ProSeries Firmware Update - Local Programming Support
Posted By Michael GorisAfter much waiting and anticipation, Resideo has delivered the firmware update we have all been wanting for ProSeries Panels. ProSeries System Update Version 3.591.92.0 for PROA7PLUS, PROA7PLUSC, PROA7, and PROA7C introduces local programming mode, as well as other system enhancements.
First, we want to cover how to receive the update. Only monitored ProSeries Systems can be updated. You must have your ProSeries System online and connected with the AlarmNet servers in order for the over-the-air (OTA) update to go through successfully. The system must be connected with a WIFI network, as the update cannot be sent across cellular. Remember that while the PROA7PLUS and PROA7PLUSC both come with integrated WIFI network cards, the PROA7 and PROA7C can only connect to WIFI if a PROWIFIZW or PROWIFI has been added separately.
As a one-time event Alarm Grid is planning to send down the new firmware update to all its monitored customers with ProSeries Panels sometime in the coming days. This OTA update is being done in one mass shot to try to update as many users as possible all at once. No special action should be required on your part. Just have your ProSeries Panel powered on and connected to WIFI. While this process isn't perfect, and there will inevitably be some users who miss out on the update for one reason or another, this is the best way for us to ensure that as many end-users as possible have their panels updated. Remember, we can only update ProSeries Systems that are actively monitored by Alarm Grid. If you have a different monitoring provider, then ask them to help you update your system.
If your automatic OTA update fails for whatever reason, or if you didn't have your panel ready at the time of the mass OTA update, then you can request that the update be sent down manually. Alarm Grid customers can email support@alarmgrid.com to request a manual OTA update. Please make sure that you have your ProSeries Panel powered on and connected to WIFI when we push down the OTA update, or else the update process will fail. Our support hours run from 9 am to 8 pm ET M-F, so keep that in mind when contacting us. Furthermore, we cannot push down a manual OTA update to your panel if you receive alarm monitoring service from a different provider. If you are monitored by a different company, then you should instead reach out to your provider for further assistance.
There are some big highlights here in ProSeries Firmware Update 3.591.92.0. Obviously, the elephant in the room is the introduction of local programming mode. Previously, users were forced to have all system programming completed remotely by their monitoring provider. This included basic system setup tasks like enrolling sensors and configuring zone settings. Not only will the introduction of local programming make activations easier for professional technicians, but it will also empower end-users and give them greater control over their systems. This is a huge deal, as it officially makes the ProSeries Panels DIY-friendly alarm systems.
There are other major introductions in ProSeries Firmware Update 3.591.92.0, though they are likely to be overshadowed by the introduction of local programming. Nonetheless, we are still very excited about these smaller, but still important, introductions. For one, there is a boost to system partitioning, as a common lobby partition option is now available. You can set Partition 3 or Partition 4 as the common lobby, depending on how many partitions are being used. The highest number partition will always be the common lobby, and you must have at least 3 partitions in order to enable the common lobby feature.
There are some principles to keep in mind regarding the lobby function. You cannot set both Partition 3 and Partition 4 as the common lobby. Only one can be the common lobby partition at any given time. The way that the common lobby partition works is that disarming any other partition will also disarm the common lobby partition. Additionally, if ALL other partitions are armed, then the common lobby will also automatically arm. The only way you can arm/disarm the common lobby partition independently is if all the other system partitions are in an armed state. All system users have authority over the common lobby partition. Finally, any 24-hour zones assigned to the common lobby partition will sound on keypads of all partitions, but you can only silence alarms and troubles from these zones using the common partition keypad. Any faulted zone in the common lobby partition will be automatically bypassed when the common lobby partition is armed, even if it is armed automatically due to all other partitions being armed.
The ProSeries Firmware Update 3.591.92.0 brings support for some upcoming PROSiX Sensors that we hope to have available on our site very soon. Specifically, we are talking about support for the PROSiX Wireless Repeater (PROSIXRPTR) and support for the PROSiX Wireless Heat (PROSIXHEAT).
A local alarm mode is now supported, meaning you can trigger a localized system alarm, complete with siren, but without the system reporting out. This can be good for scaring away on-site intruders, while also resting easy in knowing that the authorities will not be sent to the premises. This is basically how the system behaves if an intrusion alarm occurs on a system that is not being monitored. When local alarm mode is enabled, all communication to AlarmNet is halted, including access to Total Connect 2.0 features.
The panel will now provide severe weather alerts. This feature requires that the system is set up with Total Connect 2.0 and the corresponding weather package. Remember, this is only possible if the system is monitored and set up with Total Connect 2.0. Ask your monitoring company about receiving weather alerts on the panel.
If you are using the system in Canada, you can now use the PROTLE-CN Communicator. This communicator may be carried by Alarm Grid in the future. Alarm Grid is not provided with the option to sell the Resideo and Honeywell Home lineup of Canadian communicators, however, we can get potential customers in touch with a Canadian distributor. Once you obtain a PROLTE-CN elsewhere, then we will be able to set it up for monitoring.
On the PROA7PLUS and PROA7PLUSC only, you can now stream the live video feed for Total Connect 2.0 IP Cameras and SkyBell Video Doorbell Cameras from both the Panel, as well as any PROWLTOUCH or PROWLTOUCHC Keypad. The PROA7PLUS and PROA7PLUSC also now both support disarm photos from the PROWLTOUCH and PROWLTOUCHC Keypads. Again, these two (2) features are for use with the PROA7PLUS and PROA7PLUSC only.
For all ProSeries Panels, there is backlight timeout improvement. You can now set the backlight timeout for a ProSeries Panel or a PROWLTOUCH/PROWLTOUCHC Keypad to Disable and have the screen go completely dark. This is instead of going to the "inactivity screen" that shows the weather, time & date, 1st thermostat temperature, partition arming status, panic icons, and CELL/WIFI/AC/BLE status.
Other updates include:
- You can now have Partition 1 Disarm automatically when a Z-Wave Door Lock is UNLOCKED.
- There are improvements to the 7-Day Z-Wave Thermostat Schedule on Total Connect 2.0.
- There is now optional device supervision for PROWLTOUCH & PROWLTOUCHC Keypads.
- The PROSIX Wireless Technology is now more accurate in displaying signal strength and remaining battery life.
- There is now improvement in enrollment range for PROSIXSMOKEV and PROSIXHEATV.
- There is now improved multi-language display on the PROSIXLCDKP Keypads.
- If you use a cellular communicator in Canada then you may notice Cellular Roaming Improvement.
- Updates to the ProSeries Cyber Security.
- The PROINDMV Indoor Motion Viewer and Z-Wave Devices are now supported during the AlarmNet360 Panel Replacement Process. This is only for the PROA7PLUS and PROA7PLUSC.
Are you excited about this new update? What do you think about local programming finally being available for the ProSeries Panels. Is there some other new feature that you're also really eager to check out. Let us know in a comment down below. And stay tuned to the Alarm Grid Blog for more news and updates coming soon.