March 2020 Archives

Posted By

For a security system owner, remembering to properly arm the system before leaving can be a tough task. It's one of those little things that's easy forget. You forget to grab your your car keys. You leave a door unlocked. You accidentally leave the lights on overnight. These things happen.

Honeywell lyric controller encrypted wireless security system

Another concern we often hear from customers is whether or not they really need to arm their systems if they are just stepping outside for a minute. Maybe they're just taking their dog around the block, or visiting a neighbor across the street, or walking over to a nearby convenience store. They will only be gone for a minute or two. Is it okay to leave the system disarmed in these situations?

Obviously, if you leave your system disarmed while you are away and an intruder decides to make a quick break-in, there is little that can be done. Security cameras can capture the event happening, but they aren't going to trigger an emergency response if your system is disarmed. If your system isn't ready to trigger an alarm, and you aren't around to stop an intruder, then there is very little that can be done.

With that in mind, we at Alarm Grid recommend that you always arm your system before heading out, even if it's only going to be for a brief moment. You invest into your security system for a reason. Don't let it go to waste. Protect your belongings and your property. Take the extra second or two and arm your system.

Of course, that is just our advice to you as a monitoring company. We totally understand that some users are going that have that "ah, I'll only be gone a second" mentality. And that's up to you. As an end user, you are in complete control, and if you are comfortable leaving your system disarmed when stepping out for a brief moment, then that is up to you. Just understand that we are not liable if you forget or decide not to arm your home alarm system.

One thing you might do is consider your own personal situation. Maybe it's okay to leave your system disarmed if you're just over at the neighbors, and you can visibly see your house? Maybe you can bring your Android or iOS Phone with you and arm using Total Connect 2.0 or Alarm.com if it turns out you're going to be away longer than you thought? Maybe your can add a key fob to your system to make it easier to quickly arm when walking out the door, instead of needing to enter a code or pull up a mobile app.

Ultimately, how you use your system is up to you. We recommend always arming, even if you're only going to be gone for a little bit. It's not worth the risk to your property, and securely arming/disarming your system can be such a quick and easy task if you add the right equipment. Nearly every alarm panel can be set up with some type of one-touch arming and disarming function to make the process as simple as possible.

We also understand that some users might have the intention of always arming, but they simply forget to do so. We have some tips for these users as well. You might have a secondary keypad right by the door that you will always see when walking out. That way, you will always remember to arm your system. If you don't want to add a new keypad, you could just put a sticky note on the door to remind you. And if your system is monitored, then you can set up geofencing arming reminders through an interactive service like Total Connect 2.0 or Alarm.com. There are many options available.

Remember that many wireless security systems today also often serve as automation controllers. This way, you can use an app on your phone to control the various devices around your home from anywhere. If you forget to turn off your lights, leave your thermostat running, or leave your door unlocked, then you can control the affected device while you are away. This is great for anyone who might be a little absentminded from time to time! Plus, it's good to know that you can always lock/unlock your door or turn your lights ON or OFF if needed. You just need the proper equipment.

Our job is to provide you with reliable monitoring service and the equipment you need to stay protected and secure. You just need to make sure you arm your system when leaving your home. If you need any more tips for remembering to arm your system, or if you want to learn more about any of our products or services that may make it easier for your to use your system, just reach out to us by emailing support@alarmgrid.com. We operate support hours from 9am to 8pm ET M-F, and we are happy to help you out. We look forward to hearing from you!

Tags: , , , , , , , , , , ,

Comments


Posted By

Firmware Version 2.5.0 for the Qolsys IQ Panel 2 Plus is now officially available and can be downloaded to any original IQ Panel 2 or IQ Panel 2 Plus. The update provides some new and exciting capabilities for the system. It is advised that anyone with a compatible IQ2 System updates ASAP.

Qolsys iq panel 2 plus verizon lte with powerg s line and legacy

Before we talk about the new features that come with Software Version 2.5.0, let's first discuss how to update the software on the panel. The IQ Panel 2 or IQ Panel 2 Plus System must be already running at least Firmware Version 2.0.1. The panel must be connected to a local WIFI network. Its transformer should be plugged in, and its backup battery should be charged. Once those conditions are met, you can begin the upgrading process.

Start from the main screen of the system. Click the small grey bar at the top of the screen. Select Settings > Advanced Settings > enter the Installer Code (default is 1111) > Upgrade Software > Patch Tag > enter iqpanel2.5.0 > OK > Upgrade Using Network. If done correctly, the upgrading process should begin. The process will take around (15) minutes. Please note that you must enter iqpanel2.5.0 exactly as the Patch Tag. If you enter the Patch Tag differently, then the process will not work correctly. If you do not have access to a WIFI connection, the firmware update files can be downloaded from our site.

As for the 2.5.0 Firmware itself, the following new features and changes have been made:

  • New Sensor Group 25 - Non Reporting. Used with Environmental Sensors (Flood, Freeze, Temperature). Will not report to central station, but will report to Alarm.com Fixes previous issue of temperature sensors being unable to send notifications to users through Alarm.com.
  • New Sensor Group 53 - Temperature Reporting. Used with Temperature Sensors for reporting to a central station.
  • Added support for sump pump integration through Alarm.com if Water Management Add-On Package is applied to the account.
  • Can now delete failed Z-Wave nodes from Alarm.com.
  • Added software and settings that support European CE & EN Grade 2 Certification.
  • New Languages: Dutch, Italian, Icelandic, Norwegian, Swedish.
  • Sensor name length limit increased from 24 characters to 56 characters.
  • Can now set Photo Frame Start Time to begin after One (1) Minute of inactivity.
  • Panel overheat notification can now be sent to Alarm.com.
  • New quick names for motion detection sensors available.
  • Disabling the Panel Camera Setting now also disables Panel Camera from the Equipment List and from the Alarm.com back-end and mobile app.
  • Master Code can now make language changes.
  • Minor translation updates for Spanish and French (Canadian).
  • Added access to Tutorial Help Videos on the last page of the Easy Install Wizard.
  • Enhanced weather icon mapping between the system and Alarm.com.
  • Corrected constant chime issue for Qolsys IQ Remote Keypad.
  • IQ Remote will now make severe weather alert annunciations (if enabled on main panel).
  • Corrected issue where IQ Remote could become stuck in Network Reconnection.
  • Improved communication reliability between system and IQ Remote.
  • Photo frame images can now be sent from system to IQ Remote.
  • New ability to record duress alarm videos using IQ Remote built-in camera.
  • Can enable/disable Disarm Photos for IQ Remote.
  • Live-stream cameras can now be full screen on IQ Remote.
  • Alarm image upload to primary panel has been improved.
  • Check-In & Check-Out Photos for Alarm.com Wellness can be sent to Alarm.com when Image-Plus Add-On Package is applied to the account.
  • Wellness alarms will now "ring" at the panel during two-way voice calls.
  • New wellness alarm voice annunciations.
  • New automatic volume adjustment during wellness alarms.
  • Wellness alarm notifications are now automatically cleared after (12) hours.
  • Now supports end of line resistor (EOLR) detection when using the auxiliary input on DSC PG9303, DSC PG9312, and DSC PG9945 Sensors.
  • Sensor Group 2 - Fixed Silent now available for PowerG Panic Buttons, including DSC PG9938 and DSC PG9949.
  • PowerG Sensor Supervision and Legacy Sensor Supervision (319.5 MHz, 345 MHz, 433 MHz) can now be set separately. Options from 20 minutes to 24 hours available.
  • PowerG Sensor Re-Syncing and Not-Networked Status are now dynamically displayed on main page as part of sensor status.
  • New setting that allows sounders in PowerG Smoke Detectors to activate during any alarm type.
  • PowerG Sensors are now displayed in Sensor Test in Easy Install Wizard.
  • PowerG Image Sensors (DSC PG9934P & PG9944) can now be used for visual verification for fire and carbon monoxide (CO) alarms for the central station.
  • DSC PG9902 Wireless Outdoor Curtain Motion Sensor now supported.
  • New ability to report tamper condition for Visonic KP-140, KP-141, and KP-160.
  • The PowerG Sensor Test now shows historical signal strength for PowerG Sensors.
  • Strobe lights on PowerG Sirens (DSC PG9901 & DSC PG9911B) now flash according to siren type.
  • PowerG Keypad DSC WS9LCDWF9 now supports Quick Exit feature.
  • PowerG Keypad DSC WS9LCDWF9 buzzer now stops during a two-way voice session.
  • New support for PowerG Repeater DSC PG9920 AC Loss notification.

If you have any questions about Firmware Version 2.5.0, or if you would like to learn more about our monitoring services, please email us at support@alarmgrid.com. We operate support hours from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , ,

Comments


Posted By

Like most modules that use end of line resistors for zone monitoring, the IQ Hardwire 16-F is no exception. It comes standard with 4.7k resistors, or it can support end of line resistor (EOLR) learning for values ranging from 1k to 10k. But the standard 4.7k resistors have five (5) bands.


The Qolsys IQ Hardwire 16-F is 319.5 MHz wired to wireless converter. It allows you to easily convert a wired system into a wireless system by taking over your existing hardwired sensors. The hardwired sensors will connect directly with the the IQ Hardwire 16-F module, and the converter will send 319.5 MHz wireless signals on their behalf. The system will then treat these hardwired sensors as wireless zones. You just need to make sure that you have enough wireless zones on the system itself. Each Hardwire 16-F module adds support for 16 additional hardwired zones.

If you aren't familiar with end of line resistors, they are small jumpers that are wired-in at the end of line of zones. The purpose of a resistor is to let the system know that a zone has been physically cut. If someone cuts or tampers with a hardwired zone that is configured with an EOLR, then a short will occur. This will result in a trouble condition on the system. If your system is currently in an armed state, this will cause an alarm. A shorted zone while the system is disarmed will just lead to loss of supervision for the sensor.

You must use an EOLR at each zone for the Qolsys IQ Hardwire 16-F, including with zones that do not have a connected sensor and are not actively being used. Any unit manufactured before week 40 of 2019 was required to use 4.7k resistors at all 16 zones. But from week 40 of 2019 and onward, Qolsys began manufacturing units that support end of line resistor learning. These newer units support Legacy Mode (where 1k to 10k resistors can be used) and UL Fire Mode (where 4.7k resistors must be used at every zone). For information on switching between the two (2) resistor modes, please see this FAQ.

What's somewhat unique about the 4.7k resistors included with the Qolsys IQ Hardwire 16-F is that they use five (5) bands instead of four (bands) like we mostly encounter. The 5-band resistors for the Hardwire 16-F are Yellow-Violet-Black-Brown-Brown. This equates to a 4.7k ohm resistor with a tolerance of +/- 1%. This differs from the four (4) band 4.7 k resistors that we often see, which are Yellow-Violet-Red-Gold. Those four (4) band resistors offer a tolerance of +/- 5%.

Really, there is no difference in the way you install these resistors. But it can be good to know if you are setting up a a Qolsys IQ Hardwire 16-F device. It is advised that you connect the resistors and sensors before attempting to enroll the module with the panel. We also recommend clearing the memory through a factory default for module before enrollment. More information can be found here.

If you have any questions about the Qolsys IQ Hardwire 16-F or any of our other products, or if you want to learn more about our monitoring services. Please reach out to us by emailing support@alarmgrid.com. We operate support hours from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , ,

Comments


Posted By

It's time for another Alarm Grid video recap. We only have three (3) videos for the week. But the good news is that all of the videos this week feature Jorge. We hope that you find them helpful in learning how to use your security system. Let's take a look at the new videos from Alarm Grid!

Connecting an iPhone to a Qolsys IQ Panel 2

Jorge explains how you can use an iPhone to control a Qolsys IQ Panel 2 Plus System. This is done using the iOS version of the Alarm.com Mobile App. You will need an alarm monitoring plan that includes access to Alarm.com. The panel will communicate with the Alarm.com Servers using an LTE cellular connection, and you can also set up an IP (internet protocol) communication path as well. By accessing the ADC App on your iPhone, you can arm/disarm, check system status, control automation devices, and more.


The Number of Hardwired Zones Supported On a Qolsys IQ Panel 2

Jorge explains how there are two (2) hardwired zones built into the Qolsys IQ Panel 2 Plus System. These hardwired zones are for normally closed contact sensors. You can connect the sensors and then enroll them with the panel by putting the system into its auto-enrollment mode and faulting the sensors. If you want to use additional hardwired zones with an IQ Panel 2 Plus, then a wired to wireless converter is a good option. Just make sure the converter communicates at a frequency compatible with the version of the IQ Panel 2 Plus that you have (319.5 MHz, 345 MHz, or 433 MHz).


Upgrading a Honeywell LYNX Touch to Use LTE

Jorge shows you how to upgrade a Honeywell LYNX Touch System to use an LTE cellular communicator. This is possible on an L5200, L5210, or L7000 LYNX Touch System. There are two (2) LTE communicators available for these systems. These are the Honeywell LTE-L57A (AT&T LTE) and the Honeywell LTE-L57V (Verizon LTE). You must make sure your LYNX Touch System is on a high enough firmware version to support one of these communicators. If you need to upgrade the firmware, you can do so using the Honeywell LYNXTOUCH-MSD Firmware Updater Tool.

Tags: , , ,

Comments