Interlogix 60-807-01-95R - Installation Manual



Related Products

Interlogix 60-807-01-95R - Wireless SAW Pet Immune PIR Motion Detector
Interlogix 60-807-01-95R
Wireless SAW Pet Immune PIR Motion Detector

Related Categories


Document Transcript

P/ N
466
-
1837

• REV
B


23FEB11

1


Pet Immune SAW PIR Motion Sensor with
Lithium Battery Installation Instructions


Product summary

A motion sensor (passive
-
infrared or PIR) detects movement
within a specific area by sensing the infrared energy emitted
from a bod
y as it moves across the sensor’s field of view.
When this motion is detected, the sensor transmits an alarm
signal to the control panel.

Use this motion sensor to protect locations where door/window
sensors are impractical or not needed. For example, use
a
motion sensor to protect large areas or open floor plans.
Motion sensors also provide backup protection for door/window
sensors.

The Pet Immune SAW PIR (60
-
807
-
01
-
95R) utilizes advanced
signal processing, a new custom designed lens, and a new
custom desi
gned sensing element. The combination of these
improvements provides false alarm immunity for pets with a
combined weight of up to 40 pounds (18 kg) while still
providing superior human catch performance.



This wireless motion sensor includes the followin
g
features:



35 feet by 40 feet coverage area



Three minute transmitter lockout time after an alarm that
helps extend battery life



Cover
-
activated tamper (optional wall
-
activated tamper is
included)



Supervisory signals transmitted every 64 minutes to

the
control panel



Sensor low battery reports (trouble) to the control panel



Field
-
selectable sensitivity options (standard setting
required for pet applications)



Compatible with all Learn Mode control panels

Installation

guidelines

This PIR was desi
gned for indoor use in the presence of pets
having a combined weight of up to 40 pounds (18 kg). The
following installation guidelines must be met to provide this
false alarm immunity.



The sensor must be incline
-
mounted on a wall surface or
incline mount
ed in a corner at a mounting height of 7.5
feet (2.3 m) (see
Figure

4

on page 2
).



The sensitivity switch must be set to Standard.



The pet must not be allowed to climb on objects such as
furniture, boxes, etc. within the field of coverage. See
Figure

2

on page 2

and
Figure

3

on page 2

to determine
the sensor’s

field of coverage.



Room temperature must be kept between 60º and 120° F
(16º and 49º C).



Do not aim the sensor at windows, fireplaces, air
conditioners, area heaters, forced air heating vents, or
place it in direct sunlight.



Windows should be closed

in any area which has an
armed motion sensor.



Position the sensor to protect an area where an intruder
would be most likely to walk
across

the detection pattern
(see
Figure

1

on page 2
).



Mount the motion sensor on a rigid surface which is free
from vibrations.



Mount the sensor permanently on a flat wall or in a corner.
Do not set it on a shelf.



Mount the motion sensor on an insulated, outside wall
facing in.



Position the sensor so
it faces a solid reference point, like
a wall.

2


Pet Immune SAW PIR Motion Sensor w ith Lithium Battery Installation Instructions



If possible, locate sensors within 100 feet (30.5 m) of the
panel. While a transmitter may have a range of 500 feet
(152 m) or more out in the open, the environment at the
installation site can have a signif
icant effect on transmitter
range. Sometimes a change in sensor location can help
overcome adverse wireless conditions.



Do not mount the sensor near duct work or other large
metallic surfaces which may affect the RF signals (see

Final Testing

on page 4
). Actual acceptable transmitter
range should be verified for each installation.

Figure

1
: Top view of lens coverage area


Figure

2
: Side v
iew at a m ounting height of 7.5 feet


Figure

3
: Overhead detection path


Mounting the motion sensor

This sensor must be incline
-
mounted on a wall surface or
incline mounted in a corner at a mounting height of 7.5 feet.

Figure

4
: Wall m ount options


Figure

5
: PIR m ounting plate knockouts


To mount the sensor:

1
.

Remove the mounting plate by depressing the button on
the top of the sensor body. With the opposite ha
nd pull the
mounting plate away from the body of the sensor.

2
.

Punch out two of the bottom four mounting holes (see
Figure

5

above
) to determine which knockouts to use
when
mounting the motion sensor. Use the lower
-
side
holes for corner mounting, or the lower
-
middle holes for
surface mounting.

3
.

If you desire wall
-
tamper functionality, remove the wall
-
tamper knockout (see
Figure

5

above
).

Note
: The wall
-
tamper switch cannot be used when the
sensor is corner mounted.

4
.

Mark the location of the required holes on the mounting
surface.

5
.

Use wall anchors and screws
to secure into place. Attach
the sensor to the mounting plate.
Pet Immune SAW PIR Mot ion Sensor w ith Lithium Battery Installation Instructions


3

6
.

When testing is completed the PIR can be securely
attached to its mounting plate by screwing the smallest
enclosed screw into the mounting plate hole at the top of
the mounti
ng plate (see
Figure

7

belo
w
).

Setting the sensitivity on the indoor motion
sensor

For pet applications, the PIR must be set to standard
sensitivity.

Figure

6
: Sensi
tivity pins locations


Testing

Walk Testing

Walk testing should be done to determine the sensor’s actual
coverage area. The edge of the coverage pattern is
determined by the first flash of the LED. This may change
slightly depending upon the sensitivity s
etting. Walk test the
unit from both directions to determine the pattern boundaries.

1
.

Remove the sensor body from the mounted mounting
plate, activate the tamper switch, and then remount the
body to activate the 60 second walk test mode
.

2
.

Walk across the coverage pattern to determine the
coverage area, indicated by LED activation. Each
activation extends the walk test mode for an additional 60
seconds.

After 60 seconds without motion the walk test mode times out
and the

LED will no longer activate when motion is detected.

Caution:
Excessive use of the walk test mode may reduce
battery life. Use only for initial setup and maintenance testing.

Note
: When the walk test mode has ended, an alarm can be
transmitted only after
3 minutes have passed since the
previous alarm. This 3 minute lockout time reduces
unnecessary RF transmissions in high traffic areas thereby
extending battery life.

Environment testing

Turn on all heating or air conditioning sources which would
normally b
e active during the protection period. Stand away
from the sensor and outside the coverage pattern and watch
for alarms.

Maintenance

At least once a year, the range and coverage should be
verified for proper operation. The end user should be instructed
to
put the sensor in walk test mode and walk through the far
end of the coverage pattern to verify proper detection.

Replacing and Disposing of Batteries

The sensor is powered by 1 AA Lithium battery. When the
system indicates the sensor has a low battery, re
place it
immediately.

When battery replacement is necessary, observe proper
polarity (as shown in the battery compartment) when installing
the new battery, or the sensor may be damaged. Be sure to
note that as you look at the battery compartment, on the le
ft
side the positive battery end is down and on the right side the
positive end is up. When the battery is replaced, wait at least 3
minutes before activating the walk test mode.

Caution:
Replace only with 1 AA lithium battery. Observe
polarity when instal
ling the new battery. Installing the battery
backwards may cause damage to the sensor. Dispose of used
batteries according to the manufacturer’s instructions, and/or
local government authorities. See
Figure

7

below

for the
battery location.

Figure

7
: PIR com ponents


Programming

Refer to the panel installation instructions for information on
programming the sensor into the panel.
4


Pet Immune SAW PIR Motion Sensor w ith Lithium Battery Installation Instructions

To trip the sensor:

1
.

Remove the PIR from its mounting plate activating the
tamper switch.

2
.

Exit the panel’s programming mode.

3
.

Return the PIR to its mounting plate.

Final Testing

Final testing should be done to verify radio signal integr
ity and
confirm control panel programming and response. The actual
transmitter range can be determined by performing a sensor
test as follows:

1
.

After the sensor has been mounted, remove it from its
mounting plate and activate the tamper

switch to start the
walk test mode.

2
.

Replace the sensor in its mounting plate.

3
.

Place the control panel in test mode. Move across the
detection pattern until the sensor’s LED turns on. STOP
your motion.

4
.

Listen for the appropriate system response. If the system
does not respond, proceed to “
Troubleshooting

below
.

Troubleshooting

Use the following guidelines if the system does not respond

correctly when the sensor is activated.



Check programming and reprogram sensor into panel if
necessary.



Move the sensor to another location and test for correct
response.

To relocate a sensor:

1
.

Test the sensor a few inches from th
e original position.

2
.

Increase the distance from the original position and retest
until an acceptable location is found.

3
.

Mount the sensor in the new location.

4
.

If no location is acceptable, test the se
nsor as described
below:

Test a known good sensor at the same location.

If the system does not respond, avoid mounting a sensor
at that location.

If the replacement sensor functions, return the problem
sensor for repair or replacement.

Specifications

Compa
tibility

Simon®, Concord

, Concord Express,
SuperBus® 2000 RF Receiver, Quik Bridge®
1 & 2 Channel and Loop Receivers

Pow er source

1 AA Lithium battery; Part # 60
-
619 (six
batteries per pack)

Typical battery lif e

4
-
6 years at 68° F

Transmitter f requency

319.5 MHz

Operating temperature

32° to 120° F (0° to 49° C) Non
-
pet
applications

60° to 120° F (16° to 49° C) Pet applications

Storage temperature
range

-
30° to 140° F (
-
34° to 60° C)

Maximum humidity

90% Relative Humidity non
-
condensing

Dimensions

2.
9 in. (7.4 cm) x 2.4 in. (6.1 cm) x 1.9 in. (4.8
cm) (L x W x H)

Regulatory information

Manuf acturer

UTC Fire & Security Americas Corporation, Inc.

1275 Red Fox Rd., Arden Hills, MN 55112
-
6943,
USA

FCC compliance

These devices comply w ith part 15 of the
FCC
rules. Operation is subject

to the f ollow ing tw o
conditions:

These devices may not cause harmf ul
interf erence.

These devices must accept any interf erence
received, including interf erence

that may cause
undesired operation.

Changes or modif ications not
expressly approved
by UTC Fire & Security can void the users’
authority to operate the equipment.

Contact information

www.utcfireandsecurity.com

or
www.interlogix.com

For cust
omer support, see
www.interlogix.com/customer
-
support


©

2012 UTC Fire & Security Americas Corporation, Inc.

Interlogix is part of UTC Climate Controls & Security, a unit of
United Technologies Corporation.



All rights reserved.


Uploaded