PROA7
RESTORE DOCUMENT

Condition?

Zone type 06

Silent Panic

Zone type 07

Aud Panic

Zone type 08

Auxiliary

When is restore report
sent?

After
Bell Timeout or
Disarm


After
alarm is cleared

or
bell timeout

After Code is entered

When can
you re
-
trip a
Button
Zone?

Restore is not sent till Bell
timeout, but zone will trip
again right away.

Restore is not sent till Bell
timeout, but zone will trip
again right away.

Right Away

When can you re
-
trip a
RF Zone?

Restore is not sent till
Bell
tim
eout
, but zone will trip
again right away.

Restore is not sent till
alarm
cleared
, but zone will trip
again right away

Restore is not sent till
disarm, but zone will trip
again right away

Affected by bell time
-
out?

Restore is sent at bell
timeout if
zone is restored.

Restore is sent at bell
timeout if zone is restored.

Restore is sent at bell
timeout if zone is restored.

What if bell time out is
set at zero?

Restore is not sent till
disarm, but zone will trip
again right away

Restore is not sent till

alarm
cleared
, but zone will trip
again right away

Restore is not sent till
disarm, but zone will trip
again right away

What if
alarm is cleared

and the zone is
still
faulted

Restore report is sent

when a
Disarm is done

Restore report is sent

Restore report is sent

What if
alarm is cleared

and the zone IS closed?

Restore report is sent

Restore report is sent

Restore report is sent &
the zone is ready to trip
again.

How does swinger
suppression affect it?

No affect

No affect

No affect


Condition?

Zone type BURG

Zone type 09
Fire

Zone type 14 Carbon
Monox
ide

Keypad Panics

When is restore report
sent?

When code is entered
or bell timeout if zone
is restored

When Code is
entered or bell
timeout if zone is
restored

After Code is
entered

When code is
entered or bell
timeout

When can you re
-
trip the
wired zone?

After bell timeout

After bell
timeout or
disarm

NA

Right Away

Affected by bell time
-
out?

Restore is sent at bell
timeout if zone is
restored.

Restore is sent at
bell
timeout if
zone is restored.

NO

No

When can you re
-
trip an
RF Zone?

When code + 1 is
entered

When Restored

Restore is not sent till
disarm, but zone will
trip again right away.

NA

What if bell time out is
set at zero?

Zone can not trip again

Zone can
not trip
again until
disarm

No affect

No affect

What if a code + off is
pressed and the zone is
NOT closed

Restore is sent

Restore
is sent

Restore report is sent

NA

What if a code + off is
pressed and the zone IS
closed?

Zone will be ready to
trip
again

Zone will be
ready to trip
again

Restore report is sent

NA

How does swinger
suppression affect it?

Zone will report one
more time after bell
timeout

No Affect

No affect

No Affect



'Disarm' can be
Arm then Disarm from touchpad
, code+1 twice on
prosixlcdkp, or press OFF button twice on
prosixfob



Day/Night Zone Type


Alarm (Night) follows BURG column,


Trouble (Day) is Latching. Trouble report is only sent once, Restore is sent when Trouble condition is cleared from
the console. Tro
uble on the zone will not report again until the previous condition is cleared.



Monitor ZT is True zone Restore reporting


Uploaded