Qolsys IQ Panel 2 Plus AT&T LTE, DSC Compatible Posts

Posted By

If you have been keeping up with Z-Wave home automation lately, then you have likely at least heard about the S2 Security Protocol. The security suite offers an advanced level of protection to keep smart home devices safe. Today, we're checking out the S2 Protocol to learn more about it.


Before we get into the specifics of Security 2 (S2), it is important to understand which Z-Wave setups will support it. In order to achieve a proper S2 setup, the Z-Wave controller and the paired device itself must both support the S2 Protocol. If either end is not S2-compatible, then the protocol will not be used. If you pair a non-S2 device with a controller that supports S2, then the device will simply pair using the S0 Protocol instead. Likewise if you have a hub that does not support S2, then none of the devices on the network will use S2, including those that technically are capable of supporting the protocol. Not to worry, if you do have an S2-compatible controller, then it is certainly possible to have a mixture of S2 and S0 devices on the same Z-Wave network.

The S2 Security Protocol is optional for 500-Series Z-Wave Plus devices and hubs. In other words, some 500-Series Z-Wave Plus smart home devices and controllers will support S2, while others will not. You need to check the specifications for the exact device and hub that you are working with to see if it is supported. In some cases, it may be possible to perform an over-the-air (OTA) update for a 500-Series accessory or controller so that it can support the S2 protocol, even if it did not previously. An example of this is when you upgrade the Z-Wave firmware on the Qolsys IQ Panel 2 Plus to Version 6.81.03. That is the first Z-Wave firmware version for the system that supports S2. Older versions do not. The panel firmware should be on version 2.5.3 or higher when using S2.

But for 700-Series Z-Wave Plus V2 equipment, support for S2 is required. In order for a device or hub to be certified as 700-Series by the Z-Wave Alliance, it must support the S2 Protocol. Therefore, if you see equipment listed as 700-Series, then you will know for certain that the technology is supported. As of October 2020, we have not seen many Z-Wave Plus V2 controllers or devices available. One 700-Series device that is available now is the 2GIG STZ-1 Thermostat. We hope that more 700-Series equipment will be hitting the market soon.

Looking at what S2 actually entails, you should understand that it isn't just one aspect or factor that makes the protocol what it is. There are many different components coming together to create a single protocol that is extremely secure. But perhaps the single most crucial aspect of S2 is that it is readily built into the Z-Wave framework for use by software developers. This makes it very easy for a developer to implement the technology into any given Z-Wave Plus device. Prior to the introduction of S2, there was no security built into the Z-Wave framework. The only option for a developer was to implement their own security protocol, and this was completely optional. Many develops would elect not to provide any security and just leave automation devices vulnerable. But when a device is listed as S2, you can be absolutely certain that it is meeting an advanced standard of security and protection.

Just like many other secure protocols, S2 makes use of an asymmetric key exchange, which at the simplest level involves a public key and a private key. Any command can be encrypted using the public key, but only the specific private key can unlock it. This ever-crucial private key is protected using Elliptic Curve Diffie-Hellman (ECDH) technology. Thanks to this advanced method, the task of deciphering the key is all but impossible. Additionally, different devices on the same network can be separated into different groups. Each device group can be assigned its own set of encryption keys. Often, devices that require greater security, such as door locks, are included with more secure groups that also require authentication during the network inclusion process. Meanwhile, the support of a highly secure TLS 1.1 Tunnel for all Z-Wave Over IP (Z/IP) traffic removes almost any possibility of cloud vulnerability. For the record, the S2 Protocol is rated at 128-bit AES in terms of overall security level.

One other big factor for the S2 Protocol is that it makes use of a single-frame transmission, which is a massive improvement over the three-frame transmission used by the S0 Protocol. Simply put, single-frame transmission is significantly more efficient than three-frame transmission. The improvement in efficiency allows for extended battery life, enhanced reliability, and a huge cut-down on latency. This means that a device using S2 technology will require less maintenance, including fewer battery changes. It will provide more consistent performance, and experience shorter operation delays. This alone makes S2 vital for anyone looking to achieve the most efficient automation network possible.

Understanding this technology in advanced detail may seem a bit daunting. But you just need to know that S2 makes Z-Wave home automation more secure, faster, and more efficient than ever before. If you have any further questions about S2, or if you want some tips for getting started with home automation, please email us at support@alarmgrid.com. We check our email from 9am to 8pm Eastern Time M-F. Also remember to check our monitoring page if you are interested in learning more about the monitoring services we offer. We look forward to hearing from you!

Tags: , , , , , , , , , , ,

Comments


Posted By

As security professionals, we often encounter myths regarding security systems. There is a lot of untrue information out there, so we figured it would be a good idea to debunk a few security system myths to help end users understand the facts. Here are three false security system myths.


Myth #1 - Only Professionals Can Install a Security System

There was once a time when security systems were hardwired, and it was virtually impossible for a DIY user to install one. But with the rise of wireless alarm panels, many security systems can be installed using nothing more than a screwdriver. An end user can install their own system, program their own sensors, and get their system activated for monitoring service. Most wireless alarm panels even support desk mounts that allow a user to install a system without drilling holes in the walls. This can help a user save a lot of money by not having to hire a professional installer.

Myth #2 - Wireless Security Systems Are Not Secure

When wireless security systems first hit the market, many were easily defeated by third party devices. An intruder could block the signals from wireless sensors and prevent them from reaching the panel. They could also send false signals to the panel to make it appear as though a break-in was occurring, when really nothing was happening. But most modern wireless panels support encryption to prevent this from happening. This makes foul play all but impossible. There are many encrypted sensor options to choose from, including the Honeywell SiX Series Sensors for the Honeywell Lyric, the PowerG Sensors for the Qolsys IQ Panel 2 Plus, and the eSeries Sensors for the 2GIG GC3e.

Honeywell sixminict wireless door slash window contact for lyric

Myth #3 - Security Systems Only Perform Security Functions

When shopping for a security system, many buyers only consider the security aspects. The reality is that a modern security system does so much more than just keep you and those around you safe. Nearly every security system on the market today also offers smart home automation capabilities. You can pair a variety of smart home devices with your system, including smart lights, door locks, programmable thermostats, and more. You can then control these devices from the panel and have them activate automatically with programmed smart scenes. And if your system is monitored, then you can control the devices from anywhere using a web browser or a mobile app on your phone.


Security systems today are more powerful and easier to use than ever before. Now is a great time to get started with a new security system for your home or business. Check out this post to learn more about the monitoring plans offered by Alarm Grid. If you're interested in getting started, then please email us at support@alarmgrid.com for more information. Our team checks email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , ,

Comments


Posted By

If you're using a newer wireless security system, then you will definitely want to explore the encrypted sensor options that we offer! Encrypted sensors are virtually impossible to hack, and they can make your security system even more secure. There are many great options available.

Honeywell sixminictpk5 a 5 pack of sixminict encrypted wireless

As you know, a home security system or a business security system is an investment you make for the protection of yourself, your property, and those around you. A proper system should also give you peace of mind and make you feel safe. It doesn't do you any good if an intruder manages to defeat your system. But with encrypted sensors, that is extremely unlikely to ever happen.

If you aren't familiar with encryption, it refers to techniques for encoding data and signals so that only authorized individuals and/or equipment are able to access the information. When it comes to wireless alarm systems, encrypted sensors send protected signals that can only be accessed, received, and interpreted by the authorized panel.

When wireless systems first rose to prominence, they rarely, if ever, used encryption. This made many people wary of wireless security panels, and they felt more secure using wired ones. The lack of encryption wasn't seen as a fatal flaw, as an intruder would have to be extremely savvy and really know what they're doing to defeat even a non-encrypted sensor. To this day, many people feel totally comfortable and safe using non-encrypted equipment. Remember, most intruders don't have the knowledge to beat wireless sensors, even if they aren't using encryption.

But there are the rare, professional criminals who do take the time to extensively study security equipment, and they develop techniques for beating non-encrypted devices. This is very uncommon, but it's not unheard of. And if you aren't using encrypted sensors, then you are leaving yourself open to this small risk. Whether or not that means outfitting your system with all-new encrypted sensors, or even upgrading to a different system that is capable of supporting encrypted sensors is up to you. We just want to make you aware of your options.

Today, we're going to briefly look at some popular wireless systems and explore their encrypted sensor options, as well as their non-encrypted sensor lineups. This will help you learn more about your system, or one you are considering for purchase.


Honeywell Lyric Controller

Honeywell lyric controller encrypted wireless security system


The Lyric represents the first the first encrypted panel from Resideo, formerly known as Honeywell. The system has its very own lineup of encrypted sensors called the Honeywell SiX Series Sensors. The lineup is a bit limited, as its lacking options like an outdoor door and window sensor and a curtain motion sensor. But the good news is that these sensors are extremely secure with their military grade 128-bit AES encryption.

You can supplement your SiX Series Sensors on your Lyric System with devices from the Honeywell 5800 Series. These sensors are not encrypted, but the lineup offers more diverse selection than the SiX Series lineup. You could consider using encrypted sensors for the most vulnerable parts of your home or office, while using non-encrypted 5800 Series devices for areas where it isn't as important. The non-encrypted 2GIG 345 MHz Sensors are also compatible with the Lyric once the system is on Firmware Version MR3 or higher.


Qolsys IQ Panel 2 Plus

Qolsys iq panel 2 plus verizon lte with powerg s line and legacy


There are some outstanding encryption options available for the Qolsys IQ Panel 2 Plus, regardless of which version you have. Any IQ Panel 2 Plus System can readily support DSC PowerG Sensors. Not only do these sensors have an outstanding wireless range of up to 2,000 feet away from the IQ Panel 2 Plus, they also utilize military grade 128-bit AES encryption and Frequency Hopping Spread Spectrum (FHSS) technology.

And if you have the 319.5 MHz Version of the Qolsys IQ Panel 2 Plus, then you can also pair Qolsys S-Line Sensors, which use rolling code encryption. This rolling code encryption isn't quite as secure as the encryption used by PowerG Sensors, but it still does a good job of keeping your system protected. The S-Line Sensors will also utilize encryption when paired with the original Qolsys IQ Panel 2. The original IQ Panel 2 cannot use PowerG Sensors.

In terms of non-encrypted options, each IQ Panel 2 Plus can support one of three (3) non-encrypted radio frequency signals. The available options are 319.5 MHz, 345 MHz, and 433 MHz, and it is dependent upon which version of the IQ Panel 2 Plus you buy. Again, it is certainly possible to mix encrypted sensors with non-encrypted sensors on the same system. But with the diversity and selection of the PowerG lineup, you probably won't need to look outside too much.


2GIG GC3e

2gig gc3e wireless encrypted alarm panel


The big highlight when the 2GIG GC3e was introduced was its ability to support encrypted sensors. While it took a little while before its encrypted sensor lineup became available, we were very pleased with the result. The 2GIG eSeries Sensors use highly secure encryption to keep your system protected. It also seems that 2GIG is regularly expanding upon this lineup, as we have been seeing new eSeries Sensors hit the market it recent times. All of the 2GIG eSeries Sensors are compatible with the GC3e, as well as its little brother, the GC2e.

With the GC3e, you also get access to the Honeywell 5800 Sensors and the 2GIG 345 MHz lineup. Just like with the Lyric, there is a bit more of a diverse selection of non-encrypted sensors available for the 2GIG GC3e. You can definitely set up a mixture of encrypted and non-encrypted sensors to meet the needs of your business. But with new 2GIG eSeries offerings continuing to become available, you shouldn't have much trouble building a fully encrypted 2GIG Security System.


Alarm grid inside security stickers

If you are looking to set up an encrypted security system, then Alarm Grid is here to help! We can let you know if your existing system has any encrypted sensor options available. We can also help you determine if you are currently using encrypted devices or if your existing sensors are non-encrypted. Many users have trouble determining. Either way, we'll help you make an informed decision so that you can get the most out of your monitoring service. If you want to reach us, please email support@alarmgrid.com. We check our email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

While checking out Firmware Version 2.5.3 for the Qolsys IQ Panel 2 Plus, we came across the Smart Energy Optimizer feature, and we figured we'd take a closer look. From what we can tell, this feature looks to be a nice way to set up automation rules for lighting devices right from the IQ2.



As you can see from the above picture, the option is found conveniently within the Settings Menu for the system. Simply click on the small grey bar at the top of the screen, and then choose Settings. You should see the Smart Energy Optimizer option with the Tree icon in the bottom-left corner. In order to enter this menu, you must have at least one compatible Z-Wave device enrolled with the system. If you try to enter the menu without a Z-Wave device being enrolled, then you will not gain access.

Once you are in the menu, you can set compatible lights to turn ON/OFF or to DIM to a set level during peak hours that you can set on the panel. You can set both the month and the hour of the day when "peak" consumption goes into effect for energy savings. You can also choose whether the automatic adjustments will only be applied to weekends (Saturday and Sunday). It's all customizable. We're sure Qolsys is going to continue developing this feature.


Based on the settings we have shown above, our light is set to automatically DIM to a 52% level between the months of June to September, during the hours of 2pm to 5pm, with the weekends set as the peak. Of course, you can set your compatible light or dimmer switch however you want. The time setting is expressed in 24-hour "military time", so keep that in mind when setting your values. For our testing, we used the Qolsys IQ Dimmer. The dimmer level bar is a bit flimsy and difficult to adjust, so we're hoping Qolsys makes it a bit easier to control in a future update. But for now, 52% is close enough to half-level that we're happy.

We're still exploring the feature, so we'll let you know if we find out anything else. For now though, it looks like a nifty little way that you can automate your smart lights directly from your Qolsys IQ Panel 2 Plus System! If you have any questions about the feature, or if you want to learn more about alarm monitoring, send an email to support@alarmgrid.com. We're here to check email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , ,

Comments


Posted By

After much anticipation Firmware Version 2.5.3 for the Qolsys IQ Panel 2 Plus is now available! This update brings support for the PowerG Wired to Wireless Converter, as well as some other new features. Everyone with an IQ Panel 2 is encouraged to download the update as soon as possible.

Qolsys iq panel 2 plus verizon lte with powerg s line and legacy

Support for the DSC PG9WLSHW8 PowerG Wired to Wireless Converter is the biggest new addition for Firmware Version 2.5.3. We covered the PowerG Wired to Wireless Converter extensively in a post last month. But just as a quick recap, the device allows to you to connect hardwired sensors so that they can communicate with the IQ Panel 2 Plus wirelessly across the PowerG protocol. This is an excellent way to upgrade from an older hardwired system, as it can prevent you from having to purchase entirely new wireless sensors.

The PG9WLSHW8 also includes all the benefits of PowerG. This includes a wireless range of up to 2,000 feet away from the IQ2+ in an open air environment, military grade 128-bit AES encryption, and Frequency Hopping Spread Spectrum (FHSS) technology for added protection. Up to eight (8) hardwired zones are built into a single converter, and you can use up to two (2) of the PG9WLSHW8 units per IQ2+ System. The unit even offers support for 2-wire or 4-wire smoke detectors, plus a 700mA supervised output for adding a wired siren.


Of course, IQ Panel 2 Firmware Version 2.5.3 includes a huge bundle of other new features and functions. Even if you don't plan on adding a DSC PG9WLSHW8 unit, there are still many other reasons to receive the upgrade. We'll touch on all the other new additions below.

The IQ2 system now has Panel Ambient Noise Detector settings to adjust noise threshold and duration. Qolsys added this feature with MDU settings where noise complaints are a concern. The feature can be used in-place of the panel's built-in glass break sensor. Alarm.com is planning to add back-end support for this feature sometime in the future.

Alarm.com commercial customers will be able to take advantage of their Smarter Business Temperature Monitoring (SBTM) service plan, which is used in conjunction with the DSC PG9905 PowerG Temperature Sensor. The SBTM service plan allows for 24/7 monitoring, real-time alerts, and historical temperature reporting. It is designed with businesses like restaurants, grocery stores, and pharmacies in mind. Alarm Grid customers with Alarm.com commercial accounts can contact us for more information. In addition, the IQ2+ can now display a trouble condition when an external probe is disconnected from the DSC PG9905.


If you use Alarm.com for solar energy monitoring, then you will be pleased to know that IQ Panel 2 Firmware Version 2.5.3 offers the ability to provide information from your solar inverter right on your security panel! Solar inverter units from SolarEdge and Enphase are supported. Please see this prior blog post for more info about Alarm.com Solar Monitoring.

Thinking ahead, Qolsys has made Firmware Version 2.5.3 compatible with future Z-Wave 700-Series daughter cards. The 700-Series of Z-Wave will represent the successor to Z-Wave Plus, also known as the Z-Wave 500-Series. Like all new iterations of Z-Wave technology, the 700-Series will allow for extended range and battery life when used with a compatible Z-Wave controller or hub. We hope to see 700-Series Z-Wave devices enter the market sometime in the not-so-distant future. Qolsys also made improvements to the IQ2 Z-Wave Diagnostics Map when using the Z-Wave 6.81 SDK to include RSSI values, as well as the ability to move automation device on the Diagnostics Map.

Some new 500-Series Z-Wave Plus devices are now supported by the IQ Panel 2. Most notably, these include Z-Wave switches from Eaton. Newly supported models include the RF9601, RF9617, RF9640-N, and RF9642-Z. It's good to see Qolsys increasing their support of compatible Z-Wave devices, and we have heard particularly nice things about the Z-Wave switches from Eaton and Cooper.

You can now disarm from the main IQ Panel 2 during the Exit Delay if the arming session was initiated from an IQ Remote, PowerG Keypad, or key fob device. Qolsys also added three (3) new Sensor Groups for keypads, key fobs, and panic switches. These new Sensor Groups include (3) Mobile Silent, (5) Fixed Silent Auxiliary, and (7) Mobile Silent Auxiliary. These new Sensor Group options should add some more versatility for these devices. And as for the Qolsys IQ Remote Keypad, it now has the ability to pair with IP routers using the Protected Management Frame (PMF) protocol.

Qolsys iq remote ag iq panel 2 remote touchscreen keypad

There are some new changes to the Easy Install Wizard that loads upon booting up the system for the first time. A new drop-down option will allow you to select one of (13) languages for the setup wizard. There is also a new page in the wizard with QR links for you to scan using the camera on your Android or iOS phone to quickly download the Alarm.com Mobile App. Also added to the Easy Install Wizard are new help screens that provide more information on how to pair and test door and window contacts and motion detection sensors.

Some general improvements to the system's PowerG firmware have also been bundled with Firmware Update 2.5.3. The PowerG Modem Firmware is now Version 2.38. There is now support for Fire Trouble and Dirty Detector Trouble on the IQ2 and ADC when DSC PG9936 PowerG Smoke Detectors are used. Proximity tag support is now supported with the Visonic PowerG Wireless Keypads (models KP141 and KP241). And the Alarm.com back end can now show the "Not Networked" status for PowerG Sensors in the Event History. This occurs when a PowerG device is enrolled with the panel, but then fails to complete the network association and goes into RF sensor failure.

There are also some changes affecting certain PowerG Door and Window Contact Sensors. For the DSC PG9309 and DSC PG9312, both the reed switch and the auxiliary input can be disabled during disarm. The same also applies to the auxiliary input on the DSC PG9945. The purpose of this is to extend the battery life on high traffic doors. Additionally, the PG9945 and PG9309 can be learned-in with the IQ2+ twice. One zone will be for the sensor's internal reed switch, which the other will be used with the auxiliary input.

Dsc pg9945 powerg 915mhz wireless door slash window contact


Other miscellaneous features have been added as well. LiveAnswer is now supported on the IQ2 for security cameras with non-standard aspect ratio streaming. New languages of German, Danish, Portuguese, Hungarian, and Romanian have all been added to the IQ Panel 2. The IQ2 will also now provide audible and visual indication of dual-path failures when the EN Grade 2 Setting is enabled. A change to the Swinger Shutdown feature has been made so that once a sensor reaches its Swinger Shutdown limit, a subsequent sensor event will tell the IQ2 to send an event notice to Alarm.com. Lastly, various improvements to the system have been made so that the IQ2 meets the EN50131-1 Standard.

Now that we have covered all of the new features included with Firmware Version 2.5.3, we can cover the process for upgrading your IQ Panel 2. Qolsys did things a little bit different this time. In order to download 2.5.3, your IQ Panel 2 or IQ Panel 2 Plus must be running a firmware version between 2.0.1 and 2.4.2. Do not attempt to download 2.5.3 if your IQ Panel 2 is running Firmware Version 2.5.0 or 2.5.1. If your IQ2 is on one of those firmware versions, then you must upgrade in stages by upgrading to Firmware Version 2.5.2 first, and then upgrading to Version 2.5.3. More information on upgrading to 2.5.2 can be found here.

If you need to check the firmware version for your panel, click the small grey bar at the top of the screen, and choose Settings > Advanced Settings > enter Installer Code (default 1111) > About > Software. You should see the firmware version displayed. The panel in the picture below is already on 2.5.3.


Once your IQ2 is on a firmware version of 2.0.1 to 2.4.2, or is on Firmware Version 2.5.2, then you can begin upgrading the Qolsys IQ Panel 2 Firmware Version 2.5.3. To begin, make sure your panel is monitored and connected with the Alarm.com servers via WIFI. The panel should be plugged into its AC outlet, and it should not have a low-battery condition.

When ready, you can perform the update by clicking the small grey bar at the top of the screen and selecting Settings > Advanced Settings > Installer Code (default 1111) > Upgrade Software > Patch Tag > enter iqpanel2.5.3 > OK > Upgrade Using Network. Then press OK when prompted. It will take about five (5) minutes for the update process to complete. The panel will reboot as part of the update process.

If you have any questions about the Qolsys IQ Panel 2 Plus, please reach out to us. Also remember to check out this post to learn more about our monitoring plans for gaining access to Alarm.com. The best way to contact us with questions about the IQ Panel 2 System or alarm monitoring in general is to email support@alarmgrid.com. We check our email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , ,

Comments


Posted By

It's time for another video recap! There are eight (8) new videos this week, all featuring yours truly. We spent a lot of time working on the 2GIG GC2e again. We also covered the process for backdooring the Honeywell LYNX Touch Panels, and we touched on the IQ2+. Let's check out the videos!

Alarm grid inside security stickers

Pairing a Z-Wave Device with the 2GIG GC2e

I show you how to pair a Z-Wave device with a 2GIG GC2e Security System. The 2GIG GC2e serves as a Z-Wave Plus controller, which allows you to pair smart home automation devices with the system. Devices can be controlled locally at the panel, as well as remotely from Alarm.com if the system is monitored. There are many types of Z-Wave devices you can use with the GC2e, including lights, door locks, smart thermostats, and more!


Programming a Wireless Zone On a 2GIG GC2e

I show you how to program a wireless zone for a 2GIG GC2e Alarm System. Every sensor used with the 2GIG GC2e will take up at least one zone. The GC2e System has sixty (60) wireless zones available. You can pair sensors from the Honeywell 5800 Series, the 2GIG 345 MHz Series, and the 2GIG eSeries Lineup. We recommend auto-enrolling any new sensor to prevent entering an incorrect Serial Number. Auto-enrolling will also confirm successful communication.


Programming a Key Fob for a 2GIG GC2e

I show you how to program a key fob for a 2GIG GC2e Alarm Panel. A key fob is a small, handheld device that you can use to arm and disarm your system. You can very easily carry around a key fob in your pocket or purse, and they are great for putting on key rings. Popular key fob options for the 2GIG GC2e System include the 2GIG KEY2-345, the 2GIG KEY2e-345, and the Honeywell 5834-4.


Adding & Changing User Codes On a 2GIG GC2e

I show you how to add and change user codes on a 2GIG GC3 Security Panel. The GC2e has (64) user code slots available. You need a valid user code to successfully disarm the system. It is recommended that everyone who uses the system regularly has their own user code so that you can keep track of who uses the system. You can also apply a schedule to a code so that it only works at certain times.


Using the Backdoor to Enter Programming On a Honeywell L5200 or L5210

I show you how to use the backdoor method on a Honeywell L5200 or L5210. The backdoor method involves rebooting the panel and then performing a special sequence of commands as the system reloads. By completing this process, you can get into programming if you were previously locked out. Please note that the backdooring process will not work if the system is currently in an armed state. You will need to disarm the system before you can backdoor.


Getting Back Into Programming On an L7000 If You're Locked Out

I show you how to get into programming on a Honeywell L7000 if you're locked out by using the backdoor method. There are two (2) main reasons why you would become locked out of programming. The first is that the option "NO" was selected at the prompt asking if the installer should be allowed to re-enter programming. Always choose "YES" when exiting programming. The other possibility is that you do not know the Installer Code for the system. Do not change the Installer Code from its default of 4112 to avoid being locked out.


Secure Arming On the Qolsys IQ Panel 2 Plus

I demonstrate the Secure Arming feature on the Qolsys IQ Panel 2 Plus. When Secure Arming is enabled, you must enter a valid user code or the Master Code when arming the system. Normally, the system can be armed without providing a code. Additionally, you must also provide a code if you go to cancel an arming session during the Exit Delay countdown if this feature is enabled. Many parents with small children enable the feature to prevent the system from being armed accidentally.


IQ Panel 2 Exit Delay Increased After Opening Door

I explain why the Exit Delay timer on the Qolsys IQ Panel 2 Plus will automatically increase after opening a door. This is due to a false alarm prevention feature called Auto Exit Time Extension. This feature is activated if two (2) Entry/Exit faults are detected during the Exit Delay countdown. When you fault the first E/E Zone after arming, the system assumes that you have left the building. Then when another E/E fault is detected, the system assumes that you have returned. It then gives you an added 60 seconds to exit the building. If you quickly re-entered the premises because you forgot something, this prevents you from having to disarm and then re-arm the system.

Tags: , , , , , , , , , , , , , , , , ,

Comments


Posted By

One of the biggest benefits of alarm monitoring service is that most plans include access to an interactive monitoring and automation platform for controlling your system and smart home automation devices remotely. This is extremely convenient, and it can offer you great peace of mind!

2gig gc3e verizon lte 10 1 kit wireless encrypted alarm system 1

Most Alarm Grid monitoring plans will include access to either Total Connect 2.0 (TC2) or Alarm.com (ADC). TC2 is for Honeywell and Resideo Alarm Systems, while ADC is for systems from other manufacturers, such as Qolsys, 2GIG, and DSC. For TC2, your system can use an internet communicator, a cellular communicator, or dual-path communication with both internet and cellular. But a panel using ADC must have a cellular communicator that is activated and registered. IP (internet protocol) connectivity is optional for Alarm.com.

Before buying a system and/or communicator, you should consider which monitoring plan is right for you. In order to control your automation devices through an interactive platform, you must have monitoring plan of Silver or higher. Keep in mind that anyone using Alarm.com will have a Gold Plan or higher, as Gold is needed for cellular connectivity. You can choose between central station plans for automatic emergency dispatch, and self plans where it is up to the end user to request help. This guide will tell you all about our monitoring plans.

The real fun begins once you have the right system, communicator, and monitoring plan. By accessing Total Connect 2.0 or Alarm.com, you can control your system remotely by using a convenient app on your phone, or by opening a web browser. It is also possible to check the status of your system or an automation device, which is great if you forgetful and forgot whether or not you took proper action before leaving home. Some of the situations where this may be convenient can include:

  • Making sure you armed your system before leaving.
  • Turning ON your front porch lights if you're arriving home late.
  • Checking to see that you locked your front door before heading out.
  • Turning OFF your thermostat to save money while you're away.
  • Making sure your garage door is closed if you forgot.

Alarm Grid offers many smart home automation devices that allow for easy integration with a security system. Most notable are Z-Wave devices. The great thing about Z-Wave is that the smart home protocol integrates very nicely with most of the security systems we support. It is super easy to build a robust and reliable Z-Wave network of interconnected devices. Most of the new wireless systems we sell will readily support Z-Wave devices right out of the box.

We understand that this can be a lot to wrap your head around all at once. That is why we're here to help! We invite you to contact us so that we can help you plan the ideal alarm system and automation network for your home. The best way to reach us is to either email our team at support@alarmgrid.com, or call us at (888) 818-7728 during our regular business hours of 9am to 8pm ET M-F. Our planning team will be happy to help you every step of the way in building your new state-of-the-art system. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

We're here with another video recap! There are eight (8) new videos for you to check out this week. Once again, I took the role of appearing in all the videos. We hope to have some familiar faces returning soon! But for now, let's take a look at what our video team has been up to.

Alarm grid inside security stickers

Deleting a Wireless Zone from a Simon XT

I show you how to delete a wireless zone from a Simon XT Security System. The Simon XT uses 319.5 MHz wireless sensors, and it has forty (40) zone slots available. By accessing the Sensors Menu of Programming, you can delete any wireless zone that has been set up with the system. You can then enroll a new sensor in that open zone slot if needed. Keep in mind that the zone must be rebuilt from scratch if you decide to re-add the sensor back to the system.


Deleting a Wireless Zone from a Simon XTi or Simon XTi-5

I show you how to delete a wireless zone from a Simon XTi or Simon XTi-5. The Simon XTi and Simon XTi-5 are essentially the same as the Simon XT, except for the fact that these two panels have built-in touchscreen keypad. Both the Simon XTi and Simon XTi-5 have forty (40) available wireless zones, and they both use 319.5 MHz wireless sensors. If you delete a zone from the Simon XTi or Simon XTi-5, then you can reuse the zone with a new sensor.


Disabling Exit Sounds on a Qolsys IQ Panel 2 or IQ Panel 2 Plus

I show you how to disable Exit Delay sounds on the Qolsys IQ Panel 2 Plus. The IQ2 makes Exit Delay sounds for false alarm prevention. The idea is that if you accidentally Arm Away the system, then the Exit Delay sounds will alert you to the situation so that you know to either leave the building or cancel the arming session. But if you find Exit Delay sounds to be bothersome or annoying, there are a couple of different options for muting these sounds.


Cover Tamper Causes the Qolsys IQ Panel 2 to Make Strange Noises

I explain why the Qolsys IQ Panel 2 will make an usual noise every thirty (30) minutes. The reason why this happens is because the panel is not positioned on its back mounting plate properly. It can be a bit tricky to get the panel on the back plate properly, but once you do, the sound should stop occurring. If you absolutely cannot get the panel positioned on the back plate, then you do have the option of disabling tamper cover notifications in programming.


Manually Extending the Exit Delay Time On IQ2

I show you how to manually extend the Exit Delay countdown time on the Qolsys IQ Panel 2 for a single arming session. When you Arm Away on the IQ2, the Exit Delay timer will go into effect. You must then leave the building or cancel the arming session within the exit delay time limit. If you press the green +60 button, then the Exit Delay will be extended by sixty (60) seconds. You can only do this once per arming session. Pressing the button again will do nothing.


Permanently Extending the Exit Delay Time On IQ2

I show you how to permanently extend the Exit Delay countdown time on the Qolsys IQ Panel 2. By permanently extending the Exit Delay, you will have a longer amount of time to vacate the building every time you Arm. The system will use either the Normal Exit Delay setting or the Long Exit Delay setting depending on what zones you have programmed with the system. If you have at least one zone with Sensor Group 12 - Entry/Exit Long Delay, then the system will use the Long Exit Delay setting.


Installing a Honeywell 7847i on a VISTA P-Series Alarm Panel

I show you how to install a Honeywell 7847i on a VISTA P-Series Security System. The Honeywell 7847i is an IP communicator that allows a compatible panel to connect with the Resideo AlarmNet Servers for monitoring service. If you want to use Total Connect 2.0 with your system, then you must be running Firmware Version 9.12 or higher on a VISTA-15P or VISTA-20P. You can determine the firmware by checking the PROM Chip. No version of the VISTA-10P will work with Total Connect 2.0.


Installing a Honeywell 7847i On a VISTA TURBO Panel

I show you how to install a Honeywell 7847i on a Honeywell VISTA TURBO Panel, such as a Honeywell VISTA-128BPT or a Honeywell VISTA-250BPT. The most common reason why someone will choose to use an IP-only communicator is because they want monitoring costs to be as low as possible. IP monitoring is less expensive than cellular monitoring because no cellular service fees are incurred. But keep in mind that an internet outage will take your panel offline if you rely strictly on IP communication for your system.

Tags: , , , , , , , , , , , , ,

Comments


Posted By

Alarm Grid has learned that Johnson Controls has acquired the remaining stake of Qolsys. Johnson Controls now fully owns Qolsys. The press release from Qolsys states that all key Qolsys leaders and founders will remain at the company's Silicon Valley headquarters in San Jose, CA.

Qolsys iq panel 2 plus verizon lte with powerg s line and legacy

Jeff Williams, President of Global Products for Johnson Controls said of the acquisition:

"Qolsys has grown from a startup to a leading security platform provider with over 4,000 dealers and service providers worldwide. Johnson Controls sees long-term opportunities to bring Silicon Valley innovation and culture to our broader cloud-enabled IoT solutions in building management, fire and HVAC businesses... The opportunity to acquire Qolsys allows Johnson Controls to achieve operational efficiencies and scale across our global markets."

Johnson Controls had already owned the majority of Qolsys. This latest acquisition now puts the entire company under the ownership of Johnson Controls. In addition to Qolsys, the Johnson Controls banner also includes the likes of DSC, Bentel, Visonic, PowerG, and Tyco. The company has certainly assembled an extensive collection of security products and namesakes. Now with Qolsys fully under their control, their expansion should only continue.

As part of the move, Qolsys CEO Dave Pulling will transition to the role of Vice President and General Manager of Global Intrusion Products for Johnson Controls. According to Pulling, Johnson Controls will remain committed to serving existing Qolsys users, while also setting their sights on potential global growth. As for the Qolsys namesake, it shouldn't be going anywhere, and it will continue to represent various panels, sensors, and accessories.

Interestingly, the bottom of the press release from Qolsys hints at a "fourth generation IQ Panel", with a very vague release date of 2021. The press release states that the Fourth Gen IQ Panel will feature a "Qualcomm Chipset with support for AI, M2M, and Next Generation Connectivity". This is the first we've heard about a 4th-gen IQ Panel, but it really sounds like exciting news. We don't have any other details about a 4th-gen Qolsys IQ Panel at this time, but we will definitely keep our eyes open for more news.

Qolsys is currently known for their state-of-the-art IQ Panel 2 Plus. The company is set to release the lower-cost Qolsys IQ Hub later this year, which will represent the "third gen" in the IQ Panel lineup. Also on the roadmap for Qolsys is the upcoming Qolsys IQ Router. And last month's release of the DSC PowerG Wired to Wireless Converter was big news for many Qolsys IQ Panel 2 Plus users. It goes without saying that the company has been frequently making some big waves in the security industry.

Alarm Grid has frequently praised Qolsys Panels for their intuitive designs and simple user interfaces (UIs). We have found that the IQ Panel 2 serves as a great option for new users who aren't necessarily accustomed to, or experienced in, operating alarm systems. We hope that this will continue for Qolsys, even as they are now operating fully under the Johnson Controls banner. Many end users appreciate having easy-to-operate security systems greet them in their homes and businesses. Our hope is that Johnson Controls and Qolsys do not lose sight of that vision.

If you have any questions about the Qolsys IQ Panel 2 Plus, or any other security product from Johnson Controls, or if you want to learn more about monitoring service, please send an email to our team at support@alarmgrid.com. We check our email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , ,

Comments


Posted By

We have learned that Qolsys has released a fix for the 6.81.03 Z-Wave Firmware for the IQ Panel 2 and IQ Panel 2 Plus. With this fix, the 6.81.03 Z-Wave Firmware is once again available for download for any Qolsys IQ Panel 2 or IQ Panel 2 Plus running System Firmware Version 2.4.2 or higher.

Qolsys iq panel 2 plus verizon lte with powerg s line and legacy

The saga regarding Z-Wave Firmware 6.81.03 for the IQ Panel 2 has been ongoing for quite awhile now. For anyone who isn't fully in the loop, we will provide a brief recap of the events.

In September of last year, Qolsys released IQ Panel 2 Firmware Version 2.4.0. Any newly manufactured IQ Panel 2 Plus System with 2.4.0 or higher pre-installed would have the 6.81.03 Z-Wave Firmware already pre-installed out of the box. Those with an older IQ Panel 2 or IQ Panel 2 Plus System that had been upgraded from a lower system firmware version would need to separately update the Z-Wave firmware for the system if they wanted to use the associated features.

To be clear, updating the Z-Wave firmware on an IQ Panel 2 or IQ Panel 2 Plus is optional. The 6.81.03 Z-Wave Firmware only provides the Smart Start feature for enrolling compatible devices via a scanned QR code, and it upgrades the panel's automation security protocol from S0 to S2. If a user doesn't need and/or doesn't care about these features, then skipping the update is fine. Unlike panel firmware for the IQ2, the system's Z-Wave firmware isn't as important to have on the latest version. Many users chose to skip the update entirely. And that remains the case now. If you do not want the update, then you do not need to apply it.

Later, in July 2020, Qolsys discovered problems with Z-Wave Firmware Version 6.81.03. Once this happened, Qolsys took the associated patch tag off the network so that it could no longer be downloaded. But now that Qolsys has corrected the associated issues, the update is once again available for download. Anyone who performs the upgrade now will download an updated version of the 6.81.03 Z-Wave Firmware to the panel. This updated version does not have the problems and issues that were associated with the earlier version, even though they are both referred to as Z-Wave Firmware 6.81.03.

Of course, there are some users who still have the faulty version of the 6.81.03 Z-Wave Firmware on their panels. For these users, the problem can be corrected by performing a system firmware update for the IQ Panel 2. In other words, upgrading to the latest system firmware (2.5.2) with the 6.81.03 Z-Wave Firmware already installed will update the panel's Z-Wave firmware from the faulty version of 6.81.03 to the newly updated version that has the fixes applied. Users who were already running 2.5.2 at the time they applied the faulty Z-Wave firmware patch, will need to wait for the next firmware release to fix the problem. According to Qolsys, their IQ Panel 2 System Firmware Version 2.5.3 will be made available later this month. More information on IQ Panel 2 System Firmware can be found on this helpful page.

We understand that this may be a bit confusing, so we have broken IQ Panel 2 and IQ Panel 2 Plus users into three (3) categories. Find the bold statement below that applies to you, and follow the corresponding instructions. It may also be helpful to check and see whether or not your IQ Panel 2 is on Z-Wave Firmware 6.81.03. To do this, press the small grey bar at the top of the main screen, and choose Settings > Advanced Settings > enter Installer Code (default 1111) > About > Z-Wave. You should see the current Z-Wave Firmware listed.

1. My IQ Panel 2 is NOT on Z-Wave Firmware 6.81.03.

If your IQ Panel 2 is not on Z-Wave Firmware Version 6.81.03, then that tells us two things. For one, it means that the panel was originally manufactured with a system firmware version of less than 2.4.0. Second, it also means that no updates to the system's Z-Wave firmware have ever been applied.

Since you haven't updated the Z-Wave firmware for the system before, you can apply the update as normal. You will be downloading the newly updated 6.81.03 that has the proper fixes applied. Please see this helpful FAQ for more information about applying the patch tag.

Remember, your IQ Panel 2 must be on at least System Firmware Version 2.4.2 to apply the 6.81.03 Z-Wave Firmware. If your system is not on a high enough firmware, then now is a great time to update to the latest system firmware version, which is Version 2.5.2. Alternatively, you might choose to wait a few weeks for System Firmware Version 2.5.3, since it's coming so soon.

Another option is to just skip the Z-Wave update entirely. The older "pre-6.81.03" Z-Wave firmware versions are very stable, and they generally work great. All you are getting by updating the Z-Wave firmware is access to the Smart Start feature and an upgrade for your system's Z-Wave Security Protocol (from S0 to S2). If you do not care about these updates, then you can simply take no action.

2. My IQ Panel 2 is on Z-Wave Firmware 6.81.03, but I'm not on the latest System Firmware 2.5.2.

Your panel is on Z-Wave Firmware Version 6.81.03 either because it was manufactured that way, or because a Z-Wave firmware update was manually performed. In either case, the 6.81.03 Z-Wave Firmware Version your system is running is flawed, and we strongly advise applying a fix. There is no way to "downgrade" to an older Z-Wave firmware, so you must apply the newly fixed 6.81.03 Z-Wave Firmware to the panel.

Luckily, Qolsys made it very easy to fix the issue for users in this situation. All you need to do is update the system firmware to the latest version. By updating to System Firmware 2.5.2 with the 6.81.03 Z-Wave Firmware already installed, the appropriate fix will be applied so that your system's Z-Wave firmware will work in the proper manner. We recommend checking our IQ Panel 2 Plus System Firmware Updates Page for more information.

3. My IQ Panel 2 is on Z-Wave Firmware 6.81.03, AND I'm already on System Firmware 2.5.2.

Since your system is already on the latest firmware, you cannot perform a firmware update to fix the issue. Any user in this situation will not be able to take any action towards fixing their faulty Z-Wave firmware until Qolsys releases IQ Panel 2 System Firmware Version 2.5.3. Once 2.5.3 is available, you can download that Z-Wave firmware, and the updated 6.81.03 Z-Wave Firmware will also be automatically applied at that time. Qolsys says that System Firmware 2.5.3 will be made available later this month. Alarm Grid will post an update blog once 2.5.3 is available, so make sure to stay tuned.

UPDATE: Qolsys IQ Panel 2 Plus Firmware Version 2.5.3 is now available! Please see this blog post for more information.

We understand that this is a lot of information to take in for a relatively simple issue. If you need any clarification regarding the issue, or if you want to learn more about our monitoring services, please email us at support@alarmgrid.com. We check our email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , ,

Comments