Honeywell 5800 Glass Break Detectors Posts

Posted By

Last week, we took a look at three of the best alarm panels in the industry. These were the Honeywell Lyric, the Qolsys IQ Panel 2 Plus, and the 2GIG GC3e. Today, we are checking out the sensors that you can add to support these systems. Here is our 2020 Security Sensor Buying Guide!

Sensors are accessories that are added to alarm systems to report specific activity. Each sensor has its own job of looking for a certain type of activity in its designated location. All of the sensors on a system communicate with a single centralized panel or hub. This panel is actively listening for any sensor that is triggered due to a potentially important system event. Adding new sensors is perhaps the best way to expand upon an existing system, and they make awesome gifts and stocking stuffers for the security enthusiast in your life.

Broadly speaking, sensors can be split into two main categories, which are security and life safety/environmental. Security sensors look for activity that suggests potentially unauthorized entry into a monitored and protected location, such as a door being opened, movement in a room where nobody is supposed to be present, or a window being broken. Life safety/environmental sensors look for activity associated with unwanted or potentially harmful conditions that affect the well-being of those in the area, such as a flood, an extreme temperature, a fire, or the presence of CO gas. We'll be taking a look at life safety/environmental sensors another time. Today, our focus is on security sensors.

Wireless Sensor Basics


Before we dive into specific security sensors for our top panel picks, we're going to start by giving you some general, generic information that can be applied to any sensor out there. First, understand that this post is focusing only on wireless sensors. These are almost always the sensors chosen for use with wireless alarm systems. Wired sensors can also technically be used with wireless panels but a converter module is almost always needed. Not to mention the fact that wireless sensors are significantly easier to install, especially for DIY users. The only time you will realistically see wired sensors used with a wireless panel is if a user is upgrading from an older wired system and bringing over their old wired sensors, or in new construction where a user wants to integrate the sensors in with the building. But if you're expanding upon a wireless system by getting new sensors, then the new sensors will almost certainly be wireless.

The important thing to remember when choosing wireless sensors for a wireless alarm panel is making sure the sensor is compatible with the system. It doesn't matter if a sensor has all the specs and features if it doesn't work with your panel! The way to determine compatibility is to look at the lineup that the sensor is from. Petty much every wireless sensor out there is part of a larger grouping of sensors that will all have the same compatibility.

To make it easier for you, we have the three panels we mentioned before (well, make that five, as the Qolsys IQ Panel 2 Plus actually comes in three versions), and all their compatible sensor lineups conveniently listed. We hope that this sheds some light on your options. The only caveat is that for any panel listed here that supports the Honeywell 5800 Sensors, we must be clear that this is only for the uni-directional sensors with one-way communication in the lineup. Any bi-directional Honeywell 5800 Sensors with two-way communication will not work with any of the aforementioned systems. The bi-directional Honeywell 5800 Sensors are only compatible with the Honeywell LYNX Touch and VISTA Systems, which were not included in our buying guides.

With that out of the way, here are compatible sensor lineups by system:

You will notice that some of the sensor groups listed above are italicized and underlined. That is done to identify the lineups of encrypted sensors. These encrypted sensors have special protection measures put in place to make them more secure and less prone to being hacked or defeated by malicious attacks. Encrypted sensors tend to have more restricted compatibility. They may follow a special enrollment process. Encrypted sensors often use bi-directional communication so that the sensor knows that it is actively paired with the system. Many encrypted sensors may only be paired with a single system at any given time, and the sensor will need to be deleted from its existing system before it will work with a new one.

It's okay to use non-encrypted sensors with your system, especially in zones that are less likely to trigger an alarm, like a second story window. Many users will opt to use a mixture of both encrypted and non-encrypted sensors. Other users feel comfortable using entirely non-encrypted sensors. It really comes down to your level of comfort. Non-encrypted sensors are secure in most situations, and they are still tricky to defeat. But going fully encrypted is recommended for anyone seeking maximum security. One tip if you do decide to go with some non-encrypted sensors is to avoid letting others know what wireless frequency your sensors use or what type of system you have installed. Knowing the frequency and the system being used makes it much easier for a savvy intruder to defeat a sensor.

Door & Window Alarm Sensors


Now that you know some basics that apply to almost all wireless sensors, let's start talking about specific types and models. Door and window sensors will let a system know when a door or window has been opened or closed. These are some of the most basic and easy to use sensors on a security system. These devices work by using a larger sensor portion and a smaller magnet portion. The sensor is placed on or inside the door or window frame, and the magnet is placed on or inside the moving portion of the door or window. When the door or window is opened, the magnet will move away from the sensor. This will trip a metal reed switch inside the sensor, which will tell the sensor to alert the system to the opened door or window. All of the sensors we've listed here follow that same method of operation.

Door and window sensors can be split into two (2) main categories. Surface-mount door and window sensors are mounted outside the door or window and its accompanying frame on the surface. The advantage to surface-mount door and window sensors is that they are very easy to install, and they can usually be mounted using double sided foam tape. But some users may not like how they are visible on the outside of the door or window. If you don't like the appearance of visible surface-mount door and window sensors, then you might instead consider recessed door and window sensors. A recessed door or window sensor is installed inside a door or window and its frame, so that it is hidden and cannot be seen from the outside. Recessed door and window sensors are more difficult and time-consuming to install, because you must drill holes in both the door or window and its accompanying frame. Whether you decide to use surface-mount door and window sensors, or recessed door and window sensors is up to you. Most DIY users and Alarm Grid customers in general will use surface-mount door and window sensors.

Now let's look at some door and window sensors.:

Sensor Name
Product Lineup
Compatibility Range
Encryption Installation
Notes
Honeywell SiXMINICT

Honeywell SiX Series Lyric 200 Nominal Feet 128-bit AES Surface-Mount Premier mini encrypted door/window Sensor for Lyric.
DSC PG9303

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Surface-Mount PowerG encrypted surface mount door/window sensor.
DSC PG9307

PowerG All IQ Panel 2 Plus
2,000 Feet Open Air 128-bit AES Recessed PowerG encrypted recessed door/window sensor.
2GIG DW10e

2GIG eSeries 2GIG GC3e 350 Nominal Feet 2GIG eSeries Encryption Surface-Mount Encrypted surface-mount sensor for 2GIG
2GIG DW20e

2GIG eSeries
2GIG GC3e
350 Nominal Feet 2GIG eSeries Encryption
Recessed Encrypted recessed sensor for 2GIG
Qolsys IQ DW Mini-S

Qolsys S-Line 319.5 MHz IQ2+ 600 Feet Open Air Qolsys S-Line Encryption Surface-Mount Encrypted surface-mount sensor for 319.5 MHz systems.
Qolsys IQ Recessed Door-S

Qolsys S-Line 319.5 MHz IQ 2+ 600 Feet Open Air Qolsys S-Line Encryption Recessed Encrypted recessed sensor for 319.5 MHz systems.
Honeywell 5818MNL

Honeywell
5800 Series
Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Recessed Non-Encrypted recessed door/window sensor for 345 MHz systems.
VERSA-2GIG

2GIG 345 MHz Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Surface-Mount Non-encrypted surface-mount sensor for 345 MHz systems.
VERSA-GE

Legacy GE 319.5 MHz IQ2+ 200 Nominal Feet None Surface-Mount Non-encrypted surface-mount sensor for 319.5 MHz systems.
VERSA-DSC

Legacy DSC 433 MHz IQ2+ 200 Nominal Feet None Surface-Mount Non-encrypted surface-mount sensor for 433 MHz systems.

We also want to share a selection of outdoor door and window sensors with you. These surface-mount contact sensors are specifically designed to withstand the conditions of an outdoor environment, including intense rain, wind, dust, and sunlight. You can see them listed below.

Sensor Name
Product Lineup
Compatibility
Range
Encryption
Installation Notes
Honeywell 5816OD

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Surface-Mount Outdoor contact sensor from 5800 Series.
DSC PG9312

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Surface-Mount PowerG Outdoor Contact Sensor.
2GIG DW30-345

2GIG 345 MHz Lyric, GC3e, 345 MHz IQ2+ 350 Nominal Feet None Surface-Mount Outdoor contact sensor from 2GIG 345 MHz series.

Motion Sensors


Motion sensors use passive infrared (PIR) technology to detect movement within the sensor's coverage area. This is done by looking for the changes in infrared (IR) energy that occur when a person, animal, or object comes within the sensor's field of view. Standard motion sensors are typically PIR only. These are appropriately called PIR motion sensors.

Some motion sensors will also use microwave technology in addition to PIR technology. This involves having the sensor send out microwave signals and seeing how the signals bounce off of objects in the area. Movement will change the pattern of these microwave signals, and the sensor will be able to detect this. These motion sensors that use both microwave and PIR are called Dual-Tech motion sensors. The purpose of using both PIR and microwave together is to prevent false alarms. A Dual-Tech motion sensor will only activate and alert the system if both its PIR sensor and its microwave sensor are triggered. A microwave sensor is not vulnerable to the same environmental issues that may cause a false activation on a PIR. You will not find a motion sensor that uses microwave technology without PIR detection, as microwave alone would result in too many false alarms without having PIR to confirm movement.

One feature that you will often see listed on a motion sensor is pet-immunity. A motion sensor that has been set up for pet immunity can be configured to not "look" in the areas close to the ground where pets and small animals walk. Instead, the motion sensor only looks in the areas higher up, where humans move while walking upright. A pet immune motion sensor is not impervious to small animals, and you must position it carefully so that it works as intended. Pet immune motion sensors normally have a weight limit, where animals under that weight limit should avoid triggering the sensor, assuming that the sensor is installed properly. Please note that most pet friendly motion sensors will require you to set the sensitivity for the sensor to the lowest possible setting.

When it comes to motion sensors, mounting them carefully is very important. A motion sensor may cause false alarms on the system if it is not installed properly. These sensors should not be facing any vents, air ducts, ceiling fans, or curtains that may cause the sensor to activate without any movement. If you are using the motion sensor for pet immunity, then it should also not be facing any furniture or stairwells that your pet could use to get within the sensor's field of view. You will likely want to perform a Walk Test of your motion sensor to make sure that it responds properly when movement is present, and does not respond due to other external factors when there is no movement. You should also have any pets participate in the Walk Test to ensure that pet immunity is working properly.

We recommend reading the following FAQs to learn more about motion sensors:

Below are some of the most popular motion sensors for our recommended systems:

Sensor Name Product Lineup
Compatibility Range
Encryption Coverage Area
Detection Type
Pet Immunity Notes
Honeywell SiXPIR

Honeywell SiX Series Lyric 300 Nominal Feet 128-bit AES 40 by 56 Feet
PIR Up to 80 lbs Encrypted PIR Motion for Lyric.
DSC PG9914

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Up to 39 Feet PIR Up to 85 lbs PowerG Encrypted PIR Motion.
DSC PG9984P

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Up to 50 Feet Dual-Tech Up to 40 lbs PowerG Encrypted Dual-Tech Motion.
2GIG PIR1e

2GIG eSeries 2GIG GC3e 350 Nominal Feet 2GIG eSeries Encryption
30 by 50 Feet PIR Up to 55 lbs Encrypted PIR Motion for 2GIG.
Honeywell 5800PIR-RES

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None 35 by 40 Feet PIR Up to 80 lbs Non-encrypted residential PIR motion for 345 MHz systems.
Honeywell 5800PIR-COM

Honeywell 5800 Series Lyric, GC3e, 345 MHz, IQ2+ 200 Nominal Feet None 60 by 80 Feet PIR None Non-encrypted commercial PIR motion for 345 MHz systems.
Honeywell 5898

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None 35 by 40 Feet for Pet Immunity Dual-Tech Up to 100 lbs Non-encrypted Dual-Tech motion for 345 MHz systems.
Qolsys IQ Motion-S

Qolsys S-Line 319.5 MHz IQ2+ 600 Feet Open Air Qolsys S-Line Encryption 30 by 40 Feet PIR Up to 40 lbs Non-encrypted PIR motion for 319.5 MHz systems.

There are also certain outdoor motion detection sensors that are better-suited for use in an outdoor environment. These outdoor motion sensor models are typically more expensive than indoor variants. You can see some of our most popular ones listed below:

Sensor Name
Product Lineup
Compatibility Range
Encryption Coverage Area
Detection Type
Pet Immunity Notes
DSC PG9994

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES Up to 30 Feet PIR Up to 40 lbs PowerG Outdoor PIR Motion Sensor
Honeywell 5800PIR-OD

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None 40 by 30 Feet PIR None Honeywell 5800 Series Outdoor Motion, 1st ed.
Honeywell 5800PIR-OD2

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None 40 by 30 Feet PIR None Honeywell 5800 Series Outdoor Motion, 2nd ed.
Optex FTN-RRIX

Legacy Interlogix 319.5 MHz IQ2+ 200 Nominal Feet None Up to 16.5 Feet PIR None Optex Fitlink Outdoor Motion Sensor for 319.5 MHz Systems
Optex FTN-RR2G

2GIG 345 MHz Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Up to 16.5 Feet PIR None Optex Fitlink Outdoor Motion Sensor for 345 MHz Systems.
Optex FTN-RRDS

Legacy DSC 433 MHz IQ2+ 200 Nominal Feet None Up to 16.5 Feet PIR None Optex Fitlink Outdoor Motion Sensor for 433 MHz Systems.

Glass Break Sensors

The last type of security sensors we will be discussing are glass break sensors. These sensors include built-in microphones, and they actively listen for the unique sound of glass breaking. Most of these sensors will need to hear both the high-pitched shattering sound of the glass breaking, as well as the low-pitched sound of an object striking against the glass in order to activate. This design choice is to prevent false alarms caused by similar sounds. Most users will use glass break sensors to monitor windows, but they have also been known to work effectively on protective glass display cases that store valuables, such as what you might find in jewelry stores or gun shops. Most types of glass will work with glass break sensors, though there are some exceptions. For example double and triple pane glass windows won't work reliably. The same is true for coated or "safety" glass. Refer to the manual for the exact glass break detector you are using to determine compatibility.

A single glass break detector can monitor multiple windows or display cases, as long as the glass it is monitoring is within its detection range, which is typically 15 to 25 feet. Any glass that is being monitored must have a direct line of sight with the sensor, with no obstacles blocking the path that sound will travel through. When testing your glass break sensors, it is strongly recommended that you us a glass break simulator. These devices will mimic the sound of the glass breaking and activate your glass break sensors without actually breaking any glass. Remember to refer the instructions of your glass break simulator for more information. When choosing a glass break simulator, it is best to use a simulator from the same manufacturer, if possible. We have a Honeywell Glass Break Simulator and a DSC Glass Break Simulator available on our website. If you get one of the 2GIG Glass Break Sensors mentioned in this buying guide, then the Honeywell Glass Break Simulator is best for testing. Otherwise, just match the manufacturer.

Below are some of our most popular glass break sensors:

Sensor Name
Product Lineup
Compatibility
Range
Encryption
Notes
Honeywell SiXGB

Honeywell SiX Series Lyric 300 Nominal Feet 128-bit AES SiX Series Glass Break Sensor for Lyric
DSC PG922

PowerG All IQ Panel 2 Plus 2,000 Feet Open Air 128-bit AES PowerG Glass Break Sensor
2GIG GB1e

2GIG eSeries 2GIG GC3e 350 Nominal Feet 2GIG eSeries Encryption Encrypted glass break sensor for 2GIG.
Honeywell 5853

Honeywell 5800 Series Lyric, GC3e, 345 MHz IQ2+ 200 Nominal Feet None Non-encrypted glass break sensor for 345 MHz systems.
Qolsys IQ Glass-S

Qolsys S-Line 319.5 MHz IQ2+ 600 Feet Open Air Qolsys S-Line Encryption Encrypted glass break sensor for 319.5 MHz systems.

Reach Out to Us!


Remember that you can reach out to us with any questions you might have about planning your system and determining sensor compatibility. The best way to contact us is to email support@alarmgrid.com. This is also a good email to use if you are interested in starting new alarm monitoring service with Alarm Grid. Our team checks for new email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

A great way to build out your Honeywell Lyric is with Honeywell 5800 Sensors. These are simple, 345 MHz wireless sensors that you can easily enroll with the system for security, life-safety, and environmental monitoring. They are perfect for expanding your system and making it more robust.

Honeywell lyric controller encrypted wireless security system

When you want to pair a Honeywell 5800 Sensor with the Lyric, the process is very straightforward. Put the Lyric in its auto-enrollment mode by choosing Security > Tools > enter Installer Code (default 4112) > Program > Zones > Add New > Serial Number. Make sure the RF Type on the right-hand side is set to 5800. Then activate the sensor either by faulting it or triggering its cover tamper switch. The Lyric should beep to confirm that it received a signal transmission. Then activate the sensor a second time to have the Lyric display the Serial Number. The third activation will confirm the Serial Number and return you to the screen where you can configure the zone settings.


Programming the zone settings for the sensor is actually quite simple. Depending on how you enrolled the sensor, you may need to adjust the Loop Number. This is almost always the case if you enrolled the sensor by activating its tamper switch. Refer to the instruction manual for the 5800 Sensor to determine which Loop Number to use.

The two (2) Zone Descriptors and the Device Type serve as the name for the sensor. You should choose a name that will help you identify the sensor, e.g. "Front Bedroom Motion Sensor", "South Hallway Door", etc. The Response Type determines how the system responds when the sensor is faulted. See our list of Lyric Response Types for more info.

Alarm Report should be set to Yes if you want the system to report out through AlarmNet to a Central Station if the zone causes an alarm on the system. That is an essential component of alarm monitoring services. Chime is optional, and it has the panel emit any one of several available sounds when the zone is faulted. Supervision tells the panel to look for an RF check-in signal from the sensor periodically to ensure that it is online. Click Save in the bottom-right after you finish adjusting the settings.


Keep in mind that only uni-directional (one-way) sensors from the Honeywell 5800 Series can be used with the Lyric. This leaves out bi-directional devices like the Honeywell 5800WAVE Siren, the Honeywell 5828 Keypad, and the Honeywell 5800RL Relay Module, so make sure you do not buy those for the Lyric. But you still have a lot of excellent sensors and security devices to choose from.

Below is a list of the Honeywell 5800 Sensors that you can use with the Honeywell Lyric:

Sensor Name
Notes
Honeywell 5800MINI
Honeywell 5800mini interior wireless door and window sensor
Door/Window sensor. Uses Loop 1.
Honeywell 5800PIR-RES
Honeywell 5800pir res wireless pet immune motion detector close up
PIR motion sensor. Uses Loop 1.
Coverage Area: 35' x 40'
Honeywell 5816
Honeywell 5816 wireless door window sensor
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5811
Honeywell 5811 wireless wafer thin door and window sensor
Door and window sensor. Uses Loop 1.
Honeywell 5800C2W
Honeywell 5800c2w hardwire to wireless system 9 zone conversion module
9-zone wired to wireless converter. Allows hardwired sensors to communicate with the Lyric as wireless devices. All zones use Loop 1 and a unique Serial Number ID.
Honeywell 5800CO
Honeywell 5800co wireless carbon monoxide detector
Carbon monoxide sensor.
Loop 1 = CO Detection
Loop 2 = End of Sensor Life (separate programming only required on TURBO and other V-Plex panels)
Honeywell 5800COMBO
Honeywell 5800combo smoke heat and co detector
Combination, smoke, heat, CO, and low-temperature sensor. Uses up to five (5) zones on the Lyric Panel. Has two (2) Serial Numbers for enrollment purposes.
Loop 1, SN 1 = Smoke/Heat Detection
Loop 2, SN 1 = Smoke/Heat Maintenance
Loop 3, SN 1 = Low Temperature Detection
Loop 1, SN 2 = CO Detection
Loop 2, SN 2 = End of Sensor Life (separate programming required only on TURBO and other V-Plex panels)
Honeywell 5800FLOOD
Honeywell 5800flood wireless flood and temperature sensor
Flood and temperature sensor.
Loop 1 = Low Temperature Detection
Loop 2 = High Temperature Detection
Loop 3 = Flood Detection
Honeywell 5800MICRA
Honeywell 5800micra wireless recessed window contact
Recessed window sensor. Uses Loop 1.
Honeywell 5800PIR
Honeywell 5800pir exterior of wireless motion detector
PIR motion sensor.
Loop 1 = Low Sensitivity Motion.
Loop 2 = High Sensitivity Motion.
Loop 3 = Low Temperature Detection
Coverage Area: 35' x 40'
Honeywell 5800PIR-COM
Honeywell 5800pir com exterior of wireless long range motion det
Commercial PIR motion sensor.
Loop 1 = Low Sensitivity Motion
Loop 2 = High Sensitivity Motion
Loop 3 = Low Temperature Detection
Coverage Area: 60' x 80'
Honeywell 5800PIR-OD
Honeywell 5800pir od wireless outdoor motion detector exterior
Outdoor PIR motion sensor. Uses Loop 1.
Honeywell 5800PIR-OD2
Outdoor PIR motion sensor. Uses Loop 1.
Honeywell 5800RP
Honeywell 5800rp wireless repeater
Wireless repeater for Honeywell 5800 Sensors. Does not require enrollment, but can be assigned a single zone for RF supervision, low-battery, AC loss, and RF jam detection. This is done using Serial Number 1 with Loop 1, with DIP Switch 2 set in the OFF position. Can also use up to four (4) separate zones for supervision when DIP Switch 2 is set to ON. This is required for UL installations.
Honeywell 5800RPS
Honeywell 5800rps wireless recessed door and window plunger sens
Recessed door/window sensor. Uses Loop 1.
Honeywell 5800SS1
Honeywell 5800ss1 exterior of wireless shock sensor
Shock sensor. Uses Loop 1.
Honeywell 5802MN
Honeywell 5802 wireless panic button
Medical alert button. Uses Loop 1.
Honeywell 5802MN2
Honeywell 5802mn2 wireless dual button medical alert
Medical alert button. Uses Loop 1.
Honeywell 5802WXT
Honeywell 5802wxt wireless panic button
Panic button. Uses Loop 1.
Honeywell 5802WXT-2
Honeywell 5802wxt 2 wireless dual button medical alert
Panic button. Uses Loop 1.
Honeywell 5806W3
Honeywell 5806w3 wireless smoke detector
Smoke detector. Uses Loop 1.
Honeywell 5808W3
Honeywell 5808w3 wireless smoke and heat detector
Smoke and heat detector.
Loop 1 = Smoke & Heat Detection
Loop 3 = Low Temperature Detection
Honeywell 5809
Honeywell 5809 wireless heat detector
Fixed temperature and rate-of-rise heat detector. Uses Loop 1. Alarm occurs when the temperature exceeds 135 degrees Fahrenheit, or when the temperature rises more than 15 degrees Fahrenheit per minute.
Honeywell 5809FXT
Honeywell 5809 wireless heat detector
Fixed temperature heat detector. Uses Loop 1. Alarm occurs when the temperature exceeds 135 degrees Fahrenheit.
Honeywell 5809SS
Honeywell 5809ss wireless fixed temperature slash ror heat detec
Fixed temperature and rate-of-rise heat detector. Uses Loop 1. Alarm occurs at 135 degrees Fahrenheit or when the temperature rises more than 15 degrees Fahrenheit per minute.
Honeywell 5814
Honeywell 5814 wireless small door sensor and window sensor
Door and window sensor. Uses Loop 1.
Honeywell 5815
Honeywell 5815 white wireless aesthetic door sensor and window s
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5816MN
Honeywell 5816mn wireless mini door sensor and window sensor
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switches
Honeywell 5816OD
Honeywell 5816od wireless outdoor door and window sensor top
Outdoor door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5817
Honeywell 5817 wireless three zone sensor
Three (3) zone door and window sensor & transmitter.
Loop 1 = NC or NO (DIP Switch Selectable) unsupervised. It does not use an End of Line Resistor (EOLR)
Loop 2, 3 = NC Only. Both are unsupervised with no EOLR used
Honeywell 5817CBXT
Honeywell 5817cb wireless commercial sensor
Three (3) zone commercial transmitter.
Loop 1 = Two (2) Terminals; Primary Loop supervised by 470k Ohm (yellow, purple, yellow, gold) EOLR. Resistor must ALWAYS be installed, even if Loop 1 is not programmed. If Loop 1 is used as a burglary zone, then Loop 4 must be programmed as a separate zone for Cover Tamper protection.
Loop 2 = NC Reed Switch
Loop 3 = Two (2) Terminals; NC Loop unsupervised, no EOLR required
Honeywell 5817XT
Honeywell 5817xt three zone universal transmitter
Three (3) zone door and window sensor & transmitter.
Loop 1 = NC or NO (DIP Switch Selectable) unsupervised with no EOLR required
Loop 2, 3 = Two (2) Terminal Blocks, NC Only
Honeywell 5818MNL
Honeywell 5818mnl wireless recessed door sensor and window senso
Recessed door and window sensor. Uses Loop 1. Not suitable for use in metal doors
Honeywell 5819
Honeywell 5819 wireless shock processor and sensor
Three (3) zone shock processor.
Loop 1 = NC for Inertia Style External Shock Sensor. This input provides a suitable fast loop response of from 1ms to 20ms, based on dip switch setting
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact, unsupervised with no EOLR required
Honeywell 5819S
Honeywell 5819s wireless shock sensor and transmitter
Shock sensor and contact sensor.
Loop 1 = Built-in Inertia Style Shock Sensor
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact
Honeywell 5819WHS
Honeywell 5819whs wireless transmitter with integrated shock sen
Three (3) zone shock processor.
Loop 1 = NC, Built-in Inertia Style Shock Sensor
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact
Honeywell 5820L
Honeywell 5820l super slim wireless door and window sensor
Slimline door and window sensor. Uses Loop 1.
Honeywell 5822T
Honeywell 5822t wireless garage tilt sensor
Garage tilt sensor.
Loop 1 = NC for Wired Contact, unsupervised, no EOLR used
Loop 3 = Tilt Switch
Honeywell 5834-2
Honeywell 5834 2 wireless 2 button security key fob
Two (2) button key fob. Dual-button inputs allowed. Uses three (3) loops total, for a possible three (3) inputs. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5834-4
Honeywell 5834 4 wireless 4 button security key fob for honeywell security systems
Four (4) button key fob. Dual-button inputs allowed. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5834-4EN
Honeywell 5834 4en wireless enhanced 4 button security key fob
Four (4) button key fob. Dual-button inputs allowed. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5853
Honeywell 5853 wireless glass break detector exterior
Glass break sensor. Uses Loop 1.
Honeywell 5869
Honeywell 5869 wireless commercial panic switch
Commercial panic switch. Uses Loop 1. Latches when tripped, key (provided) needed to reset it after it is tripped
Honeywell 5878
Honeywell 5878 wireless remote alarm keypad
Six (6) button key fob. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible.
Honeywell 5898
Honeywell 5898 wireless dual tec motion detector
Dual-tec motion sensor.
Loop 1 = Low Sensitivity Motion Sensor. Pet immunity is available for this loop. 50lb or 100lb pet immunity, selectable via DIP Switch 1
Loop 2 = High Sensitivity Motion Sensor.
Loop 3 = Temperature Sensor (High or Low, DIP Switch Selectable)
Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments