Posted By Michael GorisAlarm Grid is back with another video recap! This time, we have six (6) new videos to share. We spent a lot of time this week focusing on the 2GIG GC3e, but we also covered some other security equipment as well. We hope you enjoy this latest batch of videos. Let's check them out!
Properly Opening Up a 2GIG GC3e
I show you how to open up the 2GIG GC3e Security Panel. Before opening the system, you must loosen the set screw at the bottom. If the panel is wall-mounted, you can press the panel against the wall and lift upward. Otherwise, lay the panel face-down, and pop off the back plate using your finger or a screwdriver. Opening up the GC3e Panel is often done to access the system's terminal block and backup battery.
I show you how to power on the 2GIG GC3e Alarm System. The system uses a 14VDC, 1.7A transformer for primary power. If primary power is lost, then a backup battery will keep the system running. When powering on the 2GIG GC3e, we recommend connecting the backup battery first, followed by the transformer. Alarm wiring is not included with the 2GIG GC3e, so you must supply your own. We recommend using a Honeywell LT-Cable for this purpose.
Deleting a Defective Z-Wave Device from the GC3 or GC3e
I show you how to delete a defective Z-Wave device from a 2GIG GC3 or 2GIG GC3e. Some reasons why a Z-Wave device might be displayed as failed include the device being powered down or out of wireless range. Deleting a defective Z-Wave device is usually a good option if the device is lost or destroyed so that a traditional exclusion process cannot be performed. Any failed Z-Wave device will have an error icon next to it in the Smart Home Devices Menu.
Setting Up a Cellular Communicator for a 2GIG GC3e
I show you how to add a cellular communicator to a 2GIG GC3e Security System. Doing this will allow you to activate the 2GIG GC3e System for monitoring service. And if the monitoring plan includes access to Alarm.com, then you will also be able to control the system remotely through that platform. The 2GIG GC3e has a side slot for you to easily install a cellular radio. Remember to power down the system completely before installing the cellular communicator.
Powering the TG-1 Express Using the On-Board Terminals
I show you how you can power the Telguard TG-1 Express using its on-board power terminals. The Telguard TG-1 Express is used to take over the phone dialer for a panel so that it can communicate across a cellular network. Normally, the TG-1 uses a single RJ31X connection for power and communication with the panel. But if the existing power wires from the RJ31X cable are cut, then you can instead make the auxiliary power connections at the TG-1 on-board terminals.
Properly Closing the Qolsys IQ Panel 2
I show you how to properly close the Qolsys IQ Panel 2 Security System. To properly close the system, you want to align the top tabs first. Then you should lock the bottom two (2) tabs into place. Lastly, make sure the top four (4) tabs remain closed, and click them into place if they are not. The panel will make a strange noise every half-hour if it is not closed properly. The main reason to open the IQ2 is to replace its backup battery every few years.