Alarm Grid Video Recap: August 20th - 23rd

Posted By

Hi DIYers! We're here with another video recap, this time covering August 20th thru 23rd. As usual, thanks goes out to our video team for all the hard work they do. They managed to put up some great videos this time, and we are eager to show them off. Let's check out the newest videos!

Adding a Second Push-button Keypad to a VISTA-20P

Joe teaches you how to add a second keypad to a Honeywell VISTA System. This process applies to any Alphanumeric Keypad or Fixed English Keypad. In order to set up the keypad, you must wire it to the panel and address it. You can use any address from 16-23 for a push-button keypad. Address 16 is usually for the initial keypad, so a second keypad will typically use an address of 17-23. Remember to enable the address in programming from your first keypad if needed.


Clearing a Low Battery On a VISTA P-Series Panel

Joe covers the process for clearing a low battery on a VISTA P-Series Alarm System. A low battery trouble condition occurs when battery fails a Load Test and determines that the battery cannot properly support the current load. To fix a low battery, you need to either give the battery some time to charge, or replace it with a new one. Then you must have the system pass a Load Test to clear the trouble. Remember, the typical battery life is about three (3) to five (5) years.


Properly Testing the Honeywell 5800CO with a Qolsys IQ Panel 2 Plus

Joe explains how you can properly test the Honeywell 5800CO Carbon Monoxide Sensor with a Qolsys IQ Panel 2 Plus System. This device only works with the 345 MHz version of the IQ Panel 2 Plus. You can easily test the sensor's communication with the panel by using the recessed test button. But if you want to test the sensor's ability to detect carbon monoxide gas, then you can use canned CO to complete a test. Be very careful when using canned CO!


Updating a LYNX Touch Panel Using the LynxTouch-MSD Tool

Joe is back for more, as he teaches you how to update a Honeywell L5210 or a Honeywell L7000 by using the Honeywell LYNXTOUCH-MSD Firmware Updater Tool. You might need to upgrade the firmware on one of these panels if you are trying to use an LTE communicator with the system. This includes the Honeywell LTE-L57A AT&T LTE Communicator and the Honeywell LTE-L57V Verizon LTE Communicator. You will need to power down the panel and open it up to complete the updating process.


The Difference Between Total Connect Comfort and Total Connect 2.0

Jorge explains the difference between Total Connect Comfort and Total Connect 2.0. Total Connect Comfort is an interactive platform designed strictly for use with certain Honeywell WIFI Thermostats. Total Connect 2.0 is much more robust, as it is used with Resideo Security Systems and a variety of different smart home devices, including Z-Wave devices. If you have a monitoring plan that includes access to TC2, then there is very little reason to keep using the Total Connect Comfort App.


Setting Up Automation On the Qolsys IQ Panel 2 Plus

Smiling Jarrett is back! And he's gonna show you how to set up automation on your Qolsys IQ Panel 2 Plus System. Nearly any Z-Wave smart home device can be paired with the system. The panel has a built-in Z-Wave Plus controller, so you will get maximum range and battery life if you use Z-Wave Plus devices. Before adding Z-Wave devices, you should clear it from the network first. You can also use Alarm.com to control the Z-Wave devices on your IQ Panel 2 if you have the system monitored.

Tags: , , ,

Comments