Wired Alarm Control Panels Frequently Asked Questions

How Do I Program My Honeywell VISTA 15P?
When programming a VISTA 15P, you must first access system programming. Next, you will access the programming field that you want to adjust. From there, enter in the appropriate data. Finally, you will exit system programming to save your changes. Learn more about programming a VISTA 15P.
Added:

How Do I Program a Wired Zone on a Vista Panel?
Determine how you wish to connect your wired zone, then program each zone according to the way it is wired. Zone 1 must always be wired with a 2K end or line resistor. Zones 2 - 6 (15P) or 2 - 8 (20P, 21iP) can be programmed as Normally Open, Normally Closed, or EOL. Read on to learn more. Determine how you wish to connect your wired zone, then program each zone according to the way it is wired. Zone 1 must always be wired with a 2K end of line resistor. Zones 2 - 6 (15P) or 2 - 8 (20P, 21iP) can be programmed as Normally Open, Normally Closed, or EOL. Read on to learn more.
Added:

How Do I Wire a 2-Wire Smoke Detector to My Wired Alarm System?
A 2-wire smoke detector connects directly to a hard-wired zone on a wired alarm system. Learn how to interface a 2-wire smoke with your wired alarm system.
Added:

How Many Zones Can a 5881 Medium Board Handle?
The Honeywell 5881ENM medium wireless receiver provides support for up to 16 wireless zones, and it is compatible with all Honeywell Vista control panels.
Added:

What is Zone-Doubling on a Honeywell VISTA System?
Zone-doubling is a method of using different value resistors on zones 2 - 8 to allow 7 hardwired zone inputs to behave like 14 separate zones. This is particularly helpful if you need more than 8 hardwired zones, but fewer than 16. Zone 2, doubled, becomes 2 and 10, zone 3 becomes 3 and 11, and so on.
Added:

Why Isn't My Wired Door Sensor Working?
A wired door sensor may not be showing the correct status due to programming or wiring issues. Read on to find out how to troubleshoot wired door sensors.
Added:

How Do I Wire an IS3035 Motion to My Security System?
The Honeywell IS3035 is connected to a security system via an 18 to 22 gauge wire. The wire runs from the panel into the motion detector's terminal block.
Added:

How Do I Reset the Polling Loop Smoke Detector on a VISTA 128BPT?
The 5193SD and 5193SDT smoke detectors do not contain sounders. Because of this, a reset is not required after a fire alarm occurs on the Vista 128BPT.
Added:

What is the Difference Between a Master Code and a Normal User Code?
A master code has the ability to add, edit, and delete other user codes. It can never deleted, only edited. A user code can only arm, disarm, and bypass.
Added:

How Do I Enter Walk Test Mode on a Vista Panel?
You can enter walk test mode on the Vista-15P, 20P, 21iP panels by keying in Installer Code + [5] + [0]. The panel must be "Ready" to access test mode.
Added: