unsure of any information presented in this document, please contact AlarmNet at (800) 222-6525.

 

Equipment Specific  For the 7620 and 7620 ULF radios (manufactured between 1986 and 1992), alarms, alarm restores, and previously reported alarms will also be sent with a low-battery message in the ninth channel.  For the 7720, 7720ULF, and 7920SE radios, (manufactured from 1991 onward) alarm and trouble messages are mutually exclusive, and will be reported separately, even if they were to occur together. Additionally, with these radios, the communication of previously reported alarm and trouble messages will also be confined to the same type of report. In other words, alarm reports will convey no information about prior trouble conditions, and trouble reports will convey no information about prior alarms. Check installation instructions to ensure that the radio is programmed, wired, and configured to properly send alarm signals. Please refer to the installation instructions of your equipment to determine specific causes of non-alarm messages such as trouble, supervisory or system messages Although a radio is programmed with a Network (City) ID, and a Central Station ID, these numbers are neither displayed on the receiver, nor sent to its printer or computer, but are used only to tell the network which receiver the messages for a particular subscribers should be sent to.

  

AlarmNet Message Definitions

AlarmNet®

Page 1

What is the AlarmNet Messages Document?
AlarmNet transmissions may be sent in either the Ademco High Speed format, or in Ademco Contact ID format. The AlarmNet Messages Document describes the structure and formatting of these transmissions. It also specifically describes and defines the various AlarmNet High-Speed messages that are unique to AlarmNet so that they may be responded to properly when received at the Central Station.

Who should use this Document?
Central Station Dept. / Automation System Programmers: The messages described in this document need to be programmed or otherwise defined in the Central Station’s automation system so that operators can properly respond to conditions at the subscriber premises, at the Central Station, or relating to the AlarmNet network overall.

How to use this Document:
This document has two basic sections. 1- The first section describes the format of the Ademco Contact ID and High-Speed messages, and also defines interpretation of specific High-Speed messages that are unique to AlarmNet. These High-Speed definitions are categorized by the value of the Status channel, and sub-categorized by a ‘Key Indicator’, which is a specific character embedded within the message that uniquely identifies that message. When programmed for ECP mode (the mode which will send Contact ID format), the AlarmNet subscriber device essentially sends whatever the compatible Ademco control tells it to send. Therefore, Contact ID transmissions are governed by the alarm control and not the device. As such, interpretation of the Contact ID format is not defined in this document, but rather in the manual for the alarm control. 2- The second section is a Glossary that further defines the descriptions and jargon used in the definitions of the specific High-Speed messages, and other areas of the manual. While the first section will define what a specific High-Speed message means, the Glossary will describe the conditions that may cause this message to be sent, and how it may be restored.

AlarmNet Message Definitions

AlarmNet®

Page 2

Table of Contents: AlarmNet Messages:
Important notes: .................................................................................................................................................. 1 What is the AlarmNet Messages Document? ..................................................................................................... 2 Who should use this Document?......................................................................................................................... 2 How to use this Document:................................................................................................................................. 2 Table of Contents: .............................................................................................................................................. 3 Section # 1 - Message Formats............................................................................................................... 4 Ademco Contact ID format:................................................................................................................................ 5 How Contact ID is sent from the subscriber device ....................................................................................... 5 How Contact ID is displayed on the 685 receiver .......................................................................................... 5 How Contact ID is displayed on the printer.................................................................................................... 6 Reading a Contact ID message ....................................................................................................................... 6 Contact ID Message interpretation: ................................................................................................................ 7 Ademco High-Speed format: .............................................................................................................................. 8 How High Speed is sent from the subscriber device: ..................................................................................... 8 How High Speed is displayed on the 685 receiver ......................................................................................... 9 How High Speed is displayed on the printer .................................................................................................. 9 Reading a High Speed message ...................................................................................................................... 9 High-Speed Message interpretation:............................................................................................................. 11 Status Channel = 0 (Diagnostic Message) ................................................................................................ 11 Status Channel = 1 (Notification Message) .............................................................................................. 14 Status Channel = 5 (Subscriber Trouble / Special Report) ....................................................................... 15 Status Channel = 6 (Status Message)........................................................................................................ 16 Status Channel = 7 (Alarm condition) ...................................................................................................... 18 Status Channel = 8 (Alarm with low battery (older 7620 radio only))..................................................... 20 Status Channel = 9 (Installer generated test message).............................................................................. 21 Section # 2 - Glossary ............................................................................................................................... 22

AlarmNet Message Definitions

AlarmNet®

Page 3

Section # 1 - Message Formats
There are two categories of messages that are sent by AlarmNet: 1 – Subscriber Messages – indicate alarm or trouble conditions at the subscriber premises, or identify issues with the subscriber device that may need attention. Subscriber messages can be sent in one of two formats:  Contact ID OR  Ademco High Speed

2 – Network Messages – indicate specific conditions with the AlarmNet network, central station transceivers, and or subscribers. Network messages are sent in:  Ademco High-Speed ONLY  May include messages for subscriber # 0000 or account numbers assigned to your Central Station receiver(s). AlarmNet Network Messages are sent in High-Speed format only, so central station receivers that receive AlarmNet transmissions must be able to accept Ademco High-speed Format. If AlarmNet subscribers are programmed to send Ademco Contact ID, the receiver should be able to receive that format as well. Each of these two formats are discussed separately and in further detail on the following pages:

AlarmNet Message Definitions

AlarmNet®

Page 4

Ademco Contact ID format:
 Consists of o A four digit subscriber ID o A ‘qualifier’ that indicates whether the message is an event or a restoral o An event code indicating the type of AlarmNet o An optional partition number o The exact zone or user number that initiated the report Is transmitted in DTMF (touch-tone) when sent via (800) Plus Uses single-round w/ checksum when reported via AlarmNet (800) Plus service Can NOT be sent via AlarmNet-A Remote 800 Service where the AlarmNet-A tower dials the message directly as the AlarmNet-A nodes can not send HEX digits via their dialers. These messages WILL work using the AlarmNet (800) Plus service.

  

How Contact ID is sent from the subscriber device

How Contact ID is displayed on the 685 receiver

AlarmNet Message Definitions

AlarmNet®

Page 5

How Contact ID is displayed on the printer

Reading a Contact ID message
1 – The “Event Qualifier” is a single character that can be:  “E” for an Event OR  “R” for a Restore 2 – The “Event Code” is three digits and represents a specific type condition. Refer to the Ademco Contact ID documentation in the instructions of your alarm control panel for specific codes. Below are some examples of conditions that can be sent: • Medical – Pendant transmitter, Fail to check in • Fire – Water flow, Pull station, Heat sensor • Panic – Duress, Silent, Audible • Burglary – Interior, Perimeter, 24 Hour • Supervisory, Trouble, Open/Close, Tamper 3 – The “Partition” or “Group” is a two-digit number indicates which partition is reporting the alarm. For nonpartitioned panels, the value is always “00”. 4 – The last three digits are the “Zone or User” number, which specifies the exact zone number that caused the event, or the user number transmitting the signal (typically an Open/Close report).

AlarmNet Message Definitions

AlarmNet®

Page 6

Contact ID Message interpretation:
When programmed for ECP mode (the mode which will send Contact ID format), the AlarmNet subscriber device essentially sends whatever the compatible Ademco control tells it to send. Therefore, Contact ID transmissions are governed by the alarm control and not the device. As such, interpretation of the Contact ID format is not defined in this document, but rather in the manual for the alarm control. Please refer to the manual provided with your compatible Ademco alarm control for this information.

AlarmNet Message Definitions

AlarmNet®

Page 7

Ademco High-Speed format:
 Consists of o A four digit subscriber ID o Eight channels of information indicating zones or other information in each message o A ninth status digit indicating the type of report Transmitted in DTMF (touch-tone) when sent via (800) Plus Uses single-round w/ checksum when reported via AlarmNet (800) Plus service

 

How High Speed is sent from the subscriber device:
“Double Round” sends two identical messages for verification:

“Single Round with Checksum” sends one message, using a checksum digit for verification:

AlarmNet Message Definitions

AlarmNet®

Page 8

How High Speed is displayed on the 685 receiver

How High Speed is displayed on the printer

Reading a High Speed message
 To decode a High Speed message, first refer to the Status Channel (9th channel). This will indicate what type of message is being sent. Next, look at the first eight channels to determine the exact content of the message, or what zones are being affected. Also, if the subscriber ID is a “0000” or any account number assigned to your Central Station receiver(s), the message should have special attention. You should be aware of the account numbers for your Central Station receivers, and be alert to any messages referring to those C/S account numbers.

AlarmNet Message Definitions

AlarmNet®

Page 9

The status channel (9th channel) identifies the type of message 0 = Diagnostic Messages 1 = Notification Message 2 = Not applicable to device accounts 3 = Not applicable to device accounts 4 = Not applicable to device accounts 5 = Subscriber Trouble / Special Reports 6 = Status Message 7 = Alarm condition 8 = Alarm with low battery (old 7620 radio) 9 = Installer or AlarmNet network generated test message. The previous eight channels indicate the message details:  For System messages, each channel represents a unique condition  For Subscriber Zone Conditions, each channel represents a zone

AlarmNet Message Definitions

AlarmNet®

Page 10

High-Speed Message interpretation:
On the following pages are explanations of AlarmNet-specific High-Speed messages that may be sent by an AlarmNet subscriber device, by the AlarmNet network, or by the Ademco receiver. These messages are categorized according to the value in the status channel, which determines the type of report. Some types of messages (generally those with status channel “0”) do not use the first eight channels to indicate zones. These messages are identified by a unique character in a particular channel that is called a “Key Indicator”. Notes:  All messages apply to all types of subscriber devices (AlarmNet–A, –M, -I or -G), except where noted.    The “Key Indicator” is a unique character in a specific channel position that can be used to identify a specific type of message. The letters ‘cccc’ are used to represent the customer subscriber ID number (device account number). The letters ‘rrrr’ are used to represent any account number assigned to your Central Station receiver(s), usually a subscriber ID of “0000” or “0001”. AlarmNet-A receivers are always “0000”. These messages should have special attention. You should be aware of the account numbers for your Central Station receivers, and be alert to any messages referring to those C/S account numbers. Other lowercase letters are used to represent different codes or characters that have various meanings in certain messages, and are defined in the ‘Definitions’ column of each table. It is important to read the definitions contained in the Glossary to determine meanings and causes of certain expressions for conditions used in this manual.

 

Status Channel = 0 (Diagnostic Message)
Message Definition: Applies to: Key Indicator: “A” in 3rd channel cccc ngA0 s0fm 0 A-type diagnostic (Internet, 800 Plus, or RF delivery) n = number of the node reporting (1-9, A-F) g = node group number (0 or 1) A = A-type diagnostic s = signal strength (0-9, or A) f = frequency (always “0”, not used) m = modulation level (always “0”, not used) Key Indicator: “D” in 3rd channel cccc 00D0 010B 0 Generated when any AlarmNet-C series radio is substituted with a 7845GSM or 7845i-GSM product using the same subscriber account number. cccc 00D0 010C 0 Authorized device substitution or re-registration. cccc 00D0 010E 0 Unauthorized substitution attempt cccc 00D0 020E 0 Service termination alarm cccc 00D0 020C 0 Code download cccc 00D0 0104 0 Reset Command sent cccc 00D0 0103 0 Comm inquiry sent cccc 00D0 0106 0 Test command sent
AlarmNet Message Definitions AlarmNet®

A

G, I

G, I, M G, I, M G, I, M M A A A
Page 11

cccc ngD0 rrrr 0

Subscriber Report (Internet, 800 Plus, or RF delivery) n = number of the node reporting (1-9, A-F) g = node group number (0 or 1) D = indicates subscriber trouble rrrr = reason code: 0001 = Low signal strength 0002 = Frequency Error 0003 = Modulation Error 0004 = keyed-on subscriber 0005 = Repeating alarm suppressed 0006 = Redundant supervision (single node) warning 0007 = Multiple nodes down 000A= Redundant supervision (single node) restore 000B = Multiple nodes down restore 000C = 2-Way radio internal tamper * Messages for account # “0000” refer to the Central Station.

A

0000 ngD0 00DB 0

Database update in progress n = number of the node reporting (1-9, A-F) g = node group number (0 or 1) D0 = indicates this node is being updated 00DB = indicates a database update

A

Key Indicator: “E” in 3rd channel 0000 00E0 cccc 0 Illegal subscriber message 0000 ngE0 cccc 0 Illegal Subscriber (Internet, 800 Plus, or RF delivery) n = number of the node reporting (1-9, A-F) g = node group number (0 or 1) E = indicates subscriber trouble warning cccc = customer subscriber number reporting

A A

Key Indicator: “F” in 3rd channel cccc ngF0 srr4t 0 F-Type diagnostic (Pass/Fail) (Internet, 800 Plus, or RF A delivery) n = number of the node reporting (1-9, A-F) g = node group number (0 or 1) F = F-type diagnostic 0 = unused, always “0” s = signal strength (0-9, or A) rr = repeat count (00–60) t = Pass/Fail result:  A = Acceptable  F = Failure

AlarmNet Message Definitions

AlarmNet®

Page 12

Key Indicator: “1” in 4th channel cccc nng1 ssfm 0 A-type diagnostic (Node dialer delivery) nn = number of the node reporting (01 to 15) g = node group number (0 or 1) 1 = indicates an A-type diagnostic ss = signal strength (0-10) f = frequency (always “0,” not used) m = modulation level (always “0,” not used) Key Indicator: “4” in 4th channel cccc nng4 rrrr 0 Subscriber Command Failure (Node Dialer delivery) nn = number of the node reporting (01 to 15) g = node group number (0 or 1) 4 = Subscriber trouble message rrrr = reason code: 0001 = Low signal strength 0002 = Frequency Error 0003 = Modulation Error 0004 = keyed-on subscriber 0005 = Repeating alarm suppressed 0006 = Redundant supervision (single node) warning 0007 = Multiple nodes down 0010= Redundant supervision (single node) restore 0011 = Multiple nodes down restore 0012 = 2-Way radio internal tamper * Messages for account # “0000” refer to the Central Station. Key Indicator: “5” in 4th channel 0000 nng5 cccc 0 Illegal Subscriber (Node dialer delivery) nn = number of the node reporting (1-15) g = node group number (0 or 1) 5 = Always “5”. Indicates subscriber trouble warning. cccc = customer subscriber number reporting Key Indicator: “6” in 4th channel cccc nng6 ss00 0 F-type diagnostic (Node dialer delivery) nn = number of the node reporting (01 to 15) g = node group number (0 or 1) 6 = Always “6”. Indicates an F-type diagnostic ss = signal strength (0-10)

A

A

A

A

AlarmNet Message Definitions

AlarmNet®

Page 13

Status Channel = 1 (Notification Message)
Message cccc 5155 5555 1 cccc 5355 5555 1 cccc 5555 5551 1 Definition: Battery Charger Failure on 7845GSM and 7845i-GSM products. Battery Charger Restoral on 7845GSM and 7845i-GSM products. Applies to: G G

Secondary Communications Path Failure – 7845i-GSM product G (Device Failure-GPRS when in Zone mode) Secondary Communications Path Restoral – 7845i-GSM product G (Device Failure-GPRS when in Zone mode) Network Alert Message – A, G, I, M Tells the C/S to refer to their e-mail or fax machine for further information and instructions from AlarmNet.

cccc 5555 5553 1

0000 5555 5555 1

AlarmNet Message Definitions

AlarmNet®

Page 14

Status Channel = 5 (Subscriber Trouble / Special Report)
Message Definition: Applies to:

Key Indicator: For Central Station receiver accounts only. rrrr 5555 5515 5 Master Host Alarm A, I, M This message is generated internally by the 685. It indicates a failure to connect to the network. This may be caused by:  Antenna failure  Receiver failure  Substantial interference  Network outage This message means that the AlarmNet-A central station receiver is not being supervised, and needs immediate attention! rrrr 5555 5535 5 rrrr 5555 1555 5 Master Host Alarm Restore A, I, M

Master Host Alarm Reminder: Notifies the Central Station that I, M the redundant receiver has lost connection to the 685 Check receiver printer A, I, M Tells the C/S to refer to their printer for messages that might not be reported through the automation system. Primary Communications Path Failure (When communicator is in Zone mode). Primary Communications Path Restore (When communicator is in Zone mode). G, I

rrrr 5155 5555 5

rrrr 5555 5551 5

rrrr 5555 5553 5

G, I

Note: For subscriber reporting, each channel of these message types corresponds to a particular type of event. Because there are eight channels, it is possible for multiple events to be reported in multiple channels in only one message. (Example: The message “cccc 1555 5355 5” indicates a fault on zone 1 and a restore on zone 6) cccc zzzz zzzz 5 Fire zone supervisory fault z = zone number corresponding to the channel position (1 – 8) 1 = New zone fault 3 = Zone restore 5 = Normal zone condition 6 = Previously report zone fault Loss of ECP Supervision (‘Master Host’ type message for an individual subscriber) Applies to GSM products when used in 4204 mode only
AlarmNet®

7720ULF or 7920SE

cccc 5555 5515 5

G, I

AlarmNet Message Definitions

Page 15

Status Channel = 6 (Status Message)
Note: Each channel of these message types corresponds to a particular type of event. Because there are eight channels, it is possible for multiple events to be reported in multiple channels in only one message. (Example: The message “cccc 1555 5155 6” would indicate an AC loss and a Telco Fault). Message Definition: Applies to:

Key Indicator: rrrr = central station receiver accounts only. 0000 = AlarmNet-A receiver account. rrrr 5555 1555 6 Central Station Communications Failure A, I, M Note: this may be received via the (800) Backup capability for an AlarmNet-A receiver, or by the secondary C/S receiver for an AlarmNet-M or AlarmNet-I C/S rrrr 5555 3555 6 0000 5515 5555 6 Central Station Communications Failure Restore. Central Station device Poll timeout. This message means that the AlarmNet-A central station radio receiver is not being supervised, and needs immediate attention! Central Station device Poll timeout restore Central Station Power-on reset A, I, M A

0000 5535 5555 6 0000 5551 5555 6

A A, I, M

Key Indicator: cccc = subscriber accounts cccc 1555 5555 6 Input Power loss (primary power source) cccc 3555 5555 6 cccc 6555 5555 6 cccc 5155 5555 6 Input Power loss restore (primary power source) Input Power loss previously reported (primary power source)

A, G, I, M A, G, I, M A, G, I, M

Low Battery. A, G, I, M Note: This message indicates that the AlarmNet communicator’s battery is low, not that of the alarm control panel.

AlarmNet Message Definitions

AlarmNet®

Page 16

cccc 5355 5555 6 cccc 5655 5555 6 cccc 5515 5555 6

Low Battery restore Low Battery previously reported

A, G, I, M A, G, I, M

Two-Way radio Poll timeout (see glossary for important A details). Power-on reset. (see glossary for important details). Communications Failure Communications Failure restore Communications Failure previously reported Communications Failure Reminders Telco line fault Telco line fault restore Telco line fault previously reported System Supervisory fault (ground or bell fault) System Supervisory fault restore (ground or bell fault) System Supervisory fault previously reported (ground or bell) Walk test Walk test exit Exiting battery charge mode A, G, I, M A, G, I, M A, G, I, M A, G, I, M A A, G, I, M A, G, I, M A, G, I, M 7720ULF 7720ULF 7720ULF 7720ULF 7720ULF 7720V2

cccc 5551 5555 6 cccc 5555 1555 6 cccc 5555 3555 6 cccc 5555 6555 6 cccc 5555 1555 6 cccc 5555 5155 6 cccc 5555 5355 6 cccc 5555 5655 6 cccc 5555 5515 6 cccc 5555 5535 6 cccc 5555 5565 6 cccc 5555 5551 6 cccc 5555 5553 6 cccc 5353 5555 6

AlarmNet Message Definitions

AlarmNet®

Page 17

Status Channel = 7 (Alarm condition)
Notes: Each channel of these message types corresponds to a particular type of event. Because there are eight channels, it is possible for multiple events to be reported in multiple channels in only one message. (Example: “cccc 1553 5555 7” indicates an alarm on zone 1 and a restore on zone 4) Message cccc zzzz zzzz 7 Definition: Zone fault z = zone number corresponding to the channel position (1 – 8) 1 = New zone fault 2 = Opening (system disarmed) 3 = Zone restore 4 = Closing (system armed) 5 = Normal zone condition 6 = Previously reported zone fault Example: 1234 5515 5555 7 • Indicates a new alarm on zone 3 1234 5165 5555 7 • Indicates a new alarm on zone 2, with a previously reported, un-restored condition still on zone 3. (i.e. The ‘6’ in the third channel indicates that previously, zone 3 had gone into alarm, was reported in a message with a 1 in channel three, and remains violated) 1234 5335 5555 7 • Indicates a restore on zones 2 and 3. I.e. the conditions that caused the alarm on zones 2 and 3 have returned to a normal state. Note: Sending restoral signals is optional in programming. Applies to: A, G, I, M

Example: 1234 5525 5555 7 • Indicates an Opening message 1234 5545 5555 7 • Indicates a Closing message Open/Close signals are typically sent via the Control Panel’s Dialer, however they may be optionally programmed to be sent via the device as well. Open/Close messages will be sent on a particular channel when the device is programmed properly and wired to the alarm control so that a signal is sent to the device when the alarm is Disarmed (Opening) or Armed (Closing).

Note regarding the 7620ULF: Due to the fact that the 7620ULF is not a fire alarm control, supervisory faults from the fire control panel may be used to trigger one or more of the eight channels on the
AlarmNet Message Definitions AlarmNet® Page 18

7620ULF, and thus will be reported as alarms. The Central Station should be aware of which of the eight channels are actually reporting supervisory conditions so alarm reports for these channels can be responded to correctly. cccc 5555 5551 7 AC Loss 7620ULF

cccc 5555 5553 7

AC Loss Restore

7620ULF

rrrr 5155 5555 7

If this C/S unit has software version 2.083 or above, this message 7810iR-ENT indicates that ‘manual mode’ is on. Prior versions do not send this message. If this C/S unit has software version 2.083 or above, this message 7810iR-ENT indicates that ‘auto mode’ is on. Prior versions do not send this message.

rrrr 5551 5555 7

AlarmNet Message Definitions

AlarmNet®

Page 19

Status Channel = 8 (Alarm with low battery (older 7620 radio only))
Notes: Each channel of these message types corresponds to a particular type of event. Because there are eight channels, it is possible for multiple events to be reported in multiple channels in only one message. (Example: “cccc 1553 5155 8” indicates an alarm on zone 1 and a restore on zone 4 and a low battery) Message cccc 5555 5555 8 Definition: Low Battery message Applies to: 7620 or 7620ULF 7620 or 7620ULF

cccc zzzz zzzz 8

Low battery with reported alarms Alarm messages are identical to those reported when the status channel is a “7”. The “8” only indicates that a low battery condition is also present. (Please refer to the description of alarm messages for status channel of “7”) For these radios, the low battery message will be repeated when other trouble conditions are reported (where the status channel = ‘6’). The low battery message will be sent directly following the trouble message In addition, the low battery message will also be sent when any alarm or restore is reported. These radios do not have a specific Low Battery Restore message. After a low battery condition is received, a Low Battery Restore is implied when the next alarm or Open/Close message is received with a ‘7’ in the ninth channel rather than an ‘8’.

AlarmNet Message Definitions

AlarmNet®

Page 20

Status Channel = 9 (Installer generated test message)
Message cccc 5555 5555 9 Definition: System Test Message    Manually triggered test from the device Test signal generated by an AlarmNet Network Technician for a specific subscriber. (For AlarmNet-A only) 24-hour Network Acknowledgement of Subscriber Status messages Applies to: A, G, I, M

Note: for older 7620 and 7620ULF radios, Zone alarms may also be sent at the same time as a test message. These messages will be in the identical formats to those alarms shown for Status Channel 5 or 8, except that the status channel will be a 9.

AlarmNet Message Definitions

AlarmNet®

Page 21

Section # 2 - Glossary
Item
AC Loss

Description
Indicates that the device has detected a loss in its external supply line voltage through the transformer or power supply, and is currently operating on battery backup power. Indicates that external power to the device has been restored. AlarmNet-A is the original group of regional area networks that are owned and operated by AlarmNet in a number of major metropolitan areas throughout the U.S. AlarmNet-A is UL listed for Line Security, (UL AA), when using the 7920SE. AlarmNet-G is an AlarmNet service that uses the GSM digital cellular system and has SMS capability for backup alarm delivery. Some communicators in this service utilize a secure internet connection for alarm delivery in addition to the GSM connectivity. AlarmNet-I is an AlarmNet service that uses a secure internet connection for alarm delivery. The AlarmNet-I service is also UL listed in the U.S for Line Security (UL AA), and with ULC in Canada as Level 2. AlarmNet-M is the name for the AlarmNet service provided through the "Mobitex" network in the U.S. and Canada. The AlarmNet-M service is also UL listed in the U.S for Line Security (UL AA). After a subscriber device is installed, it begins to broadcast a diagnostic or check-in message at regular intervals. These messages have two purposes: 1) When an AlarmNet-A radio is first installed, and before the radio becomes supervised, these signals are logged by each network node that hears it and these messages are also transmitted to the Central Station. 2) After the network has begun supervising the radio, the A-Type Diagnostics are used by the network to supervise the radio and to ensure that it is communicating properly, but these messages are no longer transmitted to the Central Station. The A-Type Diagnostic message is sent to the Central Station at 12-hour intervals by each network node that receives transmissions from any unsupervised subscriber. These diagnostics will continue for as long as the subscriber remains unsupervised, and in certain instances where assignment takes longer than usual, will even be reported over several weeks and beyond. Once an account becomes supervised, it is no longer subject to diagnostic evaluation, and A-Type Diagnostics will no longer be sent to the Central Station. One-Way radios begin transmitting their A-Type Diagnostics soon after the radio is powered up. They will transmit a diagnostic message either once per hour or every 15 minutes if the 6-hour supervision option has been programmed. In order for the 6-hours supervision to work, AlarmNet must be notified by noting so on the Contract or Request for Service for that subscriber. Two-Way radios, 7920SE, transmit their diagnostic message in response to polling signals transmitted by the AlarmNet-A network. The network will transmit a polling signal for a particular radio once it has heard a transmission from that radio. Such transmissions include the initial Power-On Reset signals produced when the radio is first powered up and any asynchronous messages (e.g. alarms, troubles, or “I’m not being polled” messages) generated.

AC Loss Restore AlarmNet-A

AlarmNet-G

AlarmNet-I

AlarmNet-M

A-Type diagnostics

AlarmNet Message Definitions

AlarmNet®

Page 22

Before a radio can be assigned supervision by the network, AlarmNet must: 1) have a contract or request for service on file for that radio AND 2) determine how well the radio is being heard by different network nodes. While the radio is unsupervised, the account is said to be in a “Diagnostic Mode” and is assigned a 12-hour Diagnostic Rate (or Diag Rate). The signals produced by the account during each 12hour period are evaluated in terms of their strength and consistency. During this 12-hour period, any network node that hears transmissions from these radios will compile an A-Type Diagnostic for delivery to the account’s Central Station. This means that the Central Station could receive several A-Type Diagnostics for each newly installed subscriber account. After 60 days of being unsupervised, the interval between successive A-Type Diagnostics will increase to 24 hours. (Please note that after 60 days, if the radio is not supervised because AlarmNet has not received a Contract or Request for Service for that radio, an additional surcharge will be added to its monthly charge.) Although the A-type diagnostics contain important information for AlarmNet, as far as the Central Station is concerned, receipt of the A-type Diagnostic message merely provides confirmation that the newly installed account is being heard from until it is assigned supervision in AlarmNet Direct by the Central Station or AlarmNet technical support. Note: AlarmNet-A radios will remain unsupervised until the diagnostic information from the passing tower(s) is entered into AlarmNet Direct by the Central Station or AlarmNet technical support. See also: “F-Type Diagnostics” and “Pass-Fail.” Check 685 Printer This message is reported when an atypical system message is reported that may not normally be passed on to the Central Station’s automation system. The “Check 685 Printer” message indicates that the operator should refer to the printer output for an important message. Such messages include:  A-Type diagnostics  F-Type diagnostics  Keyed-on subscriber  Repeating alarm suppressed  Redundant supervision warning  Multiple nodes down  2-Way radio internal tamper  Subscriber Command Failure  Unregistered subscriber  Central station Comm Fail  Database Update in Progress  Master/Host Alarm  Central Station Poll Timeout Another name for any supervisory signal sent from the radio. See “Communications Failure Message” Generated when a subscriber fails to check in with the network during its predetermined supervision interval.

Check-in Comm Fail Communications Failure Alarm

AlarmNet Message Definitions

AlarmNet®

Page 23

Communications Failure Reminder

Communications Failure Reminders are sent every six hours for AlarmNet-A accounts, to remind the Central Station that a subscriber continues to be in Communications Failure with the network. For all subscribers except AlarmNet-A, Comm Fail Reminders are sent to the Central Station. They are also printed on the Weekly Status Report. This report shows the subscriber number and the number of reminder messages the network would have generated. This means that Communication Failure messages will be sent ONLY ONCE for these devices.

Communications Failure Restore Database Update in Progress

A Communications Failure will restore when the network again hears from the device in question. Comm Fail Restorals are sent for all types of communicators. The AlarmNet networks must be updated periodically with new subscriber information. When an AlarmNet-A network node is given an update, it may be temporarily unable to transmit while it applies the new database. This message is sent as a general notification, and is typically for informational purposes only. (Note that there is no restore message associated with this condition) See “A-Type diagnostic” or “F-Type diagnostic” This message is unique to the 7720V2. It indicates that the radio is coming out of battery charging mode. This message will be received after the following sequence of events has occurred: • During normal operation, the transmitter detects that its battery is so weak that it cannot sustain a radio transmission. (A low battery message has been previously sent.) • At this time, the radio automatically enters battery charging mode. Note that while it is charging the battery, the radio is not capable of transmitting messages. (If the fault relay is used, it will activate at this time, indicating that the radio will not be transmitting any alarms.) After the battery has been sufficiently charged, the radio will send the message shown. This indicates that the radio has exited battery charging mode, and is again ready to transmit. (If it is programmed for latching operation, the fault relay will be restored at this time.) The radio then reviews the status of all of the channels (zones) and sends their current status. If a channel (zone) connected to the radio went into alarm during the charging period and is still in alarm when charging is complete the radio will send that alarm following the message.

Diagnostic signal

Exiting battery charge mode

Fire Supervisory Fault

A supervisory fault is an indication of an open circuit in one of the control’s initiating circuits, and implies that one or more of the system’s initiating devices would not cause an alarm if they were to activate. Note: Supervisory Restores are not a programmable option as are alarm restores, and therefore are automatically transmitted. Note: Due to the fact that the 7620ULF is not a fire alarm control, supervisory faults from the fire control panel may be used to trigger one or more of the eight channels on the 7620ULF, and thus will be reported as alarms. The Central Station should be aware of which of the eight channels are actually reporting supervisory conditions so alarm reports for these channels can be responded to correctly. Note: Supervisory messages may also be sent from a 7920SE if it is installed with an applicable Ademco control and “Ademco Supervision” is used to monitor the wiring between the Ademco control and the radio. In this configuration, only the first 6 channels are relevant.

AlarmNet Message Definitions

AlarmNet®

Page 24

Fire Supervisory Restore Fire trouble F-Type Diagnostics

Supervisory Restores are not a programmable option as are alarm restores, and therefore are automatically transmitted. see “Fire Supervisory Fault” Both One-Way and Two-Way AlarmNet-A radios are each capable of producing manually triggered diagnostic messages that help determine how an account is performing. To transmit these messages typically requires that a technician visit the account. Whenever an F-Type Diagnostic message is produced by a subscriber account and is detected by any of the network’s Master Stations, it is evaluated and then reformatted for delivery to the Central Station. Unlike the A-Type Diagnostic, the F-Type Diagnostic can provide more practical information to the Central Station that can be directly utilized to obtain the best radio performance possible. Each network node that has received the radio’s transmissions formulates an F-Type Diagnostic message. The message sent to the Central Station contains data on the signal strength, frequency, and modulation characteristics of the signals produced by the subscriber radio being evaluated. Note: The manner in which One-Way and Two Way radios are manually triggered to produce FType Diagnostics are covered in their respective Installation Instructions. While the quantity of such messages produced will vary among Two-Way radios. One Ways are designed to transmit approximately 60 such messages over an interval of several minutes. Note: AlarmNet-A radios will remain unsupervised until the diagnostic information from the passing tower(s) is entered into AlarmNet Direct by the Central Station or AlarmNet technical support. See also: “A-Type Diagnostics” and “Pass-Fail.”

Illegal (Unregistered) subscriber

This message is received when a radio is programmed for an account that does not exist in the AlarmNet database. The account number that is being transmitted is displayed in the message. When such a message is received, the Central Station should check with its installers and/or dealers to identify recently installed radios, and confirm whether or not there was an error in programming the subscriber account number for one of them. If the source of the report can not be determined, contact AlarmNet Technical support. (Note that there is no restore message associated with this condition) This message indicates that a subscriber is continuously transmitting. Such reports may be sent at intervals of about six minutes, and from each network node detecting the condition. Under the worst conditions, such a radio will transmit until it is physically powered down. Action may be required. If the report for a keyed-on subscriber is received, note the account number, the reporting node, and the time. It is likely that additional reports of the same event will be received from other network nodes that hear the radio being reported. Six minutes later, note if any subsequent reports of the same event are reported. If so, contact AlarmNet technical support at (800) 222-6525. Based on instructions from AlarmNet, you may need to have the service personnel that are responsible for the radio disable it. Applies to the GSM series radios only when programmed for 4204 emulation mode. The radio is connected to the panel, using the ECP bus (Enhanced Console Protocol aka keypad wiring). In either of these modes, if the radio detects that it is no longer in communication with the control panel, it will send this message. This may occur if the keypad wiring is cut or shorted, or if the control is no longer functioning. A “Check message” may also display on the control panel’s keypad. AlarmNet® Page 25

Keyed-on subscriber

Loss of ECP Supervision

AlarmNet Message Definitions

Loss of ECP Supervision Restore
Master-Host Alarm

Applies to the GSM series radios only when programmed for 4204 emulation mode. When the radio has resumed communication with the control panel, it will send this restore message. AlarmNet-M is configured redundantly with a Primary (account # 0000) and Secondary (account # 0001) receiving system. Each consists of its own separate antenna system, a 7810R radio transceiver, which is connected to a 685-5NR radio line card in its own 685 receiver. Both receiving systems are live and powered up at all times, with messages normally sent to the Primary system. If one system fails, the network will automatically route messages to the other. At the time of such a failure, both a Master-Host Alarm and a Master-Host Reminder are generated. The Master-Host Alarm message is generate internally by the 685 that has failed. It indicates that its particular receiving system is having a problem connecting to the network. The Master-Host Reminder is generated by the network and is reported to the other, operating receiving system. It indicates that the other part of the redundant system is having a problem connecting to the network. Example:  During normal operation, all messages are being properly reported to the Primary receiving system of a central station.  A storm damages the antenna system to the Primary system, severing its connection to the AlarmNet-M network.  The 685 for the Primary receiving system will display the Master-Host Alarm, indicating that it has lost network connection  A few moments later, the Secondary system will display the Master-Host Reminder, indicating that the Primary has lost network connection.  The Secondary will immediately begin receiving all alarms and messages that normally would have gone to the Primary Such a condition may be caused by:  Antenna failure  Radio receiver failure  Substantial interference  Network outage

Master-Host Reminder

See also “Master-Host Alarm.” This message is generate by the network about the failure of one part of the redundant AlarmNetM receiving system and reported to the functioning part of the receiving system. It indicates a failure of a 685 to connect to the AlarmNet-M network. This message indicates that the Central Station transceiver has resumed hearing network activity. This message is similar to the “Redundant supervision warning” except that it concerns more than one network node. The specifics and conditions relating to the “Redundant supervision warning” apply to this message as well, as does the method of identifying the node in question and which subscribers it affects. See “Redundant supervision warning” Tells the Central Station to refer to their fax machine for further instructions

Master-Host Restore Multiple nodes down

Network Alert Message

This message is part of an automated method of informing the Central Station of Network related issues that may impact it and/or its device subscribers. Such issues may include conditions such as a tower out of service for remedial or scheduled maintenance, or other unforeseeable performance degradations that might result in missed or false signals. AlarmNet Message Definitions AlarmNet® Page 26

This process consists of two parts. When an alert condition is triggered, the message shown will be sent. At the same time this message is sent, a fax and/or e-mail transmission will be sent to the Central Station, at a pre-determined number and/or e-mail address. The purpose of the “Network Alert” message is to direct the operator or Central Station manager to refer to this fax or e-mail transmission. The transmission contains important details about the “Network Alert”. The receipt of this message should require the central station operator to refer to their fax and/or e-mail for further information and instructions from AlarmNet. The faxed or e-mail transmission should be read by an appropriately responsible Central Station Supervisor as it contains critical information that may pertain to the safety of your subscribers, and will require necessary action. Node Down Pass-Fail See “Redundant supervision warning” or “Multiple nodes down” An enhancement that allows the Central Station to verify the installation quality for AlarmNet-A One-Way radio transmitters based on the radio’s signal strength and consistency as heard by the network. When an installer triggers the test signal on the radio the C/S will receive an “A” or an “F” contained in an F-Type Diagnostic message. The letter “A” (“Acceptable”) indicates the Repeat Count and the Signal Strength meet the minimum acceptable requirement. If the Repeat Count or Signal Strength are lower then the minimum requirements the letter “F” (“Fail”) will be displayed. This feature can be activated upon request for AlarmNet-A network C/S only. When a One-Way radio sends a test message, it typically generates 30 pairs of transmissions over a 90 second period, producing a total of 60 messages. Once a network node hears the first transmission, it begins to track and count them for an additional 90 seconds. For any node to perform the Pass/Fail evaluation, it must hear at least one such transmission. The Repeat Count

is the number of messages heard of the 60 transmissions sent. The Signal Strength is an average of those messages put on a scale of 1 – 10, where 10 is the best signal strength.
Unless the Central Station requests differently, the minimum acceptable levels of signal strength and repeat count used in the evaluation are set to AlarmNet’s defaults, which are: 1) Repeat Count should be at least 21 transmissions (out of 60) 2) Signal Strength must be 3 or greater (of 10) 3) Signals must be heard within the specified 90-second time frame. Note that at the request of the Central Station, the default criteria can be changed to suit their needs When a network node evaluates a set of transmissions for Pass-Fail, unless 21 or more total are heard from the account within the 90-second time period, the radio will be failed, regardless of the signal strengths involved. If 21 or more transmissions are heard within the specific time period, they will then be evaluated based on the average strength of the received signals. If it is equal to or greater than the specified threshold of 3, the account will be passed. To use the Pass/Fail to evaluate the transmission strength of a radio, place a 7720 One-Way radio in “test” using either of the following methods: 1) With the No. 7720 Programming Tool Connect the No. 7720 Programming Tool to the jack on the 7720. Press Shift + T (the TEST command) to initiate the radio’s production of 60 test messages. Note: If it is desired to end the test transmissions before the conclusion of the cycle, simply press Shift + T again. Note that doing so will likely cause the account to be failed in the resulting Field-Triggered Diagnostic message(s) if the required Repeat Count has not been AlarmNet Message Definitions AlarmNet® Page 27

met. 2) Manually Triggered Test With the radio producing no transmissions (its green LED will be OFF), momentarily connect a wire jumper between its +DC CHARGING VOLTAGE terminal and its TEST INPUT terminal to initiate the sequence of 60 test messages. Note 1: Be sure that the radio’s test input is programmed for normal (not inverted) operation. Note 2: Before initiating the test message, be sure the radio’s yellow LED is the only LED lit and is flashing once per second, indicating that the radio is ready to transmit. Slower flashing typically indicates an uncharged battery. The technician should contact either the Central Station or AlarmNet to obtain the results. Note that any test process, is not a priority within the network and it may take several minutes (or more), before the network will deliver the resulting F-Type Diagnostic message. Note: The Pass-Fail feature will not work for the model 7620 One Way radios since these radios transmit an insufficient number of such messages within the specified “time window” required for the evaluation. See also “F-Type Diagnostics”
Poll timeout

The 7920SE Two-Way radio has a feature that is referred to as "Poll Time Out" that is used internally in the AlarmNet-A Network. This message is usually not sent to the Central Station. The only circumstances under which this message is sent, is if something is not set up properly within the Network for a subscriber. A "Poll Time Out" message received in the Central Station indicates the Network has heard from a Two-Way radio, but the Network's database has been told that this subscriber number should be for a One-Way radio.
RADIOS SENDING THIS MESSAGE ARE NOT BEING POLLED.

If this message is received for a subscriber, the Central Station must notify AlarmNet that it is a Two-Way radio and to change the subscriber database record to reflect a Two-Way, or if the TwoWay radio is incorrect, to replace the Two-Way radio with a One-Way radio. Power-on reset This message reports that the radio has lost both AC and battery power and then had either the AC or the battery restored, causing the radio to reset. The only time that this message is normal is when:  The account is a new install and the installation personnel are still on the premises.  Service personnel are on the premises and the account has been put on test.  The loss of all power was due to an explainable and verifiable event that can be immediately confirmed. For ‘A’ radios, it is possible that a legitimate radio may have been removed from service and replaced with another radio programmed to the same subscriber ID number. Such a new radio may or may not be connected to the alarm control at the subscriber’s premises. If an illegitimate radio that is not connected to the alarm is used to replace a legitimate radio, strictly for the purpose of maintaining a secure radio connection while the alarm system is violated, the powerup reset message will be sent to the Central Station from the new radio, thereby alerting the AlarmNet Message Definitions AlarmNet® Page 28

Central Station to the possibility of such a condition. If the reasons for receiving this message cannot be immediately explained with positive confirmation as to one of the above conditions, it is possible the radio is being tampered with and it is recommended that it be treated as an alarm and action be taken in accordance with the Central Station’s normal procedures. If this message is received reference the Central Station (i.e. Account # 0000) this indicates that the Central Station 685 receiver has been reset. This action would also reset the Central Station radio transceiver, which would generate this message. Redundant supervision warning This message indicates a potential problem with the local AlarmNet-A network. The AlarmNet-A networks are designed with overlapping coverage, and often two nodes are designated as being responsible for the supervision of a subscriber radio. This message indicates that an AlarmNet-A network node is down (not working), and that node is responsible for supervising at least one subscriber belonging to the Central Station as either a primary or secondary node. Note that this message does not indicate which node is down, or which subscribers are affected. It simply indicates that there may be a potential problem with the supervision of one or more subscribers. Keep in mind that many accounts are supervised by two network nodes, and alarms are repeated multiple times and handled by any node that hears them. Once the problem node has been identified, you may determine which subscribers are affected by the problem by reviewing the Central Station Report that is sent to the Central Station each month. (For AlarmNet-A ONLY.) The primary node responsible for this radio detects five separate but identical alarm reports within an 8-minute time period. The first five alarms are reported as the network normally would deliver them. However, instead of the sixth alarm, the “Repeating Alarm” message will be sent. Future messages that are identical to the suppressed alarm will not be sent for the next 25 minutes. It is important to note that unless the radio has been programmed to generate restore signals, the network will be unable to produce the “Repeated alarm” message, and in this case, all repeated alarms would be reported to the Central Station. See “Keyed on Subscriber” Another name for A-Type diagnostic. See “A-Type diagnostic” A time period during which the network expects to receive a signal or poll response from a radio. The network will then check with other network nodes to determine if the radio was heard elsewhere. If it is determined that the radio has indeed failed to respond during this interval, it will be considered in Communication Failure, and a Comm Fail message will be sent to the Central Station. A frequent and generally unwarranted repetition of the same alarm condition. (Note, ‘swingers’ are rarely the fault of the radio itself and are almost always related to the sensors or wiring of the alarm system. A method to reduce unnecessary alarm reports. See “Repeating alarm suppressed”

Repeating alarm suppressed

Runaway Status Message Supervision interval

Swinger

Swinger suppression System Supervisory Fault System Supervisory Restore

This message indicates that the 7720ULF has either detected a problem with “Bell Supervision”, or has detected a “Ground Fault”. This message is sent when the condition causing the original fault has been cleared.

AlarmNet Message Definitions

AlarmNet®

Page 29

Two-Way radio Poll Timeout

Under normal circumstances, a two-way radio (7920SE) is queried, or “polled”, by the AlarmNetA network node that is primarily responsible for the radio. The radio is supposed to respond to these polling signals, or else the network will send a communication failure report (Comm-Fail) for that account, indicating that it is not functioning properly or has lost connection with the network. The poll rate is determined by the configuration of the account in the network’s database. The “Two-Way radio Poll Timeout” message would be sent for the following conditions:  If a two-way radio is programmed improperly for a one-way radio account number, which would not have the proper polling rate. Reprogram the radio to a two-way number.  For some reason the polling rate is not properly set. Contact AlarmNet.  The 952 Mhz receiver in the two-way radio has become inoperative, and the radio can not hear polling signals. Dispatch. If this message is received for a subscriber, the Central Station must notify AlarmNet that it is a Two-Way radio and to change the subscriber database record to reflect a Two-Way, or if the Two-Way radio is incorrect, to replace the Two-Way radio with a One-Way radio. If this message is received with reference to the Central Station (i.e. on account # 0000) then it may indicate:  The “receive” portion of the Central Stations radio transceiver may be operating marginally, still capable of receiving some data from the network, but missing most of it, including polling signals.  The Central Station may already have received a Comm Fail report, causing the network to poll it less frequently, and, coupled with poor signal reception, could possibly produce this report as well.  A highly unlikely condition where both the primary and secondary towers for the Central Station are down.

Two-Way radio Poll Timeout Restore Walk test

The radio transceiver has resumed hearing polling signals from the network

This message indicates that the fire system at the protected premises has been placed into the “Walk Test” mode. While the system is in this mode, service or installation personnel can test the functionality of the system without transmitting any alarm signals to either the Central Station or the Fire Station. Once the service or installation person exits the “Walk Test” mode, or if no zone triggers occur for 30 minutes, the Central Station will be sent this message indicating the system is no longer in the “Walk Test” mode and the system has been reset.

Walk test exit

AlarmNet Message Definitions This Version Dated 02/07/2011
AlarmNet Message Definitions AlarmNet® Page 30


Uploaded