A great way to build out your Honeywell Lyric is with Honeywell 5800 Sensors. These are simple, 345 MHz wireless sensors that you can easily enroll with the system for security, life-safety, and environmental monitoring. They are perfect for expanding your system and making it more robust.

Honeywell lyric controller encrypted wireless security system

When you want to pair a Honeywell 5800 Sensor with the Lyric, the process is very straightforward. Put the Lyric in its auto-enrollment mode by choosing Security > Tools > enter Installer Code (default 4112) > Program > Zones > Add New > Serial Number. Make sure the RF Type on the right-hand side is set to 5800. Then activate the sensor either by faulting it or triggering its cover tamper switch. The Lyric should beep to confirm that it received a signal transmission. Then activate the sensor a second time to have the Lyric display the Serial Number. The third activation will confirm the Serial Number and return you to the screen where you can configure the zone settings.


Programming the zone settings for the sensor is actually quite simple. Depending on how you enrolled the sensor, you may need to adjust the Loop Number. This is almost always the case if you enrolled the sensor by activating its tamper switch. Refer to the instruction manual for the 5800 Sensor to determine which Loop Number to use.

The two (2) Zone Descriptors and the Device Type serve as the name for the sensor. You should choose a name that will help you identify the sensor, e.g. "Front Bedroom Motion Sensor", "South Hallway Door", etc. The Response Type determines how the system responds when the sensor is faulted. See our list of Lyric Response Types for more info.

Alarm Report should be set to Yes if you want the system to report out through AlarmNet to a Central Station if the zone causes an alarm on the system. That is an essential component of alarm monitoring services. Chime is optional, and it has the panel emit any one of several available sounds when the zone is faulted. Supervision tells the panel to look for an RF check-in signal from the sensor periodically to ensure that it is online. Click Save in the bottom-right after you finish adjusting the settings.


Keep in mind that only uni-directional (one-way) sensors from the Honeywell 5800 Series can be used with the Lyric. This leaves out bi-directional devices like the Honeywell 5800WAVE Siren, the Honeywell 5828 Keypad, and the Honeywell 5800RL Relay Module, so make sure you do not buy those for the Lyric. But you still have a lot of excellent sensors and security devices to choose from.

Below is a list of the Honeywell 5800 Sensors that you can use with the Honeywell Lyric:

Sensor Name
Notes
Honeywell 5800MINI
Honeywell 5800mini interior wireless door and window sensor
Door/Window sensor. Uses Loop 1.
Honeywell 5800PIR-RES
Honeywell 5800pir res wireless pet immune motion detector close up
PIR motion sensor. Uses Loop 1.
Coverage Area: 35' x 40'
Honeywell 5816
Honeywell 5816 wireless door window sensor
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5811
Honeywell 5811 wireless wafer thin door and window sensor
Door and window sensor. Uses Loop 1.
Honeywell 5800C2W
Honeywell 5800c2w hardwire to wireless system 9 zone conversion module
9-zone wired to wireless converter. Allows hardwired sensors to communicate with the Lyric as wireless devices. All zones use Loop 1 and a unique Serial Number ID.
Honeywell 5800CO
Honeywell 5800co wireless carbon monoxide detector
Carbon monoxide sensor.
Loop 1 = CO Detection
Loop 2 = End of Sensor Life (separate programming only required on TURBO and other V-Plex panels)
Honeywell 5800COMBO
Honeywell 5800combo smoke heat and co detector
Combination, smoke, heat, CO, and low-temperature sensor. Uses up to five (5) zones on the Lyric Panel. Has two (2) Serial Numbers for enrollment purposes.
Loop 1, SN 1 = Smoke/Heat Detection
Loop 2, SN 1 = Smoke/Heat Maintenance
Loop 3, SN 1 = Low Temperature Detection
Loop 1, SN 2 = CO Detection
Loop 2, SN 2 = End of Sensor Life (separate programming required only on TURBO and other V-Plex panels)
Honeywell 5800FLOOD
Honeywell 5800flood wireless flood and temperature sensor
Flood and temperature sensor.
Loop 1 = Low Temperature Detection
Loop 2 = High Temperature Detection
Loop 3 = Flood Detection
Honeywell 5800MICRA
Honeywell 5800micra wireless recessed window contact
Recessed window sensor. Uses Loop 1.
Honeywell 5800PIR
Honeywell 5800pir exterior of wireless motion detector
PIR motion sensor.
Loop 1 = Low Sensitivity Motion.
Loop 2 = High Sensitivity Motion.
Loop 3 = Low Temperature Detection
Coverage Area: 35' x 40'
Honeywell 5800PIR-COM
Honeywell 5800pir com exterior of wireless long range motion det
Commercial PIR motion sensor.
Loop 1 = Low Sensitivity Motion
Loop 2 = High Sensitivity Motion
Loop 3 = Low Temperature Detection
Coverage Area: 60' x 80'
Honeywell 5800PIR-OD
Honeywell 5800pir od wireless outdoor motion detector exterior
Outdoor PIR motion sensor. Uses Loop 1.
Honeywell 5800PIR-OD2
Outdoor PIR motion sensor. Uses Loop 1.
Honeywell 5800RP
Honeywell 5800rp wireless repeater
Wireless repeater for Honeywell 5800 Sensors. Does not require enrollment, but can be assigned a single zone for RF supervision, low-battery, AC loss, and RF jam detection. This is done using Serial Number 1 with Loop 1, with DIP Switch 2 set in the OFF position. Can also use up to four (4) separate zones for supervision when DIP Switch 2 is set to ON. This is required for UL installations.
Honeywell 5800RPS
Honeywell 5800rps wireless recessed door and window plunger sens
Recessed door/window sensor. Uses Loop 1.
Honeywell 5800SS1
Honeywell 5800ss1 exterior of wireless shock sensor
Shock sensor. Uses Loop 1.
Honeywell 5802MN
Honeywell 5802 wireless panic button
Medical alert button. Uses Loop 1.
Honeywell 5802MN2
Honeywell 5802mn2 wireless dual button medical alert
Medical alert button. Uses Loop 1.
Honeywell 5802WXT
Honeywell 5802wxt wireless panic button
Panic button. Uses Loop 1.
Honeywell 5802WXT-2
Honeywell 5802wxt 2 wireless dual button medical alert
Panic button. Uses Loop 1.
Honeywell 5806W3
Honeywell 5806w3 wireless smoke detector
Smoke detector. Uses Loop 1.
Honeywell 5808W3
Honeywell 5808w3 wireless smoke and heat detector
Smoke and heat detector.
Loop 1 = Smoke & Heat Detection
Loop 3 = Low Temperature Detection
Honeywell 5809
Honeywell 5809 wireless heat detector
Fixed temperature and rate-of-rise heat detector. Uses Loop 1. Alarm occurs when the temperature exceeds 135 degrees Fahrenheit, or when the temperature rises more than 15 degrees Fahrenheit per minute.
Honeywell 5809FXT
Honeywell 5809 wireless heat detector
Fixed temperature heat detector. Uses Loop 1. Alarm occurs when the temperature exceeds 135 degrees Fahrenheit.
Honeywell 5809SS
Honeywell 5809ss wireless fixed temperature slash ror heat detec
Fixed temperature and rate-of-rise heat detector. Uses Loop 1. Alarm occurs at 135 degrees Fahrenheit or when the temperature rises more than 15 degrees Fahrenheit per minute.
Honeywell 5814
Honeywell 5814 wireless small door sensor and window sensor
Door and window sensor. Uses Loop 1.
Honeywell 5815
Honeywell 5815 white wireless aesthetic door sensor and window s
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5816MN
Honeywell 5816mn wireless mini door sensor and window sensor
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switches
Honeywell 5816OD
Honeywell 5816od wireless outdoor door and window sensor top
Outdoor door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5817
Honeywell 5817 wireless three zone sensor
Three (3) zone door and window sensor & transmitter.
Loop 1 = NC or NO (DIP Switch Selectable) unsupervised. It does not use an End of Line Resistor (EOLR)
Loop 2, 3 = NC Only. Both are unsupervised with no EOLR used
Honeywell 5817CBXT
Honeywell 5817cb wireless commercial sensor
Three (3) zone commercial transmitter.
Loop 1 = Two (2) Terminals; Primary Loop supervised by 470k Ohm (yellow, purple, yellow, gold) EOLR. Resistor must ALWAYS be installed, even if Loop 1 is not programmed. If Loop 1 is used as a burglary zone, then Loop 4 must be programmed as a separate zone for Cover Tamper protection.
Loop 2 = NC Reed Switch
Loop 3 = Two (2) Terminals; NC Loop unsupervised, no EOLR required
Honeywell 5817XT
Honeywell 5817xt three zone universal transmitter
Three (3) zone door and window sensor & transmitter.
Loop 1 = NC or NO (DIP Switch Selectable) unsupervised with no EOLR required
Loop 2, 3 = Two (2) Terminal Blocks, NC Only
Honeywell 5818MNL
Honeywell 5818mnl wireless recessed door sensor and window senso
Recessed door and window sensor. Uses Loop 1. Not suitable for use in metal doors
Honeywell 5819
Honeywell 5819 wireless shock processor and sensor
Three (3) zone shock processor.
Loop 1 = NC for Inertia Style External Shock Sensor. This input provides a suitable fast loop response of from 1ms to 20ms, based on dip switch setting
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact, unsupervised with no EOLR required
Honeywell 5819S
Honeywell 5819s wireless shock sensor and transmitter
Shock sensor and contact sensor.
Loop 1 = Built-in Inertia Style Shock Sensor
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact
Honeywell 5819WHS
Honeywell 5819whs wireless transmitter with integrated shock sen
Three (3) zone shock processor.
Loop 1 = NC, Built-in Inertia Style Shock Sensor
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact
Honeywell 5820L
Honeywell 5820l super slim wireless door and window sensor
Slimline door and window sensor. Uses Loop 1.
Honeywell 5822T
Honeywell 5822t wireless garage tilt sensor
Garage tilt sensor.
Loop 1 = NC for Wired Contact, unsupervised, no EOLR used
Loop 3 = Tilt Switch
Honeywell 5834-2
Honeywell 5834 2 wireless 2 button security key fob
Two (2) button key fob. Dual-button inputs allowed. Uses three (3) loops total, for a possible three (3) inputs. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5834-4
Honeywell 5834 4 wireless 4 button security key fob for honeywell security systems
Four (4) button key fob. Dual-button inputs allowed. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5834-4EN
Honeywell 5834 4en wireless enhanced 4 button security key fob
Four (4) button key fob. Dual-button inputs allowed. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5853
Honeywell 5853 wireless glass break detector exterior
Glass break sensor. Uses Loop 1.
Honeywell 5869
Honeywell 5869 wireless commercial panic switch
Commercial panic switch. Uses Loop 1. Latches when tripped, key (provided) needed to reset it after it is tripped
Honeywell 5878
Honeywell 5878 wireless remote alarm keypad
Six (6) button key fob. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible.
Honeywell 5898
Honeywell 5898 wireless dual tec motion detector
Dual-tec motion sensor.
Loop 1 = Low Sensitivity Motion Sensor. Pet immunity is available for this loop. 50lb or 100lb pet immunity, selectable via DIP Switch 1
Loop 2 = High Sensitivity Motion Sensor.
Loop 3 = Temperature Sensor (High or Low, DIP Switch Selectable)
Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

Hi DIYers! Today, we're taking a look at why one-go-all-go smoke detectors can help ensure that everyone in the building is alerted during a fire. Simply put, a one-go-all-go smoke detector will cause all of the other compatible smoke detectors on the system to activate at the same time.

Dsc fsb 210bt 2 wire addressable photoelectric smoke and heat de

Having all the smokes in your home activate at the same time can be crucial for ensuring that everyone is alerted in the event of a fire. This is especially true for larger homes that need several smoke detectors for complete coverage. Most alarm systems can have some type of interconnected one-go-all-go smoke detector network. However, implementing this feature properly can be difficult, and it requires additional equipment and wiring. Another important thing to remember is that the one-go-all-go feature is best achieved by using the same detector model across the network.

For those with wired alarm control panels, there is often a way to achieve a one-go-all-go setup using hardwired smokes. This is possible with both 2-wire smokes and 4-wire smokes, but both require the proper equipment. Many wired panels offer a way to conveniently reset the zone used for 2-wire smokes after a fire alarm has been cleared. This is needed for getting the smoke detectors to stop sounding and to reset the detector so that it can trip again, if necessary.

For the Honeywell VISTA Panels, all 2-wire smokes must go on zone 1. This zone will automatically reset, and power will be briefly dropped to the smokes after the alarm is cleared. Multiple 2-wire smokes are wired together in parallel, with an end of line resistor (EOLR) for wiring supervision. A good 2-wire smoke detector to use is the System Sensor 2WTA-B, which also includes a built-in sounder.

System sensor 2wta b 2 wire smoke detector with fixed heat and s

Unlike 2-wire smokes, 4-wire smokes have less restriction regarding where they can be wired. In fact, a 4-wire smoke on a Honeywell VISTA System will generally go on any hardwired zone, except for zone 1. Again, the smokes can be configured for a one-go-all-go setup, but this will require additional equipment and wiring. This also allows the smokes to take up fewer systems zones, as they can all use the same zone and programming settings.

One downside to using 4-wire smokes is that they often require additional resources to work properly. In order to get a 4-wire smoke to stop sounding, power to the device must be dropped. But unless the system has a built-in relay, this cannot be done without additional hardware. This can require an external relay, and possibly an additional power supply as well. Proper operation will also require an end-of-line power supervision relay to check whether or not power to the smokes has been interrupted. If you do decide to go the 4-wire route, the System Sensor 4WTA-B is a good option.

System sensor 4wt b 4 wire smoke detector with fixed heat sensor

More recently, certain wireless smoke detectors also offer one-go-all-go functionality. Honeywell really took the initiative here by making their Lyric SiXSMOKE Sensor a one-go-all-go device. This sensor is exclusively compatible with the Honeywell Lyric Alarm System, and provides a very easy way to achieve a robust one-go-all-go setup. One-go-all-go is also compatible with the new Honeywell SiXCOMBO, which also offers heat and CO detection.

Honeywell sixsmoke front wireless smoke slash heat detector for

If you have a different wireless system than the Lyric, then there might still be way to attain a one-go-all-go setup. In most cases, this will require using 4-wire smokes with a compatible wireless transmitter. The transmitter will need to be able to support Normally Open (NO) life-safety devices with an end of line resistor. However, this is not possible for every wired-to-wireless converter.

Additionally the standard equipment for any 4-wire smoke is also required. This includes a relay, power supply and resistor. One transmitter that will work for this application is the Honeywell 5817CBXT. This module is part of the Honeywell 5800 Series, and it will work with nearly any alarm system that accepts the 345 MHz wireless frequency. Remember, the transmitter or converter must communicate at a frequency accepted by the alarm control panel.

Honeywell 5817cb wireless commercial sensor

Additionally, Qolsys recently released the Qolsys IQ Hardwire 16-F for 319.5 MHz systems. This is a 16-zone wired to wireless converter that is great for bringing over hardwired sensors to a newer wireless system. Zone 16 on the module is a Normally Open loop specifically designed for 2-wire smokes. The loop will support up to ten 2-wire smoke devices, which are wired in parallel with an end-of-line resistor. This revolutionary module represents the first way to bring 2-wire smokes over to a wireless all-in-one system. The necessary resistors come included with the module.

Qolsys iq hardwire 16 s qs7131 840

Additionally, if you have an existing network of high-voltage smokes, you can integrate them into a wireless system using a takeover module. These are devices that listen for the unique temporal sound of an activated smoke detector. If the existing smoke detector network is one-go-all-go, a single takeover module can accommodate the entire network. Alarm Grid offers takeover modules that operate at the 319.5 MHz (Interlogix/GE and Qolsys), 345 MHz (Honeywell and 2GIG) and 433 MHz (DSC) wireless frequencies. That way, you can conveniently take an exiting high-voltage smoke network and start using it with your new wireless security system!

If you need help choosing smoke detectors for a one-go-all-go setup, please don't hesitate to reach out to us! We can help you determine the perfect fire-protection devices for your security system. You can send an email to support@alarmgrid.com, or you can call us at (888) 818-7728 during our normal business hours of 9am to 8pm EST M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , , , ,

Comments