What is an 803 Signal on a VISTA Panel?
Zone 803 is used by default for AlarmNet devices to report their own trouble conditions. On Vista-128/250 panels, zones in the 800 range supervise keypad bus devices. The radio, by default, is set to address 03, hence 803. This makes AlarmNet issues easily distinguishable from other issues.
Communicator issues reported by the panel will follow reporting logic for that panel, and may indicate a different zone number. For example, on a Vista-20P, an issue reported by an AlarmNet Communicator for itself may report as Zone 803, while the same issue reported by the alarm panel, may report as Zone 103. You can see an example of this in the chart below:
Alarm Condition | ECP Mode | |
Alarm Code | Restore Code | |
Power on / Reset | E339 C08xx* | |
Tamper | E341 C08xx* | R341 C08xx* |
Power Loss | E337 C08xx* | R337 C08xx* |
Low Battery | E338 C08xx* | R338 C08xx* |
Battery Charger Fail | E314 C08xx* | R314 C08xx* |
ECP Supervision | E355 C0000 | R355 C0000 |
Primary Comm Path Supervision | E350 C0951 | R350 C0951 |
Secondary Comm Path Supervision | E351 C0952 | R350 C0952 |
Periodic GSM Comm Test Failure | E358 C0803 | |
Test | 5555 5555 9 | |
The following signals are specific to Vista-10P, 15P, 20P, and 21iP Series panels. Zone 803 indicates a report sent by the communicator, zone 103 indicates a report sent by the alarm panel | ||
Communicator Trouble (low battery, ECP issue, Network issue) | E353 C08xx*♦ | R353 C08xx*‡ |
Radio Fault | E353 0 103 ‡ | R353 0 103 ‡ |
The following signals are specific to Commercial Control Panels (Such as the Vista-128/250 Series) | ||
Communicator Trouble (low battery, ECP issue, Network issue) | E333 C08xx*‡ | R333 C08xx*‡ |
Radio Loss of Signal | E357 0 8xx*‡ | R357 0 8xx* ‡ or R380 0 8xx* ‡ |
Radio Fault (low battery, tamper, ECP bus) | E333 0 8xx* ‡ | R333 0 8xx* ‡ |
AlarmNet Messages | ||
Communication Failure | E359 00 950 | |
Communication Failure Reminder (Previously reported, unrestored) | P359 00 950 | |
Communication Faillure Restoral | R359 00 950 | |
New Registration | E360 00 000 | |
Authorized Substitution Registration | E361 00 000 | |
Unauthorized Substitution Registration | E362 00 000 | |
* xx = Communicator Device Address ‡ = Message is sent by dialer and radio ♦ = Message is sent by dialer only, or dialer and radio, depending on the failure |
Did you find this answer useful?
We offer alarm monitoring as low as $10 / month
Click Here to Learn MoreRelated Products
Honeywell VISTA-21iP
Internet Alarm Control Panel
Honeywell VISTA-21iPSIA
Internet Alarm Control Panel
Related Categories
- Wired Alarm Control Panels
- Internet Security Systems
- Cellular Security Systems
- Cellular Alarm Communicators
- Internet Alarm Communicators
- Answered
- Answered By
- Julia Ross