Security Key Fobs Posts

Posted By

Hi DIYers! We have a simple, yet effective tip for you today. The tip is to keep a second key fob device by your bed for easy access. This can be a great way to trigger a panic and scare off an intruder if you hear a break-in. You can also use this key fob as a backup for your main one.

Dsc pg9929 powerg 915mhz slimline 4 button key

Being woken up in the middle of the night due to a break-in can be a very scary feeling. Most users will arm their systems to stay mode at night so that an alarm will occur if someone tries to break-in. But maybe you forgot to arm your system, or maybe you want to activate a siren to try and scare off the intruder. In that case, having a key fob next to your bed can be very helpful.

Most key fobs have a designated panic button that you can use to activate an immediate intrusion alarm. By pressing and holding this button, you are telling your system that you are in danger and that help is needed immediately. It's a great resource to have in these rare, but extremely scary, situations. Just be aware that some panels may require you to specially enroll the panic zone. Additionally, some key fobs may require dual-button presses to activate panics.

Once you activate the panic button, your system will immediately go into alarm. This can involve triggering a siren to scare off any intruders. Alternatively, you could set up a silent alarm so that the police show up without the intruder knowing. However, a loud, audible alarm will be much more effective in scaring away an intruder. You might even set up on input for an audible alarm and another for a silent alarm. It's up to you.

But keeping a key fob next to your bed is more for than just having an option for triggering a panic in the middle of the night. It's also good to have a second key fob as a backup option in case you lose or misplace your first one. You can always grab the other key fob by your bed if you need to quickly grab a fob. You can also use it to set your system to arm stay from your bed if you forgot to do so while you were by your panel or keypad earlier.

Remember, a key fob isn't the only way to access your system remotely. You can always access your system from your Android or iOS device through Total Connect 2.0 or Alarm.com. Both of these platforms offer mobile apps allow you to arm and disarm your system from anywhere. Just keep in mind that you will need a monitoring plan to use TC2 or ADC. And of course, you can always dial 911 if you believe you are in a dangerous situation. But a key fob panic can still be useful in certain situations.

And if you just want a simple device for triggering panic alarms without having arming and disarming functions, we offer standalone panic buttons as well. These are convenient devices that you can activate if you hear something suspicious to trigger an immediate system alarm. You might also consider getting outdoor sirens that you can activate to try and scare away anyone lurking outside your home. And remember that if you have monitoring service, you can set up how your system responds during alarm events. This includes what action(s) the central station will take and when you receive text, email, and/or push notifications regarding any triggered panics.

If you do decide to get additional key fob devices or a panic button for your system, you will need to make sure they are compatible. Our team can help you with that. Remember that we offer free support for all our monitored customers. We can help you determine the perfect key fob option for your needs so that you can your family can feel safe at home. The best way to contact us is to email support@alarmgrid.com. We will check your email at our earliest convenience and reply back as soon as possible. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , , ,

Comments


Posted By

One of the most versatile security key fobs on the market today is the Honeywell 5834-4. This is a wireless four button key fob with up to eight different programmable functions. The device will function from up to 50 feet away from the system. This makes the 5834-4 a convenient tool for quickly arming and disarming your system and performing other useful functions. This helpful guide will tell you everything you need to know about the 5834-4 key fob so that you can fully integrate it into your security setup.


Overview of the 5834-4 and Other 5800 Series Key Fobs

The Honeywell 5834-4 is actually the same security key fob that ADT provides for their monitored customers. This means that an ADT Key Fob can generally be used in the exact same manner as a 5834-4. If an ADT customer decides to leave ADT, they will most likely be able to use their old ADT Key Fob with their new monitoring company. A user can program their old ADT Key Fob with any compatible alarm system, even if the device has not been deleted from the old system. That said, we do recommend deleting the device from the old system if possible.

The 5834-4 is recognized as a wireless sensor from the Honeywell 5800 Series. Just like the other devices in this lineup, the 5834-4 Key Fob operates at a wireless frequency of 345 MHz. It will interface with any control panel that utilizes this wireless frequency. This includes the Honeywell Lyric Controller, Honeywell LYNX Touch Panels, Honeywell VISTA Panels (with an added wireless receiver), the 2GIG GC3 and the 2GIG GC2. In order to achieve the maximum functionality of the device, the 5834-4 will require eight separate wireless zones on the system.

The 5834-4 can perform system commands at a maximum distance of up to 50 feet away from the alarm system, though a Honeywell 5800RP Wireless Repeater can be used to extend this range. Also, any button press that is made using the 5834-4 must be held down for half a second before the programmed action will go into effect. This helps to prevent potential false alarms caused by the key fob.

In addition to the 5834-4, Honeywell produces two other key fob devices that are very similar in terms of use. The 5834-2 features two buttons and up to three programmable functions. This two-button key fob is a good option for users who do not require a device with as many functions as the 5834-4. Honeywell also offers the 5834-4EN. This is literally the exact same device as the 5834-4. The only difference is that the 5834-4en features a design with a pleasant silver finish.

Enrolling the 5834-4

Each function on a 5834-4 Key Fob is assigned its own wireless zone on a security system. This means that if every possible button entry is set up, the device will take up eight wireless zones. Each button entry can be learned-in with the security system, much in the same way as any other wireless security sensor. With the panel in its learn mode, press and hold the button entry you want to program. The panel will beep to let you know that it has recognized the key fob. Do this three times to auto-enroll that button press with the system.

Please note that some alarm panels will require you to use the panel's designated "key fob zones" to auto-enroll the 5834-4 with the system. For these panels, attempting to assign the 5834-4 with a non-key fob zone will require that the serial number be entered in manually rather than being learned-in automatically. While the 5834-4 can technically be used with any wireless zone, we always recommend assigning the device to a key fob zone if possible. The exact zone numbers for the key fob zones vary between different alarm panels.

Also note that most panels will have a specific sub-menu within programming for setting up key fobs. By setting up a 5834-4 through this sub-menu, the device inputs will automatically be assigned to a designated key fob zone on the system. Again, we strongly recommend setting up a 5834-4 key fob through the key fob sub-menu for the panel.

The table below outlines the key fob zone numbers for various types of alarm systems:

Panel Type
Key Fob Zones
Honeywell VISTA-15P 49-56
Honeywell VISTA-20P & VISTA-21iP 49-64
Honeywell LYNX Touch 140-147
Honeywell Lyric Controller 131-162
2GIG GC2 51-58
2GIG GC3 32 Key Fob Zones*
*Note: The 32 key fob zones on a 2GIG GC3 are considered separate from other wireless zones.

The 5834-4 uses two different 7-digit Serial Numbers. The second Serial Number is one digit higher than the first Serial Number. So for example, if the first Serial Number is 123-4567, then the second Serial Number would be 123-4568. The first Serial Number is used with all single-button presses, while the second Serial Number is used with multi-button presses. Each unique input is assigned a Loop Number 1-4. This means that each of the eight possible inputs will have a Serial Number and Loop Number combination that is unique from all the others. This is shown in the following diagram:

Note that each button is identified by a different letter. The button in the upper-left corner with the closed lock is Button A. The button in the upper-right corner with the open lock is Button B. The button in the lower-left corner with the person standing inside the house is Button C. The button in the lower-right corner with the asterisk (*) is Button D.

Please note that the button combinations of A+D and B+C are not used with the system. But all other two-button combinations are fair game. Serial Number 2 will be one digit higher than Serial Number 1. The following table outlines every Serial Number and Loop Number combination used with the 5834-4 Key Fob:

Input Serial Number Loop Number
A 1 3
B 1 2
C 1 4
D 1 1
A+B 2 1
A+C 2 3
B+D 2 4
C+D 2 2

Configuring the 5834-4

Once an input has been enrolled with the panel, you must then configure the settings for that input. The exact options for for this will vary depending on the type of panel that is being used. Most options are fairly self-explanatory and can be configured with relative ease. For example, below are the menu options displayed for a Honeywell LYNX Touch L7000, assuming that the device is being programmed through the key fob menu. Please note that these are essentially the same menu options that will also be displayed on any other Honeywell LYNX Touch Panel, as well as the Honeywell Lyric Controller. Make sure to save your changes when you have finished configuring the key fob settings.

  • Key Type: This tells the panel how many different inputs are used on the key fob device. Since a 5834-4 Key Fob with eight different possible inputs is being used, the option "8 button" is chosen.
  • User: This will show in the event log which user interacted with the panel. This is great for assigning different system users their own personal key fob.
  • Serial Number: This is the Serial Number for the key fob. If the Serial Number is entered incorrectly, the key fob will not work with the system. For that reason, we strongly recommend auto-enrolling the 5834-4 with the system.
  • Zone: This is the first zone on the system that the key fob will be assigned to. That zone, and the following seven zones will be used with that key fob.
  • Button Key 1: Button A on the 5834-4. This is the picture of the closed lock. This lets you choose the action that will be taken for that input.
  • Button Key 2: Button B on the 5834-4. This is the picture of the opened lock. This lets you choose the action that will be taken for that input.
  • Button Key 3: Button C on the 5834-4. This is the picture of the person standing in the house. This lets you choose the action that will be taken for that input.
  • Button Key 4: Button D on the 5834-4. This is the picture of the asterisk (*). This lets you choose the action that will be taken for that input.
  • Button Key 5: Button combination A+C on the 5834-4. This lets you choose the action that will be taken for that input.
  • Button Key 6: Button combination C+D on the 5834-4. This lets you choose the action that will be taken for that input.
  • Button Key 7: Button combination B+D on the 5834-4. This lets you choose the action that will be taken for that input.
  • Button Key 8: Button combination A+B on the 5834-4. This lets you choose the action that will be taken for that input.

Also take note of the different possible actions that can be used with each possible input:

  • Disarm: This will disarm the system if the system is set to armed stay or armed away.
  • Arm Away: This will set the system to armed away.
  • Arm Stay: This will set the system to armed stay.
  • No Response: The input will not be used with the system.
  • 24 Hour Silent: This will produce a silent alarm on the system. This essentially allows the 5834-4 to be used as a silent panic switch.
  • 24 Hour Audible: This will produce an alarm event on the system. Any sirens and sounders set up with the system will activate.
  • 24 Hour Auxiliary: This will produce an alarm event on the system. The system sounder will activate, but any sirens will not. This is typically used for medical emergencies.
  • Silent Burglary: This will produce a silent alarm on the system. However, this command will only work if the system is armed.
  • Fire No Verification: This will produce a fire alarm on the system.

Standard Mode vs. High-Security Mode

the 5834-4 Key Fob features two different transmitting modes. These are standard mode and high-security mode. Simply put, standard mode has the 5834-4 function as an unencrypted device, while high-security mode has it function as an encrypted device. Putting the 5834-4 into high-security mode will make it nearly impossible for others to hack or compromise the device. However, high-security mode is only compatible with alarm panels that support this feature. For panels that do not support this feature, the 5834-4 Key Fob must be placed in standard mode before it can be used with the system. Some panels that do not support high-security mode include the 2GIG GC3 and the 2GIG GC2.

To activate high-security mode on the 5834-4 Key Fob, press and hold the A+C+D buttons on the device simultaneously for five seconds. The LED light on the device will flash red to indicate that the device has been placed into high-security mode. Once in this mode, any input made using the 5834-4 Key Fob will cause the LED light on the device to flash red.

To activate standard mode on the 5834-4 KeyFob, press and hold the B+C+D buttons on the device simultaneously for five seconds. The LED light on the device will flash green to indicate that the device has been placed into standard mode. Once in this mode, any input made using the 5834-4 Key Fob will cause the LED light on the device to flash green.

The 5834-4 Battery

The Honeywell 5834-4 Key Fob uses a 3-volt CR2032 lithium battery. Every new 5834-4 comes included with a fresh battery that is already installed. The battery should last for about three to five years before requiring a replacement. As the key fob is used, the power that is supplied by the battery will being to slowly drop. Once the power drops below 2.3 volts, a low battery message will be displayed on the alarm system. Please note that this message will only appear if a button is pressed on the key fob. If the key fob is not used, then the panel will not recognize that the battery is low. Additionally, once the battery is low, the LED light on the key fob will no longer flash when an input is made. If the power drops below 2.0 volts, then the device will stop working entirely.

To replace the battery, use a small Phillips head screwdriver to remove the screw on the back of the device. Then slide a flathead screwdriver underneath the battery on the side with the gold tab to pop the battery out. With the old battery removed, slide the new battery into place, making sure that the positive (+) side is facing upwards. Firmly press down on the opposite side to click the battery into place. Finally, reapply the back cover, and screw it into place. Make sure to test the 5834-4 Key Fob after replacing the battery to ensure that it has been installed properly.


If You Need Further Help

The Alarm Grid support team is happy to help any monitored customer with using their 5834-4 Key Fob. Please contact us via email at support@alarmgrid.com or over the phone at 888-818-7728 from 9am-8pm ET M-F if you require further assistance.

Tags: , , , , , , ,

Comments


Posted By

Honeywell has informed us that they are discontinuing production of the largely disused two-button key fob, the 5834-2. The remote fob was made to simply offer an arm and disarm option, but did not allow for an arm stay or a panic function. While, theoretically, removing those buttons would give users the ability to avoid false alarms through mis-presses, the 5834-2's proven to be a fairly unpopular key fob compared to its contemporary the 5834-4.

Used largely with the LYNX series panels such as the L5200 or L7000, the 5834-4 key fobs (as well as the 5834-2) allow for the arming and disarming without the need to enter a code into the panels themselves. This functionality is well loved by end users, and is the reason the 5834-4 has become one of the more popular options, even coming with the available kits for the LYNX panels. But while users will often find themselves purchasing multiple 5834-4s for the system, since the 5834-4 offers the versatility of an end-user programming it to function exactly like the 5834-2, this key fob has been rendered redundant. Alarm Grid has discontinued the item on the site.

For those who want to know how to program a key fob to one of these simple, wireless systems, we have made a series of programming videos for the 5834-4. For those that are looking for functionality that mimics the 5834-2, simply delete the arm stay function which is indicated by the small home picture on the key fob. That would make only the arm stay and arm away buttons work with the system, exactly as the 5834-2 works.


Tags: , , ,

Comments