Hi DIYers. We have a relatively small video recap this time. Our team managed to make four (4) new videos. This includes three (3) from Jorge and one (1) from Jarrett. They are both ready and eager to help you learn your security system. Let's check out the new videos for this week.

Arming a Honeywell Alarm System Using Alexa

Jorge talks about how you can use Amazon Alexa to Arm your Honeywell Security System. This is made possible using Total Connect 2.0. You must open the Alexa App on your Android or iOS device and link your Total Connect 2.0 account. In order to use Total Connect 2.0, you will need an alarm monitoring plan that includes access to the service. You can use Alexa to Arm Away, Arm Stay and activate TC2 smart scenes. You cannot use Alexa to Disarm your system.


Low Battery Supervision On The 2GIG TAKE-345

Jorge explains how if your 2GIG TAKE-345 has a low backup battery, then all the associated zones will show a low-battery trouble condition. The 2GIG TAKE-345 is a wired to wireless converter designed for use with 2GIG Security Panels. Hardwired sensors connect with the TAKE-345. The module then sends a 2GIG 345 MHz Signal to the panel. The system sees these sensors as wireless sensors. If the 2GIG TAKE-345 has a low battery, then the associated wireless zones will show low battery. You cannot use hardwired life-safety sensors with the TAKE-345.


Getting Power To The Lyric Security System

Jarrett teaches users how to power the Resideo Lyric Alarm System. The system receives primary power from a plug-in DC transformer. If the electricity goes out, a backup battery will keep it powered on. There are 4-hour and 24-hour backup battery options available. We recommend using a Honeywell LT-Cable to connect the panel to its transformer. You can also use 18-gauge, 2-conductor wire to complete the connection. The system will power off if it is not receiving plug-in or battery power.


Testing My Alarm Panel Through Alarm Grid

Jorge explains how Alarm Grid customers can test their security systems. We recommend testing your system monthly. You must test your system once per year to receive an updated certificate of alarm (CoA). By receiving a CoA from Alarm Grid, you can save money on your homeowner's insurance. You must always put your system on test mode before testing your system. You can put your system on test mode by contacting us, contacting our central station partner Criticom, or use the MyAlarms.com feature.

Tags: , , , ,

Comments


Posted By

Hi DIYers! It's time for another video update from Alarm Grid. This time we're covering the videos from May 30th and 31st. We have six new videos this time. Joe has four, while Jorge and Jarrett each have one. The Alarm Grid boys are back to help you learn your system. Let's check them out.

Connecting an LTE-XV to a VISTA-21iP

The ever-friendly Joe teaches you how to connect a Honeywell LTE-XV to a Resideo VISTA-21iP Security System. The Honeywell LTE-XV is a Verizon LTE Communicator for VISTA Series Systems. It follows the same setup process as the Honeywell LTE-XA, which is the AT&T LTE Communicator. Please note that by adding an LTE-XV or LTE-XA to a VISTA-21iP, you will disable the integrated IP communicator for the system. If you want to use an external dual-path communicator with a VISTA-21iP, you should add a Honeywell LTE-IV instead.


The ADC-V522IR Audio Features

Joe explains the two-way audio capabilities of the Alarm.com ADC-V522IR Security Camera. If you use this camera with the Qolsys IQ Panel 2 Plus, you can livestream the audio and video directly from the panel. You can also get live audio and video from the Alarm.com Mobile App. This app can be conveniently accessed right from your Android or iOS device. You can even speak through your Android or iOS device and have your voice come through the camera. This will allow you to have a live two-way conversation with whoever is at the other end.


Connecting the August Smart Lock Pro to WIFI

Joe helps you connect your August Smart Lock Pro to a WIFI network. To do this, you will need an August Connect WIFI Bridge. Getting your August Smart Lock Pro connected with WIFI is recommended if you want to use the device with Apple HomeKit. However, it is not required. The only other way to use HomeKit with the August Smart Lock Pro is to have your HomeKit Hub within Bluetooth range (10 to 15 feet) of the lock. Your HomeKit Hub can be an iPad, HomePod or AppleTV (4th Generation or higher).


Arm Stay vs. Arm Instant

Fan-favorite Jarrett explains the differences between Arm Stay and Arm Instant. The major difference is that Arm Instant ignores all Entry Delay settings. This means that any Entry/Exit Zones will effectively operate as Perimeter Zones. If you fault an Entry/Exit Zone while the system is Armed Instant, then an immediate alarm will occur. If you want to Disarm the System while it is Armed Instant, you will need to do so without activating an Entry/Exit Zone. We recommend using a Security Key Fob or an interactive service platform like Alarm.com or Total Connect 2.0.


Response Types Supported by the SiXPIR

Jorge discusses the Response Types that can be used with the Honeywell SiXPIR Motion Detecting Sensor. The only available Device Type for a SiXPIR Zone is "Motion Sensor". This restricts the Response Types that can be used. You cannot set the Device Type to "Other" to gain access to the full list of Response Types. As a result, the only Response Types you can use with the SiXPIR are Interior Follower, Perimeter, Day/Night, Interior With Delay, Resident Monitor, Resident Response, General Monitor, and General Response.


Using the August Smart Lock Pro with Apple HomeKit

Joe talks about using the August Smart Lock Pro with Apple HomeKit. By including the August Smart Lock Pro with your Apple HomeKit network, you can operate the lock from anywhere using your iOS device. There are two ways to use the lock with HomeKit. The first is to pair the August Smart Lock Pro with the August Connect WIFI Bridge. This will allow the lock to connect with a WIFI network so that you can access it remotely. The other option is to have the lock within Bluetooth range of your HomeKit Hub. This can be an AppleTV (4th Generation or higher), iPad or HomePod.

Tags: , , , ,

Comments


Posted By

Hi DIYers! We hope that you had a safe and fun Memorial Day weekend. Our video team managed to produce eight (8) new videos last week. Joe was featured in five (5) new videos, mostly covering the August Smart Lock Pro. Jorge and Jarrett both had a video apiece, and I made one as well.

Connecting an August Smart Lock Pro with the August Home App

Joe explains how to connect your August Smart Lock Pro with the August Home App. This is one of the first things you will do with the August Smart Lock Pro. The August Home App allows you to operate your lock from your smartphone. You can control the lock through Bluetooth if you are within 10 to 15 feet. You can also operate the lock remotely from almost anywhere if you have the August Connect WIFI Bridge.


Including the August Smart Lock Pro

Joe shows users how to include the August Smart Lock Pro with a Z-Wave network. This is important if you want to control the August Smart Lock Pro from an interactive service platform from Total Connect 2.0 or Alarm.com. The pairing process is completed through the August Home App. You will need to have the lock paired with the app before you can pair it with a Z-Wave network. You will also need access to your Z-Wave hub or controller.


Defaulting the August Smart Lock Pro

Joe teaches users how to perform a factory default for an August Smart Lock Pro. To perform a factory reset, you will need to access your August account through the August Home App. Doing this will clear any Z-Wave and WIFI settings for the lock. You will need to reprogram the lock from scratch using the app. You should only perform a factory reset if you plan on giving away the lock or as a final troubleshooting step.


Excluding the August Smart Lock Pro

Joe covers the process for excluding the August Smart Lock Pro from a Z-Wave network. Unlike most Z-Wave devices, you don't need to clear the August Smart Lock Pro before adding it to a Z-Wave network. Instead, you will only do this if you are clearing the device from the network so that you can add it to a new one. You can complete the exclusion process through the August Home App. If you don't have access to your Z-Wave hub, you will need to perform a Z-Wave factory reset.


Getting an Alarm or Zone Open or Close to Activate a Honeywell IP Camera

Joe talks about how you can create notifications to have your Resideo IP Cameras activate when sensors are faulted or during alarm events. Normally, these cameras will only activate when they detect motion or sound. You can create these notifications through Total Connect 2.0. It is also possible to set specific hours when a camera can initiate a recording. This way, even if a zone is faulted, the camera will only capture clips during certain predetermined hours.


Temperature Sensor Notifications from a Lyric via Apple HomeKit

Jorge explains how you cannot receive temperature sensor notifications from Apple HomeKit when used with a Resideo Lyric Alarm System. HomeKit will only provide specific alerts for intrusion zones on the Lyric. For all other zones, only a General Lyric System Alert will be displayed. This makes it impossible to determine exactly which zone was faulted. However, you can still use HomeKit alongside Total Connect 2.0. The TC2 service will provide specific alerts for any faulted zone.


Is AlarmGrid Compliant with Nationally Recognized Industry Standards?

In a very rare video appearance, I talk about how Alarm Grid is compliant with Nationally Recognized Industry Standards. Nearly all of the systems and sensors that we sell are certified by Nationally Recognized Testing Laboratories. Additionally, our central monitoring partner Criticom Monitoring Services is UL Listed and FM Approved. While we may occasionally have equipment on our site that is still in the process of being approved by a NRTL, we stand behind our manufacturers and are confident in their offerings.


Finding the Firmware Revision on a Lynx Touch

Coming through with a video at the very last minute, Jarrett teaches users how to find the Firmware Revision on a Resideo Lynx Touch System. If you want to perform a firmware update for these systems, then you will need the LYNXTOUCH-MSD Updater Tool. It is no longer possible to push an update over-the-air (OTA). Getting these systems on the latest firmware is important if you plan to use an LTE cellular communicator. Please note that you will also need an alarm monitoring plan that includes cellular connectivity.

Tags: , , , , , , , , ,

Comments


Posted By

Hi DIYers! We're here with a small video recap, covering May 16 & 17. It was a quiet week for our video team, as we only had five new videos. But we gotta give some credit to Jorge, as he cranked out four videos. Jarrett also came through with one. Let's take a look at the videos.

Adding a Profile Image to a Total Connect 2.0 Account

Jorge shows users how to add a profile image to their Total Connect 2.0 account. Each user on a TC2 account can have their own profile image. This helps to add a nice personalized touch to Total Connect 2.0. Any uploaded image will only be visible from TC2. It will not be visible from the panel. If you have multiple users on the same Total Connect 2.0 account, then each user can have a unique picture.


Adding a Location Image to a Total Connect 2.0 Account

Jorge teaches users how to add a location image to a Total Connect 2.0 account. Each location on a TC2 account can have its own picture. You will have a different location for each system on your Total Connect 2.0 account. This is great for users with multiple homes or businesses. Adding a unique image for each location can be a great way to differentiate them. This way, you can be sure that you are controlling the correct system when you use TC2.


Smart Home Items That are Compatible with the Honeywell Lyric

Jarrett talks about smart home items that are compatible with the Honeywell Lyric Controller. The system has a built-in Z-Wave controller for operating Z-Wave devices. Any Z-Wave device can be operated through Total Connect 2.0. The Lyric is also one of the few systems on the market that is compatible with Apple HomeKit. You can have your HomeKit devices set to respond based on activity that affects your system. It is also possible to control your Lyric through your iOS device.


Changing the Installer Code Using a Tuxedo Touch Keypad

Jorge explains how to change the Installer Code for a Honeywell VISTA Alarm System using a Tuxedo Touch Keypad. The Installer Code is the code used to enter programming and make system changes. We encourage most users to keep the code at its default of 4112. This will prevent users from being locked out of programming later. If you forget the default Installer Code, you can always look it up later. If you change the code and forget it, you will need to use the backdoor method to get back into programming.


Features Added in the 2GIG GC2 1.19 Firmware Upgrade

Jorge discusses Firmware Version 1.19 for a 2GIG Go!Control GC2 System. Upgrading to the latest firmware is very important for getting the most out of your system. Firmware Version 1.19 added support for various cellular communicators. If you want to use an AT&T LTE communicator, then you need Firmware Version 1.19.3. You can have a firmware update pushed down automatically to your panel from Alarm.com for a small fee. If your panel is not connected with Alarm.com, you will need an upgrade cable or an upgrade tool to complete the process.

Tags: , , , ,

Comments


Posted By

Hi DIYers! We hope you had a great Mother's Day weekend. Last week, our video team put up a bunch of new videos, 9 to be exact. All were posts on Thursday and Friday. We love helping users get the most out of their alarm systems and smart home networks. Let's take a look at the new videos!

Updating the Firmware on a Lyric Alarm System's SiXFOB

Jarrett kicks things off by showing you how to update the firmware for a Honeywell SiXFOB Key Fob. This key fob is designed exclusively for use with the Honeywell Lyric Controller. Unlike most SiX Series devices, the SiXFOB needs to receive firmware updates manually. The Lyric should be running the latest firmware version before performing the update. Updating the firmware for the SiXFOB will ensure that it works as effectively as possible. Updating the firmware will affect any zones associated with the SiXFOB.


Including a Schlage Z-Wave Lock

The ever friendly and helpful Joe shows you how to include a Schlage Z-Wave Lock into your local Z-Wave network. Pairing your Z-Wave lock is necessary for getting the most out of the device. You need to do this to control the lock remotely and to use it with smart scenes. Pairing a lock with an alarm panel is often a great option. You can then use it with an interactive service platform like Total Connect 2.0 or Alarm.com. Please note that you will need a monitoring plan with access to one of these services.


Excluding a Schlage Z-Wave Lock

Joe helps you some more by showing how to exclude your Schlage Z-Wave Lock from a Z-Wave network. This is an important step if you plan to transfer the lock from one Z-Wave hub to another. You should also do this before completing the initial pairing process. Many Z-Wave smart home devices are paired with Z-Wave networks before they even leave the factory for testing purposes. Clearing the lock first will ensure that you can pair it successfully.


Adding a Siren to the Qolsys Hardwire 16-F

Joe is back again, and this time he's gonna show you how to add a siren to a Qolsys IQ Hardwire 16-F. This is a wired to wireless converter that allows you to use hardwired sensors with a wireless 319.5 MHz system. The module was specifically designed with the Qolsys IQ Panel 2 Plus in mind. What's unique about the Qolsys IQ Hardwire 16-F is that it includes siren terminals and a built-in siren relay which can be controlled wirelessly by the panel. No external relay is needed for the connected siren, as long as the Qolsys IQ Panel 2 has a hardware RF PIC version 11.1.4 G2 or higher.


Powering the Honeywell Vista-20P

If you just can't get enough of Joe, then you're in luck! He will show you how to provide power to your Honeywell VISTA 20P Hardwired Security System. The panel receives power through two sources. Its primary power source is a plug-in transformer, specifically the Honeywell 1321. If the electricity goes out, then the system can remain powered on through its backup battery. We recommend using an UltraTech 1240 for this purpose. All of this equipment can be purchased from the Alarm Grid site.


How Alarm Systems Work

Hey look, it's Jorge! He's going to explain how alarm systems work. The centerpiece of every alarm system is the control panel. This panel receives signals from sensors that are used throughout the premises. There are sensors for letting the system know if a door or window is opened, if there is movement in the area, if glass is broken, if there is a fire, or really almost any troubling condition that warrants your attention. The system then responds based on the zone configuration and its current arming state.


The Tuxedo Touch - Not An AlarmNet Communicator

If you think the Tuxedo Touch WIFI is an AlarmNet Communicator, then you are sorely mistaken. Jorge is here to set the record straight and explain that the Tuxedo Touch is not a communicator. It is just a touchscreen keypad used with VISTA Series Systems. The keypad uses WIFI connectivity to transmit Z-Wave home automation signals to and from Total Connect 2.0. But you will still need a separate communicator for connecting your system with the AlarmNet Servers.


Programming Report Codes For a Self Monitoring Plan With Alarm Grid

Let's say you sign-up for a self-monitoring plan with Alarm Grid. Great! But since you are self-monitored, you don't need your system reporting out to a central monitoring station. Jorge will show you how to disable the reporting codes for your system so that it functions properly. This process is only necessary for self-monitored systems that use Total Connect 2.0. You do not need to disable report codes for Alarm.com Systems, since Alarm Grid can do it from their end.


Defaulting a Schlage Z-Wave Lock

Joe returns to tell you how to default a Schlage Z-Wave Lock. By performing a factory reset, the lock will be restored to its factory default settings. This will clear any Z-Wave settings, as well as any codes programmed for the device. You will need to re-add the lock to your Z-Wave network. You should check the programming sticker on the lock to find the default user codes. The programming sticker is found underneath the device's main cover.

Tags: , , , , , , ,

Comments


Posted By

Hi DIYers! Last week was interesting for us, as we scrambled to get up some new content by the end of the week. We managed to upload seven new videos. This includes five from Joe, who was this week's MVP. We hope that you enjoy our latest videos and how they help you use your equipment.

Viewing an ADC-SVR122 Remotely

Joe explains how users can view video footage stored on an Alarm.com ADC-SVR122 Stream Video Recorder remotely. The ADC-SVR122 stores footage so that it can be viewed on Alarm.com. The footage can be viewed from Alarm.com, both through the website and through the mobile app. The ADC-SVR122 will need to be integrated with the user's Alarm.com account for this to work. The integration must be done from the Alarm.com website by choosing the option "Add Video Device". Up to eight (8) Alarm.com Cameras can be used with a single ADC-SVR122.


Excluding a Kwikset Z-Wave Lock

Joe teaches users how to exclude a Kwikset Z-Wave Lock from a Z-Wave network. There are a few different instances when you may want to exclude a Z-Wave lock. This step is important to perform before trying to the device to the network. Even if the lock is brand-new, it may have been previously paired with a network for factory testing purposes. You might also try excluding a lock and then re-adding it to the network as a possible troubleshooting step.


Factory Defaulting a Kwikset Z-Wave Lock

Joe demonstrates how to factory default a Kwikset Z-Wave Lock. Performing a factory reset is normally performed when a user inherits the lock from someone else and they want to start fresh with factory default settings. A user may also perform a factory default as a last ditch method for troubleshooting the device. Performing a factory default will clear all programmed user codes and remove all Z-Wave settings. The lock will need to be re-enrolled after performing the default.


Including a Kwikset Z-Wave Lock

Joe covers the process for including a Kwikset Z-Wave Lock into a Z-Wave network. This requires a Z-Wave controller or hub. By pairing a Z-Wave lock, you will be able to control it remotely from an interactive service platform on your smartphone. This is great if you ever need to let someone inside your home while they are away. You can then remotely lock the device after they leave. Z-Wave devices can also be set to activate based on a schedule or with certain predetermined events.


Glass Break Simulators

Joe talks about glass break simulators and how they are used. These devices will produce a sound that is specifically designed to activate glass break detectors. This is great for testing glass break sensors and making sure that they are detecting sounds and working properly. Most security equipment manufacturers have their own glass break simulators that they recommend for use with their equipment. Alarm Grid offers three (3) glass break simulators, which are the Honeywell FG701, the DSC AFT-100 and the Interlogix 5709C-W.


Carbon Monoxide Sensor Notifications from a Lyric via Apple HomeKit

Jorge discusses why a user will not receive specific carbon monoxide sensor notifications from Apple HomeKit when the CO sensor is used with their Lyric Alarm System. When HomeKit is used with the Lyric System, HomeKit will only provide specific notifications for burglary and intrusion zones. HomeKit will not provide specific alerts for life-safety zones. Instead, the user will only receive a General Lyric System Alert. That is why it is important to use Total Connect 2.0 alongside HomeKit. Unlike Apple HomeKit, Total Connect 2.0 will let you know exactly which zone was faulted, regardless of Response Type.


Programming Options Accessible Via Installer Code on the Lyric Alarm

In his triumphant return, Jarrett explains the programming options that can be accessed from the Installer Tools Menu on the Honeywell Lyric Controller. This menu is accessed using the system's Installer Code, which should be kept at its default of 4112. The Installer Tools Menu offers many options that allow the user to make changes to the system settings. This includes adding new sensors and configuring the communication path settings for the panel. You can also access Installer Tools to perform a factory default or to reset the Master Code to 1234.

Tags: , , , , ,

Comments


Posted By

Hi DIYers! It's time for a new video recap. Our video team has settled down and gotten back in the swing of things since ISC West 2019. This time, we have six new videos for you to check out. The videos feature Jorge and Joe to help you learn how to use your alarm system. Let's take a look!

Fire Sensor Notifications from a Lyric via Apple HomeKit

Jorge explains why users don't get specific notifications regarding fire-safety sensors on their Honeywell Lyric Alarm Systems from Apple HomeKit. The important thing to remember is that HomeKit only provides specific notifications for security Response Types. If a life-safety sensor like a smoke detector or a CO detector activates, then HomeKit will only provide a General Lyric System Alert. That is why it is important to continue to use the Total Connect 2.0 platform alongside the Apple HomeKit service. Total Connect 2.0 will provide specific notifications for any Response Type.


Excluding A Yale Z-Wave Lock

Joe shows users how they can exclude a Yale Z-Wave Lock from their Z-Wave network. You should always make sure to exclude a Z-Wave device before attempting to pair it with a Z-Wave network. The Z-Wave device may have been paired with a different network for factory testing purposes. Clearing the lock from the network first ensures that it will be able to pair successfully. Please note that the exclusion command for Yale Z-Wave Locks is [Master PIN] + [#] + [7] + [#] + [3] + [#].


Defaulting A Yale Z-Wave Lock

Joe demonstrates the process for performing a factory reset on a Yale Z-Wave Lock. Doing this will reset the Master PIN Code back to 12345678, delete any added codes and reset any configured Z-Wave settings. The device will need to be re-enrolled with a Z-Wave controller after doing this. You will still need to exclude the device from the Z-Wave network before you will be able to re-enroll it. The factory reset process is performed by pressing and holding the reset button as you apply power to the lock.


Including A Yale Z-Wave Lock

Joe helps users with including a Yale Z-Wave Lock into a Z-Wave network. The process involves putting the Z-Wave controller or hub into its inclusion mode and then activating the inclusion function on the Yale Z-Wave Lock. You should clear the lock from the network before you attempt to perform the enrollment process. The command for activating the inclusion function on the lock is [Master PIN] + [#] + [7] + [#] + [1] + [#]. You may need to configure the lock settings after enrollment.


Keyfobs That Are Compatible With the IQ Panel 2 Plus

Jorge shows users which key fob devices are compatible with the IQ Panel 2 Plus. This depends on which type of IQ Panel 2 Plus System is being used. These systems can support 915 MHz PowerG Key Fobs and one type of legacy frequency (319.5 MHz, 345 MHz or 433 MHz). The 319.5 MHz varieties support Qolsys Key Fobs and Interlogix/GE Key Fobs. The 345 MHz varieties support Honeywell 5800 Series Key Fobs and 2GIG Key Fobs. The 433 MHz varieties support Legacy DSC Key Fobs.

Putting the 2GIG GC3 into RF Learn Mode

Jorge shows users how to put a 2GIG GC3 Alarm System into its enrollment mode for learning-in new sensors. This is a necessary step when you go to add new equipment to your GC3 System. After you have accessed the wireless zone you want to configure, you can choose the "Serial Number" field. This will give you an option to put the panel into its wireless enrollment mode. You can then activate the sensor to learn it in. You must configure the zone settings after enrollment.

Tags: , , , ,

Comments


Posted By

Hi DIYers! We had our video team working crazy hard covering ISC West 2019. But now it's back to the grind with our usual video updates! We managed to get up four new videos for April 18th and 19th. Kudos to our technicians for working so hard. Let's take a look at our latest videos!

Connecting the Honeywell Tuxedo Touch To WIFI

Jorge demonstrates the process for connecting a Honeywell Tuxedo Touch Keypad to a WIFI network. The Tuxedo Touch must be connected to the network so that it can communicate properly with Total Connect 2.0. Proper network connectivity is necessary for the keypad and the Total Connect 2.0 platform to remain constantly in sync. Whether a user operates a Z-Wave device or a smart scene from TC2 or their Tuxedo Touch Keypad, the other platform will receive notice regarding the device activity.


Factory Resetting a Tuxedo Touch Keypad

Jorge shows users how to perform a factory reset on a Honeywell Tuxedo Touch Keypad. By performing a factory reset, all device settings and configurations will be restored to their default values. This is a good option if you are taking over the Tuxedo Touch Keypad from someone else and you want to start fresh with original settings. A factory reset might also be performed as a final troubleshooting step if the device is not working properly. But keep in mind that the entire keypad will need to be reconfigured!


Testing the 2GIG SMKT3-345 Smoke and Heat Detector

Jorge teaches users how they can test a 2GIG SMKT3-345 Smoke and Heat Detector. The device has a test button that allows a user to test the device's LED light, sounder and signal transmission. But you must perform a manual test if you want to check the functionality for the sensor. This means using canned smoke to test the photoelectric smoke detector and a hair dryer on the highest setting to test the heat detector. Remember to place your system on test mode before testing!


ADC SVR122 Feature Overview

Joe talks about the ADC-SVR122 Stream Video Recorder. The Stream Video Recorded is designed exclusively for use with Alarm.com Security Cameras. It allows a user to achieve a 24-hour continuous recording schedule. The user can login to their Alarm.com account through the website or mobile app to view recorded clips that are stored on the ADC-SVR122. They can also connect an HDMI monitor for local viewing. The ADC-SVR122 can support up to eight cameras, and it comes in 500GB and 1TB storage options.

Tags: , , , , ,

Comments


Posted By

Hi DIYers! Our video team was super productive over the past week, as they put up nine new videos for us all to enjoy. Jorge, Jarrett and Joe are all back and ready to help you get the most out of your system. Let's take a look at the latest content from the Alarm Grid video team.

Adding Additional User Codes to a Qolsys IQ Panel 2

Jarrett teaches users how to add additional codes to the IQ Panel 2. User codes can be assigned as a "Master", "User" or "Guest. A Master User can change system settings in addition to arming and disarming. Despite the name difference, there is actually no difference between "User" codes and "Guest" codes, as they have the same authority level. Any new system code that is added will be available on Alarm.com for further control and configuration.


Disabling Chime on a Qolsys IQ Panel 2

Jarret demonstrates how to disable the Chime function for the Qolsys IQ Panel 2 System. Normally if a zone has Chime enabled, then the panel will produce a brief Chime tone when the associated sensor is activated. However, you can disable Chimes for the entire system so that no faulted zones result in a Chime. You can also configure the Chime settings individually for each zone so that some sensors result in a chime, while others do not.


Muting the Honeywell 5828V Wireless Keypad

Jorge explains how users can mute the voice annunciation function for the Honeywell 5828V Keypad. By muting the keypad, no voice annunciations will be produced when zones are faulted. It will also not announce any changes in the current Arming state. However, this will not affect voice annunciation for the panel itself if it has the feature enabled. Additionally, muting the keypad will not stop the device from producing tones when buttons are pressed. It only affects spoken voice.


Controlling the Volume in a Honeywell 5828

Jorge demonstrates how users can adjust the volume on a Honeywell 5828. This will affect the tones produced when keypad buttons are pressed. Unlike the the Honeywell 5828V, the standard Honeywell 5828 is relatively basic it terms of volume control. The volume can only be adjusted one level at a time, and it cannot be muted entirely. The keypad can be used with any LYNX Touch Panel and any Honeywell VISTA Panel that has an added wireless transceiver.


Updating the Firmware on a Qolsys IQ Panel 2

Jarrett covers the process for updating the system firmware on a Qolsys IQ Panel 2. Performing a firmware update is often necessary for unlocking newly released system functions and capabilities. The IQ Panel 2 System will need to be connected with a local WIFI network and be running on transformer power for the update to go through. It also cannot have a low-battery condition. You can search the network for an update or apply a Patch Tag.


Basics of Alarm Keypad Operation

Jorge teaches users the basics of how to use an alarm system keypad. The main purpose of a keypad is to provide an on-site access point for controlling an alarm system. This includes Arming and Disarming. A keypad can be either a primary controller or a secondary access point depending on the system. A primary controller is used performing deep-level programming changes. If you use a keypad as a primary controller, you should make sure it is an Alphanumeric Keypad. A Fixed-English keypad cannot be used for deep-level programming.


Installing the Qolsys IQ Card-IS to the Qolsys IQ Panel 2

Joe shows users how to install the Qolsys IQ Card-IS inside the IQ Panel 2 System. The IQ Card-IS module allows you to use Qolsys Image Sensors with the system. These devices use PIR technology to detect motion. If motion is detected, the image sensor will take a photo and send it to Alarm.com. Since the IQ Card-IS uses the same antenna as the PowerG daughtercard used with the IQ Panel 2 Plus, it is only recommended to be used with the standard version of the system.


Resetting a Honeywell Tuxedo Keypad

Joe explains the different methods for resetting a Honeywell Tuxedo Touch Keypad. There are four reset options that can be performed. A Keypad Reboot Reset will simply power cycle the device. A Keypad Factory Reset will restore all settings and configurations to default, without clearing Z-Wave devices. But the Z-Wave devices will have their names reset. A Z-Wave Reboot Reset will power cycle the Z-Wave controller, without clearing devices. A Z-Wave Factory Reset will default all Z-Wave setting and clear all Z-Wave devices.


Qolsys Hardwire 16-F Overview

Joe goes through and explains how the Qolsys Hardwire 16-F functions. This is a wired to wireless converter that can support 2-wire smoke detectors on its 16th zone. It is primarily used for allowing wired sensors to communicate with wireless panels. The module works with nearly any system that accepts the 319.5 MHz frequency. Each zone terminal on the Hardwire 16-F must have a 4.7k end of line resistor, even if the zone is not used. Additionally, you must properly configure a zone as NC or NO before enrolling with the panel.

Tags: , , ,

Comments


Posted By

Hi DIYers! Our team is back with another video recap. We have six new videos this week, as it was a dead even split between Joe, Jarrett and Jorge. Each of our talented actors had two new videos apiece. Let's take a look at the latest videos from the Alarm Grid Video Production Team!

Factory Resetting the Honeywell Lynx Touch L7000

Jarrett puts on a smile as he shows users how to perform a factory reset on a Honeywell L7000 System. This is accomplished by loading one of the Default Configurations. By performing a factory reset, the entire L7000 System will need to be reprogrammed from scratch. All sensors will need to be relearned with the panel, and all system settings will be reset to their default. Additionally, the Master Code will be reset to its default of 1234, and the Installer Code will be reset to its default of 4112.


Bypassing a Sensor in Total Connect

Jarrett happily demonstrates how to bypass zones in Total Connect 2.0. When you bypass a zone, the associated sensor will remain inactive and be unable to cause a system alarm. For example, if you bypass a door sensor when arming your system, then people will be able to open and close that door without causing an alarm. However, all other system zones will still remain active as usual. Sensors must be bypassed individually for each Arming session.


Addressing a Honeywell Alarm Keypad

Joe explains how to address a Honeywell Alarm Keypad with a Honeywell VISTA Security System. Touch-button keypads use addresses 16 thru 23 on VISTA P-Series Panels. Address 16 is always enabled, while addresses 17 thru 23 must be specifically enabled within programming. Meanwhile, an Advanced User Interface (AUI) device will use address 1, 2, 5 or 6. Touchscreen keypads are considered AUI devices and will use one of these slots. Remember that the Total Connect 2.0 platform itself takes up an AUI slot.


Using the Lynx Touch with a 3rd Party Z-Wave Controller

Joe talks about how how you can use a Honeywell LYNX Touch System as a secondary Z-Wave controller. This is done by pairing the system itself with a different Z-Wave hub. All Z-Wave devices from the primary hub will be automatically pushed over the LYNX Touch System. They can then be controlled from both the primary controller and from the LYNX Touch. However, you will need to use the primary controller to learn-in new Z-Wave devices. You must install an L5100-ZWAVE Card in the LYNX Touch System to support any Z-Wave functionality.


IP Fault Time Setting on the Lyric Alarm Panel

Jorge with his colorful hair discusses the IP Fault Time Setting on the Honeywell Lyric Controller. This setting will have the system display a trouble condition whenever the WIFI goes down for a certain period of time. That way, the user will know later that the system was unable to communicate with the AlarmNet Servers. An IP Fault Time trouble will only appear on the panel if WiFI is set as the only communication path. If the system has a cellular backup, then only the central station will receive an E350 Communication Path Failure on Zone 951.


Programming a Honeywell 5800CO Into an All-in-One Panel

Jorge walks users through the process of programming a Honeywell 5800CO with a wireless alarm system. The Honeywell 5800CO is a carbon monoxide detector that operates at 345 MHz. It is primarily used with Honeywell Systems, but it will work with nearly any panel that accepts the 345 MHz frequency. The sensor will cause an instant system alarm when activated. All building occupants should vacate the premises immediately if a CO alarm occurs. When programmed as a 24-Hour Carbon Monoxide Zone, the 5800CO Sensor cannot be bypassed.