Honeywell 5819S Posts

Posted By

A great way to build out your Honeywell Lyric is with Honeywell 5800 Sensors. These are simple, 345 MHz wireless sensors that you can easily enroll with the system for security, life-safety, and environmental monitoring. They are perfect for expanding your system and making it more robust.

Honeywell lyric controller encrypted wireless security system

When you want to pair a Honeywell 5800 Sensor with the Lyric, the process is very straightforward. Put the Lyric in its auto-enrollment mode by choosing Security > Tools > enter Installer Code (default 4112) > Program > Zones > Add New > Serial Number. Make sure the RF Type on the right-hand side is set to 5800. Then activate the sensor either by faulting it or triggering its cover tamper switch. The Lyric should beep to confirm that it received a signal transmission. Then activate the sensor a second time to have the Lyric display the Serial Number. The third activation will confirm the Serial Number and return you to the screen where you can configure the zone settings.


Programming the zone settings for the sensor is actually quite simple. Depending on how you enrolled the sensor, you may need to adjust the Loop Number. This is almost always the case if you enrolled the sensor by activating its tamper switch. Refer to the instruction manual for the 5800 Sensor to determine which Loop Number to use.

The two (2) Zone Descriptors and the Device Type serve as the name for the sensor. You should choose a name that will help you identify the sensor, e.g. "Front Bedroom Motion Sensor", "South Hallway Door", etc. The Response Type determines how the system responds when the sensor is faulted. See our list of Lyric Response Types for more info.

Alarm Report should be set to Yes if you want the system to report out through AlarmNet to a Central Station if the zone causes an alarm on the system. That is an essential component of alarm monitoring services. Chime is optional, and it has the panel emit any one of several available sounds when the zone is faulted. Supervision tells the panel to look for an RF check-in signal from the sensor periodically to ensure that it is online. Click Save in the bottom-right after you finish adjusting the settings.


Keep in mind that only uni-directional (one-way) sensors from the Honeywell 5800 Series can be used with the Lyric. This leaves out bi-directional devices like the Honeywell 5800WAVE Siren, the Honeywell 5828 Keypad, and the Honeywell 5800RL Relay Module, so make sure you do not buy those for the Lyric. But you still have a lot of excellent sensors and security devices to choose from.

Below is a list of the Honeywell 5800 Sensors that you can use with the Honeywell Lyric:

Sensor Name
Notes
Honeywell 5800MINI
Honeywell 5800mini interior wireless door and window sensor
Door/Window sensor. Uses Loop 1.
Honeywell 5800PIR-RES
Honeywell 5800pir res wireless pet immune motion detector close up
PIR motion sensor. Uses Loop 1.
Coverage Area: 35' x 40'
Honeywell 5816
Honeywell 5816 wireless door window sensor
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5811
Honeywell 5811 wireless wafer thin door and window sensor
Door and window sensor. Uses Loop 1.
Honeywell 5800C2W
Honeywell 5800c2w hardwire to wireless system 9 zone conversion module
9-zone wired to wireless converter. Allows hardwired sensors to communicate with the Lyric as wireless devices. All zones use Loop 1 and a unique Serial Number ID.
Honeywell 5800CO
Honeywell 5800co wireless carbon monoxide detector
Carbon monoxide sensor.
Loop 1 = CO Detection
Loop 2 = End of Sensor Life (separate programming only required on TURBO and other V-Plex panels)
Honeywell 5800COMBO
Honeywell 5800combo smoke heat and co detector
Combination, smoke, heat, CO, and low-temperature sensor. Uses up to five (5) zones on the Lyric Panel. Has two (2) Serial Numbers for enrollment purposes.
Loop 1, SN 1 = Smoke/Heat Detection
Loop 2, SN 1 = Smoke/Heat Maintenance
Loop 3, SN 1 = Low Temperature Detection
Loop 1, SN 2 = CO Detection
Loop 2, SN 2 = End of Sensor Life (separate programming required only on TURBO and other V-Plex panels)
Honeywell 5800FLOOD
Honeywell 5800flood wireless flood and temperature sensor
Flood and temperature sensor.
Loop 1 = Low Temperature Detection
Loop 2 = High Temperature Detection
Loop 3 = Flood Detection
Honeywell 5800MICRA
Honeywell 5800micra wireless recessed window contact
Recessed window sensor. Uses Loop 1.
Honeywell 5800PIR
Honeywell 5800pir exterior of wireless motion detector
PIR motion sensor.
Loop 1 = Low Sensitivity Motion.
Loop 2 = High Sensitivity Motion.
Loop 3 = Low Temperature Detection
Coverage Area: 35' x 40'
Honeywell 5800PIR-COM
Honeywell 5800pir com exterior of wireless long range motion det
Commercial PIR motion sensor.
Loop 1 = Low Sensitivity Motion
Loop 2 = High Sensitivity Motion
Loop 3 = Low Temperature Detection
Coverage Area: 60' x 80'
Honeywell 5800PIR-OD
Honeywell 5800pir od wireless outdoor motion detector exterior
Outdoor PIR motion sensor. Uses Loop 1.
Honeywell 5800PIR-OD2
Outdoor PIR motion sensor. Uses Loop 1.
Honeywell 5800RP
Honeywell 5800rp wireless repeater
Wireless repeater for Honeywell 5800 Sensors. Does not require enrollment, but can be assigned a single zone for RF supervision, low-battery, AC loss, and RF jam detection. This is done using Serial Number 1 with Loop 1, with DIP Switch 2 set in the OFF position. Can also use up to four (4) separate zones for supervision when DIP Switch 2 is set to ON. This is required for UL installations.
Honeywell 5800RPS
Honeywell 5800rps wireless recessed door and window plunger sens
Recessed door/window sensor. Uses Loop 1.
Honeywell 5800SS1
Honeywell 5800ss1 exterior of wireless shock sensor
Shock sensor. Uses Loop 1.
Honeywell 5802MN
Honeywell 5802 wireless panic button
Medical alert button. Uses Loop 1.
Honeywell 5802MN2
Honeywell 5802mn2 wireless dual button medical alert
Medical alert button. Uses Loop 1.
Honeywell 5802WXT
Honeywell 5802wxt wireless panic button
Panic button. Uses Loop 1.
Honeywell 5802WXT-2
Honeywell 5802wxt 2 wireless dual button medical alert
Panic button. Uses Loop 1.
Honeywell 5806W3
Honeywell 5806w3 wireless smoke detector
Smoke detector. Uses Loop 1.
Honeywell 5808W3
Honeywell 5808w3 wireless smoke and heat detector
Smoke and heat detector.
Loop 1 = Smoke & Heat Detection
Loop 3 = Low Temperature Detection
Honeywell 5809
Honeywell 5809 wireless heat detector
Fixed temperature and rate-of-rise heat detector. Uses Loop 1. Alarm occurs when the temperature exceeds 135 degrees Fahrenheit, or when the temperature rises more than 15 degrees Fahrenheit per minute.
Honeywell 5809FXT
Honeywell 5809 wireless heat detector
Fixed temperature heat detector. Uses Loop 1. Alarm occurs when the temperature exceeds 135 degrees Fahrenheit.
Honeywell 5809SS
Honeywell 5809ss wireless fixed temperature slash ror heat detec
Fixed temperature and rate-of-rise heat detector. Uses Loop 1. Alarm occurs at 135 degrees Fahrenheit or when the temperature rises more than 15 degrees Fahrenheit per minute.
Honeywell 5814
Honeywell 5814 wireless small door sensor and window sensor
Door and window sensor. Uses Loop 1.
Honeywell 5815
Honeywell 5815 white wireless aesthetic door sensor and window s
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5816MN
Honeywell 5816mn wireless mini door sensor and window sensor
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switches
Honeywell 5816OD
Honeywell 5816od wireless outdoor door and window sensor top
Outdoor door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5817
Honeywell 5817 wireless three zone sensor
Three (3) zone door and window sensor & transmitter.
Loop 1 = NC or NO (DIP Switch Selectable) unsupervised. It does not use an End of Line Resistor (EOLR)
Loop 2, 3 = NC Only. Both are unsupervised with no EOLR used
Honeywell 5817CBXT
Honeywell 5817cb wireless commercial sensor
Three (3) zone commercial transmitter.
Loop 1 = Two (2) Terminals; Primary Loop supervised by 470k Ohm (yellow, purple, yellow, gold) EOLR. Resistor must ALWAYS be installed, even if Loop 1 is not programmed. If Loop 1 is used as a burglary zone, then Loop 4 must be programmed as a separate zone for Cover Tamper protection.
Loop 2 = NC Reed Switch
Loop 3 = Two (2) Terminals; NC Loop unsupervised, no EOLR required
Honeywell 5817XT
Honeywell 5817xt three zone universal transmitter
Three (3) zone door and window sensor & transmitter.
Loop 1 = NC or NO (DIP Switch Selectable) unsupervised with no EOLR required
Loop 2, 3 = Two (2) Terminal Blocks, NC Only
Honeywell 5818MNL
Honeywell 5818mnl wireless recessed door sensor and window senso
Recessed door and window sensor. Uses Loop 1. Not suitable for use in metal doors
Honeywell 5819
Honeywell 5819 wireless shock processor and sensor
Three (3) zone shock processor.
Loop 1 = NC for Inertia Style External Shock Sensor. This input provides a suitable fast loop response of from 1ms to 20ms, based on dip switch setting
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact, unsupervised with no EOLR required
Honeywell 5819S
Honeywell 5819s wireless shock sensor and transmitter
Shock sensor and contact sensor.
Loop 1 = Built-in Inertia Style Shock Sensor
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact
Honeywell 5819WHS
Honeywell 5819whs wireless transmitter with integrated shock sen
Three (3) zone shock processor.
Loop 1 = NC, Built-in Inertia Style Shock Sensor
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact
Honeywell 5820L
Honeywell 5820l super slim wireless door and window sensor
Slimline door and window sensor. Uses Loop 1.
Honeywell 5822T
Honeywell 5822t wireless garage tilt sensor
Garage tilt sensor.
Loop 1 = NC for Wired Contact, unsupervised, no EOLR used
Loop 3 = Tilt Switch
Honeywell 5834-2
Honeywell 5834 2 wireless 2 button security key fob
Two (2) button key fob. Dual-button inputs allowed. Uses three (3) loops total, for a possible three (3) inputs. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5834-4
Honeywell 5834 4 wireless 4 button security key fob for honeywell security systems
Four (4) button key fob. Dual-button inputs allowed. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5834-4EN
Honeywell 5834 4en wireless enhanced 4 button security key fob
Four (4) button key fob. Dual-button inputs allowed. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5853
Honeywell 5853 wireless glass break detector exterior
Glass break sensor. Uses Loop 1.
Honeywell 5869
Honeywell 5869 wireless commercial panic switch
Commercial panic switch. Uses Loop 1. Latches when tripped, key (provided) needed to reset it after it is tripped
Honeywell 5878
Honeywell 5878 wireless remote alarm keypad
Six (6) button key fob. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible.
Honeywell 5898
Honeywell 5898 wireless dual tec motion detector
Dual-tec motion sensor.
Loop 1 = Low Sensitivity Motion Sensor. Pet immunity is available for this loop. 50lb or 100lb pet immunity, selectable via DIP Switch 1
Loop 2 = High Sensitivity Motion Sensor.
Loop 3 = Temperature Sensor (High or Low, DIP Switch Selectable)
Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

Hi DIYers! We're happy to announce that a new product is now available on our site. Introducing the Honeywell 5819S Wireless Shock Sensor and Transmitter. This device is great for any Honeywell or 2GIG user looking for a reliable shock sensor to monitor a door or window for forced entry.


The 5819S offers many great features that help to make it one of the premier wireless shock sensors on the market today. The device is omni-directional, meaning that it can be mounted from any position for reliable performance. This is very useful if you need to mount the sensor horizontally to fit it next to the bottom pane of a double-hung window. Please note that the sensor should not be mounted on the glass itself. The sensor offers four (4) distinct sensitivity levels for use as a shock sensor.

For detection range, the 5819S covers about 10 to 12 feet total. This is roughly a five (5) to six (6) foot radius from the sensor. The exact coverage area can differ due to the mounting surface. For shock detection, you will want to have the sensor programmed using Loop 1. The sensor has three loops in total. The other two (2) loops allow the programmed zone to function strictly as either a wireless contact or as a wireless transmitter for hardwired contacts. Loop 2 is for a contact, and Loop 3 is for a transmitter.

Loop 1 includes the option to have the programmed zone function as both a shock sensor and a wireless contact. This is enabled by setting DIP Switch 4 to ON. If you set DIP Switch 4 to OFF, then Loop 1 will function strictly as a shock sensor. You can also program the sensor to multiple zones using different Loop Numbers if desired. The sensor operates at 345 MHz, and it includes a small magnet for use as a door and window contact. The sensors operates at 345 MHz. LED lights assist with shock sensor testing.

The Honeywell 5819S is available for purchase now on the Alarm Grid site. If you have any questions about this sensor, please email us at support@alarmgrid.com.

Tags: , , , , ,