Wired Motion Detecting Sensors Frequently Asked Questions

What is Zone-Doubling on a Honeywell VISTA System?
Zone-doubling is a method of using different value resistors on zones 2 - 8 to allow 7 hardwired zone inputs to behave like 14 separate zones. This is particularly helpful if you need more than 8 hardwired zones, but fewer than 16. Zone 2, doubled, becomes 2 and 10, zone 3 becomes 3 and 11, and so on.
Added:

How Do I Wire an IS3035 Motion to My Security System?
The Honeywell IS3035 is connected to a security system via an 18 to 22 gauge wire. The wire runs from the panel into the motion detector's terminal block.
Added:

Honeywell IS-3035 vs DT8035 Motion Detector?
The difference between the IS-3035 motion and the DT-8035 motion is that the DT-8035 uses PIR and microwave to detect motion. Learn about the two devices.
Added:

What's the wire length limit on a Honeywell VISTA's polling loop?
There are strict limits on polling loop distance, based on current drawn, and wire gauge used. Learn the rules and limits for wiring the polling loop.
Added:

What's the wire length limit on a Honeywell VISTA's polling loop?
There are strict limits on polling loop distance, based on current drawn, and wire gauge used. Learn the rules and limits for wiring the polling loop.
Added:

How Do I Connect a 4193SN to a VISTA-128BPT, 250BPT or VISTA-50?
The 4193SN connects to the Vista-128BPT, 250BPT, or 50 through the polling loop on terminals 24 (Positive) and 25 (Negative). Learn how to wire the 4193SN.
Added:

How Do I Add a 4193SN to My VISTA-128BPT, 250BPT or VISTA-50?
The 4193SN is an expansion device which allows users to add conventional devices to the polling loop by programming its serial number into the zone(s). Read on.
Added:

How Do I Program a 4193SN to a VISTA-128BPT, 250BPT, or VISTA-50?
The Vista-128BPT and similar panels use a polling loop for wired expansion. In zone programming, use input type to identify zones. Learn to program a 4193SN.
Added:

Will Curtain Movement Set off Infrared Motion Sensors?
Moving but otherwise inanimate objects, like curtains, in an empty room can activate an infrared motion sensor, causing a false alarm. Read on to find out why.
Added:

Should I Use Resistors on my VISTA 21iP?
When using hardwired zones, it is more secure and tamper proof to use End of Line Resistors to supervise zone wiring. Find out the pros and cons here.
Added: