February 2025 Archives

Posted By

We've all been there: you step out the door, and your phone instantly buzzes with camera notifications. If you're using Alarm.com's recording rules, you'll love this update! Now, you can set a delay of from 1 to 30 minutes before those recordings start, cutting down on nuisance notifications.

Alarm.com continues to enhance its user experience with a new recording rule setting that minimizes unnecessary notifications and maximizes video storage. By allowing users to delay recordings during exit, nuisance clips are reduced, freeing up valuable upload capacity within monthly video plan limits and ultimately saving users money.

This new delay feature is compatible with all Alarm.com cameras that support modern video analytics. Older, first-generation analytics cameras, while still functional on some accounts, do not support this feature.

Configuring the recording rule delay is...unique. We've outlined the steps below in an effort to provide clarity. You can apply this setting to both new and existing recording rules. Refer to the screenshots provided for a visual guide on enabling the delay within the rule settings.
To navigate to this section via the customer website:
  1. Log into your Alarm.com account.
  2. Click Video.
  3. Click on Recording Rules (at the top, in the blue bar).
  4. Click +Add New Rule, or find the rule you want to edit in the list, then click the pencil icon.
  5. In the section titled "Recording Rule" fill in the appropriate information. In the section for "Except when.." select "Disarmed", "Armed Stay" or both.
  6. Select the Exit Delay Time from the dropdown.
  7. Be sure to Save before exiting.

Programming the Video Rules Exit Delay via the customer website:


To navigate to this section via the customer app:
  1. Open the Alarm.com app and log in.
  2. Tap Video at the bottom of the screen.
  3. Tap the gear icon at the top right.
  4. Tap Recording Rules.
  5. Tap Add at the upper right, or scroll through the list of recording rules, find the one you want to edit and tap the pencil icon.
  6. Tap Next in the upper right once the first screen is properly configured, then scroll down to the Recording Rule section.
  7. In the "Except when.." section, select "Disarmed", "Armed Stay", or both.
  8. From the dropdown, select the Exit Delay time.
  9. Be sure to click Save before exiting.

Programming the Video Rules Exit Delay via the Alarm.com app:


Actually, the setup itself is not the tricky part. It's understanding what will happen, and when, that's a little confusing. So, here's the logic. This information was provided by Alarm.com Core Technical Support:

  • If you select "Except when Disarmed" and choose a delay from the dropdown, the recording rule will start after the delay time whenever the system is Armed Away or Stay.
  • If you select "Except when Armed Stay" and choose a delay from the dropdown, the recording rule will begin after the delay time when the panel is Disarmed or Armed Away.
  • If both "Except when Disarmed and Armed Stay" boxes are checked and a delay is selected, the recording rule will begin after the delay when the panel is Armed Away.

I'll confess, I haven't quite wrapped my head around this logic. I've found it's best if I don't overthink it! Hopefully, they'll tweak the wording and make it a little more clear somewhere down the road. Regardless, even with a slightly confusing setup, this is a fantastic addition, and I can't wait to try it out on my own system!

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , ,

0 Comments


Posted By

For those end-users who desire a more traditional keypad for their First Alert VISTAH3, the First Alert VISTAHLKP wired landscape keypad is now available. Unlike older hybrid systems like the VISTA-20P, though, this keypad will only allow you to control the security system, not program it.


Aside from its traditional appearance, the First Alert VISTAHLKP has another distinct advantage over its wireless touchscreen counterparts. It is a wired keypad, and it connects to the panel using the iBus. The VISTAH3 introduces a new bus technology called iBus that replaces the older Enhanced Console Protocol (ECP) used by the VISTA-20P and other VISTA panels.

This new bus protocol uses RS-485, a frequently used hardware and driver architecture common in industrial automation. This allows for more flexibility in wiring, and longer wire runs for wired bus devices. It is Alarm Grid's belief that every VISTAH3 panel should have at least one (1) wired keypad, for occasions when wireless keypads may not be functioning properly.


  1. 2X16 LCD Display
  2. Power LED
  3. Status LED
  4. Disarm (Off) Key
  5. Arm Maximum (Away, No Entry Delay)
  6. Arm Instant (Stay, No Entry Delay)
  7. Medical Panic
  8. Panic
  9. Fire Panic
  10. Police Panic
  11. Status (scroll)
  12. No Other Function
  13. System Tests
  14. # Key
  15. Quick Arm Night Option
  16. Chime (Toggle)
  17. Quick Arm Home Option
  18. Bypass Sensors
  19. Quick Arm Away Option
  20. Arm Stay
  21. Arm Away
  22. Trouble LED

Using the VISTAHLKP with the VISTAH3 is very similar to using a Honeywell 6160 keypad on a VISTA-20P or similar panel. The following commands can be used:

  • Arm (Away/Stay/Instant/Max/Night)
    • When the system is not ready, quick arming, if enabled, will automatically bypass faulted zones at the end of exit delay.
  • Disarm
  • GOTO (allows the user to log onto a separate partition, if their user code has access)
    • Returns to home partition after 30 seconds of no activity
  • Add/Edit/Delete User Codes
  • Bypass Zones

Excerpt from the User Guide showing Quick Arming icons and corresponding keypad commands:

Each First Alert VISTAHLKP can display either English or French language, depending on the language selection in the VISTAH3 panel. The keypad connects to the panel's iBus terminals as shown:



Wiring Limits for iBus Based on Current Draw and Wire Gauge:
Wire
Gauge
(AWG)
Total Current of All Devices Connected to a Single Wire Run
50mA or Less 100ma 300ma 500ma 600ma
#22 AWG 700' (213m) 350' (107m) 120' (37m) 70' (21m) 60' (19m)
#20 AWG 1200' (366m) 600' (183m) 200' (61m) 120' (37m) 100' (30m)
#18 AWG 1900' (579m) 950' (290m) 320' (98m) 190' (58m) 160' (49m)
#16 AWG 3000' (914m) 1500' (457m) 500' (152m) 300' (91m) 260' (76m)
If a separate power supply is used to power iBus devices, it should have a common negative with the iBus. The iBus terminals are not large, so it may be difficult to use heavier gauge wire with them.

NOTE: With ECP devices, the four wires for the bus are:

  • Negative (-), or Black
  • Positive (+), or Red
  • Data In, or Green
  • Data Out, or White/Yellow

However, the iBus connections are:

  • Negative (-), or Black
  • Positive (+), or Red
  • Data A, or Green
  • Data B, or Yellow/White

On the iBus, Data In is YELLOW, and Data Out is GREEN.

The VISTAHLKP keypad cannot be used to program the VISTAH3 system or to control smart home devices. For these capabilities, you'll need a wireless touchscreen keypad and either a PROWIFI (WIFI-Only) or PROWIFIZW (WIFI and Z-Wave Plus) module installed in the panel.

The compatible touchscreen keypads for the VISTH3 are the Honeywell Home PROWLTOUCH, Resideo PROWLTOUCHC, or First Alert VISTAHTCHWLC. Resideo has been working to dial-in their branding strategy recently, hence the different "brands" for these keypads. But, Honeywell Home, Resideo, and First Alert are all Resideo brands and all have the same robust, quality hardware.

If you choose to use the PROWLTOUCH or PROWLTOUCHC, a firmware update to the keypad is currently required (as of February, 2025) to make the keypad compatible with the VISTAH3. This firmware update can take about 30 minutes to download and install. The panel will be updated first, then the keypad. The panel won't download firmware using cellular data, so be sure the WIFI module is installed.

The primary difference between the PROWLTOUCH-style keypad and the VISTAHTCHWLC is size. The dimensions on the VISTAHTCHWLC are 5.75"L x 7.875"W x 1.0"D while the PROWLTOUCH keypads are 4.76"L x 7.68"W x 0.708"D.

You'll often find keypads near entry doors, bedrooms, kitchens, and common areas – basically, anywhere you need quick access to your security system. The VISTAHLKP is a smart choice for entry and exit doors, letting you arm and disarm the system in seconds. Another bonus? If an intruder triggers the alarm, the keypad's noise can be a good distraction. While they're dealing with that, the VISTAH3 system will be working behind the scenes to notify you and the monitoring service, depending on your monitoring plan.

For a straightforward, dependable security solution, the VISTAHLKP keypad is an excellent choice. Its wired connection to the panel ensures near 100% reliability, eliminating the potential issues associated with wireless keypads. If you're looking for simplicity and peace of mind, the VISTAHLKP delivers. Get yours today!

Tags: , , , , , , , , , ,

2 Comments


Posted By

Resideo has released several MyWebTech Technical Notifications this week. Technical Notification #119 announces a firmware update for PROSeries panels and PROWLTOUCH touchscreen keypads. Notification #121 addresses a firmware update for some legacy AT&T communicators. No action is required.

Technical Notification #119:

Technical Notification #119 announces a recommended firmware update for all PROA7, PROA7C, PROA7PLUS, PROA7PLUSC, PROWLTOUCH, and PROWLTOUCHC products. The panel firmware will be updated to version 03.2306.55, and the touchscreen keypads will be updated to version 3.424.34. This update improves WIFI connectivity between the panel and keypad.

It's important to remember that these panels cannot perform firmware updates using only an LTE cellular connection. A WIFI connection is required to download and install new firmware. This is why we strongly recommend installing a PROWIFI or PROWIFIZW module and connecting the panel to WIFI. If the panel won't use WIFI and you don't have touchscreen keypads, this update is not necessary.

Resideo is shipping updated units to their distributors. In the meantime, new panels will automatically receive any necessary firmware updates during activation and registration, provided a WIFI communication path is available.

If you have a PROSeries panel or touchscreen keypad, no action is needed. Resideo will automatically push the new firmware to all connected panels with a WIFI connection. The panel or keypad will reboot to install the update, so please be aware of this brief interruption.

In order to receive the firmware update, the product must meet this criteria:
  • Have a WIFI connection.
  • Be in a Disarmed state.
  • AC must be present.
  • Must not be in the process of reporting a signal.
  • Must not be in Walk Test Mode or Programming Mode.

Technical Notification #121:

The products affected by this notification are a little more obscure. The models affected are the LTE-IA, LTE-IC (Canada), LTE-XA, LTE-XC (Canada), LTE-CFA (Commercial Fire), and HWF2A-COM (Commercial Fire, Dialer Capture). Alarm Grid currently does not sell any of these products.

The affected AT&T communicators will receive firmware update 20.00.549.1 and AppZone firmware HW.00.1-25. These updates improve cellular connectivity with the AT&T network.

This firmware addresses minor connectivity issues reported with these units. Resideo will begin pushing the update en masse on the week of February 24, 2025. You can also manually request the update by triggering a test. For the LTE-IA and LTE-XA, briefly pressing and releasing the tamper switch initiates a test. Commercial fire products have a test button near the center of the communicator board.

During and after the update, the communicator may report the following signals:

Contact ID Code Description
E365 Cell Software Update Start
R365 Cell Software Update Finished
E366 Cell Software Update Failed
Tags: , , , , , , , , , , , , ,

0 Comments


Posted By

Resideo, in a February 17, 2025, announcement, declared the end-of-life (EOL) for its first-generation Total Connect 2.0-compatible cameras. These cameras will no longer function with the TC2 platform after July 31, 2025. Resideo recommends replacing them promptly for uninterrupted service.

The following cameras and accessories are affected by this notice:
Product Name Image
IPCAM-WI
IPCAM-WL
IPCAM-PT
IPCAM-WI2
IPCAM-WO
IPCAM-PT2A
WAP-PLUS
WREX
ACU

The VX Series cameras from Resideo are now available for use with Total Connect 2.0, providing a significant upgrade in performance and features. Improvements include enhanced image resolution and quality, sophisticated AI event detection (allowing for more precise alerts), and integrated two-way audio functionality.

The VX Series doesn't directly replace some older camera equipment. Specifically, it lacks replacements for the first-generation pan-tilt camera, the ACU (analog converter unit), and the WAP-Plus access point. If you need to replace these older devices, Resideo suggests using one or more VX5 indoor cameras in place of the IP-CAM PT/IP-CAM PT2. Cameras currently connected to ACUs should also be replaced with the appropriate VX Series camera.

Recommended VX Series Replacements for Cameras at EOL:
Product Name Recommended
Replacement
IPCAM-WI VX5 Indoor Camera
IPCAM-WI2 VX5 Indoor Camera
IPCAM-WL VX5 Indoor Camera
IPCAM-WO VX3 Outdoor Camera
IPCAM-PT/IPCAM-PT2/PT2A One or More VX5 Indoor Cameras
ACU Replace ACU and Camera with appropriate Indoor or Outdoor VX5 Camera
AP/WAP-PLUS/WREX No Replacement Available

It's true what they say: all good things must come to an end. And while the original Total Connect 2.0 cameras were mediocre by today's standards, they served a vital purpose in a market with few options at the time. They were especially useful for DIYers looking to add integrated video to their alarm systems without a lot of extra complexity.

The VX Series cameras offer the modern features customers expect, integrating seamlessly with Total Connect 2.0, PROSeries panels, and the VISTAH3 (via its touchscreen keypad). For now, Resideo is keeping it simple, offering one (1) indoor camera, one (1) outdoor camera, and one (1) video doorbell option in the VX Series.

Tags: , , , , , , , , , , , , , , , , , , ,

0 Comments


Posted By

Multiple sources have recently distributed notices regarding the Rogers 3G network. Rogers plans to sunset the 3G network on July 31, 2025. This differs from the original planned sunset on March 31, 2025. Once the network has been shut down, Rogers 3G communicators will soon begin to fail.

AT&T and Verizon ended their 3G service in 2022, but Canadian customers have had a few extra years to upgrade their devices. Now, Rogers is focusing on improving its faster LTE and 5G networks and needs to shut down the older 3G equipment.

If your system uses a Rogers 3G cellular communicator, you'll need to update it soon. Without an upgrade, eventually your system will not send alarm signals, including life-safety signals like fire and carbon monoxide alarms. This will also cause the system to display error messages.

Alarm Grid is here to help our Canadian customers upgrade their alarm systems before the Rogers 3G network shutdown. We'll be contacting you to discuss your upgrade options. Depending on your system, you may need a full upgrade or just a communicator upgrade. We'll work with you to find the best solution.

If you're not an Alarm Grid customer, we still offer a wide variety of FAQs geared toward upgrading systems and communicators. if you go to alarmgrid.com you'll find a list of these FAQs. You can also use the search bar at the top of the page to perform your own search with more specific criteria.

If you have an alarm system that is currently not monitored, or if you're not satisfied with your current service, Alarm Grid offers low-cost, no-contract monitoring plans for most systems. If you're interested in signing up for monitoring, but you're unsure whether we can monitor your system, reach out to support@alarmgrid.com.

Let us know what system you have, and if you're not sure, send us a picture of the system. From there, we may ask for more information. Once we know your system type, and whether we can access the required programming, we'll let you know if we can monitor your system. From there, you can sign up for monitoring.

If you sign up for a Self-Monitoring Plan, once the system or communicator has been upgraded and the required information has been provided, we'll create your account and email you with the login information.

If you sign up for a Full-Monitoring Plan you'll set an appointment for activation. You'll need to install the new communicator or system prior to your activation appointment. If you need support during that time, you can call us at 888-818-7728 (M - F, 9:00 am - 8:00 pm EDT). You can also email us for support, or use our chat support feature during regular business hours.

We'll give you the knowledge you need to replace any equipment necessary. You can purchase that equipment from Alarm Grid or, if you prefer, from other suppliers. Once your system is registered, we'll perform any required testing, discuss any monitoring details for Full-Monitoring Plans, then wrap things up.

Tags: , , , , , , , , , , , , , ,