Qolsys IQ Door Window-S QS 1133-840 Installation Guide
Related Products
Related Categories
- Wireless Door Sensors and Window Alarm Sensors
- Wireless Door Alarm Sensors
- Encrypted Door Alarm Sensors
Document Transcript
STEP
1
CHOOSE
INSTALLATION
LOCATION
✓
Exterior Doors
✓
Sliding
glass
doors
Windows
✓
Installation Notes: It is highly recommended to attach
the sensor to the top of the door or window on the fixed
frame and the magnet to the door or window. Ensure
that the magnet is located not more that 6mm (0.25
inches) from the transmitter’s marked sides.
IMPORTANT!
For UL/cUL, perform a placement test first
for all wireless initiation devices. The acceptable result
shall be “Excellent".
IQ DOOR/WINDOW S-LINE INSTALLATION MANUAL
SPECIFICATIONS
Sensor: 2.65”H x .85”W x .75”D
Compatible control panels: Qolsys IQ Panel 2
Code outputs: tamper, tamper restore, alarm, alarm restore, low battery.
Frequency: 319.5MHz
Transmitter frequency: SECURE 319.5 MHz (S-Line)
Unique code ID
Supervisory keep-alive interval: 70 minutes.
RF Peak field strength: typical 36000 uV/m at 3m
Operating Temperature: 0 ̊C~49 ̊C
Relative Humidity: 85% Max
Storage Temperature: -40-85 ̊C
For indoor non-hazardous locations only.
Battery: 3V Lithium CR2
Replace battery with exact replacement every 5 years.
Low Battery Threshold: 2.6V
IQ Door/Window-S
Note: For UL/CUL installations use this device only in conjunction
with compatible Qolsys wireless alarm system IQ Panel 2.
STEP
2
STEP
4
SECURE
BACKPLATE
REMOVE
BATTERY
TAB
STEP
3
LINE UP
SENSOR &
MAGNET
Apply provided screws
to the backplate of
magnet.
Magnet gap should
not exceed 1/4”
Please refer to table A
on page two for
detailed specifications.
Magnet locator marks. Magnet can be
placed on either side of sensor.
Magnet
Sensor
X2
Note: for UL/
cUL certified
installations use
only screws for
mounting the
device.
STEP
5
SECURE
MAGNET
X2
OVERVIEW
The IQ DW-S Door and Window Contact is a fully supervised magnetic contact
device. It includes a built-in reed switch (that opens upon removal of a magnet
placed near it). The device transmits alarm notifications to the control panel and
is supervised. Operating power is obtained from an on-board 3V lithium battery.
When the battery voltage is low, a “low Battery” message is sent to the receiver. Document#: IQDW-SIM-02-18
Revision#: 02/19/18
Issue Date: FEB 2018
Qolsys Product #: QS1133-840
STEP
6
LEARN
INTO
PANEL
Place your panel in
“auto learn" mode
Customize name and settings as
desired and touch “ADD”
ADD
Open and close the case
to “tamper” the device
TABLE
A
GAP
SEPARATION
Axis
Magnet Approaching
Contact (mm)
Magnet leaving
Contact (mm)
Steel
X
7
8
Steel
Y
10
13
Steel
Z
17
22
Wood
X
19
23
Wood
Y
14
19
Wood
Z
27
32
Axis Z
Axis Y
Axis X
TechSupport@Qolsys.com
CONTACT TECH SUPPOR
T
GOT QUESTIONS?
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et
(2) cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.
The IQ DW-S has been listed by UL/cUL for residential burglary applications in accordance with the requirements in the Standards UL 634 and ULC/ORDC634 for Door and Window Contact.
Qolsys Inc. proprietary.
Reproduction without permission is not permitted.
FCC ID: 2ABBZ-RF-MDWS-HP-S
IC: 11817A-RF
MDWSHPS
Equipment
BP21056
BATTERY SAFETY AND MAINTENANCE
The IQ Door/Window-S includes low-battery condition detection. When this condition is detected a trouble message is transmitted to the
compatible receiver/control panel. This will provide visual identification of the unit that requires a battery change.
This product uses lithium batteries. Improper handling of lithium batteries may result in HEAT GENERATION, EXPLOSION or FIRE, which
may lead to personal injuries. WARNING!
DANGER OF EXPLOSION IF BATTERIES ARE INSTALLED INCORRECTLY. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE
RECOMMENDED BY THE MANUFACTURER.
KEEP AWAY FROM SMALL CHILDREN: IF SWALLOWED PROMPTLY SEE A DOCTOR.
Caution! Risk of explosion if battery is replace by an incorrect type. Dispose of used batteries according to the manufacturer’s instructions.
Do not try to recharge these batteries.