Last week, we took a look at three of the best alarm panels in the industry. These were the Honeywell Lyric, the Qolsys IQ Panel 2 Plus, and the 2GIG GC3e. Today, we are checking out the sensors that you can add to support these systems. Here is our 2020 Security Sensor Buying Guide!

Sensors are accessories that are added to alarm systems to report specific activity. Each sensor has its own job of looking for a certain type of activity in its designated location. All of the sensors on a system communicate with a single centralized panel or hub. This panel is actively listening for any sensor that is triggered due to a potentially important system event. Adding new sensors is perhaps the best way to expand upon an existing system, and they make awesome gifts and stocking stuffers for the security enthusiast in your life.

Broadly speaking, sensors can be split into two main categories, which are security and life safety/environmental. Security sensors look for activity that suggests potentially unauthorized entry into a monitored and protected location, such as a door being opened, movement in a room where nobody is supposed to be present, or a window being broken. Life safety/environmental sensors look for activity associated with unwanted or potentially harmful conditions that affect the well-being of those in the area, such as a flood, an extreme temperature, a fire, or the presence of CO gas. We'll be taking a look at life safety/environmental sensors another time. Today, our focus is on security sensors.

Wireless Sensor Basics


Before we dive into specific security sensors for our top panel picks, we're going to start by giving you some general, generic information that can be applied to any sensor out there. First, understand that this post is focusing only on wireless sensors. These are almost always the sensors chosen for use with wireless alarm systems. Wired sensors can also technically be used with wireless panels but a converter module is almost always needed. Not to mention the fact that wireless sensors are significantly easier to install, especially for DIY users. The only time you will realistically see wired sensors used with a wireless panel is if a user is upgrading from an older wired system and bringing over their old wired sensors, or in new construction where a user wants to integrate the sensors in with the building. But if you're expanding upon a wireless system by getting new sensors, then the new sensors will almost certainly be wireless.

The important thing to remember when choosing wireless sensors for a wireless alarm panel is making sure the sensor is compatible with the system. It doesn't matter if a sensor has all the specs and features if it doesn't work with your panel! The way to determine compatibility is to look at the lineup that the sensor is from. Petty much every wireless sensor out there is part of a larger grouping of sensors that will all have the same compatibility.

To make it easier for you, we have the three panels we mentioned before (well, make that five, as the Qolsys IQ Panel 2 Plus actually comes in three versions), and all their compatible sensor lineups conveniently listed. We hope that this sheds some light on your options. The only caveat is that for any panel listed here that supports the Honeywell 5800 Sensors, we must be clear that this is only for the uni-directional sensors with one-way communication in the lineup. Any bi-directional Honeywell 5800 Sensors with two-way communication will not work with any of the aforementioned systems. The bi-directional Honeywell 5800 Sensors are only compatible with the Honeywell LYNX Touch and VISTA Systems, which were not included in our buying guides.

With that out of the way, here are compatible sensor lineups by system:

You will notice that some of the sensor groups listed above are italicized and underlined. That is done to identify the lineups of encrypted sensors. These encrypted sensors have special protection measures put in place to make them more secure and less prone to being hacked or defeated by malicious attacks. Encrypted sensors tend to have more restricted compatibility. They may follow a special enrollment process. Encrypted sensors often use bi-directional communication so that the sensor knows that it is actively paired with the system. Many encrypted sensors may only be paired with a single system at any given time, and the sensor will need to be deleted from its existing system before it will work with a new one.

It's okay to use non-encrypted sensors with your system, especially in zones that are less likely to trigger an alarm, like a second story window. Many users will opt to use a mixture of both encrypted and non-encrypted sensors. Other users feel comfortable using entirely non-encrypted sensors. It really comes down to your level of comfort. Non-encrypted sensors are secure in most situations, and they are still tricky to defeat. But going fully encrypted is recommended for anyone seeking maximum security. One tip if you do decide to go with some non-encrypted sensors is to avoid letting others know what wireless frequency your sensors use or what type of system you have installed. Knowing the frequency and the system being used makes it much easier for a savvy intruder to defeat a sensor.

Door & Window Alarm Sensors


Now that you know some basics that apply to almost all wireless sensors, let's start talking about specific types and models. Door and window sensors will let a system know when a door or window has been opened or closed. These are some of the most basic and easy to use sensors on a security system. These devices work by using a larger sensor portion and a smaller magnet portion. The sensor is placed on or inside the door or window frame, and the magnet is placed on or inside the moving portion of the door or window. When the door or window is opened, the magnet will move away from the sensor. This will trip a metal reed switch inside the sensor, which will tell the sensor to alert the system to the opened door or window. All of the sensors we've listed here follow that same method of operation.

Door and window sensors can be split into two (2) main categories. Surface-mount door and window sensors are mounted outside the door or window and its accompanying frame on the surface. The advantage to surface-mount door and window sensors is that they are very easy to install, and they can usually be mounted using double sided foam tape. But some users may not like how they are visible on the outside of the door or window. If you don't like the appearance of visible surface-mount door and window sensors, then you might instead consider recessed door and window sensors. A recessed door or window sensor is installed inside a door or window and its frame, so that it is hidden and cannot be seen from the outside. Recessed door and window sensors are more difficult and time-consuming to install, because you must drill holes in both the door or window and its accompanying frame. Whether you decide to use surface-mount door and window sensors, or recessed door and window sensors is up to you. Most DIY users and Alarm Grid customers in general will use surface-mount door and window sensors.

Now let's look at some door and window sensors.:

Sensor Name
Product Lineup
Compatibility Range
Encryption Installation
Notes
Honeywell SiXMINICT

Honeywell SiX Series Lyric 200 Nominal Feet 128-bit AES Surface-Mount Premier mini encrypted door/window Sensor for Lyric.
DSC PG9303

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Surface-Mount PowerG encrypted surface mount door/window sensor.
DSC PG9307

PowerG All IQ Panel 2 Plus
2,000 Feet Open Air 128-bit AES Recessed PowerG encrypted recessed door/window sensor.
2GIG DW10e

2GIG eSeries 2GIG GC3e 350 Nominal Feet 2GIG eSeries Encryption Surface-Mount Encrypted surface-mount sensor for 2GIG
2GIG DW20e

2GIG eSeries
2GIG GC3e
350 Nominal Feet 2GIG eSeries Encryption
Recessed Encrypted recessed sensor for 2GIG
Qolsys IQ DW Mini-S

Qolsys S-Line 319.5 MHz IQ2+ 600 Feet Open Air Qolsys S-Line Encryption Surface-Mount Encrypted surface-mount sensor for 319.5 MHz systems.
Qolsys IQ Recessed Door-S

Qolsys S-Line 319.5 MHz IQ 2+ 600 Feet Open Air Qolsys S-Line Encryption Recessed Encrypted recessed sensor for 319.5 MHz systems.
Honeywell 5818MNL

Honeywell
5800 Series
Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Recessed Non-Encrypted recessed door/window sensor for 345 MHz systems.
VERSA-2GIG

2GIG 345 MHz Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Surface-Mount Non-encrypted surface-mount sensor for 345 MHz systems.
VERSA-GE

Legacy GE 319.5 MHz IQ2+ 200 Nominal Feet None Surface-Mount Non-encrypted surface-mount sensor for 319.5 MHz systems.
VERSA-DSC

Legacy DSC 433 MHz IQ2+ 200 Nominal Feet None Surface-Mount Non-encrypted surface-mount sensor for 433 MHz systems.

We also want to share a selection of outdoor door and window sensors with you. These surface-mount contact sensors are specifically designed to withstand the conditions of an outdoor environment, including intense rain, wind, dust, and sunlight. You can see them listed below.

Sensor Name
Product Lineup
Compatibility
Range
Encryption
Installation Notes
Honeywell 5816OD

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Surface-Mount Outdoor contact sensor from 5800 Series.
DSC PG9312

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Surface-Mount PowerG Outdoor Contact Sensor.
2GIG DW30-345

2GIG 345 MHz Lyric, GC3e, 345 MHz IQ2+ 350 Nominal Feet None Surface-Mount Outdoor contact sensor from 2GIG 345 MHz series.

Motion Sensors


Motion sensors use passive infrared (PIR) technology to detect movement within the sensor's coverage area. This is done by looking for the changes in infrared (IR) energy that occur when a person, animal, or object comes within the sensor's field of view. Standard motion sensors are typically PIR only. These are appropriately called PIR motion sensors.

Some motion sensors will also use microwave technology in addition to PIR technology. This involves having the sensor send out microwave signals and seeing how the signals bounce off of objects in the area. Movement will change the pattern of these microwave signals, and the sensor will be able to detect this. These motion sensors that use both microwave and PIR are called Dual-Tech motion sensors. The purpose of using both PIR and microwave together is to prevent false alarms. A Dual-Tech motion sensor will only activate and alert the system if both its PIR sensor and its microwave sensor are triggered. A microwave sensor is not vulnerable to the same environmental issues that may cause a false activation on a PIR. You will not find a motion sensor that uses microwave technology without PIR detection, as microwave alone would result in too many false alarms without having PIR to confirm movement.

One feature that you will often see listed on a motion sensor is pet-immunity. A motion sensor that has been set up for pet immunity can be configured to not "look" in the areas close to the ground where pets and small animals walk. Instead, the motion sensor only looks in the areas higher up, where humans move while walking upright. A pet immune motion sensor is not impervious to small animals, and you must position it carefully so that it works as intended. Pet immune motion sensors normally have a weight limit, where animals under that weight limit should avoid triggering the sensor, assuming that the sensor is installed properly. Please note that most pet friendly motion sensors will require you to set the sensitivity for the sensor to the lowest possible setting.

When it comes to motion sensors, mounting them carefully is very important. A motion sensor may cause false alarms on the system if it is not installed properly. These sensors should not be facing any vents, air ducts, ceiling fans, or curtains that may cause the sensor to activate without any movement. If you are using the motion sensor for pet immunity, then it should also not be facing any furniture or stairwells that your pet could use to get within the sensor's field of view. You will likely want to perform a Walk Test of your motion sensor to make sure that it responds properly when movement is present, and does not respond due to other external factors when there is no movement. You should also have any pets participate in the Walk Test to ensure that pet immunity is working properly.

We recommend reading the following FAQs to learn more about motion sensors:

Below are some of the most popular motion sensors for our recommended systems:

Sensor Name Product Lineup
Compatibility Range
Encryption Coverage Area
Detection Type
Pet Immunity Notes
Honeywell SiXPIR

Honeywell SiX Series Lyric 300 Nominal Feet 128-bit AES 40 by 56 Feet
PIR Up to 80 lbs Encrypted PIR Motion for Lyric.
DSC PG9914

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Up to 39 Feet PIR Up to 85 lbs PowerG Encrypted PIR Motion.
DSC PG9984P

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Up to 50 Feet Dual-Tech Up to 40 lbs PowerG Encrypted Dual-Tech Motion.
2GIG PIR1e

2GIG eSeries 2GIG GC3e 350 Nominal Feet 2GIG eSeries Encryption
30 by 50 Feet PIR Up to 55 lbs Encrypted PIR Motion for 2GIG.
Honeywell 5800PIR-RES

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None 35 by 40 Feet PIR Up to 80 lbs Non-encrypted residential PIR motion for 345 MHz systems.
Honeywell 5800PIR-COM

Honeywell 5800 Series Lyric, GC3e, 345 MHz, IQ2+ 200 Nominal Feet None 60 by 80 Feet PIR None Non-encrypted commercial PIR motion for 345 MHz systems.
Honeywell 5898

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None 35 by 40 Feet for Pet Immunity Dual-Tech Up to 100 lbs Non-encrypted Dual-Tech motion for 345 MHz systems.
Qolsys IQ Motion-S

Qolsys S-Line 319.5 MHz IQ2+ 600 Feet Open Air Qolsys S-Line Encryption 30 by 40 Feet PIR Up to 40 lbs Non-encrypted PIR motion for 319.5 MHz systems.

There are also certain outdoor motion detection sensors that are better-suited for use in an outdoor environment. These outdoor motion sensor models are typically more expensive than indoor variants. You can see some of our most popular ones listed below:

Sensor Name
Product Lineup
Compatibility Range
Encryption Coverage Area
Detection Type
Pet Immunity Notes
DSC PG9994

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Up to 30 Feet PIR Up to 40 lbs PowerG Outdoor PIR Motion Sensor
Honeywell 5800PIR-OD

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None 40 by 30 Feet PIR None Honeywell 5800 Series Outdoor Motion, 1st ed.
Honeywell 5800PIR-OD2

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None 40 by 30 Feet PIR None Honeywell 5800 Series Outdoor Motion, 2nd ed.
Optex FTN-RRIX

Legacy Interlogix 319.5 MHz IQ2+ 200 Nominal Feet None Up to 16.5 Feet PIR None Optex Fitlink Outdoor Motion Sensor for 319.5 MHz Systems
Optex FTN-RR2G

2GIG 345 MHz Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Up to 16.5 Feet PIR None Optex Fitlink Outdoor Motion Sensor for 345 MHz Systems.
Optex FTN-RRDS

Legacy DSC 433 MHz IQ2+ 200 Nominal Feet None Up to 16.5 Feet PIR None Optex Fitlink Outdoor Motion Sensor for 433 MHz Systems.

Glass Break Sensors

The last type of security sensors we will be discussing are glass break sensors. These sensors include built-in microphones, and they actively listen for the unique sound of glass breaking. Most of these sensors will need to hear both the high-pitched shattering sound of the glass breaking, as well as the low-pitched sound of an object striking against the glass in order to activate. This design choice is to prevent false alarms caused by similar sounds. Most users will use glass break sensors to monitor windows, but they have also been known to work effectively on protective glass display cases that store valuables, such as what you might find in jewelry stores or gun shops. Most types of glass will work with glass break sensors, though there are some exceptions. For example double and triple pane glass windows won't work reliably. The same is true for coated or "safety" glass. Refer to the manual for the exact glass break detector you are using to determine compatibility.

A single glass break detector can monitor multiple windows or display cases, as long as the glass it is monitoring is within its detection range, which is typically 15 to 25 feet. Any glass that is being monitored must have a direct line of sight with the sensor, with no obstacles blocking the path that sound will travel through. When testing your glass break sensors, it is strongly recommended that you us a glass break simulator. These devices will mimic the sound of the glass breaking and activate your glass break sensors without actually breaking any glass. Remember to refer the instructions of your glass break simulator for more information. When choosing a glass break simulator, it is best to use a simulator from the same manufacturer, if possible. We have a Honeywell Glass Break Simulator and a DSC Glass Break Simulator available on our website. If you get one of the 2GIG Glass Break Sensors mentioned in this buying guide, then the Honeywell Glass Break Simulator is best for testing. Otherwise, just match the manufacturer.

Below are some of our most popular glass break sensors:

Sensor Name
Product Lineup
Compatibility
Range
Encryption
Notes
Honeywell SiXGB

Honeywell SiX Series Lyric 300 Nominal Feet 128-bit AES SiX Series Glass Break Sensor for Lyric
DSC PG922

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES PowerG Glass Break Sensor
2GIG GB1e

2GIG eSeries 2GIG GC3e 350 Nominal Feet 2GIG eSeries Encryption Encrypted glass break sensor for 2GIG.
Honeywell 5853

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Non-encrypted glass break sensor for 345 MHz systems.
Qolsys IQ Glass-S

Qolsys S-Line 319.5 MHz IQ2+ 600 Feet Open Air Qolsys S-Line Encryption Encrypted glass break sensor for 319.5 MHz systems.

Reach Out to Us!


Remember that you can reach out to us with any questions you might have about planning your system and determining sensor compatibility. The best way to contact us is to email support@alarmgrid.com. This is also a good email to use if you are interested in starting new alarm monitoring service with Alarm Grid. Our team checks for new email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

Last week, we took a look at three of the best alarm panels in the industry. These were the Honeywell Lyric, the Qolsys IQ Panel 2 Plus, and the 2GIG GC3e. Today, we are checking out the sensors that you can add to support these systems. Here is our 2020 Security Sensor Buying Guide!

Sensors are accessories that are added to alarm systems to report specific activity. Each sensor has its own job of looking for a certain type of activity in its designated location. All of the sensors on a system communicate with a single centralized panel or hub. This panel is actively listening for any sensor that is triggered due to a potentially important system event. Adding new sensors is perhaps the best way to expand upon an existing system, and they make awesome gifts and stocking stuffers for the security enthusiast in your life.

Broadly speaking, sensors can be split into two main categories, which are security and life safety/environmental. Security sensors look for activity that suggests potentially unauthorized entry into a monitored and protected location, such as a door being opened, movement in a room where nobody is supposed to be present, or a window being broken. Life safety/environmental sensors look for activity associated with unwanted or potentially harmful conditions that affect the well-being of those in the area, such as a flood, an extreme temperature, a fire, or the presence of CO gas. We'll be taking a look at life safety/environmental sensors another time. Today, our focus is on security sensors.

Wireless Sensor Basics


Before we dive into specific security sensors for our top panel picks, we're going to start by giving you some general, generic information that can be applied to any sensor out there. First, understand that this post is focusing only on wireless sensors. These are almost always the sensors chosen for use with wireless alarm systems. Wired sensors can also technically be used with wireless panels but a converter module is almost always needed. Not to mention the fact that wireless sensors are significantly easier to install, especially for DIY users. The only time you will realistically see wired sensors used with a wireless panel is if a user is upgrading from an older wired system and bringing over their old wired sensors, or in new construction where a user wants to integrate the sensors in with the building. But if you're expanding upon a wireless system by getting new sensors, then the new sensors will almost certainly be wireless.

The important thing to remember when choosing wireless sensors for a wireless alarm panel is making sure the sensor is compatible with the system. It doesn't matter if a sensor has all the specs and features if it doesn't work with your panel! The way to determine compatibility is to look at the lineup that the sensor is from. Petty much every wireless sensor out there is part of a larger grouping of sensors that will all have the same compatibility.

To make it easier for you, we have the three panels we mentioned before (well, make that five, as the Qolsys IQ Panel 2 Plus actually comes in three versions), and all their compatible sensor lineups conveniently listed. We hope that this sheds some light on your options. The only caveat is that for any panel listed here that supports the Honeywell 5800 Sensors, we must be clear that this is only for the uni-directional sensors with one-way communication in the lineup. Any bi-directional Honeywell 5800 Sensors with two-way communication will not work with any of the aforementioned systems. The bi-directional Honeywell 5800 Sensors are only compatible with the Honeywell LYNX Touch and VISTA Systems, which were not included in our buying guides.

With that out of the way, here are compatible sensor lineups by system:

You will notice that some of the sensor groups listed above are italicized and underlined. That is done to identify the lineups of encrypted sensors. These encrypted sensors have special protection measures put in place to make them more secure and less prone to being hacked or defeated by malicious attacks. Encrypted sensors tend to have more restricted compatibility. They may follow a special enrollment process. Encrypted sensors often use bi-directional communication so that the sensor knows that it is actively paired with the system. Many encrypted sensors may only be paired with a single system at any given time, and the sensor will need to be deleted from its existing system before it will work with a new one.

It's okay to use non-encrypted sensors with your system, especially in zones that are less likely to trigger an alarm, like a second story window. Many users will opt to use a mixture of both encrypted and non-encrypted sensors. Other users feel comfortable using entirely non-encrypted sensors. It really comes down to your level of comfort. Non-encrypted sensors are secure in most situations, and they are still tricky to defeat. But going fully encrypted is recommended for anyone seeking maximum security. One tip if you do decide to go with some non-encrypted sensors is to avoid letting others know what wireless frequency your sensors use or what type of system you have installed. Knowing the frequency and the system being used makes it much easier for a savvy intruder to defeat a sensor.

Door & Window Alarm Sensors


Now that you know some basics that apply to almost all wireless sensors, let's start talking about specific types and models. Door and window sensors will let a system know when a door or window has been opened or closed. These are some of the most basic and easy to use sensors on a security system. These devices work by using a larger sensor portion and a smaller magnet portion. The sensor is placed on or inside the door or window frame, and the magnet is placed on or inside the moving portion of the door or window. When the door or window is opened, the magnet will move away from the sensor. This will trip a metal reed switch inside the sensor, which will tell the sensor to alert the system to the opened door or window. All of the sensors we've listed here follow that same method of operation.

Door and window sensors can be split into two (2) main categories. Surface-mount door and window sensors are mounted outside the door or window and its accompanying frame on the surface. The advantage to surface-mount door and window sensors is that they are very easy to install, and they can usually be mounted using double sided foam tape. But some users may not like how they are visible on the outside of the door or window. If you don't like the appearance of visible surface-mount door and window sensors, then you might instead consider recessed door and window sensors. A recessed door or window sensor is installed inside a door or window and its frame, so that it is hidden and cannot be seen from the outside. Recessed door and window sensors are more difficult and time-consuming to install, because you must drill holes in both the door or window and its accompanying frame. Whether you decide to use surface-mount door and window sensors, or recessed door and window sensors is up to you. Most DIY users and Alarm Grid customers in general will use surface-mount door and window sensors.

Now let's look at some door and window sensors.:

Sensor Name
Product Lineup
Compatibility Range
Encryption Installation
Notes
Honeywell SiXMINICT

Honeywell SiX Series Lyric 200 Nominal Feet 128-bit AES Surface-Mount Premier mini encrypted door/window Sensor for Lyric.
DSC PG9303

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Surface-Mount PowerG encrypted surface mount door/window sensor.
DSC PG9307

PowerG All IQ Panel 2 Plus
2,000 Feet Open Air 128-bit AES Recessed PowerG encrypted recessed door/window sensor.
2GIG DW10e

2GIG eSeries 2GIG GC3e 350 Nominal Feet 2GIG eSeries Encryption Surface-Mount Encrypted surface-mount sensor for 2GIG
2GIG DW20e

2GIG eSeries
2GIG GC3e
350 Nominal Feet 2GIG eSeries Encryption
Recessed Encrypted recessed sensor for 2GIG
Qolsys IQ DW Mini-S

Qolsys S-Line 319.5 MHz IQ2+ 600 Feet Open Air Qolsys S-Line Encryption Surface-Mount Encrypted surface-mount sensor for 319.5 MHz systems.
Qolsys IQ Recessed Door-S

Qolsys S-Line 319.5 MHz IQ 2+ 600 Feet Open Air Qolsys S-Line Encryption Recessed Encrypted recessed sensor for 319.5 MHz systems.
Honeywell 5818MNL

Honeywell
5800 Series
Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Recessed Non-Encrypted recessed door/window sensor for 345 MHz systems.
VERSA-2GIG

2GIG 345 MHz Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Surface-Mount Non-encrypted surface-mount sensor for 345 MHz systems.
VERSA-GE

Legacy GE 319.5 MHz IQ2+ 200 Nominal Feet None Surface-Mount Non-encrypted surface-mount sensor for 319.5 MHz systems.
VERSA-DSC

Legacy DSC 433 MHz IQ2+ 200 Nominal Feet None Surface-Mount Non-encrypted surface-mount sensor for 433 MHz systems.

We also want to share a selection of outdoor door and window sensors with you. These surface-mount contact sensors are specifically designed to withstand the conditions of an outdoor environment, including intense rain, wind, dust, and sunlight. You can see them listed below.

Sensor Name
Product Lineup
Compatibility
Range
Encryption
Installation Notes
Honeywell 5816OD

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Surface-Mount Outdoor contact sensor from 5800 Series.
DSC PG9312

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Surface-Mount PowerG Outdoor Contact Sensor.
2GIG DW30-345

2GIG 345 MHz Lyric, GC3e, 345 MHz IQ2+ 350 Nominal Feet None Surface-Mount Outdoor contact sensor from 2GIG 345 MHz series.

Motion Sensors


Motion sensors use passive infrared (PIR) technology to detect movement within the sensor's coverage area. This is done by looking for the changes in infrared (IR) energy that occur when a person, animal, or object comes within the sensor's field of view. Standard motion sensors are typically PIR only. These are appropriately called PIR motion sensors.

Some motion sensors will also use microwave technology in addition to PIR technology. This involves having the sensor send out microwave signals and seeing how the signals bounce off of objects in the area. Movement will change the pattern of these microwave signals, and the sensor will be able to detect this. These motion sensors that use both microwave and PIR are called Dual-Tech motion sensors. The purpose of using both PIR and microwave together is to prevent false alarms. A Dual-Tech motion sensor will only activate and alert the system if both its PIR sensor and its microwave sensor are triggered. A microwave sensor is not vulnerable to the same environmental issues that may cause a false activation on a PIR. You will not find a motion sensor that uses microwave technology without PIR detection, as microwave alone would result in too many false alarms without having PIR to confirm movement.

One feature that you will often see listed on a motion sensor is pet-immunity. A motion sensor that has been set up for pet immunity can be configured to not "look" in the areas close to the ground where pets and small animals walk. Instead, the motion sensor only looks in the areas higher up, where humans move while walking upright. A pet immune motion sensor is not impervious to small animals, and you must position it carefully so that it works as intended. Pet immune motion sensors normally have a weight limit, where animals under that weight limit should avoid triggering the sensor, assuming that the sensor is installed properly. Please note that most pet friendly motion sensors will require you to set the sensitivity for the sensor to the lowest possible setting.

When it comes to motion sensors, mounting them carefully is very important. A motion sensor may cause false alarms on the system if it is not installed properly. These sensors should not be facing any vents, air ducts, ceiling fans, or curtains that may cause the sensor to activate without any movement. If you are using the motion sensor for pet immunity, then it should also not be facing any furniture or stairwells that your pet could use to get within the sensor's field of view. You will likely want to perform a Walk Test of your motion sensor to make sure that it responds properly when movement is present, and does not respond due to other external factors when there is no movement. You should also have any pets participate in the Walk Test to ensure that pet immunity is working properly.

We recommend reading the following FAQs to learn more about motion sensors:

Below are some of the most popular motion sensors for our recommended systems:

Sensor Name Product Lineup
Compatibility Range
Encryption Coverage Area
Detection Type
Pet Immunity Notes
Honeywell SiXPIR

Honeywell SiX Series Lyric 300 Nominal Feet 128-bit AES 40 by 56 Feet
PIR Up to 80 lbs Encrypted PIR Motion for Lyric.
DSC PG9914

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Up to 39 Feet PIR Up to 85 lbs PowerG Encrypted PIR Motion.
DSC PG9984P

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Up to 50 Feet Dual-Tech Up to 40 lbs PowerG Encrypted Dual-Tech Motion.
2GIG PIR1e

2GIG eSeries 2GIG GC3e 350 Nominal Feet 2GIG eSeries Encryption
30 by 50 Feet PIR Up to 55 lbs Encrypted PIR Motion for 2GIG.
Honeywell 5800PIR-RES

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None 35 by 40 Feet PIR Up to 80 lbs Non-encrypted residential PIR motion for 345 MHz systems.
Honeywell 5800PIR-COM

Honeywell 5800 Series Lyric, GC3e, 345 MHz, IQ2+ 200 Nominal Feet None 60 by 80 Feet PIR None Non-encrypted commercial PIR motion for 345 MHz systems.
Honeywell 5898

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None 35 by 40 Feet for Pet Immunity Dual-Tech Up to 100 lbs Non-encrypted Dual-Tech motion for 345 MHz systems.
Qolsys IQ Motion-S

Qolsys S-Line 319.5 MHz IQ2+ 600 Feet Open Air Qolsys S-Line Encryption 30 by 40 Feet PIR Up to 40 lbs Non-encrypted PIR motion for 319.5 MHz systems.

There are also certain outdoor motion detection sensors that are better-suited for use in an outdoor environment. These outdoor motion sensor models are typically more expensive than indoor variants. You can see some of our most popular ones listed below:

Sensor Name
Product Lineup
Compatibility Range
Encryption Coverage Area
Detection Type
Pet Immunity Notes
DSC PG9994

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Up to 30 Feet PIR Up to 40 lbs PowerG Outdoor PIR Motion Sensor
Honeywell 5800PIR-OD

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None 40 by 30 Feet PIR None Honeywell 5800 Series Outdoor Motion, 1st ed.
Honeywell 5800PIR-OD2

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None 40 by 30 Feet PIR None Honeywell 5800 Series Outdoor Motion, 2nd ed.
Optex FTN-RRIX

Legacy Interlogix 319.5 MHz IQ2+ 200 Nominal Feet None Up to 16.5 Feet PIR None Optex Fitlink Outdoor Motion Sensor for 319.5 MHz Systems
Optex FTN-RR2G

2GIG 345 MHz Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Up to 16.5 Feet PIR None Optex Fitlink Outdoor Motion Sensor for 345 MHz Systems.
Optex FTN-RRDS

Legacy DSC 433 MHz IQ2+ 200 Nominal Feet None Up to 16.5 Feet PIR None Optex Fitlink Outdoor Motion Sensor for 433 MHz Systems.

Glass Break Sensors

The last type of security sensors we will be discussing are glass break sensors. These sensors include built-in microphones, and they actively listen for the unique sound of glass breaking. Most of these sensors will need to hear both the high-pitched shattering sound of the glass breaking, as well as the low-pitched sound of an object striking against the glass in order to activate. This design choice is to prevent false alarms caused by similar sounds. Most users will use glass break sensors to monitor windows, but they have also been known to work effectively on protective glass display cases that store valuables, such as what you might find in jewelry stores or gun shops. Most types of glass will work with glass break sensors, though there are some exceptions. For example double and triple pane glass windows won't work reliably. The same is true for coated or "safety" glass. Refer to the manual for the exact glass break detector you are using to determine compatibility.

A single glass break detector can monitor multiple windows or display cases, as long as the glass it is monitoring is within its detection range, which is typically 15 to 25 feet. Any glass that is being monitored must have a direct line of sight with the sensor, with no obstacles blocking the path that sound will travel through. When testing your glass break sensors, it is strongly recommended that you us a glass break simulator. These devices will mimic the sound of the glass breaking and activate your glass break sensors without actually breaking any glass. Remember to refer the instructions of your glass break simulator for more information. When choosing a glass break simulator, it is best to use a simulator from the same manufacturer, if possible. We have a Honeywell Glass Break Simulator and a DSC Glass Break Simulator available on our website. If you get one of the 2GIG Glass Break Sensors mentioned in this buying guide, then the Honeywell Glass Break Simulator is best for testing. Otherwise, just match the manufacturer.

Below are some of our most popular glass break sensors:

Sensor Name
Product Lineup
Compatibility
Range
Encryption
Notes
Honeywell SiXGB

Honeywell SiX Series Lyric 300 Nominal Feet 128-bit AES SiX Series Glass Break Sensor for Lyric
DSC PG922

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES PowerG Glass Break Sensor
2GIG GB1e

2GIG eSeries 2GIG GC3e 350 Nominal Feet 2GIG eSeries Encryption Encrypted glass break sensor for 2GIG.
Honeywell 5853

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Non-encrypted glass break sensor for 345 MHz systems.
Qolsys IQ Glass-S

Qolsys S-Line 319.5 MHz IQ2+ 600 Feet Open Air Qolsys S-Line Encryption Encrypted glass break sensor for 319.5 MHz systems.

Reach Out to Us!


Remember that you can reach out to us with any questions you might have about planning your system and determining sensor compatibility. The best way to contact us is to email support@alarmgrid.com. This is also a good email to use if you are interested in starting new alarm monitoring service with Alarm Grid. Our team checks for new email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

If you are looking for a wireless sensor solution that comes fully integrated into a door or window, then Andersen Doors and Windows might be for you. There are many Andersen Doors and Windows that come with integrated 345 MHz wireless sensors for using with a compatible alarm system.

Qolsys iq panel 2 plus verizon lte with powerg and legacy honeyw

The wireless sensors that come built into Andersen Doors and Windows are commonly referred to as Andersen Verilock Sensors. For a complete list of Andersen Doors and Windows that utilize these integrated sensors, please see this FAQ as a reference. While we are specifically using this post to highlight the compatibility between the Andersen Verilock Sensors and the 345 MHz Qolsys IQ Panel 2 Plus, there is no reason why you couldn't also use these sensors with a different 345 MHz system, like the Honeywell Lyric or one of the Honeywell LYNX Touch Panels.

The 345 MHz Qolsys IQ Panel 2 Plus serves as a great system for the integrated Andersen Door and Window Sensors, specifically due to the fact that the IQ2+ supports a large number of wireless zones (up to 128). This is important because each Andersen Verilock Sensor will typically use two (2) wireless zones for full system operation. One zone (Loop 1) will monitor for the door or window being opened/closed. The other zone (Loop 2) will monitor for the door or window being locked/unlocked. These sensors have a wireless range of roughly 500 feet when used in an open air environment. Remember that obstacles like thick walls and large metal objects can reduce wireless range.


One very important thing to note about Andersen products is that they are typically only sold through licensed Andersen dealers. Alarm Grid cannot sell these sensors directly. Also, Andersen mandates in its terms of service that their integrated door and window sensors only be installed by professional installers who are certified and approved by Andersen. Failure to comply with the Andersen terms of service can result in the warranty for your door or window being terminated. It is strongly advised that you visit the Andersen website and contact a dealer in your area if you are serious about installing these doors and/or windows.

While Andersen does have strict policies regarding the sale and installation of their integrated sensors, they also have an extensive YouTube Channel with lots of informational and how-to videos involving their products. It is truly a great resource for everyone from the DIY weekend warrior looking to complete their own installation, to the professional installer certified by Andersen. We posted a general informational video from Andersen above, but there are plenty more to check out if you are hoping to learn more about these products.

The best complement for Andersen Security Doors and Windows is alarm monitoring service. And that is a job for Alarm Grid! We offer monitoring plans for all needs and budgets so that you can have an automatic response if your Andersen Door or Window detects activity. If you are hoping to get started with Alarm Grid monitoring service, feel free to email us at support@alarmgrid.com. Our technicians and security planners will be happy to help you get started with monitoring service for your home or business. We check our email from 9am to 8pm ET M-F. We look forward to hearing from you soon!

Tags: , , , , , , , ,

Comments


Posted By

If you are looking for a wireless sensor solution that comes fully integrated into a door or window, then Andersen Doors and Windows might be for you. There are many Andersen Doors and Windows that come with integrated 345 MHz wireless sensors for using with a compatible alarm system.

Qolsys iq panel 2 plus verizon lte with powerg and legacy honeyw

The wireless sensors that come built into Andersen Doors and Windows are commonly referred to as Andersen Verilock Sensors. For a complete list of Andersen Doors and Windows that utilize these integrated sensors, please see this FAQ as a reference. While we are specifically using this post to highlight the compatibility between the Andersen Verilock Sensors and the 345 MHz Qolsys IQ Panel 2 Plus, there is no reason why you couldn't also use these sensors with a different 345 MHz system, like the Honeywell Lyric or one of the Honeywell LYNX Touch Panels.

The 345 MHz Qolsys IQ Panel 2 Plus serves as a great system for the integrated Andersen Door and Window Sensors, specifically due to the fact that the IQ2+ supports a large number of wireless zones (up to 128). This is important because each Andersen Verilock Sensor will typically use two (2) wireless zones for full system operation. One zone (Loop 1) will monitor for the door or window being opened/closed. The other zone (Loop 2) will monitor for the door or window being locked/unlocked. These sensors have a wireless range of roughly 500 feet when used in an open air environment. Remember that obstacles like thick walls and large metal objects can reduce wireless range.


One very important thing to note about Andersen products is that they are typically only sold through licensed Andersen dealers. Alarm Grid cannot sell these sensors directly. Also, Andersen mandates in its terms of service that their integrated door and window sensors only be installed by professional installers who are certified and approved by Andersen. Failure to comply with the Andersen terms of service can result in the warranty for your door or window being terminated. It is strongly advised that you visit the Andersen website and contact a dealer in your area if you are serious about installing these doors and/or windows.

While Andersen does have strict policies regarding the sale and installation of their integrated sensors, they also have an extensive YouTube Channel with lots of informational and how-to videos involving their products. It is truly a great resource for everyone from the DIY weekend warrior looking to complete their own installation, to the professional installer certified by Andersen. We posted a general informational video from Andersen above, but there are plenty more to check out if you are hoping to learn more about these products.

The best complement for Andersen Security Doors and Windows is alarm monitoring service. And that is a job for Alarm Grid! We offer monitoring plans for all needs and budgets so that you can have an automatic response if your Andersen Door or Window detects activity. If you are hoping to get started with Alarm Grid monitoring service, feel free to email us at support@alarmgrid.com. Our technicians and security planners will be happy to help you get started with monitoring service for your home or business. We check our email from 9am to 8pm ET M-F. We look forward to hearing from you soon!

Tags: , , , , , , , ,

Comments


Posted By

If you're setting up a new security system for use with Alarm.com, then you might be wondering which door and window sensors to use. The answer really comes down to which system you are using and how you intend on using your sensors. Plenty of contact sensor options are usually available!


Alarm sensors do not communicate directly with Alarm.com. Instead, sensors communicate with alarm panels. From there, the panel will use an alarm monitoring communicator to send signals to Alarm.com. This communicator must be activated and registered for Alarm.com service. Per Alarm.com requirements, cellular connectivity is required. This means that your system must use a cellular communicator or a dual-path communicator that is built for use with Alarm.com.

As far as choosing specific sensors, it comes down to determining whether or not they will work with the system you are intending to use with Alarm.com. Today, we're going to break down some of the most popular Alarm.com Security Systems and help you determine the best sensors to use. Remember that our security system kits already come with some compatible sensors to get started. It may only be that you just need to add a few more door and window sensors, or you might not need to add any extra ones at all!

We will give you three (3) scenarios for each system. These are:

  1. Surface-Mounted Door/Window Sensors
  2. Recessed Door/Window Sensors
  3. Outdoor Door/Window Sensors

In most situations, surface-mounted sensors are what you want to go with. These are the standard regular sensors that you would use with virtually any door or window. They are super easy to install, and they are some of the most basic security devices you will encounter.

If appearance is important to you, and you want the sensor to remain hidden while the door or window is closed, then you may consider getting recessed sensors instead. Just remember that recessed sensors will require you rolling up your sleeves and drilling holes into your door/window and its frame. In addition to the added work, this may also have warranty ramifications with regard to the door or window.

And of course, if you plan on using the door/window sensor in an outdoor environment, then you will want to make sure the sensor is approved for outdoor use. Trying to use an indoor-only sensor in an outdoor environment will likely result in damage to the device due to exposure to rain, dust, etc. This also typically applies if you plan on using the sensor in an area that is not insulated, such as a shed, a gate or a barn.

Note: If you are totally new to door and window sensors and want to know more about how they operate, please check out this FAQ.


Qolsys IQ Panel 2 Plus (PowerG)




Arguably the most popular system to use with Alarm.com right now in 2020 is the Qolsys IQ Panel 2 Plus. There are three (3) versions of the system, with each one supporting a different legacy sensor frequency (319.5 MHz, 345 MHz, 433 MHz). We will discuss the legacy sensor options in a minute. But one of the biggest reasons to purchase an IQ Panel 2 Plus is to use PowerG Sensors. All three versions of the Qolsys IQ Panel 2 Plus support the PowerG Sensors. These sensors can communicate with the IQ Panel 2 Plus System from up to 2,000 feet away in open air, and they utilize 128-bit AES encryption and frequency hopping spread spectrum (FHSS) for enhanced wireless security. For anyone with an IQ Panel 2 Plus, these are the sensors we would point to first.


2GIG GC3e & 2GIG GC2e (eSeries)

2gig gc3e wireless encrypted alarm panel

2gig gc2e wireless encrypted alarm panel

Right now, we view the 2GIG GC3e and the 2GIG GC2e as the best alternatives for users who want to get started with Alarm.com, but don't want to use a Qolsys IQ Panel 2 Plus. The most popular sensors to use with these systems are the encrypted 2GIG eSeries Sensors. They are built for the GC3e and GC2e Systems, and they utilize encryption for protection against wireless hacking or takeover attempts. Remember that these systems are both backwards compatible with 345 MHz sensors (more on those later). But if you're running a GC3e or a GC2e, then we're going to recommend the eSeries products.


Original Qolsys IQ Panel 2, IQ Panel, Interlogix Simon Systems (Legacy 319.5 MHz)

Interlogix simon xti 5 80 632 3n xt5 front image
Qolsys iq panel 2 verizon 7 security panel w slash z wave ready
Qolsys iq panel rogers 7 security panel w slash z wave rogers ce

Things become a little tricky when we get into the legacy sensor frequencies. There is usually a lot of inter-compatibility across manufacturers, so often the choice comes down to preference. We will list our favorites based on value and functionality. But understand that you have a lot of options available when it comes to 319.5 MHz sensors. This frequency is used with the original Qolsys IQ Panel 2, the original Qolsys IQ Panel, and all of the legacy Interlogix Simon Series Panels. Keep in mind that you can also use these sensors with the 319.5 MHz version of the IQ Panel 2 Plus as an alternative to PowerG. The 319.5 MHz frequency is also typically used with any wired Interlogix NetworX Panel that has a wireless receiver added.


2GIG GC3 & 2GIG GC2 (Legacy 345 MHz)

2gig gc3 diy wireless security system w slash 7 screen

2gig cp21 345 front

If you are working with a 2GIG GC3 or a 2GIG Go!Control GC2, then you will be enrolling legacy 345 MHz sensors with your system. This frequency was popularized by the Honeywell 5800 Sensors, and later the 2GIG 345 MHz Sensors. The GC2 and GC3 support both of these lineups, so you really have a lot of options to choose from. We're just going to list our particular favorites. Remember that you can also use these sensors with a 345 MHz IQ Panel 2 Plus as an alternative to PowerG.


DSC Impassa & DSC PowerSeries (Legacy 433 MHz)


DSC popularized their own wireless frequency of 433 MHz. If you have a DSC Impassa, then these will be the sensors you are using. The 433 MHz sensors can also be used with a DSC PowerSeries Panel that has a wireless receiver added. Although we do not sell the original DSC PowerSeries Systems, we do offer the DSC RF5132-433 Wireless Receiver that will allow support for these sensors. And of course, you can also use these 433 MHz sensors with the 433 MHz version of the IQ Panel 2 Plus as an alternative to PowerG. Unfortunately, we don't have a good recommendation for a 433 MHz outdoor door and window sensor. so we'll just list the other two types instead.


Honeywell VISTA, DSC PowerSeries, DSC PowerSeries NEO, Interlogix/GE NetworX (Wired Sensors)

Honeywell vista 20p wired alarm control panel

Many hardwired security systems can connect with Alarm.com using what is known as an Alarm.com System Enhancement Module (SEM). And since hardwired panels often use wired sensors, this makes hardwired door and window contacts technically compatible with Alarm.com as well! Honeywell VISTA Systems, DSC PowerSeries Systems, DSC PowerSeries NEO Systems, and Interlogix/GE NetworX Systems all have compatible SEM communicators available.

The great thing about hardwired contacts is that they are pretty much universal across all wired systems, provided that the system is not using polling loop sensors. We'll focus on standard non-polling loop sensors here, but these are all good options for most hardwired alarm panels. Also keep in mind that there are MANY options when it comes to wired contacts. Don't feel like you are restricted to the ones we happened to pick!


Get Started with Alarm Grid & Alarm.com


If you are interested in signing-up for Alarm.com service through Alarm Grid, make sure to check out our monitoring page. We support Alarm.com with our Gold and Platinum Level Plans (Self & Full) and our Cell-Only Plan. If you have any questions about our products or monitoring services, be sure to shoot us an email at support@alarmgrid.com. We operate support hours from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , , , , ,

Comments


Posted By

Hi DIYers! As you know, you can't have a security system without some sensors! Of course, with all the possible sensor types it can be overwhelming to decide which ones you really need for your system. While nearly every sensor type serves a purpose, these are the 5 we deem most crucial.

Alarm grid inside security stickers

5. Glass Break Sensors

Glass break sensors are used to detect broken windows and other glass break events. These devices have built-in microphones, and they actively listen for the sound of breaking glass. Most glass break sensors utilize a dual-sound detection method. This means that the sensor must detect both the low-pitched thud of an object striking against the glass and the high-pitched shattering of the glass itself. This helps prevent false alarms. Glass break sensors are perfect for monitoring for forced entry into your home. You can even use a single glass break sensor to monitor multiple windows in the same room!

2gig gb1 wireless glass break detector

4. Environmental Sensors

Environmental sensors include devices like temperature sensors and flood sensors. These sensors monitor for unusual environmental conditions that likely indicate a problem. For example, a flood sensor will let your system know if there is a water leak that could lead to expensive water damage. Meanwhile, a temperature sensor will monitor for unusually high or low temperatures that indicate a broken HVAC system. There are also many environmental sensors that can perform dual functions and operate as both temperature and flood sensors.

Honeywell 5821 wireless temperature sensor and water sensor exte


3. Life-Safety Sensors

Life-safety sensors are used to monitor for life-threatening environmental conditions, such as a fire or an outbreak of carbon monoxide gas. These include devices like smoke and heat detectors and carbon monoxide sensors. There are also special combination CO and smoke detectors that can monitor for multiple types of life-safety conditions. Enrolling properly functioning life-safety sensors with your system can mean the difference between life and death. And for fires, you will be able to ensure a faster response if one occurs while you are away. These are a must-have for any system.

Honeywell 5800combo smoke heat and co detector

2. Motion Detection Sensors

Motion sensors are some of the most useful sensors you can add to your system. These devices alert the system upon detecting a change in infrared (IR) energy caused by movement. There are also some motion sensors that use microwave radar technology in addition to passive infrared (PIR). You can install motions inside your home as interior sensors to determine if anyone gains entry while you are away. They are perfect for detecting general activity and movement in areas where none should be present. There are even pet-immune motion sensors so that you won't need to worry about your pets setting them off. Just make sure you choose the installation area carefully.

Qolsys qs1231 840 iq motion s encrypted motion sensor

1. Door & Window Contacts

Door and window contacts are the easiest to use and most effective sensors for any alarm system. They are used for letting your system know if someone opens up a door or window. These sensors usually consist of two parts, which are a sensor and a magnet. The sensor goes on the door or window frame, and the magnet goes on the moving part of the door or window. Opening the door or window will cause the magnet to become separated from the sensor. The sensor will detect this and alert the system. There are also recessed door and window sensors that allow for a more aesthetically- pleasing installation!

Honeywell sixct wireless door slash window contact for lyric con

Remember, our goal at Alarm Grid is to set you up with the perfect security system for your needs. We also offer top-quality alarm monitoring services that are great for pairing with a new or existing alarm system. If you ever need help designing or using your security system, or if you want to learn more about our monitoring services, please reach out to us! We are best reached by email at support@alarmgrid.com. Or you may call us at (888) 818-7728 during our regular business hours of 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , ,

Comments


Posted By

Hi DIYers! Today, we're giving a quick lesson on Response Types, also known as Sensor Groups. Every sensor used with your security system will have one. It is important that you get these settings correct so that your alarm system responds appropriately when a sensor is activated!

Honeywell sixct wireless door slash window contact for lyric con


Starting with the basics, the Response Type is the setting that tells the system how to respond when the sensor is activated or faulted. Most Honeywell and 2GIG Systems refer to this as a Response Type. Other systems like the Qolsys IQ Panel 2 Plus refer to this setting as the Sensor Group. For the purpose of this post, we will generally use the terms interchangeably. Just know that when we are talking about Response Types, we also mean Sensor Groups.

When it comes to sensors for alarm systems, there are many types. Some common examples include door and window contacts, motion sensors, glass break sensors, shock sensors, smoke detectors, carbon monoxide sensors, panic buttons, medical alert buttons, temperature sensors, and flood sensors, just to name a few. As a result, there are many Response Types as well. What you use for one sensor type is likely very different from what you would use for another, though there is some overlap from time to time.

Now, we're not going to cover each and every Response Type and Sensor Group here today. But what we will do is cover some general rules for Response Types so that you know a little bit more about them. If you do want some more extensive knowledge on Response Types or Sensor Groups, check the programming manual for your panel. We also have the following FAQs that you may want to check out:

With that out of the way, let's take a look at some of the most basic and general Response Types you will encounter.

Entry/Exit: An Entry/Exit Zone is used for coming and going. This is almost always going to be a door that you use to enter and/or exit your home or business. When this zone is faulted while the system is Armed Away or Armed Stay, you will need to Disarm your system within a preset Entry Delay period, or else an alarm will occur. Additionally, if your system has Auto-Stay Arming enabled, then you will need to fault an Entry/Exit Zone during the Exit Delay countdown when Arming Away, or else the system will revert to Armed Stay instead.

  • Common Sensor Types: Door and Window Sensors for Entering/Exiting the Building

Interior: An Interior Zone refers to a sensor that can trigger an alarm while the system is Armed Away, but not while the system is Armed Stay. The idea here is that when your system is Armed Away, there should be nobody inside the building, and faulting an Interior Zone would mean there is a security breach. But when the system is Armed Stay, there is still someone inside the building, and you want them to be able to move around freely. A very common sub-type of an Interior Zone is an Interior Follower Zone. The "follower" portion of the name refers to the fact that the zone will not cause an alarm if the sensor is after (e.g. it follows) an Entry/Exit Zone. The reasoning is that you may need to fault an Interior Zone to get to your system and Disarm after faulting an Entry/Exit Zone.

  • Common Sensor Types: Interior Motion Sensors, Interior Door and Window Sensors

Perimeter: A Perimeter Zone is a very secure sensor. If a Perimeter Zone is faulted while the system is Armed Away or Armed Stay, then an alarm will occur immediately. You should only assign a Perimeter Zone to a sensor that should absolutely never be faulted while the system is Armed. Perimeter Zones are commonly used for Window Sensors (unless you like to climb in through the window!), as well as Glass Break Sensors and Shock Sensors that indicate forced entry into the building. Some panels also have a similar Response Type called Day/Night. This Response Type is the same as Perimeter, except that a Day/Night Zone will also trigger a Trouble condition if the sensor is faulted while the system is Disarmed.

  • Common Sensor Types: Window Sensors, Glass Break Sensors, Shock Sensors

24-Hour: A 24-Hour Zone is the most secure Zone Type available. This is a sensor that should never be activated, unless there is an emergency or something seriously wrong. There are many sub-categories of 24-Hour Zones, including 24-Hour Burglary, 24-Hour Fire, 24-Hour Carbon Monoxide, and 24-Hour Auxiliary. Since these are very secure zones, you will likely want to provide special instructions regarding these zones for the central monitoring station. This way, the operator will know how to respond when they see the alarm come through. For example, if you give your Flood Sensor a 24-Hour Auxiliary Response Type, you will want the operator to know that it isn't an emergency medical alarm! The 24-Hour Auxiliary Response Type is often used for both environmental sensors and medical sensors, so you will want to provide specification.

  • Common Sensor Types: Smoke & Heat Detectors, Carbon Monoxide Sensors, Panic Buttons, Medical Alert Buttons, Flood Sensors, Temperature Sensors

Of course, this is just a small list of the available Response Types and Sensor Groups. But you will usually find Zone Types just like these no matter which panel you use. If you want to learn more about Response Types, you are welcome to send us an email at support@alarmgrid.com. We will check your email when we have an opportunity and reply back as soon as possible. Remember that our support hours are from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , ,

Comments


Posted By

Hi DIYers! We're here with another Alarm Grid Tip. We're going to cover the proper technique for mounting your door alarm sensors. Many people have trouble getting a faulted zone to disappear when their sensors are not aligned properly. Mounting your sensors correctly will fix this issue.

Honeywell 5800mini interior wireless door and window sensor

First, It's important to understand how door and window contacts work. There are two (2) parts. These are a sensor and a magnet. The sensor is the larger component and usually represents the listed product dimensions. The magnet is the smaller component. In a proper installation, the sensor (larger) should be mounted on the door frame. The magnet (smaller) should be mounted on the actual door. Ideally, the magnet and the sensor should be in direct contact when the door is closed. The magnet should also be aligned with the metal reed switch inside the sensor. The sensor will most likely have indentations to indicate the location of the reed switch.

The idea is that when the door is closed, the magnet will be in contact with the sensor. This is why these sensors are often called "contacts". When the door is opened, the magnet will become separated from the sensor. This will release its internal metal reed switch. When this happens, the sensor will transmit a signal to the alarm control panel. The system will respond based on the programming settings for the corresponding zone.

When you mount your door contacts, you should make sure that the magnet and the sensor are in proper alignment when the door is closed. If not, then the reed switch inside the sensor will stay open. As a result, the zone will still be shown as faulted on the panel. You want proper alignment so that the zone functions consistently. Whenever the door is opened, the zone should appear as faulted. If it's closed, then you should not see any faults.

Walk testing your contacts is extremely important! This is the best way to make sure that the sensor and magnet are in proper alignment. Sure, it might pass the eyeball test, but does it pass the system test? Always, always, always test your equipment! We don't care if you are a novice DIYer or a seasoned professional installer - your job is not finished until you have completed the walk test.

Again, the ideal door sensor and magnet will be IN DIRECT CONTACT when the door is closed. This will provide the best possible results. We have seen customers stack multiple pieces of double-sided foam tape to make this happen. This is pretty unusual, but it works! It might look funny if you have to do that, but it will get the job done! As long as the sensor and magnet are in correct alignment, then the sensor will work.

If you absolutely must leave the contact and magnet separated, do not do so from more than one-half (0.5) of an inch, unless the manual specifically says that the sensor-magnet gap can be further. And make sure to test extra thoroughly if you decide to try and get these sensors to work with a wider magnet spacing.

Also remember to check sensor for indentations that indicate which side to place the magnet. If you are unsure, then check the device manual. Many answers can be found in the installation instructions. Unfortunately, many end users choose to ignore them. Read the manual!

Keep in mind that some door sensors may be equipped with LED lights that help the installer make sure that the sensor and magnet are indeed in proper alignment. If your sensor has this feature, then definitely use it! This is an easy and convenient way to make sure they are aligned correctly. Check your device manual for more information. An example of a door sensor that is equipped with this feature is the Honeywell 5800MINI.

Below is an example of what a properly installed contact looks like. In this case, it is the 2GIG DW10. Note how the sensor and the magnet are in direct contact and properly aligned. Normally, the battery tab at the bottom of the sensor would be removed, but for this example, it's okay.


We hope this tip has been helpful for anyone setting up their first alarm system. Please email us at support@alarmgrid.com if you have any questions. We look forward to hearing from you!

Tags: , , , , , , , , , , ,

Comments


Posted By

A couple of weeks ago, we released a complete guide to door contact sensors. Today, we're taking a look at alarm window contacts. Admittedly, there's not much difference between door sensors and window sensors. Many can be used interchangeably. But there are a few tips to keep in mind.

Qolsys iq dw mini s encrypted wireless sensors for iq panel 2 qsFirst, let's review how alarm contacts actually work. It is the same general process for both doors and windows. These devices consist of two portions, those being a sensor and a magnet. When the sensor and magnet are in direct contact or very close proximity, a reed switch inside the sensor will remain closed. Once the magnet becomes separated from the sensor, the reed switch will be released, and the sensor will know to alert the system to let it know that the structure has been opened.

The key with window contacts is to place them so that when the window is opened, the magnet and the sensor will become separated. But when the structure is closed, the sensor are magnet will remain in direct or near-direct contact. It is almost always recommended to place the sensor on the stationary frame of the window and the magnet on the moving portion of the window that is opened and closed. This will prevent the more valuable sensor from being pushed around and potentially damaged. The magnet is designed to take much more abuse and use than the sensor itself. Positioning the sensor this way will also make it easier to wire the sensor if a hardwired contact is being used.

Honeywell 951wg wh 3 slash 8 diameter miniature recessed contactOne special note with window contacts is that they are only designed to let a system know when a window has been opened normally. If an intruder smashes a window to gain entry, they will avoid activating a window contact, as long as the sensor remains in contact with its magnet. This means that they might be able to gain entry without setting off an alarm. Fortunately, there are two other types of sensors that can be used to alert an alarm system to a broken window. These are glass break sensors and shock sensors. Glass break sensors detect the audible sound of a window being broken, while shock sensors detect the physical vibrations associated with a broken window. However, these sensors are used for intrusion support only. Unlike a standard window contact, they will not let the user know if the window has merely been left open by accident. But they are still recommended for users who want to know if a window has been broken. We generally prefer glass break sensors over shock sensors, since they tend to work more reliably. It can also be helpful to use monition detection sensors alongside standard window contacts to detect any movement in the building.

Honeywell sixgb wireless glass break detector

Just like door sensors, window sensors can be either surface-mounted or recessed. Another major distinction is whether they are wireless or hardwired. So really, window sensors can be grouped into four major types. These are wireless surface-mounted, wireless recessed, hardwired surface-mounted and hardwired recessed. Choosing the perfect variation for your window and the type of installation you want to perform is crucial for success. Fortunately, it's relatively easy to decide on the perfect type of window sensor for your needs.

Simply put, surface-mounted sensors are installed on the exterior surface of the window and its frame. This means that they will be visible when looking at window. However, these sensors are usually very small and discreet, so they won't normally be drawing direct attention to themselves. A major advantage to surface-mounted sensors is that they are very easy to install, since no holes necessarily need to be drilled. Instead, many surface-mounted sensors and magnets can be mounted using double-sided foam tape.

The other option is to use recessed sensors. These sensors are hidden inside the window and its frame so that they are out of view. To do this, holes must be drilled into both the window and its frame for the magnet and sensor. Using recessed sensors for windows is somewhat less common than it is for doors. This is because some windows don't have an effective solution for drilling a hole to insert a magnet. Additionally, some window manufacturers put disclaimers stating that drilling holes into the window will void its warranty. But if the window has space for a hole to be drilled so that the magnet can be accommodated, then a recessed window sensor can certainly work. Please note that recessed plunger switches aren't normally used with windows, but there's no definitive reason why they couldn't work in certain situations.

A special mention needs to go to the Honeywell 5800Micra. This is a recessed alarm contact specifically designed for use with windows. The advantage to the 5800Micra is that only one hole needs to be made in the window frame for the sensor. The magnet is small enough that it can be surface-mounted on the side or bottom of the window. It uses an adhesive backing to remain securely in place. This is a great way to achieve a recessed installation without having to void the manufacturer's warranty for your window. Please note that the Honeywell 5800Micra is a wireless sensor that operates at 345 MHz. It is part of the Honeywell 5800 Series, and it will only work with compatible systems.

Honeywell 5800micra wireless recessed window contactUsers must also decide between wireless and hardwired sensors for their windows. Wireless sensors are much easier to install, since no wires need to be run. They are the recommended option for almost any DIY installer. Assuming that you have a wireless system with a wireless receiver, there is almost certainly a contact that will work for you. Just make sure that the sensor operates at a frequency that is compatible with your panel. The most common wireless frequencies at 319.5 MHz, 345 MHz, 433 MHz and 915 MHz. Additionally, the encrypted Honeywell SiX Series Contacts, the Honeywell SiXCT and Honeywell SiXMINICT operate at 2.4 GHz WIFI.

If you go with hardwired contacts, the installation will be more challenging, since wires must be run. This can sometimes be an impossible task for the typical DIY user. However, there are two distinct advantages that make hardwired window sensors suitable for certain applications. For one, having them integrate with the building can add to the property value. Users also appreciate the fact that they never need to replace batteries for hardwired sensors.

Below is a table that outlines many of the window contacts available for purchase on the Alarm Grid site. It's actually the same as the one posted for our door contacts guide, only with some minor tweaks for windows. Make special note of the Honeywell 5800Micra at the very bottom!

Sensor Name
Communication Frequency
Surface-Mounted or Recessed
Special Notes
VERSA-GE 319.5 MHz Surface-Mounted Same as 5800MINI, but for 319.5 MHz Systems.
VERSA-2GIG 345 MHz Surface-Mounted Same as 5800MINI, but will only work with 2GIG Systems, the Honeywell Lyric Controller, and the IQ Panel 2 Plus with 345 MHz Daughercard.
Honeywell 5800MINI
345 MHz Surface-Mounted Very popular slim sensor that is used with Honeywell Systems.
Honeywell SiXMINICT 2.4 GHz Surface-Mounted Encrypted 2.4 GHz Sensor designed for use with Lyric System only. It is smaller and more discreet than the similar SiXCT, but offers less range. Uses 128-bit AES encryption.
Honeywell SiXCT 2.4 GHz Surface-Mounted Encrypted 2.4 GHz Sensor designed for use with Lyric System only. Larger than the SiXMINICT, but offers superior range. Uses 128-bit AES encryption.
Qolsys IQ DW MINI-S 319.5 MHz Surface-Mounted Encrypted S-Line Sensor. Will only utilize encryption when used with an IQ Panel 2 or IQ Panel 2 Plus System. Otherwise operates as standard unencrypted sensor. Mini version of IQ Door Window-S.
Honeywell 5818MNL 345 MHz Recessed Recessed sensor from Honeywell 5800 Series. Requires 0.75" diameter hole that is 3" deep to be drilled in the window frame. Hole must also be drilled into the window for the magnet.
Honeywell 5820L 345 MHz Surface-Mounted Slim Line sensor that is great for applications that require a thinner sensor.
2GIG DW10 345 MHz Surface-Mounted Door contact designed by 2GIG. Will only work with 2GIG Systems, the Honeywell Lyric Controller, and the IQ Panel 2 Plus with 345 MHz Daughtercard.
Honeywell 5816 345 MHz Surface-Mounted Honeywell's most popular wireless sensor! Also includes a wireless transmitter for a normally closed hardwired device.
DSC PG9945 915 MHz Surface-Mounted PowerG Sensor with up to 2km range. Also features an auxiliary input and wireless transmitter for a normally closed hardwired device. Uses 128-bit AES encryption.
Qolsys IQ Door Window-S 319.5 MHz Surface-Mounted Encrypted S-Line Sensor. Will only utilize encryption when used with an IQ Panel 2 or IQ Panel 2 Plus System. Otherwise operates as standard unencrypted sensor. Larger version of IQ DW MINI-S.
Interlogix TX-E221 319.5 MHz Recessed Relatively standard recessed sensor that works with 319.5 MHz systems.
2GIG DW20R 345 MHz Recessed Recessed contact from 2GIG. Will only work with 2GIG Systems, the Honeywell Lyric Controller, and the IQ Panel 2 Plus with 345 MHz Daughtercard.
DSC PG9975 915 MHz Surface-Mounted PowerG vanishing surface-mounted contact with thin profile. Great for any standard application where PowerG Sensors are supported.
Qolsys IQ Recessed Door-S 319.5 MHz Recessed Encrypted recessed sensor from Qolsys. Will only utilize encryption when used with an IQ Panel 2 or IQ Panel 2 Plus System. Otherwise operates as standard unencrypted sensor.
Qolsys IQ Mini 319.5 MHz Surface-Mounted Standard door and window contact from Qolsys. Same as IQ DW MINI-S, but without encryption features.
DSC WS4945 433 MHz Surface-Mounted Surface-mounted door contact for 433 MHz DSC Systems.
DSC EV-DW4975 433 MHz Surface-Mounted Slim line version of DSC WS4945.
DSC EV-DW4917 433 MHz Recessed Recessed contact for 433 MHz DSC Systems.
Qolsys IQ DW Standard 319.5 MHz Surface-Mounted Unencrypted version of Qolsys IQ Door Window-S.
Honeywell 951WG Hardwired Recessed Recessed hardwired contact with leads. Measures 3/8" in diameter.
Honeywell PAL-T Hardwired Surface-Mounted Currently the smallest hardwired surface-mounted contact offered from Alarm Grid.
Honeywell 7939WG Hardwired Surface-Mounted Relatively standard hardwired surface-mounted contact manufactured by Honeywell.
Honeywell 944T Hardwired Recessed Recessed hardwired contact with screw terminals. Measures 3/8" in diameter.
Honeywell 944TSP Hardwired Recessed Recessed hardwired contact with screw terminals. Measures 3/4" in diameter.
Honeywell 7939-2 Hardwired Surface-Mounted Basically same as Honeywell 7939WG, but is Form C for normally closed or normally open wiring.
Honeywell 940 Hardwired Surface-Mounted Relatively standard hardwired surface-mounted contact manufactured by Honeywell.
Honeywell MPS5 Hardwired Recessed Recessed contact with leads and diameter of 1/4".
Honeywell 944SP Hardwired Recessed Recessed contact with leads and diameter of 3/4".

Honeywell 5800Micra 345 MHz Recessed One of our favorite recessed contacts, designed exclusively for windows! Magnet is surface-mounted and does not require a drilled hole. This can allow for a recessed installation without voiding the warranty for the window.

If you need any help deciding on the perfect window sensor, do not hesitate to reach out to us! You may email us at support@alarmgrid.com or call us at (888) 818-7728 during our normal business hours, which are 9am to 8pm EST M-F. We also encourage you to check out our monitoring page for more information about the services we offer. We look forward to hearing from you!

Tags: , , , , , , , , , , , ,

Comments


Posted By

Door contacts represent some of the most popular sensors that are used with alarm systems. Nearly every setup will incorporate these devices in some form. After all, knowing when a door has been opened is critical for most systems. But there is a lot to consider when choosing door contacts.

Honeywell 5816 wireless door window sensor

A door sensor is a device that is used to let an alarm control panel know when a door has been opened. When this happens, the system will respond depending on panel's current arming state and the programming settings for the zone. Some popular responses for door contacts include requiring a system disarm within the entry delay period, producing a simple chime and triggering an immediate alarm. These responses are present with virtually any door contact and system setup. A previous blog post of ours actually covers the Response Types for door sensors in greater detail. We recommend checking out that post for more information. But while the general functionality is the same across almost any contact, selecting the best option for your system might seem overwhelming.

Perhaps the first thing you should consider is whether you want a hardwired contact or a wireless contact. A wired contact will communicate with the panel through a direct hardwired connection. A wireless contact will communicate with the panel through wireless RF signals. The advantage to a wireless sensor is that it will be much easier to set up, since no wires will need to be run from the system to the sensor. But some users prefer hardwired sensors, as they essentially become a fixture for the building itself. Another advantage to hardwired contacts is that they don't use batteries. This means that a user will never have to buy new batteries for their hardwired contact. There are all types of door sensors in both the hardwired and wireless variety.

If you choose a hardwired contact, you will need to have a hardwired zone available on your system. Most hardwired contacts can be used with nearly any system that supports hardwired sensors. On the other hand, if you choose a wireless contact, you will need to have a wireless zone available. You will also need to make sure the wireless contact communicates at an RF frequency that is compatible with your system. Knowing which wireless RF signals are accepted by your alarm system is very important for getting sensors to work properly. Some of the most popular RF signals used by alarm systems include 319.5 MHz, 345 MHz, 433 MHz, 915 MHz and 2.4 GHz. Remember to always make sure the wireless door contact you choose operates at a frequency that works with your alarm system!

Qolsys iq dw mini s encrypted wireless sensors for iq panel 2 qs

Honeywell pal t wh surface mount door contact and window contact

Another major distinction for door contacts is whether they are surface-mounted or recessed. A surface-mounted contact is visible on the outside of the door. A recessed contact is hidden inside the door and its frame. As a general rule, surface-mounted contacts are easier to install, since no holes need to be drilled. But the advantage to recessed contacts is that the end result can appear neater, since no sensor will be visible. We generally recommend that users installed surface-mounted sensors, due to the fact that they are easier to install and generally offer more reliable performance.

With that in mind, door sensors can be assigned to one of four major categories. These are wireless surface-mounted contacts, wireless recessed contacts, hardwired surface-mounted contacts and hardwired recessed contacts. Regardless of which category a door contact is assigned, these devices generally all work in the same way. Most door contacts consist of a sensor and a magnet. The sensor is installed on the stationary portion of the door frame, while the magnet installed on the moving portion of the door. In most cases, the magnet must be within a half-inch of the sensor. Placing the sensor itself on the stationary portion of the door helps prevent it from being damaged when the door is opened or closed. Once the door is opened, the magnet will separate from the sensor and cause a reed switch inside the sensor to activate. The sensor will then alert the system to let it know that the door has been opened. Please note that there are a few door sensors that are exceptions to this general operation. Namely, recessed sensors that use a plunger switch, like the wireless Honeywell 5800RPS and the hardwired Honeywell 956RPT.

Honeywell 5818mnl wireless recessed door sensor and window sensoBefore we get into general door contacts that would be used for most applications, we want to make special mention of some more unique sensors that would be used for specific setups. Honeywell offers many hardwired wide-gap contacts that can be used with garage doors and industrial applications. The advantage to these sensors is that they can utilize a much larger spacing gap between the sensor and magnet than what is possible with standard door contacts. We have seen some industrial contacts where the spacing gap can be up to 2.5 inches. That's five times the recommended maximum spacing gap for standard door contacts! Some examples of these industrial-grade hardwired contacts include the Honeywell 958, the Honeywell 968XTP, the Honeywell 959, the Honeywell 958-2, the Honeywell 950W, the Honeywell 960 and the Honeywell 7945. Many of these industrial-grade contacts are also suitable for outdoor use. Another option for a garage door is to use a tilt sensor, like the Honeywell 5822T or an Interlogix TX-E401.

But if a user requires a wireless contact for an outdoor application, there only option is really the Honeywell 5816OD. This wireless contact offers a recommended maximum spacing gap of 1.5" inches, and it is great for use with fences and outside doors. It has a nominal range of 200 feet when used with most systems. As a 345 MHz Sensor from the Honeywell 5800 Series, it will work with nearly any Honeywell Alarm System.

Honeywell 5816od wireless outdoor door and window sensor topIf you don't require an industrial or an outdoor contact, you will most likely be able use a relatively standard contact with your alarm system. We prepared a table below that outlines many of the most popular and widely used door contacts sold by Alarm Grid. Please note that not every contact is included - there would be too many to list! But this is a good chart to help you find the perfect sensor for your system.

Sensor Name
Communication Frequency
Surface-Mounted or Recessed
Special Notes
VERSA-GE 319.5 MHz Surface-Mounted Same as 5800MINI, but for 319.5 MHz Systems.
VERSA-2GIG 345 MHz Surface-Mounted Same as 5800MINI, but will only work with 2GIG Systems, the Honeywell Lyric Controller, and the IQ Panel 2 Plus with 345 MHz Daughercard.
Honeywell 5800MINI
345 MHz Surface-Mounted Very popular slim sensor that is used with Honeywell Systems.
Honeywell SiXMINICT 2.4 GHz Surface-Mounted Encrypted 2.4 GHz Sensor designed for use with Lyric System only. It is smaller and more discreet than the similar SiXCT, but offers less range. Uses 128-bit AES encryption.
Honeywell SiXCT 2.4 GHz Surface-Mounted Encrypted 2.4 GHz Sensor designed for use with Lyric System only. Larger than the SiXMINICT, but offers superior range. Uses 128-bit AES encryption.
Qolsys IQ DW MINI-S 319.5 MHz Surface-Mounted Encrypted S-Line Sensor. Will only utilize encryption when used with an IQ Panel 2 or IQ Panel 2 Plus System. Otherwise operates as standard unencrypted sensor. Mini version of IQ Door Window-S.
Honeywell 5818MNL 345 MHz Recessed Recessed sensor from Honeywell 5800 Series. Requires 0.75" diameter hole that is 3" deep to be drilled in the door frame.
Honeywell 5820L 345 MHz Surface-Mounted Slim Line sensor that is great for applications that require a thinner sensor.
2GIG DW10 345 MHz Surface-Mounted Door contact designed by 2GIG. Will only work with 2GIG Systems, the Honeywell Lyric Controller, and the IQ Panel 2 Plus with 345 MHz Daughtercard.
Honeywell 5816 345 MHz Surface-Mounted Honeywell's most popular wireless sensor! Also includes a wireless transmitter for a normally closed hardwired device.
DSC PG9945 915 MHz Surface-Mounted PowerG Sensor with up to 2km range. Also features an auxiliary input and wireless transmitter for a normally closed hardwired device. Uses 128-bit AES encryption.
Qolsys IQ Door Window-S 319.5 MHz Surface-Mounted Encrypted S-Line Sensor. Will only utilize encryption when used with an IQ Panel 2 or IQ Panel 2 Plus System. Otherwise operates as standard unencrypted sensor. Larger version of IQ DW MINI-S.
Interlogix TX-E221 319.5 MHz Recessed Relatively standard recessed sensor that works with 319.5 MHz systems.
2GIG DW20R 345 MHz Recessed Recessed contact from 2GIG. Will only work with 2GIG Systems, the Honeywell Lyric Controller, and the IQ Panel 2 Plus with 345 MHz Daughtercard.
DSC PG9975 915 MHz Surface-Mounted PowerG vanishing surface-mounted contact with thin profile. Great for any standard application where PowerG Sensors are supported.
Qolsys IQ Recessed Door-S 319.5 MHz Recessed Encrypted recessed sensor from Qolsys. Will only utilize encryption when used with an IQ Panel 2 or IQ Panel 2 Plus System. Otherwise operates as standard unencrypted sensor.
Qolsys IQ Mini 319.5 MHz Surface-Mounted Standard door and window contact from Qolsys. Same as IQ DW MINI-S, but without encryption features.
DSC WS4945 433 MHz Surface-Mounted Surface-mounted door contact for 433 MHz DSC Systems.
DSC EV-DW4975 433 MHz Surface-Mounted Slim line version of DSC WS4945.
DSC EV-DW4917 433 MHz Recessed Recessed door contact for 433 MHz DSC Systems.
Qolsys IQ DW Standard 319.5 MHz Surface-Mounted Unencrypted version of Qolsys IQ Door Window-S.
Honeywell 951WG Hardwired Recessed Recessed hardwired contact with leads. Measures 3/8" in diameter.
Honeywell PAL-T Hardwired Surface-Mounted Currently the smallest hardwired surface-mounted contact offered from Alarm Grid.
Honeywell 7939WG Hardwired Surface-Mounted Relatively standard hardwired surface-mounted contact manufactured by Honeywell.
Honeywell 944T Hardwired Recessed Recessed hardwired contact with screw terminals. Measures 3/8" in diameter.
Honeywell 944TSP Hardwired Recessed Recessed hardwired contact with screw terminals. Measures 3/4" in diameter.
Honeywell 7939-2 Hardwired Surface-Mounted Basically same as Honeywell 7939WG, but is Form C for normally closed or normally open wiring.
Honeywell 940 Hardwired Surface-Mounted Relatively standard hardwired surface-mounted contact manufactured by Honeywell.
Honeywell MPS5 Hardwired Recessed Recessed contact with leads and diameter of 1/4".
Honeywell 944SP Hardwired Recessed Recessed contact with leads and diameter of 3/4".

If you're still having trouble deciding on the perfect door contact for your alarm system, our experts are always happy to help. You may email us at support@alarmgrid.com, and we will get back to you as soon as possible. You may also call us at (888) 818-7728 during normal business hours, which are 9am to 8pm EST M-F. We look forward to hearing from you!