WST-600 Audio Smoke/CO Detector for DSC systems - Install Guide
Related Products
Related Categories
Document Transcript
TM
EC
-
FF
2
-
433
AUDIO
DETECTOR
US
P
atent
#
9,087,447
Installation
Manual & Users
Guide
SPECIFIC
A
TIONS
Frequency:
433.92
MHz
Operating
Temperature:
32°
-
120°F
(0°
-
49°C)
Battery:
One
3Vdc
lithium
CR123A
(1550
mAh)
Operating
Humidity:
5
-
95%
RH non
condensing
Battery
life:
5
years
Compatible
with
433MHz
DSC
Security Systems
Detection
distance:
6
in
max
Supervisory
signal
interval:
64
min(approx.)
OPER
A
TION
The
FireFighter
™
sensor
is
designed
to
listen
to
any
smoke
, carbon or combo
detector.
Once
confirmed
as
an
alarm,
it
will
transmit
a
signal
to
the alarm
control
panel
which
if
connected to a central monitoring
station,
will
dispatch
the
fire
department.
ENROLLING
Follow the instructions provided by your control panel, or wireless receiver
manual. The 6 digit serial number is p
rinted on
back of each device.
To
monitor smoke alarms
, w
hen prompted by the panel, enter the 6 digit serial number as printed on the dev
ice. Use either zone type 88 ( S
tandard 24
hour fire) or type 87 (Delayed 24 h
our fire). Remember to set the wireless bit (bit 8) for that zone attribute.
To monitor a
CO detector, take the printed serial number and replace the first digit with an 8. For example if the number printed is 436A4
8, you would
use
8
36A48 as the serial num
ber for the CO portion. Use zone type 81 (24 hour Carbo
n
Monoxide).
M
OUNTING
(
see
IMAGE:
2
)
Included
with
this
device
is
a mounting
bracket,
hardware
and
double
sided
tape.
To
ensure
proper
operation
ensure
the
side
of the
device
with
the
small
holes
is
directly
facing the
sounder
holes on the
smoke
detector.
Secure
the mounting
bracket
to the
wall
or ceiling using the
two
mounting screws
and
double
sided
tape
provided,
then
secure
the
audio
detector
to the mounting
bracket
using
the
small
screw
provid
ed.
The
FireFighter
™
must
be
mounting
within
6 inches
of
the
detector
for
optimal
operation.
***** It is possible that the sensor can hear other smoke detectors in close proximity so it is important to choose and to in
stall the sensor close to
a detector that is relatively isolated from other detector. It that is not possible, the sensor will stil
l function it will however take longer to register
and transmit to the panel. Smoke detector
s
to avoid are typically ones mounted in hallways outside of bedroom
s
that will also have additional
smoke detectors
.
WARNING:
Non
-
interconnected
smoke
detectors
require
an
audio
detector
by
each
smoke
detector
sounder.
This equipment should be installed in accordance with Chapter 2 of the National Fire Alarm Code, ANSI/NFPA 72, (National Fire
Protection
Association, Batterymarch Park, Quincy
, MA 02269). Printed information describing proper installation, operation, testing, maintenance,
evacuation planning, and repair service is to be provided with this equipment. Warning: Owner’s instruction notice: ’Not to b
e removed by
anyone except occupa
nt’.
TESTING
(
see
IMAGE:
1
)
To
test the RF transmission
from
the mounted
position
you
can
either generate
a tamper
by
removing
the cover or
press
the
learn
button
located
next to the tamper switch
.
Press and release ONCE to send a Smoke signal or press and HOLD for 2 seconds to send a Carbon signal.
Within the first hour of power up the sensor is in a test mode. This mode is designed to work with the test button of the smo
ke detector so that
only 1 or 2 temporal patterns is required to trigger the sensor. After the 1 hour has elapsed the sensor will r
equire at least 3 rounds of either
temporal 3 (smoke) or temporal 4 (CO) before it will send a transmission to the control panel. . Ensure the FireFighter™ cove
r is on and that you
wear hearing protection when doing the audio testing. Then simply
press
and
hold the
smoke
detector
test
button.
If 24 Hr, delay fire zone type is used the alarm must be active for 30 second before the panel will transmit to the Central S
tation.
NOTE:
This system must be checked by a qualified technician at least once
every three (3) years.
Please test the unit once per week to ensure proper
functionality.
Legacy Smoke Detectors
All Smoke detector should be replaced after 10 year. If you encounter a smoke detector that does not support Temporal 3 patte
rn, that smoke
should be replaced as per the manufacturer recommendation.
If replacement is not an option the FireFighter can be program to detect non
-
temporal detectors
.
**
In this mode, the sensor must not be located near any other audible device, like the security ke
yp
ad or sounder. Those can b
e misconstrued
as a valid smoke alarm.
To enter this mode press and hold the tamper button while inserting the battery. Release the tamper switch and note
the LED
ONE flash:
Only a
Temporal
3 and 4
signal will trigger an alarm
(Default)
TWO flashes: Generic listening mode.
(Will trigger after 30 seconds
of continuous
sound)
You can
verify the
mode
the device is in
by simply removing
the
battery and replacing it. The LED will fl
ash once or twice dep
ending on the
mode it is
in
.
Repeat the steps above to change the mode as required.
REPLACING THE BATTERY
When the battery is low a signal will be sent to the control panel. To replace the battery:
1.
Remove the top cover to reveal the battery. This will send a tamper signal to
the control panel.
2.
Replace with a Panasonic CR123A battery ensuring the + side of the battery faces as indicated on the device.
3.
Re
-
attach the cover, you should hear a click when the cover engages properly.
WARNING:
While the
audio
detector
monitors
its
own
battery,
it
does
not monitor the
battery
in
the
smoke
detectors.
Batteries
should
be
changed
as
per
the original
smoke
detector
manufacturer’s
instructions.
Always
test the
audio
detector
and
smoke
alarms
after
battery
installation
to confirm
proper
operation
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FC
C Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. Thi
s equipment generates uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. How
ever, there is no guarantee that
interference will not oc
cur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which c
an be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of t
he following measures:
•
Re
-
orient or relocate the receiving antenna
•
Increase the separation between the equipment and receiver
•
Connect the equipment to an outlet on a different circuit from the receiver
•
Consult the dealer or an experienced radio/TV
contractor for help.
WARNING: Changes or modifications not expressly approved by Encore Controls could void the user’s authority to operate the eq
uipment.
This device complies with Industry Canada license
-
exempt RSS standard(s). Operation is subject to t
he following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of
the device.
FCC ID:
2ACQ8
-
ECFF433
IC:11455A
-
ECFF
433
WARRANTY
Encore
Controls warrants that for a period of 2 years from the date of purchase that this product is free from defects in material
and workmanship. This warranty
does not apply to damage caused by shipping or handling, or damage caused by accident, abuse, misuse
, misapplication, ordinary wear, improper maintenance,
failure to follow instructions or as a result of any unauthorized modifications. If there is a defect in materials and workma
nship under normal use within the warranty
period Encore Controls shall, a
t its option, repair or replace the defective equipment upon return of the equipment to the original point of purchase. The f
oregoing
warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expr
essed
or implied and of all other obligations or liabilities on the part of Encore Controls neither assumes responsibility for, n
or authorizes any other person purporting to
act on its behalf to modify or to change this warranty, nor to assume for it any
other warranty or liability concerning this product. The maximum liability for Encore
Controls under all circumstances for any warranty issue shall be limited to a replacement of the defective product. It is r
ecommended that the customer check their
equ
ipment on a regular basis for proper operation.
THE LIABILITY OF ENCORE CONTROLS , OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM
DETECTOR OR
UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED
THE COST OF REPLACEMENT OF A SMOKE ALARM DETECTOR AND, IN NO CASE,
SHALL ENCORE CONTROLS , OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS BE LIABLE FOR CONSEQUENTIAL LOSSES OR DAMAGES RESULT
ING FROM THE
FAILURE OF THE SMOKE ALARM DETECTOR OR FOR BREACH
OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY
THE COMPANY’S NEGLIGENCE OR FAULT.
The Firefighter™ detector does not detect the presence of smoke, heat, or fire directly. It relies solely on the presence of
an au
dio alarm signal generated by an
existing smoke or fire detector in proximity to the Firefighter™ detector to make such a determination. The Firefighter™ dete
ctor must be used with smoke detectors
certified according to UL Standards, and in strict accordan
ce with the installation and operation instructions provided with such detectors. It is the owner’s
responsibility to ensure that smoke or fire detectors used in conjunction with the Firefighter™ detector are maintained and t
ested on a regular basis in acc
ordance
with the manufacturer’s instructions. Encore Controls expressly disclaims any responsibility for the failure of the Firefigh
ter™ detector to detect the presence of
smoke or fire due to the failure of any smoke or fire detector used in conjunction
with the Firefighter™ detector to operate properly due to any condition, including
improper installation, operation, maintenance or testing of such smoke or fire detector
.
LEARN BUTTON
TAMPER SWITCH
Encore Controls Inc.
2140 Hall Johnson Rd.
Ste 102
-
157
Grapevine, TX 76051
855
-
797
-
2977
PN EC
-
FF
2
-
433 R1.00
REV DATE:
1
/27/1
6
IMAGE
1
:
ENROLLING
/
TEST
/
TAMPER
BUTTON
IMAGE
2
:
INSTALLATION
DISTANCE
6
”
MAX