Is Telguard Interactive Used On Honeywell Vista Panels?

TelguardTelguard Interactive provides the ability to remotely arm or disarm your system, view arming and alerting history and receive notifications of any alarm status change, easily and securely.

Follow the following instructions to set up a TelGuard Interactive on a Vista-P control panel.

On the keypad enter 4112 followed by 800 to enter programming.

Press *56 zone programming mode. Display will show Set To Confirm - enter the star (*) key to get to the zone area.

Display will show Enter Zone Number - enter XX* on keypad, XX=zone number

Display will show ZN (0X), ZT (00), P (1), RC (00) HW:RT (EL:1), enter the star (*) key on the keypad, this will advance to enter zone type.

Display will show ZN T, enter 77 star (*) on the keypad, this will configure zone type for keyswitch.

Display will read ZN (0X), ZT (77), P (1), RC (00), HW:RT (EL:1)

Enter star (*) 00 on keypad to get out of programming.

To program the Output:

Enter star (*) 80 on keypad, this will advance to output programming mode.

Display will show Output Funct #, enter 01 star (*) on the keypad

Display will show 01(?00), A (0), E(0), P (-), TRIG (ZN=00)

Enter star (*) on the keypad, display will show Activate output by zone type.

Display will show, 01 Activated by zone type, enter 2 star (*) on the keypad.

Display will show 01 Enter Zn Type Keysw XX, enter star (*) 78 on the keypad, (Zone type - xx, 78=keyswitch,Red LED, 79=keyswitch Green LED).

Keypad will display 01 partition (x) enter 1 star (*) on keypad, type in partition.

Keypad display will show Enter Output No. (Txx) (x), enter 18 star (*) on keypad (output 17 and 18 are the only choices).

Keypad display will show 01 A E P TRIG (T18 - - 1 ZT=18), enter star (*) on the keypad.

Keypad will display, Output Funct #, enter 00 on keypad to exit the output programming menu.

To enable open/close reports, enter star (*) 65 on the keypad, this will advance to Open Report Code.

Keypad will display Open Report 1 2 3, enter 1 1 1 on keypad

Keypad will display Awy/Sty RP 123, enter star (*) 66 on keypad

Keypad will display Awy/Sty RP 123, enter 111111 on keypad

Enter star (*) 99 on keypad - exit commands

Keypad display will show Enter * or #, enter star (*) 84 on keypad - away stay arm

Keypad will display Auto Sty Opt, enter 0 on the keypad, NO

Enter star *99 on the keypad to exit programming mode



Did you find this answer useful?

We offer alarm monitoring as low as $10 / month

Click Here to Learn More

Related Products

Telular TG-1 Express - 3G Universal Cellular Alarm Communicator
Telguard TG-1 Express
AT&T 3G Universal Cellular Alarm Communicator
Taxons
Telguard TG-1B
AT&T LTE Universal Cellular Alarm Communicator

Related Categories


Answered
Answered By