Video Recap Posts

Posted By

We're back again with another video recap! Our video team put up five (5) new videos this past week. Most of them feature yours truly, but Jarrett managed to make an appearance as well. We hope that you find them helpful for using your security system. Let's check out the new videos!

Interlinking Honeywell SiXCOMBO Devices

I explain how you can "interlink" Honeywell SiXCOMBO devices using the "One-Go-All-Go" feature. One-Go-All-Go means that when one SiXCOMBO device on the Honeywell Lyric System is triggered and activates its 85 dB sounder, all other SiXCOMBO devices on the Lyric that have the One-Go-All-Go feature enabled will also activate their own 85 dB sounders. Honeywell SiXSMOKE devices can also be included in the One-Go-All-Go network. Although One-Go-All-Go won't result in any increased volume, it will spread the sound out to multiple locations to ensure that building occupants are notified during emergencies.


Using the SiXCOMBO for Only Smoke or Only Heat Detection

I explain how you can use the Honeywell SiXCOMBO for only smoke detection or only heat detection. The Honeywell SiXCOMBO is a combination sensor that serves as a smoke detector, heat detector, and carbon monoxide detector, all in one convenient life-safety device. Each of the three (3) aforementioned functions is considered to be a different "service" for the SiXCOMBO. You can toggle each individual service ON or OFF as desired. Remember that each enabled service will require its own zone on the Lyric System. With this functionality, you can set up the SiXCOMBO for only smoke, or only heat.


Pairing a 2GIG SP1 with the 2GIG GC3e

Jarrett shows you how to pair the 2GIG SP1 Touchscreen Keypad with the 2GIG GC3e Security System. The 2GIG SP1 can be used for security functions like arming, disarming, and bypassing sensors, as well as automation functions like controlling programmed Z-Wave devices. Once the SP1 has been successfully paired, it will mimic the GC3e screen almost identically. Although the SP1 is assigned to a specific smart area partition, you can actually use it to control any system partition, as long as smart areas are enabled on the system (Question 69 in Panel Programming), and you have a valid code.


Solving S2 Protocol Issues with the Qolsys IQ Panel 2 Plus

I show you various things you should check to ensure that the S2 Security Protocol works properly on a Qolsys IQ Panel 2 Plus. The S2 Security Protocol is used with compatible Z-Wave Plus devices, and it provides stronger protection than the older S0 Security Protocol. Support for the S2 Protocol was introduced in Qolsys IQ Panel 2 Z-Wave Firmware Version 6.81.03. Additionally, it is advised that you upgrade the system firmware to at least 2.5.3, as that version provided various Z-Wave fixes for the system. You can upgrade the system firmware and the Z-Wave firmware in either order.


Updating the Honeywell Home Tuxedo Firmware

I explain how the Honeywell Home Tuxedo Keypad receives automatic firmware updates over-the-air (OTA) from the Resideo AlarmNet Servers. To have a firmware update pushed down successfully, you must have the Tuxedo connected to WIFI, and its Enable Remote Upgrade feature must be turned ON. You must also have the connected VISTA System in a state where updates can be sent down. Once these conditions are met and a new update is available, it will be sent to the Tuxedo so that it can be automatically applied. The Tuxedo will reboot about (15) seconds after the update is received.

Tags: , , , , , , ,

Comments


Posted By

It's time for another video recap, this time covering October 7th thru 9th. Jarrett and I managed to put together quite a few videos with the help of our video team. We hope that you find them helpful in setting up your security system. Let's check out the latest Alarm Grid videos!

Resetting the Honeywell Home Tuxedo Keypad

I show you how to reset the Honeywell Home Tuxedo Keypad for a Honeywell VISTA System. There are three (3) types of resets that can be performed on a Tuxedo. These include a Tuxedo Keypad Refresh Power Cycle, a Tuxedo Keypad Factory Default, and a Z-Wave Factory Default. Make sure that you choose the proper type of reset based on what goal you must accomplish. Then it's as simple as following the steps to complete the reset.


Adding an External Keypad to a Qolsys IQ Panel 2

Jarrett shows you how to add an external keypad to a Qolsys IQ Panel 2 Security System. The most popular keypad for the IQ Panel 2 is the Qolsys IQ Remote. This is a touchscreen keypad that essentially mimics the screen of the IQ Panel 2. The IQ Remote can be used nicely for security functions, such as arming, disarming, and bypassing sensors. It can also be used for controlling smart home automation devices that are programmed with the IQ2.


Adding and Deleting Zones Using the Tuxedo Keypad

I show you how you can use Console Mode on a Honeywell Home Tuxedo to add and delete zones for a Honeywell VISTA Alarm System. Console Mode will have the Tuxedo emulate an Alphanumeric Keypad, such as a Honeywell 6160. You can use Console Mode to access *56 zone programming and perform the same programming process that you would on a regular keypad. The Tuxedo Keypad will reboot once you exit programming to save the changes.


Find MAC & CRC for Tuxedo

I show you how to find the MAC and CRC codes for a Honeywell Home Tuxedo Keypad. The Tuxedo has MAC and CRC codes because it connects to the internet. The reason why the Tuxedo connects to the internet is to relay automation information to and from Total Connect 2.0. You will need to provide the MAC and CRC to your monitoring company when they go to set up the Tuxedo with the Total Connect 2.0 platform and the Resideo AlarmNet Servers.


Running Power to a Honeywell L7000

Jarrett shows you how to provide power to the Honeywell L7000 Security System. Like most wireless systems, the L7000 receives primary power from a plug-in transformer. You can use traditional 2-conductor wiring for this process. But many users find that it is easier to use a prepared cable, such as the Honeywell LT-Cable. By using an LT-Cable, you will not need to strip any wires, and all you will need is a screwdriver for connecting at the transformer and panel.


Running Power to a 2GIG GC3 or GC3e

Jarrett shows you how to provide power to a 2GIG GC3 or 2GIG GC3e Security System. As the GC3 and GC3e are wireless all-in-one panels, we recommend connecting the backup battery before the transformer when powering on the system. You must open up the panel to connect the backup battery. The transformer can connect to either the positive (+) and negative (-) power terminals on the terminal block or the barrel port on the back of the panel.

Tags: , , ,

Comments


Posted By

Alarm Grid is back with another video recap! We've got some great new videos to help you get the very most out of your security system. As always, we hope that you find the new videos to be informative and helpful. Let's check out the newest tutorial videos from the Alarm Grid team!

Install Honeywell LTE-XA or LTE-XV On VISTA-15P, VISTA-20P, VISTA-21iP

I show you how to add a Honeywell LTE-XA or Honeywell LTE-XV to a Honeywell VISTA P-Series Alarm Panel. The LTE-XA and LTE-XV are cellular communicators used by VISTA Alarm Panels to communicate with the AlarmNet servers. Adding a communicator to a VISTA System is necessary for getting it monitored and set up with the Total Connect 2.0 platform for controlling the system remotely. The communicator will use a 4-wire connection that is made at the panel's ECP bus.


Troubleshooting No Signal issue on Resideo LTE-XA or LTE-XV

In a follow up to the previous video, I show you the general troubleshooting steps to perform when there is no signal on a Honeywell LTE-XA or LTE-XV. As these are cellular modules, an adequate cell signal is required for them to work properly. You might get a lack of cell signal due to the communicator being used too far from a cell tower, a SIM card that needs to be re-seated, or due to a SIM card that is not yet activated.


Checking the ECP and RIS Address On a Tuxedo

I show you how to check the ECP Address and the RIS Address on a Honeywell Home Tuxedo Keypad. Both the ECP Address and the RIS Address are found in the same menu. The Enhanced Console Protocol (ECP) Address tells the panel where to find the Tuxedo as a keypad controller. Setting the ECP is sometimes referred to as addressing the keypad. The Remote Interactive Service (RIS) Address tells Total Connect 2.0 and AlarmNet where to find the Tuxedo as an automation controller.


Enrolling the DSC PG9914 Motion Sensor to a Qolsys IQ Panel 2 Plus

I show you how to pair the DSC PG9914 Motion Sensor with a Qolsys IQ Panel 2 Plus Security System. The DSC PG9914 is a PowerG Sensor, and it can be used with any version of the Qolsys IQ Panel 2 Plus. The sensor offers a coverage area of up to 39 feet, pet immunity of up to 85 pounds, a wireless communication range of up to 2,000 feet away from the IQ Panel 2 Plus, and 128-bit AES encryption.


Upgrading a Honeywell Lyric to Use LTE

I show you how to upgrade the Honeywell Lyric Controller to support an LTE communicator. In order to do this, you will need a compatible LTE cellular communicator. The compatible modules include the Honeywell LYRICLTE-A AT&T LTE Communicator and the Honeywell LYRICLTE-V Verizon LTE Communicator. You will need to get a monitoring plan that includes cellular connectivity, such as an Alarm Grid Gold or Platinum Level Plan. This is necessary for activating the communicator for monitoring service.

Tags: , , , , , , , , , , ,

Comments


Posted By

It was a relatively calm week for our video team, but we still managed to put up a few new videos. Most of these are usual tutorial videos, but we did make one extra movie for fun at the end of the week. We hope you enjoy these videos. Let's check out the recap for September 18th thru 25th.

Programming a SiXFOB to the Lyric Controller

This video was actually uploaded super late last week, and it missed the last recap, so we decided to put it into this one! I show you how to program a Honeywell SiXFOB Key Fob with a Honeywell Lyric Alarm System. The Honeywell SiXFOB is a 4-button key fob that is great for arming, disarming, and triggering emergency panics. As a member of the Honeywell SiX Series, the Honeywell SiXFOB is designed exclusively for use with the Lyric System, and it uses 128-bit AES encryption for enhanced wireless security.


Remove All Devices Button On IQ Panel 2

I show you the Remove All Devices button in the Z-Wave Menu for the Qolsys IQ Panel 2 Plus. This button serves as a reset for the system's internal Z-Wave Plus controller, and it clears all of the programmed Z-Wave devices from the system. Any Z-Wave device you want to continue using with the IQ Panel 2 will need to be re-added to the system. It will be necessary to clear these devices from the network before adding them back in, as they will still have residual Z-Wave data from when they were paired with the system originally.


Honeywell Home Tuxedo Is Not a Standalone Alarm Panel

I explain how the Honeywell Home Tuxedo Keypad is not a standalone alarm panel. Many users mistakenly believe that the touchscreen keypad is the actual alarm system. But in reality, the Tuxedo is just a keypad controller for a Honeywell VISTA System. The actual panel is usually found in a beige metal cabinet. This metal enclosure is often tucked away in a basement, attic, garage, or storage closet. Do not confuse the Honeywell Home Tuxedo with an actual Honeywell VISTA Security System.


Using Console Mode on a Honeywell Home Tuxedo

I show you how to use Console Mode on a Honeywell Home Tuxedo Keypad. Console Mode allows the Tuxedo to be used in the same way as an Alphanumeric Keypad, such as a Honeywell 6160. Putting the Tuxedo into Console Mode is necessary when programming the system. This includes adding, editing, and deleting system zones and making other various changes to the system settings. Remember that the Tuxedo will automatically reboot as soon as you exit system programming.


Connect Tuxedo Keypad to WIFI

I show you how to connect a Honeywell Home Tuxedo Keypad to a local WIFI network. The reason why the Tuxedo connects to WIFI is to send and receive automation commands from Total Connect 2.0. This internet connection also allows the Tuxedo to receive firmware updates from AlarmNet and display a weather forecast on the main screen. The Tuxedo Keypad can connect with both 2.4 GHz and 5 GHz WIFI networks. Wired ethernet connectivity cannot be used with the Tuxedo.


Mike's Birthday Punches

Okay, this isn't a security system video, but we needed to fit Jarrett into some video for the week. Jarrett punches me 28 times, in honor of my 28th birthday. Jarrett sure packed some heat into his punches, but I took it pretty decently if I do say so myself. I then made sure to remind the viewers to contact support@alarmgrid.com for monitoring information. I'll need to remember to pay Jarrett back on his birthday a few months from now!

Tags: , , ,

Comments


Posted By

Alarm Grid is here with another video recap! This time, we have nine (9) new videos to check out. Jarrett again stepped up this week and did a couple of videos. Our team is thrilled to have him back in the Alarm Grid studio. Let's take a look at the latest tutorial videos from Alarm Grid.

Assigning User Codes to Partitions On the IQ Panel 2 Plus

I show you how to assign user codes to different partitions on the Qolsys IQ Panel 2 Plus. When you have partitions enabled on the IQ2+, you will need to assign partitions to every programmed user code. A user code will only be able to control a partition that it has been assigned. The system's Master Code, also known as the Admin Code, has access to every partition on the system. There are up to four (4) partitions available on the IQ2+.


Getting Into Z-Wave Programming on a Honeywell Home Tuxedo

I show you how to access Z-Wave programming on a Honeywell Home Tuxedo Keypad. In addition to serving as a touchscreen keypad for a Honeywell VISTA System, the Tuxedo is also used as a Z-Wave Plus controller. In order to add, remove, and edit any of the Z-Wave devices used with the Tuxedo, you must access the Z-Wave Programming Menu. This menu is easy to access so that you can begin quickly setting up your home automation network.


Opening the Honeywell SiXCOMBO

I show you how to open up the Honeywell SiXCOMBO Combination Smoke, Heat, and CO Detector. You will normally need to open up the SiXCOMBO to change the batteries and to access the inside sticker with important device information. The SiXCOMBO uses four (4) lithium CR123A batteries, also known as camera batteries, and it has an average battery life of five (5) years. The inner sticker includes information like the device's Serial Number, manufacture date, and more.


The Resideo Tuxedo is Not an Alarm Communicator

I explain how the Resideo Tuxedo is not an AlarmNet Communicator for a security system. Although the Tuxedo connects to a local WIFI network, it does not do so for the purpose of providing IP connectivity for the panel. The Tuxedo merely connects to the internet to relay automation commands from Total Connect 2.0 and for receiving firmware updates. The user must still add a compatible communicator to their VISTA System to set up alarm monitoring.


Using More Than One SkyBell With Total Connect 2.0

Jarrett explains how Total Connect 2.0 allows you to pair up to five (5) SkyBell Video Doorbell devices per account. The account does not need to include true video monitoring service for the SkyBell devices to work. If you want to use more than 5 SkyBell Video Doorbells with Total Connect 2.0, then it is necessary to sign-up for a second account. You can link the multiple accounts so that you can access them using the same login information.


Setting up Total Connect 2.0 Notifications

I explain how to setup text and email notifications in Total Connect 2.0. Text and email notifications help ensure that you are notified regarding any activity on your Honeywell Security System. This is very important for self-monitored users who do not have central station service, as they must receive these notifications and take proper action during emergencies. To set up notifications, you must create user profiles, assign phone numbers and/or email addresses to those profiles, then build notification groups and include the user profiles, and finally assign which notifications go to each group.


Changing the Battery in a Honeywell 5834-4

Jarrett shows you how to change the battery inside of a Honeywell 5834-4 Key Fob. The Honeywell 5834-4 uses a single lithium CR2032 coin battery for power. Expected battery life is roughly three (3) to five (5) years with typical usage. A Phillips screwdriver is needed to remove the back cover for the Honeywell 5834-4 and access the battery compartment. Make sure to observe proper polarity when inserting the new battery. The positive side for the CR2032 battery should be visible, once the battery has been inserted.


Using the Resideo Tuxedo Without an Alarm Panel

I explain how you can technically use the Resideo Tuxedo without an alarm panel. This is not commonly done, as the Tuxedo is primarily a keypad for a Honeywell VISTA System. But you do have the option of providing power to the Tuxedo and using it as a standalone automation controller for Z-Wave smart home devices. Some examples of Z-Wave devices that you can pair with the Tuxedo include smart lights, door locks, programmable thermostats, and more.


Install Honeywell LTE-XA or LTE- XV On a VISTA TURBO

I show you how to install a Honeywell LTE-XA AT&T LTE Communicator or a Honeywell LTE-XV Verizon LTE Communicator on a Honeywell VISTA TURBO Series Panel, such as a Honeywell VISTA-128BPT or a Honeywell VISTA-250BPT. The added communicator will allow the panel to communicate with the AlarmNet servers across a cellular network. This will allow the system to be monitored. The user will need a monitoring plan that includes cellular communication, such as an Alarm Grid Gold or Platinum Plan.

Tags: , , ,

Comments


Posted By

We have another video recap lined up for you! This time there are three (3) new videos to check out. And this happens to be a very special video recap, because our fan-favorite technician makes his much-anticipated return! Let's take a look at the new Alarm Grid videos for September 11th.

Making All Partitions Sound on the Qolsys IQ Panel 2

The man. The legend. Jarrett is back, and he's going to talk about how you make all partitions sound on the Qolsys IQ Panel 2. When you enable partitions on the IQ Panel 2, only sensors on partition 1 will trigger sounds, by default. If you want the system to produce sounds for other sensors, then you must enable the Global Intrusion Sounds and Sirens feature for the system. This will require accessing programming with the Installer Code (default 1111).


Arm Stay and Arm Instant

Jarrett is excited to explain the difference between Arm Stay Mode and Arm Instant Mode. When you Arm Instant, the system ignores Entry Delay periods. This means that if you fault an Entry/Exit Zone while the system is Armed Instant, then the system will go into immediate alarm, instead of giving you a chance to disarm during the Entry Delay countdown. In Armed Stay, you get the Entry Delay when you fault an Entry/Exit Zone. Both Arm Stay and Arm Instant will automatically bypass interior zone types.


Program SiXSMOKE to Lyric Controller

I show you how to program a Honeywell SiXSMOKE to the Honeywell Lyric Alarm System. The Honeywell SiXSMOKE is an encrypted smoke and heat detector built exclusively for use with the Lyric. The smoke detector portion is photoelectric, which means that there is a small light inside the sensor. Smoke entering the chamber will cause the light to refract, which tells the sensor to report to the system. The heat detector uses both fixed temperature detection and rate-of-rise detection. The sensor has an 85 dB sounder.

Tags: , , , ,

Comments


Posted By

It's the first Alarm Grid video recap of September! We have some great new videos to show you, and we're hopeful that you find them helpful in setting up your system. Subscribe to our YouTube channel if you haven't yet, and stay tuned for future videos. Let's check out the newest videos.


Using a Qolsys IQ Panel 2 with a Phone Line

I explain how you cannot use the Qolsys IQ Panel 2 with a phone line connection. Phone line connectivity was once the most common communication path used with security systems. But with the rise of internet and cellular, that is no longer the case. Most newer panels like the IQ Panel 2 don't even have a jack for using a phone line. Instead, the system has built-in WIFI and cellular. Remember that activating for monitoring service with use of Alarm.com requires the activation of the system's cellular communicator.


Removing a Z Wave Device from a Qolsys IQ Panel 2

I show you how to remove, or clear, a Z-Wave device from the network by using a Qolsys IQ Panel 2 Plus. Clearing a Z-Wave device is typically done before enrolling it with the network to ensure that all the network data is properly wiped out. It is also done if the user no longer intends on using the Z-Wave device anymore. It is important to note that a device can still be cleared from the network even if it isn't actively enrolled with a Z-Wave hub.


Program SiXCT to Lyric Controller

I show you how to program a Honeywell SiXCT Door and Window Contact Sensor to a Honeywell Lyric Alarm System. The Honeywell SiXCT is a wireless door and window sensor that uses 128-bit AES encryption for enhanced wireless security. The sensor has a terminal block so that you can use it as a wireless transmitter with a wired contact sensor. The wireless range for the SiXCT is roughly 300 nominal feet, and it has a green LED light to assist with enrollment.


Program SiXMINICT to Lyric Controller

I show you how to program a Honeywell SiXMINICT to a Honeywell Lyric Alarm System. The SiXMINICT is a smaller version of the SiXCT. Unlike the SiXCT, the Honeywell SiXMINICT does not have a terminal block, and the sensor cannot be used as a wireless transmitter. It also has a smaller wireless signal range of only about 200 nominal feet. However, this door and window sensor is smaller than the SiXCT, and many users prefer the more compact design of the SiXMINICT. It retains the same green LED light to assist with enrollment.


Program a Honeywell SiXGB to the Lyric Security System

I show you how to program a Honeywell SiXGB Glass Break Sensor to a Honeywell Lyric Security System. As a member of the Honeywell SiX Series Lineup, the SiXGB utilizes 128-bit AES encryption, and it can only be used with the Lyric System. The wireless glass break sensor actively listens for the sound of breaking glass. It is great for monitoring windows and protective glass casings. The sensor has a detection range of roughly 25 feet, and it needs a direct line of sight to any glass being monitored.


Adding an External Communicator to a DSC PowerSeries NEO

I show you how to install an external communicator for a DSC PowerSeries NEO Security System. The PowerSeries NEO requires an added communicator for connecting with Alarm.com. The communicator connects with the DSC PCL-422 Module, which comes included. Then, a PC-Link cable connection is made between the NEO Panel and the PCL-422. Once the communicator is properly installed, you will need to activate it for monitoring service. Remember that you will need a monitoring plan that offers cellular communication.

Tags: , , , , ,

Comments


Posted By

Alarm Grid is here with another video recap. We're got some informative videos to help you set up and use your security system. Remember to subscribe to our YouTube channel and stay tuned for future videos and other great content. Let's check out the latest tutorial videos from Alarm Grid.


Program SiXPIR to Lyric Controller

I show you how to program a Honeywell SiXPIR with a Honeywell Lyric Alarm System. The Honeywell SiXPIR is a wireless motion detection sensor designed exclusively for use with the Lyric Security System. The sensor responds to changes in infrared energy caused by movement. The SiXPIR has a maximum coverage area of (40) by (56) feet when mounted from a recommended height of (7.5) feet. It supports pet immunity for small animals weighing up to (80) pounds.


Enroll DSC PG9303 to IQ Panel 2 Plus

I show you the process for manually enrolling the DSC PG9303 PowerG Door and Window Contact Sensor with the Qolsys IQ Panel 2 Plus. Manual enrollment refers to the practice of manually entering in the sensor's Serial Number, rather than allowing it to automatically generate through auto-enrollment. Manual enrollment is recommended for the PG9303 if auto-enrollment fails. After manually enrolling, you must activate the sensor's tamper cover to complete the enrollment process. Activating the tamper cover confirms the encryption key that is shared between the sensor and the panel.

Tags: , , , ,

Comments


Posted By

Alarm Grid is back with another video recap! This time, we have six (6) new videos to share. We spent a lot of time this week focusing on the 2GIG GC3e, but we also covered some other security equipment as well. We hope you enjoy this latest batch of videos. Let's check them out!

Alarm grid inside security stickers

Properly Opening Up a 2GIG GC3e

I show you how to open up the 2GIG GC3e Security Panel. Before opening the system, you must loosen the set screw at the bottom. If the panel is wall-mounted, you can press the panel against the wall and lift upward. Otherwise, lay the panel face-down, and pop off the back plate using your finger or a screwdriver. Opening up the GC3e Panel is often done to access the system's terminal block and backup battery.


Powering On the 2GIG GC3e

I show you how to power on the 2GIG GC3e Alarm System. The system uses a 14VDC, 1.7A transformer for primary power. If primary power is lost, then a backup battery will keep the system running. When powering on the 2GIG GC3e, we recommend connecting the backup battery first, followed by the transformer. Alarm wiring is not included with the 2GIG GC3e, so you must supply your own. We recommend using a Honeywell LT-Cable for this purpose.


Deleting a Defective Z-Wave Device from the GC3 or GC3e

I show you how to delete a defective Z-Wave device from a 2GIG GC3 or 2GIG GC3e. Some reasons why a Z-Wave device might be displayed as failed include the device being powered down or out of wireless range. Deleting a defective Z-Wave device is usually a good option if the device is lost or destroyed so that a traditional exclusion process cannot be performed. Any failed Z-Wave device will have an error icon next to it in the Smart Home Devices Menu.


Setting Up a Cellular Communicator for a 2GIG GC3e

I show you how to add a cellular communicator to a 2GIG GC3e Security System. Doing this will allow you to activate the 2GIG GC3e System for monitoring service. And if the monitoring plan includes access to Alarm.com, then you will also be able to control the system remotely through that platform. The 2GIG GC3e has a side slot for you to easily install a cellular radio. Remember to power down the system completely before installing the cellular communicator.


Powering the TG-1 Express Using the On-Board Terminals

I show you how you can power the Telguard TG-1 Express using its on-board power terminals. The Telguard TG-1 Express is used to take over the phone dialer for a panel so that it can communicate across a cellular network. Normally, the TG-1 uses a single RJ31X connection for power and communication with the panel. But if the existing power wires from the RJ31X cable are cut, then you can instead make the auxiliary power connections at the TG-1 on-board terminals.


Properly Closing the Qolsys IQ Panel 2

I show you how to properly close the Qolsys IQ Panel 2 Security System. To properly close the system, you want to align the top tabs first. Then you should lock the bottom two (2) tabs into place. Lastly, make sure the top four (4) tabs remain closed, and click them into place if they are not. The panel will make a strange noise every half-hour if it is not closed properly. The main reason to open the IQ2 is to replace its backup battery every few years.

Tags: , , , , , , , , , , , , , , , , ,

Comments


Posted By

It's time for another video recap! There are eight (8) new videos this week, all featuring yours truly. We spent a lot of time working on the 2GIG GC2e again. We also covered the process for backdooring the Honeywell LYNX Touch Panels, and we touched on the IQ2+. Let's check out the videos!

Alarm grid inside security stickers

Pairing a Z-Wave Device with the 2GIG GC2e

I show you how to pair a Z-Wave device with a 2GIG GC2e Security System. The 2GIG GC2e serves as a Z-Wave Plus controller, which allows you to pair smart home automation devices with the system. Devices can be controlled locally at the panel, as well as remotely from Alarm.com if the system is monitored. There are many types of Z-Wave devices you can use with the GC2e, including lights, door locks, smart thermostats, and more!


Programming a Wireless Zone On a 2GIG GC2e

I show you how to program a wireless zone for a 2GIG GC2e Alarm System. Every sensor used with the 2GIG GC2e will take up at least one zone. The GC2e System has sixty (60) wireless zones available. You can pair sensors from the Honeywell 5800 Series, the 2GIG 345 MHz Series, and the 2GIG eSeries Lineup. We recommend auto-enrolling any new sensor to prevent entering an incorrect Serial Number. Auto-enrolling will also confirm successful communication.


Programming a Key Fob for a 2GIG GC2e

I show you how to program a key fob for a 2GIG GC2e Alarm Panel. A key fob is a small, handheld device that you can use to arm and disarm your system. You can very easily carry around a key fob in your pocket or purse, and they are great for putting on key rings. Popular key fob options for the 2GIG GC2e System include the 2GIG KEY2-345, the 2GIG KEY2e-345, and the Honeywell 5834-4.


Adding & Changing User Codes On a 2GIG GC2e

I show you how to add and change user codes on a 2GIG GC3 Security Panel. The GC2e has (64) user code slots available. You need a valid user code to successfully disarm the system. It is recommended that everyone who uses the system regularly has their own user code so that you can keep track of who uses the system. You can also apply a schedule to a code so that it only works at certain times.


Using the Backdoor to Enter Programming On a Honeywell L5200 or L5210

I show you how to use the backdoor method on a Honeywell L5200 or L5210. The backdoor method involves rebooting the panel and then performing a special sequence of commands as the system reloads. By completing this process, you can get into programming if you were previously locked out. Please note that the backdooring process will not work if the system is currently in an armed state. You will need to disarm the system before you can backdoor.


Getting Back Into Programming On an L7000 If You're Locked Out

I show you how to get into programming on a Honeywell L7000 if you're locked out by using the backdoor method. There are two (2) main reasons why you would become locked out of programming. The first is that the option "NO" was selected at the prompt asking if the installer should be allowed to re-enter programming. Always choose "YES" when exiting programming. The other possibility is that you do not know the Installer Code for the system. Do not change the Installer Code from its default of 4112 to avoid being locked out.


Secure Arming On the Qolsys IQ Panel 2 Plus

I demonstrate the Secure Arming feature on the Qolsys IQ Panel 2 Plus. When Secure Arming is enabled, you must enter a valid user code or the Master Code when arming the system. Normally, the system can be armed without providing a code. Additionally, you must also provide a code if you go to cancel an arming session during the Exit Delay countdown if this feature is enabled. Many parents with small children enable the feature to prevent the system from being armed accidentally.


IQ Panel 2 Exit Delay Increased After Opening Door

I explain why the Exit Delay timer on the Qolsys IQ Panel 2 Plus will automatically increase after opening a door. This is due to a false alarm prevention feature called Auto Exit Time Extension. This feature is activated if two (2) Entry/Exit faults are detected during the Exit Delay countdown. When you fault the first E/E Zone after arming, the system assumes that you have left the building. Then when another E/E fault is detected, the system assumes that you have returned. It then gives you an added 60 seconds to exit the building. If you quickly re-entered the premises because you forgot something, this prevents you from having to disarm and then re-arm the system.

Tags: , , , , , , , , , , , , , , , , ,

Comments