How Do I Factory Reset Alarm.com Compatible Cameras?
You can factory reset an Alarm.com compatible camera by following the specific factory reset process for that camera. Each ADC camera follows a slightly different process. Most ADC cameras can be factory reset by pressing and holding the device's reset button for a specific period of time.
After the factory reset process for the camera is complete, the device should remain plugged-in and left alone for at least two (2) minutes. The device will then be factory reset. Remember, you can always check the instruction manual for the device for more information.
Before performing any factory reset on any Alarm.com Camera, you should wait at least two (2) minutes after the device has been powered on. Attempting to perform a factory reset before the camera has fully powered on could cause the reset to fail, and you would have to do it over.
Please note that factory resetting an Alarm.com Camera will NOT delete it from an account. You will still need to remove/delete the camera from the existing account before you will be able to add it to a new one. This is very important if you ever decide to try and buy a used Alarm.com Camera. Always make sure a used Alarm.com Camera is deleted from the old account before purchasing!
The factory reset processes for most ADC cameras are outlined below. For cameras not included on this list, a reset is typically performed by pressing and holding the reset button for 15 seconds to 60 seconds depending on the camera model. Giving that a try for unlisted cameras will usually work. You can also refer to the camera's instruction manual for more information.
ADC-V700X: Press and hold the reset button inside the back of the camera until the LED light on the device rapidly flashes red. This will take about 90 seconds.
ADC-V510: Press and hold the reset button on the device until its LED light rapidly flashes red. This will take about 60 seconds. You will need a paperclip to press and hold the reset button.
ADC-V610PT: Press and hold the reset button on the device until its LED light rapidly flashes red. This will take about 60 seconds. You will need a paperclip to press and hold the reset button. The reset button can be found underneath the camera.
ADC-VS1: Press and hold the reset button on the device until its LED light rapidly flashes red. This will take about 60 seconds. You will need a paperclip to press and hold the reset button.
2GIG CAM-HD100: Press and hold the reset button on the device until its LED light rapidly flashes yellow. This will take about 10 seconds.
ADC-VS120: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds. You will need a paperclip to press and hold the reset button.
ADC-VS420: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds. You will need a paperclip to press and hold the reset button.
ADC-V520: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds. You will need a paperclip to press and hold the reset button.
ADC-V521IR: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 10 to 15 seconds. The reset button is found on the back of the camera.
ADC-V522IR: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 10 to 15 seconds. The reset button is the same as the WPS button, and it is found on the back of the camera.
ADC-V523: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds. The reset button is the same as the WPS button, and it is found on the camera's underside.
ADC-V620PT: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds. You will need a paperclip to press and hold the reset button.
ADC-V622-WELL: Press the Menu button, and then use the Volume buttons to locate the Factory Reset option. Select this option, and follow the audio prompts to perform the reset.
ADC-V720: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds.
ADC-V720W: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds. The reset button is the same as the WPS button.
ADC-V721W: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds. The reset button is the same as the WPS button.
ADC-V722W: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds. The reset button is the same as the WPS button.
ADC-V723: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds. The reset button is the same as the WPS button, and it is found on the camera's underside.
ADC-VC725: Power down the camera by disconnecting its power supply. Use a paperclip or a similar thin object to press and hold the reset button while simultaneously powering on the camera. The reset button will make a small clicking noise when pressed so that you know it is being held down. Continue to hold the reset button for at least ten (10) seconds to ensure that the reset goes through successfully.
ADC-VC726: Power down the camera by disconnecting its power supply. Use the included hex key for the camera to remove the water-tight door for the camera at its bottom. Press and hold the reset button found underneath the door while simultaneously powering on the camera. Continue to hold the reset button for at least ten (10) seconds to ensure that the reset goes through successfully.
ADC-VC736: Power down the camera by disconnecting its power supply. Remove the water-tight door for the camera using a Phillips head screwdriver. Press and hold the reset button found underneath the door while simultaneously powering on the camera. Continue to hold the reset button for at least ten (10) seconds to ensure that the reset goes through successfully.
ADC-V820: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds. The black reset button is inside the camera on the back.
ADC-V821: Press and hold the reset button on the device until the LED lights blink red. This will take about six (6) seconds. The reset button is found on the main circuit board inside the camera.
ADC-VC825: Power down the camera by disconnecting its power supply. Unscrew the camera cover and remove it. Press ad hold the reset button underneath the cover while simultaneously powering on the camera. Continue to hold the reset button for at least ten (10) seconds to ensure that the reset goes through successfully.
ADC-VC826: Power down the camera by disconnecting its power supply. Unscrew the camera cover and remove it. Press ad hold the reset button underneath the cover while simultaneously powering on the camera. Continue to hold the reset button for at least ten (10) seconds to ensure that the reset goes through successfully.
ADC-VC836: Power down the camera by disconnecting its power supply. Remove the water-tight door for the camera using a Phillips head screwdriver. Press and hold the reset button found underneath the door while simultaneously powering on the camera. Continue to hold the reset button for at least ten (10) seconds to ensure that the reset goes through successfully.
ADC-SVR100: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds. You will need a paperclip to press and hold the reset button.
ADC-SVR122: Press and hold the reset button on the device until its LED light rapidly flashes red and green. This will take about 15 seconds. You will need a paperclip to press and hold the reset button.
ADC-CSVR126: Access the local interface for the device. Click the menu icon, which is the three (3) horizontal bars. Choose System, followed by Factory Reset. You may need to provide the password for the device. Click Next to proceed with the reset. The device must be re-enrolled with with an Alarm.com account following a factory reset.
Alarm.com SkyBell: Press and hold the main SkyBell button until the button begins flashing blue. This will take about 50 seconds.