System Sensor RRS-MOD
Reversing Polarity and Synchronization Module
Description
The System Sensor RRS-MOD is a reversing polarity relay used to cause all two-wire or four-wire smoke detectors with sounders on a system to sound when a fire alarm is indicated. In addition to reversing polarity so that all of the smoke detectors sound, it also acts as a synchronization module, synchronizing the sounding of the fire alarm siren and the smoke detectors so that they all sound together.
Having all two or four-wire smoke detectors sound in the event of a fire alarm may be required by the building code in a particular area. It may be required by an insurance carrier, a fire marshall, or another AHJ (Agency Having Jurisdiction). It may also be that the homeowner or business owner simply wants them all to sound. Whatever the reason, the RRS-MOD is a popular way to achieve this goal.
The RRS-MOD is made by System Sensor to work with their i3™ two-wire and four-wire smoke detectors. Bear in mind, the RRS-MOD is only necessary when smokes with sounders are used. It helps to understand how System Sensor part numbers are chosen. For example, the System Sensor 2WTA-B is a two-wire (2W) with a thermal or heat detector( T) and an annunciator or sounder (A), and it is Normally Open, which means it is wired as a Class (B) circuit. So if you're shopping for smoke detectors, and you want a setup where smokes all over the premises sound, in addition to the RRS-MOD, be sure to choose smokes that have an annunciator, otherwise known as a sounder.
Connecting the RRS-MOD into your smoke detector circuit can be tricky for the DIY installer. We have a number of different documents to assist you in this. If you have a VISTA-20P, or a VISTA-21iPLTE you can use the following documents according to your application:
- Using the RRS-MOD with 2-wire i3™ Smokes on a VISTA-20P or VISTA-21iPLTE
- Using the RRS-MOD with 4-wire i3™ Smokes on a VISTA-20P or VISTA-21iPLTE
- Using the RRS-MOD with Multiple 4-wire Smoke zones with no EOLSR on a VISTA-20P or VISTA-21iPLTE*
- Using the RRS-MOD with Multiple 4-wire Smoke zones with an EOLSR on a VISTA-20P or VISTA21iPLTE
*When using 4-wire smokes, it is always recommended that you use an end-of-line-supervision-relay (EOLSR). This is so that if the 4-wire smoke zone loses power, the end-user will be notified immediately. Without the EOLSR, a loss of power to the 4-wire smoke detector zone may go unnoticed, putting lives at risk.
Specifications:
- Relay Contact Rating: 2 A @ 35VDC
- Average Operating Current: 25 mA
- Operating Voltage:
- Nominal: 12/24V
- Minimum: 8.5V
- Maximum: 35V
- Operating Humidity Range: 5% to 85% non-condensing
- Wire Harness Specifications: 18 AWG stranded, tinned, 16 inches in length
- Operating Temperature Range: 32°F - 131°F (0°C - 55°C)
- Dimensions: 2.5" H X 2.5" W X 1" D (63mm X 63mm X 25mm)
Brand: System Sensor