Honeywell 5816MN Posts

Posted By

A great way to build out your Honeywell Lyric is with Honeywell 5800 Sensors. These are simple, 345 MHz wireless sensors that you can easily enroll with the system for security, life-safety, and environmental monitoring. They are perfect for expanding your system and making it more robust.

Honeywell lyric controller encrypted wireless security system

When you want to pair a Honeywell 5800 Sensor with the Lyric, the process is very straightforward. Put the Lyric in its auto-enrollment mode by choosing Security > Tools > enter Installer Code (default 4112) > Program > Zones > Add New > Serial Number. Make sure the RF Type on the right-hand side is set to 5800. Then activate the sensor either by faulting it or triggering its cover tamper switch. The Lyric should beep to confirm that it received a signal transmission. Then activate the sensor a second time to have the Lyric display the Serial Number. The third activation will confirm the Serial Number and return you to the screen where you can configure the zone settings.


Programming the zone settings for the sensor is actually quite simple. Depending on how you enrolled the sensor, you may need to adjust the Loop Number. This is almost always the case if you enrolled the sensor by activating its tamper switch. Refer to the instruction manual for the 5800 Sensor to determine which Loop Number to use.

The two (2) Zone Descriptors and the Device Type serve as the name for the sensor. You should choose a name that will help you identify the sensor, e.g. "Front Bedroom Motion Sensor", "South Hallway Door", etc. The Response Type determines how the system responds when the sensor is faulted. See our list of Lyric Response Types for more info.

Alarm Report should be set to Yes if you want the system to report out through AlarmNet to a Central Station if the zone causes an alarm on the system. That is an essential component of alarm monitoring services. Chime is optional, and it has the panel emit any one of several available sounds when the zone is faulted. Supervision tells the panel to look for an RF check-in signal from the sensor periodically to ensure that it is online. Click Save in the bottom-right after you finish adjusting the settings.


Keep in mind that only uni-directional (one-way) sensors from the Honeywell 5800 Series can be used with the Lyric. This leaves out bi-directional devices like the Honeywell 5800WAVE Siren, the Honeywell 5828 Keypad, and the Honeywell 5800RL Relay Module, so make sure you do not buy those for the Lyric. But you still have a lot of excellent sensors and security devices to choose from.

Below is a list of the Honeywell 5800 Sensors that you can use with the Honeywell Lyric:

Sensor Name
Notes
Honeywell 5800MINI
Honeywell 5800mini interior wireless door and window sensor
Door/Window sensor. Uses Loop 1.
Honeywell 5800PIR-RES
Honeywell 5800pir res wireless pet immune motion detector close up
PIR motion sensor. Uses Loop 1.
Coverage Area: 35' x 40'
Honeywell 5816
Honeywell 5816 wireless door window sensor
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5811
Honeywell 5811 wireless wafer thin door and window sensor
Door and window sensor. Uses Loop 1.
Honeywell 5800C2W
Honeywell 5800c2w hardwire to wireless system 9 zone conversion module
9-zone wired to wireless converter. Allows hardwired sensors to communicate with the Lyric as wireless devices. All zones use Loop 1 and a unique Serial Number ID.
Honeywell 5800CO
Honeywell 5800co wireless carbon monoxide detector
Carbon monoxide sensor.
Loop 1 = CO Detection
Loop 2 = End of Sensor Life (separate programming only required on TURBO and other V-Plex panels)
Honeywell 5800COMBO
Honeywell 5800combo smoke heat and co detector
Combination, smoke, heat, CO, and low-temperature sensor. Uses up to five (5) zones on the Lyric Panel. Has two (2) Serial Numbers for enrollment purposes.
Loop 1, SN 1 = Smoke/Heat Detection
Loop 2, SN 1 = Smoke/Heat Maintenance
Loop 3, SN 1 = Low Temperature Detection
Loop 1, SN 2 = CO Detection
Loop 2, SN 2 = End of Sensor Life (separate programming required only on TURBO and other V-Plex panels)
Honeywell 5800FLOOD
Honeywell 5800flood wireless flood and temperature sensor
Flood and temperature sensor.
Loop 1 = Low Temperature Detection
Loop 2 = High Temperature Detection
Loop 3 = Flood Detection
Honeywell 5800MICRA
Honeywell 5800micra wireless recessed window contact
Recessed window sensor. Uses Loop 1.
Honeywell 5800PIR
Honeywell 5800pir exterior of wireless motion detector
PIR motion sensor.
Loop 1 = Low Sensitivity Motion.
Loop 2 = High Sensitivity Motion.
Loop 3 = Low Temperature Detection
Coverage Area: 35' x 40'
Honeywell 5800PIR-COM
Honeywell 5800pir com exterior of wireless long range motion det
Commercial PIR motion sensor.
Loop 1 = Low Sensitivity Motion
Loop 2 = High Sensitivity Motion
Loop 3 = Low Temperature Detection
Coverage Area: 60' x 80'
Honeywell 5800PIR-OD
Honeywell 5800pir od wireless outdoor motion detector exterior
Outdoor PIR motion sensor. Uses Loop 1.
Honeywell 5800PIR-OD2
Outdoor PIR motion sensor. Uses Loop 1.
Honeywell 5800RP
Honeywell 5800rp wireless repeater
Wireless repeater for Honeywell 5800 Sensors. Does not require enrollment, but can be assigned a single zone for RF supervision, low-battery, AC loss, and RF jam detection. This is done using Serial Number 1 with Loop 1, with DIP Switch 2 set in the OFF position. Can also use up to four (4) separate zones for supervision when DIP Switch 2 is set to ON. This is required for UL installations.
Honeywell 5800RPS
Honeywell 5800rps wireless recessed door and window plunger sens
Recessed door/window sensor. Uses Loop 1.
Honeywell 5800SS1
Honeywell 5800ss1 exterior of wireless shock sensor
Shock sensor. Uses Loop 1.
Honeywell 5802MN
Honeywell 5802 wireless panic button
Medical alert button. Uses Loop 1.
Honeywell 5802MN2
Honeywell 5802mn2 wireless dual button medical alert
Medical alert button. Uses Loop 1.
Honeywell 5802WXT
Honeywell 5802wxt wireless panic button
Panic button. Uses Loop 1.
Honeywell 5802WXT-2
Honeywell 5802wxt 2 wireless dual button medical alert
Panic button. Uses Loop 1.
Honeywell 5806W3
Honeywell 5806w3 wireless smoke detector
Smoke detector. Uses Loop 1.
Honeywell 5808W3
Honeywell 5808w3 wireless smoke and heat detector
Smoke and heat detector.
Loop 1 = Smoke & Heat Detection
Loop 3 = Low Temperature Detection
Honeywell 5809
Honeywell 5809 wireless heat detector
Fixed temperature and rate-of-rise heat detector. Uses Loop 1. Alarm occurs when the temperature exceeds 135 degrees Fahrenheit, or when the temperature rises more than 15 degrees Fahrenheit per minute.
Honeywell 5809FXT
Honeywell 5809 wireless heat detector
Fixed temperature heat detector. Uses Loop 1. Alarm occurs when the temperature exceeds 135 degrees Fahrenheit.
Honeywell 5809SS
Honeywell 5809ss wireless fixed temperature slash ror heat detec
Fixed temperature and rate-of-rise heat detector. Uses Loop 1. Alarm occurs at 135 degrees Fahrenheit or when the temperature rises more than 15 degrees Fahrenheit per minute.
Honeywell 5814
Honeywell 5814 wireless small door sensor and window sensor
Door and window sensor. Uses Loop 1.
Honeywell 5815
Honeywell 5815 white wireless aesthetic door sensor and window s
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5816MN
Honeywell 5816mn wireless mini door sensor and window sensor
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switches
Honeywell 5816OD
Honeywell 5816od wireless outdoor door and window sensor top
Outdoor door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5817
Honeywell 5817 wireless three zone sensor
Three (3) zone door and window sensor & transmitter.
Loop 1 = NC or NO (DIP Switch Selectable) unsupervised. It does not use an End of Line Resistor (EOLR)
Loop 2, 3 = NC Only. Both are unsupervised with no EOLR used
Honeywell 5817CBXT
Honeywell 5817cb wireless commercial sensor
Three (3) zone commercial transmitter.
Loop 1 = Two (2) Terminals; Primary Loop supervised by 470k Ohm (yellow, purple, yellow, gold) EOLR. Resistor must ALWAYS be installed, even if Loop 1 is not programmed. If Loop 1 is used as a burglary zone, then Loop 4 must be programmed as a separate zone for Cover Tamper protection.
Loop 2 = NC Reed Switch
Loop 3 = Two (2) Terminals; NC Loop unsupervised, no EOLR required
Honeywell 5817XT
Honeywell 5817xt three zone universal transmitter
Three (3) zone door and window sensor & transmitter.
Loop 1 = NC or NO (DIP Switch Selectable) unsupervised with no EOLR required
Loop 2, 3 = Two (2) Terminal Blocks, NC Only
Honeywell 5818MNL
Honeywell 5818mnl wireless recessed door sensor and window senso
Recessed door and window sensor. Uses Loop 1. Not suitable for use in metal doors
Honeywell 5819
Honeywell 5819 wireless shock processor and sensor
Three (3) zone shock processor.
Loop 1 = NC for Inertia Style External Shock Sensor. This input provides a suitable fast loop response of from 1ms to 20ms, based on dip switch setting
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact, unsupervised with no EOLR required
Honeywell 5819S
Honeywell 5819s wireless shock sensor and transmitter
Shock sensor and contact sensor.
Loop 1 = Built-in Inertia Style Shock Sensor
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact
Honeywell 5819WHS
Honeywell 5819whs wireless transmitter with integrated shock sen
Three (3) zone shock processor.
Loop 1 = NC, Built-in Inertia Style Shock Sensor
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact
Honeywell 5820L
Honeywell 5820l super slim wireless door and window sensor
Slimline door and window sensor. Uses Loop 1.
Honeywell 5822T
Honeywell 5822t wireless garage tilt sensor
Garage tilt sensor.
Loop 1 = NC for Wired Contact, unsupervised, no EOLR used
Loop 3 = Tilt Switch
Honeywell 5834-2
Honeywell 5834 2 wireless 2 button security key fob
Two (2) button key fob. Dual-button inputs allowed. Uses three (3) loops total, for a possible three (3) inputs. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5834-4
Honeywell 5834 4 wireless 4 button security key fob for honeywell security systems
Four (4) button key fob. Dual-button inputs allowed. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5834-4EN
Honeywell 5834 4en wireless enhanced 4 button security key fob
Four (4) button key fob. Dual-button inputs allowed. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5853
Honeywell 5853 wireless glass break detector exterior
Glass break sensor. Uses Loop 1.
Honeywell 5869
Honeywell 5869 wireless commercial panic switch
Commercial panic switch. Uses Loop 1. Latches when tripped, key (provided) needed to reset it after it is tripped
Honeywell 5878
Honeywell 5878 wireless remote alarm keypad
Six (6) button key fob. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible.
Honeywell 5898
Honeywell 5898 wireless dual tec motion detector
Dual-tec motion sensor.
Loop 1 = Low Sensitivity Motion Sensor. Pet immunity is available for this loop. 50lb or 100lb pet immunity, selectable via DIP Switch 1
Loop 2 = High Sensitivity Motion Sensor.
Loop 3 = Temperature Sensor (High or Low, DIP Switch Selectable)
Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

Honeywell is known for producing some outstanding security equipment, and their wireless door and window contacts are no exception. With wireless contacts available from both the 5800 Series lineup and the SiX Series lineup, there are certainly some great options. But with all the possibilities, it might seem overwhelming if you are just getting started. This guide will help you choose the perfect wireless Honeywell door and window contact for your needs.

Honeywell 5820l super slim wireless door and window sensorFirst, a user should understand exactly how a door and window contact works. Almost every wireless Honeywell door and window contact functions using the exact same principles. These devices consist of a sensor and magnet. The sensor is the "brains" of the operation, and it is responsible for sending signals to the alarm system. It is typically installed on or inside the door or window frame. The magnet is installed on or inside the door or window itself. The only wireless Honeywell contact that does not use a magnet is the Honeywell 5800RPS. This is a wireless recessed sensor for doors only that operates using a plunger switch.

For proper operation, the device's magnet should be installed very close to the sensor. We usually recommend placing it within a half-inch of the sensor. However, some 5800 Series contacts, like the 5816OD, can function properly with a slightly larger spacing gap. When the door or window is opened, the magnet will separate from the sensor. This will cause a reed switch inside the sensor to activate. When this happens, the sensor will send a signal to the alarm system so that the programmed Response Type can be performed.

It's also important to know the system compatibilities for the different Honeywell wireless contacts. Their wireless contacts come from two different sensor lineups. These are the 5800 Series and the SiX Series. The 5800 Series contacts are unidirectional devices that operate at 345 MHz. This makes them compatible with any Honeywell System or 2GIG System. But the SiX Series contacts are bi-directional, fully encrypted sensors that communicate using 2.4 GHz WIFI. These sensors only work with Honeywell Lyric Systems.

Honeywell lyric controller encrypted wireless security system

If you have a Honeywell Lyric Controller, then you can choose between any Honeywell wireless contact on the market. But if you have a LYNX Touch or a VISTA System with an added wireless receiver, then you are restricted to the 5800 Series contacts. Additionally, if you are using a 2GIG GC3 or a 2GIG GC2, then you can use either 2GIG Contacts or Honeywell 5800 Series contacts. Any alarm systems that do not accept the 345 MHz frequency are unable to use Honeywell contacts.

The only two contacts in the Honeywell SiX Series Lineup are the Honeywell SiXCT and the Honeywell SiXMINICT. These are both wireless, surface-mount sensors that work exclusively with Honeywell Lyric Systems. What makes these sensors special is that they feature 128-bit AES encryption. Whenever the sensor sends a command to the Lyric System, the system must then send a secure response back to the sensor. The command will only go through if this secure response is received. Many security experts refer to this as a "digital handshake", and it is excellent for preventing any hacking attempts or wireless attacks.

The SiXCT and the SiXMINICT do have a few slight differences. Most notably, the SiXMINICT is smaller and more compact than the SiXCT. The SiXCT measures at 3.13”L x 1.61”W x 1"D, while the SiXMINICT measures at 2.44”L x 1.25”W x .45”D. So users who want a smaller sensors should go with the SiXMINICT. But the benefit of the SiXCT is that it features a larger wireless range (~300 feet) than the SiXMINICT (~200 feet). However, only users with particularly large properties should have to worry about signal range. One thing that these sensors do share in common is that they can both be batch-enrolled with the Lyric Controller.

  • Honeywell SiXCT - The standard SiX Series contact. Features a 300 foot range and encryption. Will only work with Lyric Systems.
  • Honeywell SiXMINICT - The more compact SiX Series contact. Provides a 200 foot range and encryption. For Lyric Systems only.

Honeywell sixct wireless door slash window contact for lyric conHoneywell sixminict wireless door slash window contact for lyric

But the SiX Series contacts aren't for everyone. For one, they will only work with the Lyric Systems. There are also no recessed contacts in the SiX Series lineup. Users who don't have a Lyric Controller or want a recessed sensor should look to the Honeywell 5800 Series instead. This is an incredibly diverse sensor lineup that has an appropriate contact option for virtually any situation. Any Honeywell or 2GIG System will work with these sensors. This includes any Lyric Controller, L7000, L5210, VISTA P-Series, 2GIG GC3, 2GIG GC2 and more. Most 5800 Series contacts feature a 150-200 foot wireless range that can be effectively doubled with the use of a 5800RP Wireless Repeater.

Honeywell l7000 wireless home security system with 7 inch screenHoneywell 5800rp wireless repeater

When selecting a 5800 Series Sensor, a user will choose between a surface-mount contact and a recessed contact. With a surface-mount contact, the sensor and the magnet are mounted on the outer surface of the door or window and its frame. But with a recessed contact, the sensor and magnet are installed inside the door or window and its frame. Surface-mount sensors are very easy to install, since they only require screws or double-sided foam tape. But the sensor will be visible on the outside of the door. Recessed sensors are more difficult to install since holes will need to be drilled. However, some users will appreciate the fact that recessed sensors are hidden.

For users who go with a surface-mount sensor there are certainly some great options in the 5800 Series. One of our favorites is the 5800MINI. This is a reliable sensor that boasts an impressive 200 foot range, despite its small size of just 2.2"H x 1"W x 0.25"D. This is arguably the best surface-mount contact in the Honeywell 5800 Series.

  • Honeywell 5800MINI - A small and discreet surface-mount contact. Offers a 200 foot wireless range. Great for almost any application.

Honeywell 5800mini interior wireless door and window sensor

But there are other surface-mount options than just the 5800MIIN. The 5816 is the most popular sensor that Honeywell has ever offered. It features a larger size and roughly the same range as the 5800MINI. But unlike the 5800MINI, the 5816 can be used as a wireless transmitter for a normally closed hardwired device. Honeywell also offers the 5820L Slim Line for narrow installations and the 5816OD for outdoor use.

  • Honeywell 5816 - Honeywell's most popular sensor. Can also be used as a wireless transmitter for a single NC hardwired device.
  • Honeywell 5820L - A slim line door and window contact that is great for narrow applications. Features a 150-foot range.
  • Honeywell 5816OD - A surface-mount contact for outdoor installations. Excellent for monitoring fences, sheds and detached garages.

Honeywell 5816 wireless door window sensorHoneywell 5816od wireless outdoor door and window sensor top


Honeywell also offers some less popular 5800 Series contacts. These include the 5811 (discontinued), the 5814, the 5815 and the 5816MN (discontinued). While these sensors will work just fine, there isn't really any reason to choose them over another 5800 Series contact.

  • Honeywell 5811 - A small and discreet sensor that has since been discontinued. Replaced by the Honeywell 5800MINI.
  • Honeywell 5814 - Another compact sensor option. It is not as robust as the 5800MINI. Its wireless range is only about 100 feet.
  • Honeywell 5815 - An aesthetically pleasing surface-mount contact that has roughly the same functionality as the 5816.
  • Honeywell 5816MN - A discreet surface mount sensor that has been discontinued. Replaced by the Honeywell 5816MN.

Honeywell 5814 wireless small door sensor and window sensorHoneywell 5815 white wireless aesthetic door sensor and window s

There are also several great recessed contacts in the 5800 Series. The Honeywell 5818MNL is a relatively standard recessed contact that can be used with almost any door or window. It features a 200-foot range, and the installation only requires minor drilling. The Honeywell 5800Micra is a recessed contact for windows only. It is a very small sensor with an attached antenna for sending wireless signals. Finally there's the 5800RPS, which uses a plunger switch instead of a sensor and magnet. This sensor can only be used with doors. When the door is closed, the plunger switch will be pressed in. Once the door is opened, the plunger switch will come out and activate the sensor.

  • Honeywell 5818MNL - A standard recessed contact for doors and windows. It is easy to install, and it has a 200 foot range.
  • Honeywell 5800Micra - A small recessed contact for windows only. Its antenna must be adjusted carefully when installing.
  • Honeywell 5800RPS - A recessed sensor that uses a plunger switch instead of a magnet. For use with doors only.

Honeywell 5818mnl wireless recessed door sensor and window sensoHoneywell 5800micra wireless recessed window contact

Alarm Grid has previously discussed the batteries used with door sensors. We recommend checking out that blog post for more information on which batteries to use with a door and window sensor. If you ever need any additional help choosing a Honeywell door and window contact for your DIY wireless alarm system, please feel free to send an email to support@alarmgrid.com. You can also contact one of our technical specialists by calling 888-818-7728 from 9am to 8pm EST M-F.

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments