STEPS TO DEFAULT SiX
and PROS
i
X
SERIES
DEVICES
Defaulting a device may be necessary
if the
device is
enroll
ed
in
a panel
(paired with a panel)
in a
location that is different than the
intended
panel
,
and the installer does not have access to the
unintended
panel to delete the sensor.
Each device
provides
visual indicat
ion
showing whether or not
it is paired with a controller. This is
described in the table below
for each device
.
The procedure to default each device is primarily the same
(except
for
the keypad and key fob)
: Open
the device cover, remove the battery, activate the tamper switch, a
nd then reinstall the battery while
the tamper switch is still held down.
For devices other than the SiXFOB
/PROSIXFOB
, t
his process is available for 24 hours after enrollment
with the panel and while the
device remains powered
(battery installed
in sensors; AC power applied at
keypad)
.
For the SixFOB
/PROSIXFOB
, this process expires after the first 100 transmissions.
PROCEDURES
MODEL
DEFAULT PROCEDURE
PAIRED/NOT PAIRED INDICATION
SiXCT
SiXMINICT
SiXGB
PROSIXMINI
PROSIXMINI2
PROSIXGB
PROSIXCT
PROSIXFLOOD
PROSIXSHOCK
PROSIXTEMP
1.
M
ake sure the transmitter is on the base
mount
ing
bracket. Remove the Cover and
battery.
2.
Press and hold the tamper switch,
Install the battery and continue to hold
the tamper
switch.
3.
After a couple of seconds LED will flash
rapidly
Indicator
Paired
Not Paired
Green LED
slow blink
when tamper
faulted
fast
blinking
when
tamper
faulted
SiXSIREN
SiXSIRENOD
PROSIXSIREN
PROSIXSIRENO
1.
Remove the Baseplate.
2.
Remove the
batteries.
3.
Hold the tamper switch down.
4.
Reinstall the batteries while still holding
the tamper switch
down
(recommended
15
-
30 sec)
.
Indicator
Paired
Not Paired
Green LED
slow blink
when tamper
faulted
fast
blinking
when
tamper
faulted
SiXSMOKE
SIXSMOKE
-
CN
1.
Remove
the
baseplate.
2.
Remove the batteries.
3.
Activate the tamper with a magnet.
4.
Reinstall the batteries while still
activating the tamper switch.
Indicator
Paired
Not Paired
Green LED
slow blink
when tamper
faulted
fast
blinking
when
tamper
faulted
SiXPIR
PROSIXPIR
1.
Open the cover.
2.
Remove the battery.
3.
Hold the tamper switch down.
4.
Reinstall the battery while still holding
the tamper switch down.
Indicator
Paired
Not Paired
Green LED
slow blink
when tamper
faulted
fast
blinking
when
tamper
faulted
LKP500
-
EN
LKP500
-
ENC
(
LYRIC
KEYPAD)
1.
Press the 3 key until the advanced
menu is displayed
2.
Scroll until
“
Default
”
is displayed.
3.
Press select.
Indicator
Paired
Not Paired
Status icon
slow blink
fast
blinking
SiXFOB
PROSIXFOB
1.
Press and hold the three white buttons
simultaneously for
more than five (5)
seconds.
This process is available for the
first 100 transmissions from the key fob.
Indicator
Paired
Not
Paired
both
LEDs
LEDs no
t
blinking
when
both top
buttons are
pressed
alternating,
fast
blinking
when both
top buttons
are pressed
PROSIXLCDKP
1.
Press and hold the [3] key until
"Programming Mode” is displayed
2.
Press the Scroll [3] key to
scroll to
Default Keypad, press 2 to Confirm or *
to abort
.
Indicator
Paired
Not Paired
Status icon
and trouble
led
System status
is displayed
Alternate
blinking
,
display will
show
"press any
key to pair
with
system
PROSIXRPTR
1.
Open the cover
and verify device is
powered on
.
2
.
Hold the tamper switch
for ½ seconds
and repeat four times (for a total of
five)
.
4.
All three LEDS rapidly flash leaving only
the Power LED on
.
Indicator
Paired
Not Paired
All 3
LEDs
Green
LEDs no
t
blinking
Only
the
Power LED
is on
and
all scroll
when
tampered
PROSIXHEATV
PROSIXSMOKEV
1.
Remove the Detector from the
Base and remove the Batteries
.
2.
Flip the Tamper switch to the 'non
tampered' position.
3.
Install the batteries.
4.
Watch the green LED for a rapid
flash.
5.
Remove the batteries and set the
tamper switch back to the
'Tampered' position
.
Indicator
Paired
Not Paired
Green LED
Slow blink
when
tampered
Fast
blinking
when
tampered
PROSIXC2W
1.
Open the cover
and verify device is
powered on
.
2
.
Simultaneously press and release the
calibration and tamper switches.
4.
The Green enrollment LED rapidly
flashes and the PROSIXC2W defaults
.
Indicator
Paired
Not Paired
LED
#1
Slow blink
when
tampered
Fast
blinking
when
tampered
PROSIXCOMBO
PROSIXCOMBOC
SIXCOMBO
SIXCOMBO
-
CN
1. Press and hold both the Smoke and CO
test switches simultaneously until the
welcome message announces, then
release.
2. Wait for green LED to flash rapid
l
y.
3. Press and hold
both switches again for
one second and release.
4. LED blinks rapidly for 15 seconds.
OR
1.
Remove
the
base Plate and
Remove
the batteries.
3.
Activate the tamper with a magnet.
4.Reinstall the batteries while still
activating the tamper switch.
Indicator
Paired
Not Paired
Green LED
Slow blink
when
tampered
Fast
blinking
when
tampered
PROSIXCO
PROSIXCOCN
1. Remove batteries from the detector
2. Press the CO Test Button.
3. While holding the
CO
test button, insert
the batteries.
Continue hold the test
button for 5 seconds and release.
4. The status LED should start blinking
green rapidly.
Indicator
Paired
Not Paired
Green LED
Slow blink
when
tampered
Fast
blinking
when
tampered
P
ROSIXMED
1.
Press and hold button for 15
seconds.
When successful, the LED comes back on
flashing.
Indicator
Paired
Not Paired
Green LED
Fast blinking
for 2 seconds
when pressed
for 2 seconds
Fast
blinking for
20 seconds
when
pressed for
2 seconds
PROSIXPANIC
1.
Press and hold
BOTH
button
s
for 15
seconds. When successful, the LED comes
back on flashing.
Indicator
Paired
Not Paired
Green LED
Fast blinking
for 2 seconds
when pressed
for 2 seconds
Fast
blinking for
20 seconds
when
pressed for
2 seconds
PROWLTOUCH
PROINDMV
These devices are
not SiXRF device
s
that lock to a Panel.
They
can be
paired to a different control panel
without
be
ing
delet
ed
from the current
control panel.
They do not have a
default option
- Uploaded