Resideo has released Technical Notification #90 due to an issue in manufacturing. In this case, tamper switches on the 5800MINI were installed incorrectly. There is a sales hold on these units to allow a correction of this issue. Only white units are affected, this did not affect brown units.

The 5800MINI is a popular option. It has a small footprint and a convenient blue LED that indicates proper magnet alignment. Recently we have noticed that these units have been back ordered and are currently unavailable. This is most likely the cause.

The 5800MINI, like most wireless sensors, uses an internal tamper button to detect any unauthorized opening of the sensor. This button varies depending on the sensor, but in most cases on the cover, you typically will have a protruding plastic piece that is intended to press down on the tamper switch to close it when the cover is properly installed.

The defective units had this tamper button installed upside down. So when the cover is installed, the plastic piece built into the cover is not making contact with the actual tamper button. They have identified the faulty units to have been manufactured between February 13, 2023 and April 17, 2023. This would mean the date codes on these defective units will show 2307 through 2316. The date code consists of a 2-digit year, and 2-digit week of the year. The date codes can be found on a label on the box that the 5800MINI comes in.

If you recently installed an affected unit, you will likely already know, because the sensor will have indicated a tamper trouble that will not clear, even with the cover properly installed. Holding down the tamper with your finger and then disarming will allow you to clear it, though.

Commercial panels like the Vista-128BPT, have a feature that allows them to ignore zone tampers. This is enabled in programming field *24. If this feature is enabled on your commercial panel, you may not be aware of a tamper issue, as enabling this feature tells the panel to ignore all 5800 and polling loop zone tampers.

If you are currently installing one of these faulty sensors, and need a workaround until your warranty replacement arrives, there is an option. The 5800MINI, reports its tamper on loop 4. On Vista-15p, Vista-20p, and Vista-21ip panels, if you have an available unused wireless zone, you can program the serial number from the 5800MINI using loop 4 and use a non-response zone type, such as zone type 23 (no alarm response). For Lynx, Lyric, and PROA7PLUS panels, you can select "Other" as Device Type and "No Response" as the Response Type. Then the tamper will be ignored.

If you no longer have the box to visually identify the defective 5800MINI units by date code, compare yours with the pictures below. In the first picture, the IC chip is mostly covered with the serial number label, but the tamper button should be on the side closer to this chip. It is not. It is closer to the edge of the sensor.


If properly installed, the tamper should look like the second picture shown below. The IC chip is clearly shown in this image. It's a black square with a white dot in the middle. The black tamper button is on the side closest to this chip.


If you encounter one of these faulty devices, please contact the distributor or retailer where you purchased it. They can inform you of their method for resolving this issue. Alarm Grid customers can begin this process by emailing a picture of their faulty device's tamper switch and including the order number, if available. If you don't have the order number, please provide the email address associated with the order. Alarm Grid customers with defective devices will be sent a warranty replacement when the new ones are available. We can also offer you the workaround mentioned above, until the new product is available.

Resideo is offering the 5815 2-zone door and window sensor as a temporary replacement until 5800MINIs become available. For now, it will be at the same price as the 5800MINI. At alarmgrid.com we have made this adjustment to the pricing of the 5815. The 5815 has been lowered to a price of $24.99 until this issue is resolved. Please stay tuned for any updates on this issue, as we receive them.

Tags: , , , , , , , , , , , , , ,

Comments


Posted By

Resideo has released Technical Notification #90 due to an issue in manufacturing. In this case, tamper switches on the 5800MINI were installed incorrectly. There is a sales hold on these units to allow a correction of this issue. Only white units are affected, this did not affect brown units.

The 5800MINI is a popular option. It has a small footprint and a convenient blue LED that indicates proper magnet alignment. Recently we have noticed that these units have been back ordered and are currently unavailable. This is most likely the cause.

The 5800MINI, like most wireless sensors, uses an internal tamper button to detect any unauthorized opening of the sensor. This button varies depending on the sensor, but in most cases on the cover, you typically will have a protruding plastic piece that is intended to press down on the tamper switch to close it when the cover is properly installed.

The defective units had this tamper button installed upside down. So when the cover is installed, the plastic piece built into the cover is not making contact with the actual tamper button. They have identified the faulty units to have been manufactured between February 13, 2023 and April 17, 2023. This would mean the date codes on these defective units will show 2307 through 2316. The date code consists of a 2-digit year, and 2-digit week of the year. The date codes can be found on a label on the box that the 5800MINI comes in.

If you recently installed an affected unit, you will likely already know, because the sensor will have indicated a tamper trouble that will not clear, even with the cover properly installed. Holding down the tamper with your finger and then disarming will allow you to clear it, though.

Commercial panels like the Vista-128BPT, have a feature that allows them to ignore zone tampers. This is enabled in programming field *24. If this feature is enabled on your commercial panel, you may not be aware of a tamper issue, as enabling this feature tells the panel to ignore all 5800 and polling loop zone tampers.

If you are currently installing one of these faulty sensors, and need a workaround until your warranty replacement arrives, there is an option. The 5800MINI, reports its tamper on loop 4. On Vista-15p, Vista-20p, and Vista-21ip panels, if you have an available unused wireless zone, you can program the serial number from the 5800MINI using loop 4 and use a non-response zone type, such as zone type 23 (no alarm response). For Lynx, Lyric, and PROA7PLUS panels, you can select "Other" as Device Type and "No Response" as the Response Type. Then the tamper will be ignored.

If you no longer have the box to visually identify the defective 5800MINI units by date code, compare yours with the pictures below. In the first picture, the IC chip is mostly covered with the serial number label, but the tamper button should be on the side closer to this chip. It is not. It is closer to the edge of the sensor.


If properly installed, the tamper should look like the second picture shown below. The IC chip is clearly shown in this image. It's a black square with a white dot in the middle. The black tamper button is on the side closest to this chip.


If you encounter one of these faulty devices, please contact the distributor or retailer where you purchased it. They can inform you of their method for resolving this issue. Alarm Grid customers can begin this process by emailing a picture of their faulty device's tamper switch and including the order number, if available. If you don't have the order number, please provide the email address associated with the order. Alarm Grid customers with defective devices will be sent a warranty replacement when the new ones are available. We can also offer you the workaround mentioned above, until the new product is available.

Resideo is offering the 5815 2-zone door and window sensor as a temporary replacement until 5800MINIs become available. For now, it will be at the same price as the 5800MINI. At alarmgrid.com we have made this adjustment to the pricing of the 5815. The 5815 has been lowered to a price of $24.99 until this issue is resolved. Please stay tuned for any updates on this issue, as we receive them.

Tags: , , , , , , , , , , , , , ,

Comments


Posted By

Door contacts represent some of the most popular sensors that are used with alarm systems. Nearly every setup will incorporate these devices in some form. After all, knowing when a door has been opened is critical for most systems. But there is a lot to consider when choosing door contacts.

Honeywell 5816 wireless door window sensor

A door sensor is a device that is used to let an alarm control panel know when a door has been opened. When this happens, the system will respond depending on panel's current arming state and the programming settings for the zone. Some popular responses for door contacts include requiring a system disarm within the entry delay period, producing a simple chime and triggering an immediate alarm. These responses are present with virtually any door contact and system setup. A previous blog post of ours actually covers the Response Types for door sensors in greater detail. We recommend checking out that post for more information. But while the general functionality is the same across almost any contact, selecting the best option for your system might seem overwhelming.

Perhaps the first thing you should consider is whether you want a hardwired contact or a wireless contact. A wired contact will communicate with the panel through a direct hardwired connection. A wireless contact will communicate with the panel through wireless RF signals. The advantage to a wireless sensor is that it will be much easier to set up, since no wires will need to be run from the system to the sensor. But some users prefer hardwired sensors, as they essentially become a fixture for the building itself. Another advantage to hardwired contacts is that they don't use batteries. This means that a user will never have to buy new batteries for their hardwired contact. There are all types of door sensors in both the hardwired and wireless variety.

If you choose a hardwired contact, you will need to have a hardwired zone available on your system. Most hardwired contacts can be used with nearly any system that supports hardwired sensors. On the other hand, if you choose a wireless contact, you will need to have a wireless zone available. You will also need to make sure the wireless contact communicates at an RF frequency that is compatible with your system. Knowing which wireless RF signals are accepted by your alarm system is very important for getting sensors to work properly. Some of the most popular RF signals used by alarm systems include 319.5 MHz, 345 MHz, 433 MHz, 915 MHz and 2.4 GHz. Remember to always make sure the wireless door contact you choose operates at a frequency that works with your alarm system!

Qolsys iq dw mini s encrypted wireless sensors for iq panel 2 qs

Honeywell pal t wh surface mount door contact and window contact

Another major distinction for door contacts is whether they are surface-mounted or recessed. A surface-mounted contact is visible on the outside of the door. A recessed contact is hidden inside the door and its frame. As a general rule, surface-mounted contacts are easier to install, since no holes need to be drilled. But the advantage to recessed contacts is that the end result can appear neater, since no sensor will be visible. We generally recommend that users installed surface-mounted sensors, due to the fact that they are easier to install and generally offer more reliable performance.

With that in mind, door sensors can be assigned to one of four major categories. These are wireless surface-mounted contacts, wireless recessed contacts, hardwired surface-mounted contacts and hardwired recessed contacts. Regardless of which category a door contact is assigned, these devices generally all work in the same way. Most door contacts consist of a sensor and a magnet. The sensor is installed on the stationary portion of the door frame, while the magnet installed on the moving portion of the door. In most cases, the magnet must be within a half-inch of the sensor. Placing the sensor itself on the stationary portion of the door helps prevent it from being damaged when the door is opened or closed. Once the door is opened, the magnet will separate from the sensor and cause a reed switch inside the sensor to activate. The sensor will then alert the system to let it know that the door has been opened. Please note that there are a few door sensors that are exceptions to this general operation. Namely, recessed sensors that use a plunger switch, like the wireless Honeywell 5800RPS and the hardwired Honeywell 956RPT.

Honeywell 5818mnl wireless recessed door sensor and window sensoBefore we get into general door contacts that would be used for most applications, we want to make special mention of some more unique sensors that would be used for specific setups. Honeywell offers many hardwired wide-gap contacts that can be used with garage doors and industrial applications. The advantage to these sensors is that they can utilize a much larger spacing gap between the sensor and magnet than what is possible with standard door contacts. We have seen some industrial contacts where the spacing gap can be up to 2.5 inches. That's five times the recommended maximum spacing gap for standard door contacts! Some examples of these industrial-grade hardwired contacts include the Honeywell 958, the Honeywell 968XTP, the Honeywell 959, the Honeywell 958-2, the Honeywell 950W, the Honeywell 960 and the Honeywell 7945. Many of these industrial-grade contacts are also suitable for outdoor use. Another option for a garage door is to use a tilt sensor, like the Honeywell 5822T or an Interlogix TX-E401.

But if a user requires a wireless contact for an outdoor application, there only option is really the Honeywell 5816OD. This wireless contact offers a recommended maximum spacing gap of 1.5" inches, and it is great for use with fences and outside doors. It has a nominal range of 200 feet when used with most systems. As a 345 MHz Sensor from the Honeywell 5800 Series, it will work with nearly any Honeywell Alarm System.

Honeywell 5816od wireless outdoor door and window sensor topIf you don't require an industrial or an outdoor contact, you will most likely be able use a relatively standard contact with your alarm system. We prepared a table below that outlines many of the most popular and widely used door contacts sold by Alarm Grid. Please note that not every contact is included - there would be too many to list! But this is a good chart to help you find the perfect sensor for your system.

Sensor Name
Communication Frequency
Surface-Mounted or Recessed
Special Notes
VERSA-GE 319.5 MHz Surface-Mounted Same as 5800MINI, but for 319.5 MHz Systems.
VERSA-2GIG 345 MHz Surface-Mounted Same as 5800MINI, but will only work with 2GIG Systems, the Honeywell Lyric Controller, and the IQ Panel 2 Plus with 345 MHz Daughercard.
Honeywell 5800MINI
345 MHz Surface-Mounted Very popular slim sensor that is used with Honeywell Systems.
Honeywell SiXMINICT 2.4 GHz Surface-Mounted Encrypted 2.4 GHz Sensor designed for use with Lyric System only. It is smaller and more discreet than the similar SiXCT, but offers less range. Uses 128-bit AES encryption.
Honeywell SiXCT 2.4 GHz Surface-Mounted Encrypted 2.4 GHz Sensor designed for use with Lyric System only. Larger than the SiXMINICT, but offers superior range. Uses 128-bit AES encryption.
Qolsys IQ DW MINI-S 319.5 MHz Surface-Mounted Encrypted S-Line Sensor. Will only utilize encryption when used with an IQ Panel 2 or IQ Panel 2 Plus System. Otherwise operates as standard unencrypted sensor. Mini version of IQ Door Window-S.
Honeywell 5818MNL 345 MHz Recessed Recessed sensor from Honeywell 5800 Series. Requires 0.75" diameter hole that is 3" deep to be drilled in the door frame.
Honeywell 5820L 345 MHz Surface-Mounted Slim Line sensor that is great for applications that require a thinner sensor.
2GIG DW10 345 MHz Surface-Mounted Door contact designed by 2GIG. Will only work with 2GIG Systems, the Honeywell Lyric Controller, and the IQ Panel 2 Plus with 345 MHz Daughtercard.
Honeywell 5816 345 MHz Surface-Mounted Honeywell's most popular wireless sensor! Also includes a wireless transmitter for a normally closed hardwired device.
DSC PG9945 915 MHz Surface-Mounted PowerG Sensor with up to 2km range. Also features an auxiliary input and wireless transmitter for a normally closed hardwired device. Uses 128-bit AES encryption.
Qolsys IQ Door Window-S 319.5 MHz Surface-Mounted Encrypted S-Line Sensor. Will only utilize encryption when used with an IQ Panel 2 or IQ Panel 2 Plus System. Otherwise operates as standard unencrypted sensor. Larger version of IQ DW MINI-S.
Interlogix TX-E221 319.5 MHz Recessed Relatively standard recessed sensor that works with 319.5 MHz systems.
2GIG DW20R 345 MHz Recessed Recessed contact from 2GIG. Will only work with 2GIG Systems, the Honeywell Lyric Controller, and the IQ Panel 2 Plus with 345 MHz Daughtercard.
DSC PG9975 915 MHz Surface-Mounted PowerG vanishing surface-mounted contact with thin profile. Great for any standard application where PowerG Sensors are supported.
Qolsys IQ Recessed Door-S 319.5 MHz Recessed Encrypted recessed sensor from Qolsys. Will only utilize encryption when used with an IQ Panel 2 or IQ Panel 2 Plus System. Otherwise operates as standard unencrypted sensor.
Qolsys IQ Mini 319.5 MHz Surface-Mounted Standard door and window contact from Qolsys. Same as IQ DW MINI-S, but without encryption features.
DSC WS4945 433 MHz Surface-Mounted Surface-mounted door contact for 433 MHz DSC Systems.
DSC EV-DW4975 433 MHz Surface-Mounted Slim line version of DSC WS4945.
DSC EV-DW4917 433 MHz Recessed Recessed door contact for 433 MHz DSC Systems.
Qolsys IQ DW Standard 319.5 MHz Surface-Mounted Unencrypted version of Qolsys IQ Door Window-S.
Honeywell 951WG Hardwired Recessed Recessed hardwired contact with leads. Measures 3/8" in diameter.
Honeywell PAL-T Hardwired Surface-Mounted Currently the smallest hardwired surface-mounted contact offered from Alarm Grid.
Honeywell 7939WG Hardwired Surface-Mounted Relatively standard hardwired surface-mounted contact manufactured by Honeywell.
Honeywell 944T Hardwired Recessed Recessed hardwired contact with screw terminals. Measures 3/8" in diameter.
Honeywell 944TSP Hardwired Recessed Recessed hardwired contact with screw terminals. Measures 3/4" in diameter.
Honeywell 7939-2 Hardwired Surface-Mounted Basically same as Honeywell 7939WG, but is Form C for normally closed or normally open wiring.
Honeywell 940 Hardwired Surface-Mounted Relatively standard hardwired surface-mounted contact manufactured by Honeywell.
Honeywell MPS5 Hardwired Recessed Recessed contact with leads and diameter of 1/4".
Honeywell 944SP Hardwired Recessed Recessed contact with leads and diameter of 3/4".

If you're still having trouble deciding on the perfect door contact for your alarm system, our experts are always happy to help. You may email us at support@alarmgrid.com, and we will get back to you as soon as possible. You may also call us at (888) 818-7728 during normal business hours, which are 9am to 8pm EST M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , , , ,

Comments


Posted By

Honeywell is known for producing some outstanding security equipment, and their wireless door and window contacts are no exception. With wireless contacts available from both the 5800 Series lineup and the SiX Series lineup, there are certainly some great options. But with all the possibilities, it might seem overwhelming if you are just getting started. This guide will help you choose the perfect wireless Honeywell door and window contact for your needs.

Honeywell 5820l super slim wireless door and window sensorFirst, a user should understand exactly how a door and window contact works. Almost every wireless Honeywell door and window contact functions using the exact same principles. These devices consist of a sensor and magnet. The sensor is the "brains" of the operation, and it is responsible for sending signals to the alarm system. It is typically installed on or inside the door or window frame. The magnet is installed on or inside the door or window itself. The only wireless Honeywell contact that does not use a magnet is the Honeywell 5800RPS. This is a wireless recessed sensor for doors only that operates using a plunger switch.

For proper operation, the device's magnet should be installed very close to the sensor. We usually recommend placing it within a half-inch of the sensor. However, some 5800 Series contacts, like the 5816OD, can function properly with a slightly larger spacing gap. When the door or window is opened, the magnet will separate from the sensor. This will cause a reed switch inside the sensor to activate. When this happens, the sensor will send a signal to the alarm system so that the programmed Response Type can be performed.

It's also important to know the system compatibilities for the different Honeywell wireless contacts. Their wireless contacts come from two different sensor lineups. These are the 5800 Series and the SiX Series. The 5800 Series contacts are unidirectional devices that operate at 345 MHz. This makes them compatible with any Honeywell System or 2GIG System. But the SiX Series contacts are bi-directional, fully encrypted sensors that communicate using 2.4 GHz WIFI. These sensors only work with Honeywell Lyric Systems.

Honeywell lyric controller encrypted wireless security system

If you have a Honeywell Lyric Controller, then you can choose between any Honeywell wireless contact on the market. But if you have a LYNX Touch or a VISTA System with an added wireless receiver, then you are restricted to the 5800 Series contacts. Additionally, if you are using a 2GIG GC3 or a 2GIG GC2, then you can use either 2GIG Contacts or Honeywell 5800 Series contacts. Any alarm systems that do not accept the 345 MHz frequency are unable to use Honeywell contacts.

The only two contacts in the Honeywell SiX Series Lineup are the Honeywell SiXCT and the Honeywell SiXMINICT. These are both wireless, surface-mount sensors that work exclusively with Honeywell Lyric Systems. What makes these sensors special is that they feature 128-bit AES encryption. Whenever the sensor sends a command to the Lyric System, the system must then send a secure response back to the sensor. The command will only go through if this secure response is received. Many security experts refer to this as a "digital handshake", and it is excellent for preventing any hacking attempts or wireless attacks.

The SiXCT and the SiXMINICT do have a few slight differences. Most notably, the SiXMINICT is smaller and more compact than the SiXCT. The SiXCT measures at 3.13”L x 1.61”W x 1"D, while the SiXMINICT measures at 2.44”L x 1.25”W x .45”D. So users who want a smaller sensors should go with the SiXMINICT. But the benefit of the SiXCT is that it features a larger wireless range (~300 feet) than the SiXMINICT (~200 feet). However, only users with particularly large properties should have to worry about signal range. One thing that these sensors do share in common is that they can both be batch-enrolled with the Lyric Controller.

  • Honeywell SiXCT - The standard SiX Series contact. Features a 300 foot range and encryption. Will only work with Lyric Systems.
  • Honeywell SiXMINICT - The more compact SiX Series contact. Provides a 200 foot range and encryption. For Lyric Systems only.

Honeywell sixct wireless door slash window contact for lyric conHoneywell sixminict wireless door slash window contact for lyric

But the SiX Series contacts aren't for everyone. For one, they will only work with the Lyric Systems. There are also no recessed contacts in the SiX Series lineup. Users who don't have a Lyric Controller or want a recessed sensor should look to the Honeywell 5800 Series instead. This is an incredibly diverse sensor lineup that has an appropriate contact option for virtually any situation. Any Honeywell or 2GIG System will work with these sensors. This includes any Lyric Controller, L7000, L5210, VISTA P-Series, 2GIG GC3, 2GIG GC2 and more. Most 5800 Series contacts feature a 150-200 foot wireless range that can be effectively doubled with the use of a 5800RP Wireless Repeater.

Honeywell l7000 wireless home security system with 7 inch screenHoneywell 5800rp wireless repeater

When selecting a 5800 Series Sensor, a user will choose between a surface-mount contact and a recessed contact. With a surface-mount contact, the sensor and the magnet are mounted on the outer surface of the door or window and its frame. But with a recessed contact, the sensor and magnet are installed inside the door or window and its frame. Surface-mount sensors are very easy to install, since they only require screws or double-sided foam tape. But the sensor will be visible on the outside of the door. Recessed sensors are more difficult to install since holes will need to be drilled. However, some users will appreciate the fact that recessed sensors are hidden.

For users who go with a surface-mount sensor there are certainly some great options in the 5800 Series. One of our favorites is the 5800MINI. This is a reliable sensor that boasts an impressive 200 foot range, despite its small size of just 2.2"H x 1"W x 0.25"D. This is arguably the best surface-mount contact in the Honeywell 5800 Series.

  • Honeywell 5800MINI - A small and discreet surface-mount contact. Offers a 200 foot wireless range. Great for almost any application.

Honeywell 5800mini interior wireless door and window sensor

But there are other surface-mount options than just the 5800MIIN. The 5816 is the most popular sensor that Honeywell has ever offered. It features a larger size and roughly the same range as the 5800MINI. But unlike the 5800MINI, the 5816 can be used as a wireless transmitter for a normally closed hardwired device. Honeywell also offers the 5820L Slim Line for narrow installations and the 5816OD for outdoor use.

  • Honeywell 5816 - Honeywell's most popular sensor. Can also be used as a wireless transmitter for a single NC hardwired device.
  • Honeywell 5820L - A slim line door and window contact that is great for narrow applications. Features a 150-foot range.
  • Honeywell 5816OD - A surface-mount contact for outdoor installations. Excellent for monitoring fences, sheds and detached garages.

Honeywell 5816 wireless door window sensorHoneywell 5816od wireless outdoor door and window sensor top


Honeywell also offers some less popular 5800 Series contacts. These include the 5811 (discontinued), the 5814, the 5815 and the 5816MN (discontinued). While these sensors will work just fine, there isn't really any reason to choose them over another 5800 Series contact.

  • Honeywell 5811 - A small and discreet sensor that has since been discontinued. Replaced by the Honeywell 5800MINI.
  • Honeywell 5814 - Another compact sensor option. It is not as robust as the 5800MINI. Its wireless range is only about 100 feet.
  • Honeywell 5815 - An aesthetically pleasing surface-mount contact that has roughly the same functionality as the 5816.
  • Honeywell 5816MN - A discreet surface mount sensor that has been discontinued. Replaced by the Honeywell 5816MN.

Honeywell 5814 wireless small door sensor and window sensorHoneywell 5815 white wireless aesthetic door sensor and window s

There are also several great recessed contacts in the 5800 Series. The Honeywell 5818MNL is a relatively standard recessed contact that can be used with almost any door or window. It features a 200-foot range, and the installation only requires minor drilling. The Honeywell 5800Micra is a recessed contact for windows only. It is a very small sensor with an attached antenna for sending wireless signals. Finally there's the 5800RPS, which uses a plunger switch instead of a sensor and magnet. This sensor can only be used with doors. When the door is closed, the plunger switch will be pressed in. Once the door is opened, the plunger switch will come out and activate the sensor.

  • Honeywell 5818MNL - A standard recessed contact for doors and windows. It is easy to install, and it has a 200 foot range.
  • Honeywell 5800Micra - A small recessed contact for windows only. Its antenna must be adjusted carefully when installing.
  • Honeywell 5800RPS - A recessed sensor that uses a plunger switch instead of a magnet. For use with doors only.

Honeywell 5818mnl wireless recessed door sensor and window sensoHoneywell 5800micra wireless recessed window contact

Alarm Grid has previously discussed the batteries used with door sensors. We recommend checking out that blog post for more information on which batteries to use with a door and window sensor. If you ever need any additional help choosing a Honeywell door and window contact for your DIY wireless alarm system, please feel free to send an email to support@alarmgrid.com. You can also contact one of our technical specialists by calling 888-818-7728 from 9am to 8pm EST M-F.

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

Door alarm sensors, or contacts, are some of the most important devices used with security systems. These devices alert a user whenever their door is opened. They can be used on virtually any type of door. These might include a front door, a back door, screen doors, a patio door, a shed, cabinets and any door inside the building. We typically find that door alarm sensors are some of the easiest to use devices with an alarm system. But still, it can be helpful to read through a comprehensive guide explaining the full ins and outs of these devices. So it here is - everything you've ever to know about door alarm sensors.

Qolsys iq dw mini s encrypted wireless sensors for iq panel 2 qsThe Basics of Door Alarm Sensors

Most traditional door sensors feature a relatively simple design and premise. These devices usually consist of a sensor and a magnet. The sensor is placed on or inside the door frame, and the magnet is placed on or inside the door itself, within a half inch of the sensor. Opening the door will cause the magnet to pull away and separate from the sensor. When this happens, a reed switch inside the sensor will activate. This will cause the sensor to send a signal to the security system, letting it know that the door was opened. The system will then perform the appropriate response based on how the sensor's Response Type was programmed. At the surface, it's all very simple. Some examples of these traditional sensors include the Honeywell 5800MINI, the Honeywell SiXMINICT and the VERSA-2GIG Sensor. Traditional door sensors can be either surface-mounted or recessed.

Honeywell 5800mini interior wireless door and window sensor

There's also a second variation of door sensors, known as mechanical door sensors. This type of sensor features a physical switch that is pressed down when the door is closed. When the door is opened, the switch will pop up, causing the sensor to activate. From there, the system will perform the Response Type assigned to the zone for that sensor. This type of door alarm sensor is far less common than the other type of sensor. However, the end result is still the same - the system will still perform the programmed Response Type when the sensor is activated. An example of this type of sensor is the Honeywell 5800RPS. While you are less likely to come across this type of door sensor, it's still worth mentioning just in case. Mechanical door sensors are only available in the recessed variety.

Honeywell 5800rps wireless recessed door and window plunger sensTypes of Door Sensors - The Two Distinctions

Now that you know the very basics of door sensors, you can start thinking about the different types. While almost every door sensors operates using one of the two mechanisms mentioned above, there are two other distinctions that are commonly made between door sensors. These are whether the door sensor is wireless or wired and whether the door sensor is surface-mounted or recessed. These considerations will play a big role in determining which door sensor you choose to purchase for your alarm system.

A wireless door sensor will communicate with an alarm system wirelessly. This will prevent the need for running a wire from the system to the door sensor. This can make wireless door sensors significantly easier to install. Another great aspect of wireless door sensors is that they can usually be auto-enrolled with the security system. That said, a wireless sensor will need to have its battery replaced every three to five years. On the other hand, a wired door sensor will need to be physically connected with the alarm system. This can make the installation considerably more difficult in certain cases. However, a wired sensor will never require any battery replacements.

If you are using a wireless door sensor with a wired alarm system, such as a Honeywell VISTA Panel, then you will need to use a wireless receiver. This will allow the wireless signal to be received by the system. When choosing a wireless door sensor, make sure that the wireless frequencies it uses are compatible with your alarm system. For example, Honeywell Panels look for wireless signals that operate at a frequency of 345 MHz, while Qolsys Panels use signals that operate at a frequency of 319.5 MHz. If you try to use a wireless door sensor that does not communicate at the correct wireless frequency, then it will not function with the alarm system.

Honeywell 5800rp wireless repeaterThe other major distinction between door sensors is surface-mount sensors versus recessed sensors. Simply put, surface-mount sensors are installed on the outside of the door and its frame, while recessed sensors are installed in the inside. Surface-mount sensors require no drilling. In the easiest scenario, it is possible to mount them using a double-sided adhesive (foam tape). They can also be mounted using screws. With their easier installation, this is generally the preferred type of door sensor. Most users do not mind the fact that a small sensor will be visible on the outside of the door.

Honeywell 5820l super slim wireless door and window sensorHowever, for users who do want a more discrete installation, there are recessed door sensors. These sensors and their magnets need to be inserted into holes that are drilled into both the door and the frame. The exact size of the holes will depend on the specific model of the recessed door sensor that is being installed. Once the sensor and magnet have been installed, they will not be visible from the outside. That said, most users opt for surface-mount door sensors due to the easier installation.

Honeywell 5818mnl wireless recessed door sensor and window senso

Some Notes on Response Types

The primary function of any security sensor is determined by its Response Type. This refers to what action the system will take when the zone is faulted (e.g. the door is opened). Below are the Response Types that are most commonly used with door sensors:

  • Entry / Exit: If the door is opened while the system is armed stay or armed away, then the system will need to be disarmed within its entry delay period. If the system is not disarmed within this time period, then an alarm event will occur. Most alarms will feature two different Entry / Exit settings. This allows two different entry delay periods to be used on the same system for different zones.
  • Perimeter: If the door is opened while the system is armed stay or armed away, then an alarm event will occur immediately.
  • Interior Follower: If the system is set to armed away, an alarm event will immediately occur if the door is opened, assuming that an entry / exit zone is not faulted first. If an entry / exit zone is faulted first, then the system must be disarmed within its entry delay period, otherwise an alarm event will occur.
  • Interior With Delay: If the system is set to armed away and the door is opened, then the system must be disarmed within its entry delay period. If the system is not disarmed within this time period, then an alarm event will occur.
  • Day / Night: If the system is disarmed and the door is opened, a trouble event will occur on the system. If the system is armed away or armed stay and the door is opened, an alarm event will immediately occur on the system.
  • 24 Hour Audible: Opening the door will immediately cause a full system siren and an alarm to be set off, regardless of what state the system is currently in. This Response Type should not be used unless the door should never be opened for any reason.
  • 24 Hour Auxiliary: Same as 24 Hour Audible, but only the panel itself will produce a siren. Any external sirens or noisemakers will not activate. This zone type is ideal for emergency medical cabinets that would only be opened in a serious medical emergency.
  • 24 Hour Silent: Same as 24 Hour Audible, but no siren or sound will be produced.
  • Fire No Verification: Opening the door will immediately cause a fire alarm to be set off, regardless of what state the system is currently in. This is the ideal Response Type for fire doors.

Certain Response Types are only available for certain Device Types. Depending upon the panel you are using, not all of these Response Types will be made available for the Device Type of "Door". A way to work around this is to set the Device Type to "Other". This will allow you to set any possible Response Type for the door sensor.

2gig dw10 wireless slim door slash window contactOther Programming Settings

Programming a door sensor has to do with more than just the Response Type and the Device Type. Below are some of the other programming settings available for a door sensor. Please note that these settings are specific for a Honeywell Lyric Controller, and different settings may be available on another type of panel.

  • Serial Number: This is how the system will specifically identify the exact door sensor that is being used.
  • Loop Number: This tells the door sensor what function it should perform. Each door sensor usually has a specific loop number that should be set for the device to function as a door sensor. Some door sensors have multiple possible functions that can be used with the device. One example is the Honeywell 5816, which can be used as both a door sensor and as a wireless transmitter depending upon the loop number that is set.
  • Zone Descriptors: These serve as the name of the door sensor. The panel will announce the zone descriptors whenever the zone for that sensor is affected.
  • Alarm Report: This tells the system whether or not it should send an outbound signal to the central monitoring station. If you turn this off, then all the sounds and sirens will still be made, but a distress signal will never be sent to the central station. An example for turning this off might be if you are monitoring a liquor cabinet to make sure your teenage doesn't get into it. You might want a very loud siren to go off so that you know if this happens. However, you obviously wouldn't want the police to show up at your house in this situation!
  • Chime: This will have the panel produce a simple chime whenever the door is opened. Many panels will allow you to toggle between different chime options for the panel. Remember, you will still need to have the local chime for the system enabled from the main settings menu.
  • Supervision: This will have the system monitor the door sensor for low battery or loss of signal. Keep this enabled to make sure that the door sensor is always in proper working order. This setting is only used with wireless door sensors.

For any programming questions related to a specific panel, please consult the programming guide for that panel. This information is readily available on the Alarm Grid website in the form of FAQs.

Honeywell 5816 wireless door window sensor

Common Door Sensor Questions

Below are some questions that are commonly asked about door sensors:

1. How do I program my door sensor?

If it is a wireless door sensor, it can most likely be auto-enrolled.This is accomplished by accessing zone programming on the system and then faulting and restoring the door sensor three times to learn it in. You can fault and restore the door sensor by separating the sensor and the magnet and then clicking them back together. From there, make any necessary programming configurations on the panel. See the above information on Response Types and other programming settings.

If it is a wired door sensor with a hardwired VISTA Panel, then we recommend consulting this FAQ. You may also need to consult the VISTA 15P and 20P Programming Guide.

Honeywell vista 15p alarm control panel

2. How long do door sensor batteries last?

A wireless door sensor will typically require a battery replacement every three to five years. Wired door sensors do not use batteries, and they will never require a battery replacement.

Panasonic cr123a 3v battery

3. How close should the door sensor be to its magnet?

We usually recommend placing the door sensor magnet within a half inch of the sensor. Some sensors may allow for a greater separation distance than others before a faulted zone will occur. The closer the magnet is to the sensor, the less likely an unwanted fault or a false alarm is to occur.

Honeywell 5899 magnet for 5816 wireless door sensor and window s

4. Are there any encrypted wireless door sensors?

Yes, there are encrypted wireless door sensors. The Honeywell SiXCT, the Honeywell SiXMINICT, the Qolsys IQ DW MINI-S and the Qolsys IQ Recessed Door-S are all encrypted wireless door sensors.

Honeywell sixct wireless door slash window contact for lyric con

5. What is the best door sensor?

Please see the following FAQs:

Tags: , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments