Honeywell 3GL is Now Discontinued - Overview of LYNX Touch Communicators
Posted By Michael GorisUPDATE: The information presented below is outdated. The L5200 can now be updated using the LYNXTOUCH-MSD Firmware Updater Tool. Please read this blog for more information.
Alarm Grid has recently learned that the Honeywell 3GL, the longtime cellular communicator for the LYNX Touch Panels, has officially been discontinued. This leaves the Honeywell L5200 with no available cellular communicator. However, the newer LYNX Touch Systems still have cellular options.
The Honeywell 3GL was a cellular communicator that connected with the AT&T 3G Network. It was previously sold as the Honeywell 4GL. But Honeywell smartly changed the name, as it misled many people into believing it was a 4G communicator. The 3GL was compatible with the L5200, L5210 and L7000 Alarm Systems.
As for the L5210 and L7000, there are still cellular communicators available, specifically the LTE-L57A and LTE-L57V. Please note that the L5210 and L7000 must be running Firmware Version 9.00.209 or higher to support LTE-L57A, and Firmware Version 9.00.201 to support the LTE-L57V. More information on this is available here.
With the discontinuation of this module, the Honeywell L5200 now has no available cellular communicator option. Users of the L5200 who want to receive cellular monitoring should strongly consider upgrading to a newer system, such as a Honeywell Lyric Controller. This is Honeywell's newest wireless security system, and it has multiple cellular options available.
Please note that this news does not affect L5200 Systems that are already using an active 3GL Communicator. Any communicator that has already been activated will continue to function as normal. Additionally, if a user is able to find an existing 3GL or GSMVLP5-4G from somewhere else, then we can still activate it for cellular monitoring service with their L5200 System.
One alternative option for L5200 users without a cellular communicator is to go the WIFI-route instead. The system will support the L5100-WIFI module, which will allow the system to connect with a local WIFI network. Although WIFI is not as reliable as cellular service, it can be a good option if a user simply does not want to upgrade their panel. This is also a great option for Honeywell L5100 users, as that system also has no cellular radio in current production.
Finally, the ILP5 is still available for purchase, and it provides hardwired ethernet capabilities for any LYNX Touch Panel. But please note that a LYNX Touch cannot support both the ILP5 and a cellular communicator since they use the same port. Once a Honeywell LYNX Touch System is using IP or cellular communication, it will be capable of being used with the Total Connect 2.0 service.
The following table outlines all of the communicators available for the Honeywell LYNX Touch Systems and their compatibilities with each of these panels:
|
ILP5 | ||||||
Network | AT&T 2G | AT&T 3G | AT&T 4G | AT&T LTE | Verizon LTE | Wired Ethernet | WIFI |
Available | Discontinued | Discontinued | Discontinued | Yes | Yes | Yes | Yes |
Yes |
No |
No |
No |
No |
Yes |
No |
|
L5100 |
No |
No |
Yes |
No |
No |
Yes |
Yes |
L5200 |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
L5210 |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
L7000 |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
If you have any question about this news, please do not hesitate to reach out to us for further assistance. You may email us at support@alarmgrid.com, or you may call us at 888-818-7728 from 9am to 8pm EST M-F. We look forward to hearing from you.