System Sensor RRS-MOD - Data Sheet - Dated 08/2007



Related Products

System Sensor RRS-MOD - Reversing Polarity and Synchronization Module
System Sensor RRS-MOD
Reversing Polarity and Synchronization Module
List Price: $124.00
Our Price: $87.99

Document Transcript

Agency Listings
RRS-MOD
Reversing Relay/

Synchronization Module
The RRS-MOD reversing relay/synchronization module
enhances the operation of 2- and 4-wire i3

Series
detectors equipped with a sounder.
Features
Is compatible with 2- and 4-wire i3 detectors equipped with a

sounder
Activates all i3 sounders on a loop when one alarms

Synchronizes all i3 sounders on the loop for a clear alarm signal

Is usable with bell/alarm, alarm relay, or NAC outputs

Has a field-selectable switch to accommodate both coded and

continuous alarm signals
Allows i3 detector silencing from the panel or keypad

Operates on 12 and 24 volt systems

Simplifies connections with quick-connect harness and color-coded

wires
Installation ease.
The RRS-MOD reversing relay/synchronization
module includes a Velcro
®
attachment for easy installation into the
fire alarm control panel cabinet. A quick-connect harness and color-
coded wires simplify connections.
Intelligence.
The RRS-MOD module’s design is flexible to
accommodate virtually any application. It is compatible with both 2-
and 4-wire i3 Series detectors operating over 12 V and 24 V systems.
The module can be used with either bell/alarm, alarm relay, or NAC
outputs, and its field selectable switch accommodates both coded
and continuous alarm signals.
Instant inspection.
To meet fire alarm requirements, the RRS-MOD
reversing relay/synchronization module activates all i3 sounders on a
loop when an individual sounder alarms. Additionally, it synchronizes
the output of the i3 sounders, regardless of whether the panel’s alarm
signal is continuous or coded, to ensure a clear alarm signal.
S3705
3018895
7300-1653:165 3825 Ohio Avenue • St. Charles, IL 60174

Phone: 800-SENSOR2 • Fax: 630-377-6495
©2007 System Sensor.
Product specifications subject to change without notice. Visit systemsensor.com for
current product information, including the latest version of this data sheet.
A05-0350-001 • 8/07 • #1676
Wiring Diagrams
NOTE: These diagrams represent two common wiring methods. Refer to the RRS-MOD installation manual for additional wiring configurations.
Ordering Information
Part No.
Description
RRS-MOD
Reversing relay/synchronization module for i3 Series smoke detectors
RRS-MOD Specifications
Architectural/Engineering Specifications
Reversing relay/synchronization module shall be a System Sensor i3

Series
model
number
RRS-MOD,
listed
to Underwriters
Laboratories
as a smoke
detector
accessory. The module shall allow all 2-wire and 4-wire i3 Series detectors equipped with a sounder on a loop to sound when one alarms. The module shall
provide a switch to toggle between coded mode and continuous mode. When in coded mode, the module shall synchronize the i3 sounders on the loop to
mirror the input signal. When in continuous mode, the module shall synchronize the i3 sounders on the loop to the ANSI S3.41 temporal coded pattern. In either
coded or continuous modes, the RRS-MOD module shall permit sounders to be silenced at the panel. The RRS-MOD module shall operate between 8.5 and 35
VDC, and shall provide 18 AWG stranded, tinned conductors connected to a quick-connect harness.
Physical Specifications
Dimensions
2.5 in H × 2.5 in W × 1 in D (63 mm × 63 mm × 25 mm)
Operating Temperature Range
32°F to 131°F (0°C to 55°C)
Wire Connections
18 AWG stranded, tinned, 16 in length
Operating Humidity Range
5% to 85% non-condensing
Electrical Specifications
Operating Voltage
Nominal: 12/24 V
Min: 8.5 V
Max: 35 V
Average Operating Current:
25 mA
Relay Contact Rating
2 A @ 35 VDC
EOL
OPTIONAL
REMOTE
ANNUNCIATOR
(RA400Z)
OPTIONAL
REMOTE
ANNUNCIATOR
(RA400Z)
+

UL LISTED
ALARM
CONTROL
PANEL
2–WIRE
INITIATING
DEVICE
CIRCUIT
PURPLE
T+
+

+

AUX POWER
YELLOW
IN+
ORANGE
IN–
RED
PWR+
BLACK
PWR–
BROWN
OUT+
WHITE
OUT–
1 + IN
2 + OUT
3 - IN/OUT
4 RA+
5 RA-
1 + IN
2 + OUT
3 - IN/OUT
4 RA+
5 RA-
+

BELL/
ALARM
CIRCUIT
(positive signal
in alarm
state)
ALARM
RELAY
(NO Contact)
UL LISTED
ALARM
CONTROL
PANEL
2–WIRE
INITIATING
DEVICE
CIRCUIT
PURPLE
T+
+

+

AUX POWER
YELLOW
IN+
ORANGE
IN–
RED
PWR+
BLACK
PWR–
BROWN
OUT+
WHITE
OUT–
EOL
OPTIONAL
REMOTE
ANNUNCIATOR
(RA400Z)
OPTIONAL
REMOTE
ANNUNCIATOR
(RA400Z)
+

1 + IN
2 + OUT
3 - IN/OUT
4 RA+
5 RA-
1 + IN
2 + OUT
3 - IN/OUT
4 RA+
5 RA-
+

S0101-00
2-Wire System Triggered from Alarm/Bell Circuit
S0103-00
2-Wire System Triggered from Alarm Relay Contact


Uploaded