Press Releases Posts

Posted By

Effective in August of 2022, Alarm.com is ending sales of Alarm.Com Image Sensors (ADC-IS-220-GC and ADC-IS-300-LP). Alarm Grid has already discontinued these sensors due to the fact that they are in short supply, and no more of them will be produced. Only the Honeywell Home PROINDMV remains.

The 2GIG IMAGE3:


There was some overlap between the Alarm.com Image Sensor models, and the 2GIG and Qolsys Image Sensor models. I have confirmed with Alarm.com that the 2GIG and Qolsys models are also discontinued as of August, 2022. Currently, the only Image Sensors being offered by Alarm Grid are the DSC PowerG and Honeywell Home PROINDMV models which are discussed in more detail below.

Image sensors were a great idea that never really took off. The original image sensors, first offered by 2GIG and Alarm.com, did not have particularly good resolution or picture quality, which is probably one reason they weren't widely adopted by the DIY crowd. By the time the 2nd generation of these sensors came around, people were prepared to simply go with full-on video monitoring or to avoid capturing images altogether.

Both the second and third-generation image sensors that were offered by 2GIG, Qolsys, and Alarm.com had very good image quality. Combine that with Alarm Grid's policy of offering monitoring for image sensors without an additional price markup, and the image sensor was a viable alternative to the use of video cameras. An Alarm.com user could log into their account and perform a "peek-in", meaning they could request that a particular image sensor grab a picture of whatever it was able to see at that moment, and the image (actually two (2) images) would then be uploaded to the customer's alarm.com account for viewing. The sensor could also take images upon sensing motion after a particular period of inactivity, or upon an alarm. For full details on image sensor features and operation, check out this prior post.

DSC offers a couple of PowerG PIR Cameras that will work with the Qolsys IQ Panel 2 and IQ Panel 4 in addition to the DSC PowerSeries Neo panels with a PowerG Transceiver added. These are the DSC PG9934P, Indoor PIR Camera, and the DSC PG9944, Outdoor PIR Camera. These sensors work like any other PowerG Sensor with the Qolsys Panels. They can only capture images when the system is armed and the image sensor is active (not bypassed). They send their images to the panel, and then the first image is uploaded to Alarm.com. A total of ten (10) images are taken, and these images are stitched together by the panel into a sort of stop-motion video where each image can also be viewed individually. This is done via the panel screen itself. When used with the PowerSeries Neo panels, the DSC PIR Cameras can be used for Visual Verification only, they do NOT work like a regular image sensor with Alarm.com.

DSC PG9934P, Indoor Image Sensor:

DSC PG9944, Outdoor Image Sensor:


The Honeywell Home PROINDMV is a wireless PIR motion sensor with a camera built-in, just like the 2GIG, Qolsys, and Alarm.com image sensors were. The PROINDMV is currently only supported on the Resideo PROA7PLUSC, and Honeywell Home PROA7PLUS panels. There is no "peek-in" option for these image sensors. They can only capture images when they sense motion while the system is armed in Away mode. Images or videos are captured and uploaded to Total Connect 2.0 for viewing. The user can choose to receive either a still image or a 10-second video clip. You can read their full details of operation in our previous post.

Honeywell Home PROINDMV:


It seems like the era of the image sensor may be coming to a close, at least for now. Who knows, once we're through the global chip shortage, and the availability of components is back to normal, perhaps the humble image sensor will experience a revival. If so, DIYers may want to consider giving these sensors a try. They really are an excellent idea. They can be used for alarm verification in this age of increasing police resistance to alarm response, and they are cheaper, both initially and on an ongoing month-to-month basis, than video cameras.


Tags: , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

An announcement on the AlarmNet360 page shows that they will send a remote reset command to some LTEM-PA, LTEM-PV, LTEM-PIA, and LTEM-PIV radios. This will occur today, Friday 04/15/22 between 2:00 pm - 3:00 pm ET. This may cause a trouble condition, and queued alarm reports could be sent.

It's unclear why this is being done. After a successful reset occurs, the radio will send an "E339-EXP. Module Power ON / Reset" message to the monitoring station. If the radio was in comm failure prior to the reset and any unsent alarm signals were queued, this reset may cause those alarm messages to be sent. These signals would show up immediately following the E339 signal at the central station. We assume this would also cause the same alarm messages to show up in Total Connect 2.0, and to be sent as notifications.

In addition, depending on how the panel is programmed, this event may cause the panel to display a bF or Check 103 message, and could also cause trouble beeping from the keypad. Disarming the system twice should clear the message and return the system to its normal state.

Tags: , , , , , , , , , , , , , , , , , ,

Comments


Posted By

Resideo has been investigating an issue with a very small number of communicators. The LTE-CFV, HWF2V-COM, LTE-IV, LTE-L3V, and VISTA-21IPLTE with LTE-21V. In a few cases, starting on March 19, 2022, the Verizon LTE SIM has become locked, causing a comm failure, or secondary path failure.


A device with this issue will show the following symptoms: Locally at the device, the LEDs will flash regularly at a rate of two times per second (see video above). Through AlarmNet360, the affected devices will have checked in normally for the period leading up to March 19, 2022. Then beginning on that date, or on a subsequent date through March 28, 2022, a comm failure will be indicated. Once the comm fail indication appears, it will not clear, so if you've had a comm failure during this time that has restored, then your communication failure is not being caused by this issue.

In addition to the above evidence of an issue, the alarm panel that the communicator is connected to will have a trouble indication displayed. This may come in the form of a Check 103, or a bF on VISTA-20P and similar panels, and also the L3000 panel. For the L3000 panel, the bF will only show on an RF keypad, such as the 5828 or 5828V, the panel itself will show Check or Fault 103. To silence any trouble beeping, enter a disarm command at any panel keypad. These trouble messages can be caused by other things, not just this issue, so if you see one of these error messages and think you may be affected, be sure to contact your alarm dealer for further assistance.

Bear in mind that only the communicators listed above are affected, and that these are all Verizon SIM Cards. If you have an AT&T Communicator, you needn't worry about this issue. Also, for those who have a dual-path communicator with Ethernet connected, you will not necessarily see a Communication Failure message. Instead you will be notified of a Secondary Path Failure. Again, if you are affected by this issue, once the failure occurs, it will not restore. So if you've received a Secondary Path Failure that has since restored, then you experienced a separate issue.

Again, if you feel that you have been affected by this issue, contact your alarm dealer. They can confirm if you are affected and will be able to assist you in receiving a replacement SIM. Alarm Grid customers who are affected have already been contacted and replacement SIMs are on the way. If any further information becomes available, we'll update this post with further details.

Tags: , , , , , , , , , , , , , , ,

Comments


Posted By

ISC West, the security industry's largest trade show, was held this week in Las Vegas. This is the first year since the COVID-19 outbreak that the show is being held in person. We didn't attend the show this year, but based on what we've seen, JCI and Qolsys won the ISC West show in 2022.

Qolsys:

IQ Pro

Qolsys, Inc. which was acquired by Johnson Controls in 2020, premiered two brand new products, and reintroduced one more. The IQ Pro Panel is a hybrid wired and wireless system which targets large homes, and medium to large businesses. It combines the reliability of hardwired components with the range and versatility of the DSC PowerG Sensor lineup. The product is planned for release in Summer, 2022.

There is very little information available about the IQ Pro. The Press Release announcing the product, which was released by Johnson Controls, didn't even say for certain that it would be a Qolsys branded product, though with 'IQ' as a part of the name, we assume it will be. This panel will combine elements of the IQ Panel 4 with the DSC PowerSeries Neo, and a little bit of customer feedback thrown in. A couple of things we do know, the IQ Pro will offer the choice of either Ethernet or WIFI connectivity along with LTE. This panel has been designed with Alarm.com for Business in mind, to take advantage of all the extended features offered there.

IQ WIFI 6

The Qolsys IQ WIFI 6 was actually first introduced to us here at Alarm Grid last year. It is a product we thought was going to released then, but it was introduced at ISC West and should be available in Summer, along with the IQ Pro. The IQ WIFI 6 is is a router that uses 802.11 1/b/g/n/ac/ax WIFI-6 technology. It offers dual-end 2.4 GHz and 5 GHz MIMO mesh architecture on a Qualcomm Networking Pro 400 platform. It will integrate with Qolsys touchscreen panels, to allow a user to administer the network from there.

The IQ WIFI 6 will offer four (4) network partitions, including a Guest Network and a dedicated network for the end-user's WIFI devices. Both of these will switch automatically between 2.4 GHz and 5GHz for seamless optimization of WIFI performance. In addition to these partitions, there are two (2) private network partitions to be used by security and/or networking providers. By separating the security, surveillance, and smart home devices from the rest of the network, professional providers can cut down on disruptions caused by user error.

IQ Hub

The Qolsys IQ Hub has actually already been released, in a limited fashion within the last six (6) months or so. Presumably due to supply chain issues, Qolsys has tightly controlled how many of these panels are shipped, but now, based on a press release this week, it seems like they may be looking to perform a wider release. The IQ Hub differs from the IQ Panel 4 in several ways, one of which is that each panel will only support one RF product line. There is a PowerG version with either an AT&T or Verizon communicator. This is the only version that has been released at this time. Soon however, there will be a version that supports unencrypted, uni-directional Honeywell and 2GIG wireless sensors, one that supports unencrypted, uni-directional Interlogix and all Qolsys wireless sensors, and a version that supports uni-directional DSC 433 MHz wireless sensors.

Resideo:

Cellbounce

Resideo and Honeywell Home brought the Cellbounce to ISC West. This device will bridge communicators that work on the AT&T 3G network over to the AT&T LTE network, without having to replace the device. This is a plug-n-play device. It connects to an outlet within range, which is 25' (7.62m), of the existing AT&T 3G communicator, though be sure not to plug the Cellbounce in until it has been configured by your alarm dealer.

It syncs to the 3G communicator, then with the LTE network and any signals sent by the communicator will be picked up and transported via LTE. It even works with Total Connect 2.0, though it does not work with two-way voice. It also only works in the contiguous United States, so Alaska, Hawaii, and Puerto Rico residents, the Cellbounce is not for you. There are some other caveats and limitations, so be sure to read our product description carefully before purchasing.

2GIG, Nortek Control:

2GIG Edge

In October of 2021 Nortek Control, the parent company of 2GIG, was purchased by Nice. Nice originated in Italy, with Nice North America handling the US and Canadian segment of the business. This year at ISC West, Nice put their stamp on this relatively new acquisition. In addition to some commercial camera innovations by Linear, Nice/Nortek Control announced during ISC West that they will offer exclusive integration between the 2GIG Edge security panel and the ELAN Home Control platform. The Edge has been out for about a year now. You can read all about it here.

According to their press release, this integration will be supported by the ELAN SC-100 and ELAN SC-300 system controllers running ELAN 8.7 OS (which won't be available until April, 2022). The 2GIG Edge panel requires firmware version 3.1.1.0 or later. Firmware can be pushed through Alarm.com or downloaded. This panel firmware version is not available from 2GIG just yet, but once it is posted, our page will be updated. One of the more convenient features of this integration is the ELAN Control Auto Zone Detection feature. If the ELAN system is setup first, with zone names, once the 2GIG Edge is installed, it can download all zones and zone names directly from ELAN, without having to re-enter the information.


Tags: , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

Final Update: Per a restoral announcement, this issue was resolved by 11:45 AM

Update 10:56 AM: According to Resideo, these notifications are the result of "catch-up" notifications from the outage earlier this week. As the queue for these old messages clears out, the erroneous messages should taper off. In the meantime, actual disarm photos may be delayed.

Original Post: We've had multiple reports this morning of Honeywell Lyric users who are receiving disarm photos from their panels every few minutes. Even users who don't have notifications enabled for disarm photos are being bombarded via the activity log. If you are affected, ignore disarm photo notifications for now.

Initially, it was only Lyric users who were reporting this issue, but now we've received reports from users of the Pro Series panels as well. It seems to be Push Notifications that are being affected. To disable Push Notifications for now, do the following:

  1. Log into Total Connect 2.0.
  2. Go to More > Settings > Notifications.
  3. Tap the toggle for Push Notifications so that it is disabled.

We'll provide more details as they become available.

Tags: , , , , , , , , ,

Comments


Posted By

Resideo sent out a notice on March 16 that the Lynx 3000 and the LynxTouch 7000, (aka the L3000 and the L7000) are discontinued. The Lynx Touch 5210 (L5210) is still being manufactured. This marks the end of an era for this product line as there is now no push-button panel option available.

Alarm Grid has already discontinued the L3000 panel because there are none in stock. There are some L7000 panels in inventory, so you can still purchase one of those panels, for now. However, as soon as stock is exhausted the L7000 will also be history. Speaking of history, the Lynx panel has had quite a run. The original Lynx panel was released in the 1990s and didn't even have a rechargeable battery.

The next iteration, the Lynx-R (R for Rechargeable), came along very soon after the Lynx (for obvious reasons). Then the LynxR-24, the LynxR-EN. There were so many different versions over the next 20 years. It used to be quite a job just figuring out which Lynx panel someone had when they needed support! It wasn't always a requirement that you know the version in order to solve the issue, but at times, the version information was crucial.

In the early 2010s the LynxTouch panels came along with the introduction of the LynxTouch L5000. That panel was missing some key features. It couldn't support any type of internet communication. It didn't have a back door into programming, so if you lost the Installer Code, well, that was too bad. So, pretty soon the L5100 was released with desirable features included that were missing in the L5000. We have an entire video devoted to discussing the versions of the LynxTouch panels, their differences, and how you can tell them apart.

Now, we're saying goodbye to the Lynx 3000, and the LynxTouch L7000. Since the first Lynx panel was introduced nearly 30 years ago, this is the first time there is no push-button version of a Lynx available. These panels have been very popular in apartments and dormitories, and I'm sure they will be missed. They are being replaced by the Honeywell Home PROA7, the Resideo PROA7C, the Honeywell Home PROA7PLUS, or the Resideo PROA7PLUSC.

The Lynx lineup is not completely gone, though. The Resideo LynxTouch 5210 (L5210) is still being manufactured. This panel occupies the middle ground between the L3000 and the L7000. It has a touchscreen, though it is rather small at 4.3 inches. It offers nearly all the same features as the L7000, albeit fewer of them. This means fewer zones, and fewer users in addition to the smaller screen, but also a smaller price tag. Check out this comparison between the L7000 and the L5210. This comparison includes the Lyric in addition to the L5210 and the L7000.

What do you think about this discontinuation? Given the fact that they have continued to update communicators for the L3000 to include the LTE products, I thought the L3000 was going to be around forever. Are you surprised at this news? Drop us a line in the comments below and let us know what you think. We enjoy a spirited conversation!

Tags: , , , , , , , , , , , , , , , , , ,

Comments


Posted By

I was able to speak with an industry insider familiar with the events at Resideo's data center on Sunday night into Monday evening. This person related to me that there was an HVAC failure at the primary data center. It was initially thought to be an easy fix, but that turned out to be false.

Things started to go wrong in Resideo's primary data center on Sunday night at around 7:00 PM Eastern Time. An HVAC failure allowed the temperature in the data center to climb to a dangerous level for the servers located there. The normal temperature is around 70℉ (21℃) but on Sunday it rose into the neighborhood of 130℉ (54.4℃). The servers are set to failsafe, so rather than continue running, and risk catastrophic damage, they began to shut down.

An automated system is in place which notifies engineering and other stakeholders when a serious event like this occurs. An HVAC technician responded. Initially, the technician believed this would be a quick and easy fix, so the decision was made not to switch to the secondary data center, which is located in the Chicago area. The switch takes a bit of time, somewhere around 20 minutes, and the thought was that it wouldn't be worthwhile at that point to make the switch.

However, the HVAC tech discovered that in order to implement a fix, he or she was going to require a part, which they didn't have and couldn't get at that time. So, at around 1:00 AM Eastern Time, the decision was made to switch things over to the secondary data center. By about 1:30 AM Eastern Time, the backup data center was in control.

At around daylight Monday morning the HVAC system in the primary data center had been fixed. Once it was fixed, there was a period of time where the temperature was coming down to an acceptable level. By approximately 11:00 AM Eastern Time, Resideo was ready to switch back to the primary data center. At this point, alarm signaling was back up and had been for some time. By around 2:00 PM AlarmNet360 was back up, and by about 6:00 PM Total Connect 2.0 was back online, though customers and our own testing show that it was somewhat sluggish at first.

This outage affected three (3) things. The most serious was alarm signaling. During the early hours of the outage, customer's systems were unable to send signals to the monitoring station, or to send notifications to the customers themselves. Total Connect 2.0, the customer-facing app and website for end-user remote control was also down. Lastly, AlarmNet360, the alarm dealer facing service used to create or cancel accounts and remotely troubleshoot issues was also affected. When things went wrong, the initial focus was on getting alarm signaling backup as quickly as possible. This was the focus when they initially switched to the Chicago area data center.

This is a fully redundant system, and it is tested regularly. According to my source, there were hourly notifications being sent to alarm dealers, but the database of email addresses for these notifications seems to be outdated. This is something they will address going forward. A root cause analysis will be completed in the coming days, and any processes or procedures that need to be updated will be dealt with at that time. The site at status.resideo.com doesn't have a section showing either AlarmNet360 or Total Connect 2.0 status. Hopefully, this is something that will change in the very near future as well. Finally, those dealers who did receive notification noted that the emails weren't flagged as containing particularly important information. This is also something that will be addressed in the future.

Tags: , , , , , , , , , , ,

Comments


Posted By

ConEd

As we've reported before, Alarm.com partners with electrical power providers all over the country in a demand response program called Give Back Get Back. In exchange for allowing your participating provider to adjust your thermostat slightly during peak demand hours, you receive a bonus.

According to Alarm.com, there are typically between six (6) and ten (10) peak events per summer season. Customers who opt into this program in their area will receive advance notice of any adjustment that is planned for their location. They have the ability to opt-out of a particular event, or the entire program, at any time. The most recent additions to the Give Back Get Back program are:

AEP PSO of Oklahoma

AEP PSO calls this program PSO's Power Hours program. In order to be eligible, you must be a PSO residential customer and the electric service must be in your name. You must have an eligible internet-connected smart thermostat controlling your central air conditioning. And you must agree to allow PSO to make brief, small adjustments to your thermostat during Peak Events on high demand days.

As an incentive, you will receive a $50 e-gift card per eligible device, once you have successfully enrolled that device into the program. This e-gift card will arrive within 60 days of your acceptance in the program. It will be sent to the email address used to register for the program so be sure you enter your email address correctly when signing up! At the end of the summer season, starting in 2022, you will receive a $25 e-gift card per participating thermostat. If you are enrolled in AEP PSO Oklahoma's Time-of-Day (TOD) rate option, you can also participate in the Power Hours Program.

Qualifying Thermostats:
Manufacturer Approved Thermostats
Alarm.com Radio Thermostat CT30, CT80, CT100; Trane ComfortLink Control; RCS Z-Wave Communicating Thermostat; GoControl Z-Wave Thermostat; Alarm.com Smart Thermostat; 2GIG Z-Wave Plus™ Battery Powered Thermostat; Trane Z-Wave Thermostat; Linear Thermostat
ecobee ecobee3; ecobee3 Lite; ecobee4; ecobee Smart; ecobee SmartThermostat with Voice Control
Emerson Sensi™ WIFI Programmable Thermostat; Sensi™ Touch WIFI Thermostat
Honeywell Home WIFI Smart Color Thermostat; WIFI 7-Day Programmable Thermostat; WIFI 9000 7-Day Programmable Thermostat; 9000 Smart Thermostat; 7-Day Programmable Smart Thermostat; VisionPro 8000 Smart Thermostat; Round Smart Thermostat; T5+ Smart Thermostat; T6 Pro Smart Thermostat; T9 Smart Thermostat, T10 Smart Thermostat
Lux LUX/GEO; LUX KONO
Google Nest Google Next Thermostat; Google Nest Learning Thermostat; Google Nest Thermostat E
Radio Thermostat Company of America Filtrete 3M-50; CT30; CT50; CT80

ConEd

By enrolling in ConEd's program in 2022, customers earn a chance to win a $5,000 prize. ConEd calls their program Power Savers. To be eligible to participate, you must be a resident of New York with an electric utility account, you must use your thermostat to control central air conditioning, and you must have installed an eligible thermostat. Note that the list of eligible thermostats is quite a bit smaller for ConEd.

Qualifying Thermostats:
Manufacturer Approved Thermostats
Alarm.com Radio Thermostat CT30, CT80, CT100; Trane ComfortLink Control; RCS Z-Wave Communicating Thermostat; GoControl Z-Wave Thermostat; Alarm.com Smart Thermostat; 2GIG Z-Wave Plus™ Battery Powered Thermostat; Trane Z-Wave Thermostat; Linear Thermostat
ecobee ecobee3; ecobee3 Lite; ecobee4; ecobee Smart; ecobee SmartThermostat with Voice Control
Lux LUX/GEO; LUX KONO
Radio Thermostat Company of America Filtrete 3M-50; CT30; CT50; CT80

AEP ApCo Virginia

With AEP ApCo, Appalachian Power Virginia, enrolled customers receive a $50 e-gift card upon enrollment and acceptance into the program. In addition, customers can earn up to $25 in e-gift cards at the end of the season ($5 for each summer month of participation from May - September).

To be eligible to enroll, you must be an Appalachian Power, VA residential electric customer, and the electrical service must be in your name. Once you install an eligible inter-connected smart thermostat for your central air conditioning system and sign up to allow Appalachian Power to make brief, small adjustments to your thermostat on days of high energy demand, you will receive your e-gift card. It should arrive within 60 days of being accepted into the program. The e-gift card will be sent to the email address used to register your thermostat, so be sure you enter your email address correctly, then be on the lookout for your gift card!

Qualifying Thermostats:
Manufacturer Approved Thermostats
Alarm.com Radio Thermostat CT30, CT80, CT100; Trane ComfortLink Control; RCS Z-Wave Communicating Thermostat; GoControl Z-Wave Thermostat; Alarm.com Smart Thermostat; 2GIG Z-Wave Plus™ Battery Powered Thermostat; Trane Z-Wave Thermostat; Linear Thermostat
ecobee ecobee3; ecobee3 Lite; ecobee4; ecobee Smart; ecobee SmartThermostat with Voice Control
Emerson Sensi™ WIFI Programmable Thermostat; Sensi™ Touch WIFI Thermostat
Honeywell Home WIFI Smart Color Thermostat; WIFI 7-Day Programmable Thermostat; WIFI 9000 7-Day Programmable Thermostat; 9000 Smart Thermostat; 7-Day Programmable Smart Thermostat; VisionPro 8000 Smart Thermostat; Round Smart Thermostat; T5+ Smart Thermostat; T6 Pro Smart Thermostat; T9 Smart Thermostat, T10 Smart Thermostat
Lux LUX/GEO; LUX KONO
Google Nest Google Next Thermostat; Google Nest Learning Thermostat; Google Nest Thermostat E
Radio Thermostat Company of America Filtrete 3M-50; CT30; CT50; CT80
Vivint Radio Thermostat CT100 with Vivint Go!Control Panel

If you're an Alarm Grid customer and you use an Alarm.com compatible panel with a Z-Wave or WIFI Smart Thermostat, you may be eligible to enroll in the same type of program in your area. To find out, you can go to enrollmythermostat.com, enter your Zip Code in the space supplied, and find out if your electrical, and in some cases gas company participates in the Give Back Get Back Program. As the old saying goes, every little bit helps!

Have a security-related topic you'd like to hear more about? Drop a comment in the space below and we'll research and post relevant information. What do you think about the Give Back Get Back Program? Are you in an area where you can take advantage of this feature? If not, contact your utilities provider, maybe they're unaware of this incentive program.

Tags: , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

Today, February 22, 2022 is the official date for the AT&T 3G Sunset. As we've mentioned before, there isn't a big switch that gets turned off and then, "Poof!" no more 3G. If you still have an AT&T 3G communicator, it may continue to work for a while, but there is no way to know how long.

If you're just becoming aware of the AT&T 3G Sunset because you have a security panel that you haven't been paying much attention to for a while, then you probably are seeing some type of error, and possibly hearing some annoying beeping. Some of the more common error messages are shown further down in this post. The thing to keep in mind is that your alarm panel wants to be sure that you know there's a problem. So, if you just press the touchscreen, or press any button on the keypad, that should stop the beeping, at least temporarily.

If you know the arming/disarming code for the system, enter it if prompted on a touchscreen panel, or if you're on a VISTA panel, just enter your 4-digit code and then press the OFF or 1 Key. This will acknowledge the trouble condition and stop the beeping on a more permanent basis, though in some cases, it may come back after a period of time. If you don't know a valid code for the system, then you will likely need to shut down your system by unplugging the transformer and the battery. If you're interested in putting your system into service keep reading to see how Alarm Grid is helping out in this situation.

If you find yourself in the unenviable position of needing to replace an AT&T 3G communicator, but you haven't done so yet, don't panic. The AT&T 3G network is vast and complex. It's not something that you can simply turn off. The process of sunsetting 3G equipment will take a bit of time. So, if after today your 3G communicator still works, you're one of the lucky ones. You've been given a slight reprieve. However, there is no way for us to know how long that reprieve will last, so decide what you're going to do, and do it now.

One ongoing problem that we've seen recently is supply chain issues. Maybe you've been trying to upgrade for the past six (6) months, but the communicator or system you need hasn't been available. Communicator manufacturers have been rolling out LTE Cat-M1 communicators in the absence of available components for standard LTE.

LTE Cat-M1 is the cellular network that was created for Internet-of-Things (IoT) use. It has lower power consumption, better range, and the modems used for it have a smaller form factor. The trade-off is lower bandwidth. However, the amount of data being transmitted by alarm communicators is very low compared to voice and data used for a traditional phone, so the difference in bandwidth isn't noticeable. Happily, the components to make LTE Cat-M1 communicators appears to be readily available, so those communicators have been coming into stock in the past months and continue to become available.

Some of the available AlarmNet LTE Cat-M1 communicators are listed below. These communicators are all compatible with the VISTA panels. The LTEM-PA and LTEM-PV are also compatible with the DSC PC1616, DSC PC1832, and DSC PC1864 and the Interlogix NX Series panels. For the Interlogix NX Series, the PRODCM is also required:

  • LTEM-PA - Dual-path IP and AT&T LTE Cat-M1 communicator with the ability to add a traditional LTE communicator if needed. First communicator to allow non-Honeywell panels to use Total Connect 2.0.
  • LTEM-PV - Dual-path IP and Verizon LTE Cat-M1 communicator with the ability to add a traditional LTE communicator if needed. Along with the LTEM-PA can allow non-Honeywell panels to use Total Connect 2.0.
  • LTEM-XA - AT&T LTE Cat-M1 Communicator for VISTA Panels.
  • LTEMXA-TC2 - AT&T LTE Cat-M1 Communicator for VISTA Panels. Includes upgrade chips for VISTA-15P and VISTA-20P panels, allowing them to support Total Connect 2.0.
  • LTEM-XV - Verizon LTE Cat-M1 Communicator for VISTA Panels.
  • LTEMXV-TC2 - Verizon LTE Cat-M1 Communicator for VISTA Panels. Includes upgrade chips for VISTA-15P and VISTA-20P panels, allowing them to support Total Connect 2.0.
  • LTEM-IA -COMING SOON - AT&T LTE Cat-M1 Communicator with RJ45 Port for Ethernet. Currently in Beta.
  • LTEM-PIA - AT&T LTE Cat-M1 Communicator with RJ45 Ethernet port. Listed for UL-985 Household Fire.
  • LTEM-PIV - Verizon LTE Cat-M1 Communicator with RJ45 Ethernet port. Listed for UL-985 Household Fire.

Some of the available Alarm.com LTE Cat-M1 communicators are listed below. Compatibility is listed with each communicator:

  • Alarm.com ADC-SEM210-PS-AT-M - COMING SOON - Dual-path AT&T LTE Cat-M1 and ethernet capable communicator for use with legacy DSC Power Series panels (PC1616, PC1832, PC1864).
  • Alarm.com ADC-SEM210-PS-VZ-M - COMING SOON. - Dual-path Verizon LTE Cat-M1 and ethernet capable communicator for use with legacy DSC Power Series panels (PC1616, PC1832, PC1864).
  • Alarm.com ADC-SEM300-VT-AT-M - COMING SOON. - Dual-path AT&T LTE Cat-M1 and ethernet capable communicator for use with Honeywell VISTA (non-polling loop) panels (VISTA-10P, VISTA-15P, VISTA-20P, VISTA-21iP manufactured in 2005 or later).
  • Alarm.com ADC-SEM300-VT-VZ-M - Dual-path Verizon LTE Cat-M1 and ethernet capable communicator for use with Honeywell VISTA (non-polling loop) panels (VISTA-10P, VISTA-15P, VISTA-20P, VISTA-21iP manufactured in 2005 or later).

Panel Cellular Communicator Trouble Condition Messages

If you are affected immediately by the AT&T 3G shutdown, you may see one of these error messages on your system:

  • Check 103 ####: - You may see this on a non-polling VISTA panel, such as the VISTA-20P, but only if you have an Alpha Keypad like a 6160. The #### will be a 4-digit number. It may be 4005, which indicates that the communicator has lost connection with AlarmNet. The exact 4-digit code will depend on whether there are any other trouble conditions existing on the communicator at the time the message is displayed.
    *If you have a VISTA panel, choose from any of the communicators listed above for VISTA panels. The VISTA-21IPLTE can use the LTE-21V. The only way to update an original VISTA-21iP is to add an external communicator and disable the internal one. The prior link is an FAQ on how to do just that. The same rule about possibly downgrading to an IP only plan mentioned under the bF message applies here too.
  • bF, or it may look like 6F: - This is supposed to be a bF, which stands for Backup Failure, as in backup communicator. This message means the same thing as Check 103, but will be displayed on a non-alpha keypad like a 6150. If this is the only type of keypad you have, then this is all the information the panel and the communicator can give you. If you get this message after 02/22/22 and your AT&T 3G Communicator has been fine until then, you're not one of the lucky ones. You should look to upgrade your communicator ASAP. *Or, if you have a dual-path communicator and an IP connection is available near it, you could downgrade to an IP only plan for now, and upgrade to LTE at a later time. Just bear in mind, if you go IP only, when the internet is out, your panel's ability to communicate is out. This is usually the case during power outages. The above rule about upgrading the communicator under the Check 103 message also applies here.
  • Fault 103: - This may also show as a Check 103, then display as a Fault 103 after you silence the panel. This is what you see on the Honeywell L3000 panels when there is a problem with the communicator. Losing connection due to the 3G Sunset would cause this error code. There is not a good IP only option for the L3000 currently available. You can use a 7847-I, but it is a messy installation. You can also use the 7847I-L, if you can find one, they are discontinued.
  • 103 Comm. Trouble: - The Lynx Touch Panels will display something along these lines. The icon and message may differ slightly, but the gist is the same. This is what you'll see on these panels if you're affected by the AT&T 3G shut down.
    • Honeywell LTE-L57A: - AT&T LTE Communicator for Lynx Touch panels. Important! There may be panel firmware revision restrictions with your panel and either of these communicators. Read the product description very carefully to be sure your panel is on the correct version for the communicator you choose. If you need to update the panel, you can do so with the Honeywell LYNXTOUCH-MSD Firmware Update Tool. It is compatible with the L5200, L5210, and L7000.
    • Honeywell LTE-L57V: - Verizon LTE communicator for the Lynx Touch panels. See the Important note above about panel firmware version limitations.
  • ⚠ 950 Comm. Trouble: This is the message displayed on a Lyric Controller if it has a cellular communication path, and it loses contact with AlarmNet on that path. This is what you will see if the AT&T 3G shutdown has caused your communicator to go down. There may be other messages in the status bar at the top of the screen as well, having to do with Comm Failure and potentially other conditions, depending on what's happening with your panel at the time.
    • Honeywell LYRICLTE-A - AT&T LTE Communicator for Lyric. Firmware Revision v01.03.06548.482 or higher required!
    • Honeywell LYRICLTE-V - Verizon LTE Communicator for Lyric. Firmware Revision 1.09 (aka MR9) or higher required!

  • Check 8##, ####: - You may see this message on a VISTA-128 or VISTA-250 panel. Devices connected to the keypad bus can be supervised for a connection to the panel, and for a tamper condition where applicable. The AT&T 3G Communicator can also be supervised for communicator troubles, such as a loss of connection to AlarmNet. If supervision is enabled (and it is not enabled by default) then when the 3G Sunset affects the communicator, the panel will display a Check or Trouble (based on programming) 8 + the 2-digit number of the address. So, if the communicator is assigned to address 03, and supervision is enabled, it will display as a Check or Trouble on Zone 803 plus the 4-digit communicator status code associated with the condition when you have the proper keypad to display it. If the only problem is a loss of network connection, then the 4-digit code should be 4005. Supervision is enabled by enabling the associated 800-zone with a trouble zone type, such as 05, Trouble by Day/Alarm by Night.
  • 2GIG GC2 and GC2e Displays Trouble Icon and beeps 6 Times per minute until the trouble condition is acknowledged: This is the behavior of the 2GIG GC2e and presumable the 2GIG GC2 as well. The Security Screen will show a Yellow button with an exclamation mark and a number. When you press the button, it will take you to the Trouble Display screen where you can scroll through the trouble conditions, and you may click on the communicator trouble then press OK. This will stop any beeping, but the display will continue to show trouble until the condition is cleared. In the case of the AT&T 3G Sunset, this means upgrading the communicator.


    • 2GIG LTEA-A-GC2: - Alarm.com compatible AT&T LTE Communicator for 2GIG GC2 and 2GIG GC2e. Important! Be sure to check for any panel firmware version requirements associated with either of these LTE communicators for the 2GIG GC2 and GC2e panels.
    • 2GIG LTEV1-A-GC2: - Alarm.com compatible Verizon LTE Communicator for 2GIG GC2 and 2GIG GC2e.
  • 2GIG GC3 and GC3e Message LED is lit and the panel chimes at ten-second intervals until the condition is acknowledged: The behavior for the cellular communicator losing connection to the AT&T 3G network on a 2GIG GC3 or GC3e depends somewhat on panel programming. In Q30, you set the amount of time that is allowed to elapse with no communication to the server before a trouble condition is indicated. The default is 30 minutes. A 0 in this field disables the supervision feature. The maximum entry is 255 minutes. Q31 also determines whether the radio network failure causes a trouble condition on the panel. This is enabled by default, but if disabled, you will have no visible indication if you are affected by the AT&T 3G sunset. Q32 is radio network failure reports. This is enabled by default and determines whether the panel reports the radio failure to the monitoring station (assuming it is able to do so with the radio down, the panel would need to be utilizing the WIFI communication path for this to be possible.)
    • 2GIG LTEA-A-GC3: AT&T LTE Communicator for the 2GIG GC3 and GC3e panels. The panel must have Firmware Version 3.2.3 or higher to support this communicator.
    • 2GIG LTEV1-A-GC3: Verizon LTE Communicator for the 2GIG GC3 and GC3e panels. The GC3 or GC3e must have Firmware Version 3.1.3 or higher to support this communicator.

Alarm Grid Is Here To Help!

If you're a current Alarm Grid customer and you have purchased an LTE communicator, but haven't switched over to it yet, please send an email to support@alarmgrid.com. In the subject line, be sure to put "I Need an LTE Upgrade". We'll reach out with further instructions and either a link to schedule your upgrade, or information as to what we need to begin your upgrade. Lyric and Lynx Touch users may be able to get upgraded with no appointment, where a VISTA user may require an appointment as those communicator swaps are a little more intricate.

If you purchase an LTE communicator or an upgrade kit from Alarm Grid, we will credit your monitoring account in the amount of the communicator or upgrade kit. If you purchase more than $150 in product, we'll also offer you free ground shipping, so if you've been thinking of adding a doorbell camera, or other products to your system, now may be a good time. The cost of products not associated with the communicator or system and communicator upgrade will not count toward free monitoring though.

If you have the ability to switch to an ethernet or WIFI connection only, you can choose to do that and your monthly monitoring fee will go down. You can purchase an IP or WIFI communicator strictly for that purpose. You may have that option with your existing panel and you just aren't using it, or maybe you were using dual-path monitoring, but now the cellular portion of your 3G communicator has stopped working. Whatever the case, if your communicator or panel supports the option for an IP-only connection, we will be glad to downgrade your service plan permanently, or until you can get the LTE upgrade. But be aware, Alarm.com customers do not have an option for IP-only monitoring.

If you're not a current Alarm Grid customer, never fear, you can get exactly the same deal as existing customers. If you purchase an LTE communicator from us or a kit with a panel and LTE communicator and you then sign up for monitoring with us, we'll give you credit toward free monitoring in the amount of the purchase for the communicator or communicator and panel. Once again, purchases over $150 will have free ground shipping, but any sensors or other devices that you purchase will not count toward free monitoring.

If you have any questions, feel free to reach out to us at support@alarmgrid.com. Our support hours are Monday - Friday from 9:00 am - 8:00 pm Eastern. We will help in any way that we can to get you through this transition. Your safety and peace of mind is our top priority.

Tags: , , , , , , , , , , , , , , ,

Comments


Posted By

We told you in 2020 how the Total Connect 2.0 app for Android could support Google Assistant voice commands. This feature allowed you to use your voice to control your system, but only through your phone. Now, the ProSeries panels, including the PROA7PLUS, can fully support Google Assistant.

What this meant back then was that there was nothing to download. Once the feature was enabled on your phone, a blue microphone icon would appear at the bottom of the Total Connect 2.0 app screen. When you pressed it, you could use your voice to check system status, and to arm or disarm the system. Now, with the latest Total Connect 2.0 release, you can actually set up TC2 within Google Home, and control your system from any Google Home capable device you have connected to your account.

Another improvement is the fact that this functionality is now available to both Android and iOS users. On either platform, make sure you have the Google Home app and then follow the steps to configure the Total Connect 2.0 skill within it.

Below is the Google Home App as seen in the Apple App Store:


The ProSeries panels include the Honeywell Home PROA7 and Honeywell Home PROA7PLUS and the Resideo PROA7C and Resideo PROA7PLUSC. Currently, these are the only Total Connect 2.0 compatible panels that support the improved Google integration. If you have one of the ProSeries panels, coupled with a Total Connect 2.0 account and you would like to take advantage of voice commands through Google Assistant, follow these steps:

  1. Open the Google Home App, then click the [Plus (+)] Icon at the top left of the main screen.
  2. Select, [Set up Device].
  3. Select [Works with Google].
  4. Search for [Total Connect] then select it.
  5. Use your Total Connect 2.0 login credentials to log into TC2 from the skill.
  6. Read the User Agreement and if you agree, press [Allow].
  7. Be sure the Security System icon is selected, then press [Connect].
  8. Click the [Pencil Icon] to assign the system to a room, then choose which room you'd like to add it to.
  9. Hit the [Back button] repeatedly until you reach the Home screen.
  10. You should now be able to query Google for system status, as well as arm the system to Away, Stay, or Night and Disarm the system using Google Assistant.

Important Update: We now have a full FAQ with a walk-through on how to set up the Google Home feature. This FAQ is applicable whether you're setting Google Home up using an Android or an iOS device running the Google Home App.

Voice control of automation devices is not yet available unless the automation is achieved through a scene tied to system arming or disarming. For example, if you have a scene that turns on the porch light when the system is armed to Away, and you use the Google Assistant to arm in this mode, then the porch light will come on once the system is armed.

Total Connect 2.0 also supports integration with Amazon Alexa, and has for a while now. The configuration is very similar between the two services. One difference between them is that Amazon Alexa is compatible with more different panel types. Most of the Honeywell Wireless All-in-One panels support it. This means that in addition to the ProSeries panels, the Lyric, Lynx, and even the VISTA panels all support being used with Amazon Alexa. As long as the panel is tied to a Total Connect 2.0 account.

To integrate Total Connect 2.0 with Amazon Alexa for voice control of any of the above panels, follow these steps:

  1. Open the Alexa App and search for the Total Connect 2.0 skill.
  2. Click [Enable]
  3. You will be prompted to enter your Total Connect 2.0 login credentials. Enter them, then hit [Login]
  4. You will see a User Agreement, read through it, and if you agree click [Allow].
  5. Make sure the Security System icon is selected, then click [Connect].
  6. A screen should appear showing "Total Connect 2.0 has been successfully linked".

Once the above steps have been completed, log into the Total Connect 2.0 app and go to the Profile Page. Under the Access section, be sure that your user code has been saved and synched with the panel. If this isn't done, Amazon Alexa won't function properly. In the past, we've made FAQs for integrating some different panels with Amazon Alexa. You can find links to those FAQs below:

How Do I Connect My Lyric Alarm System to Alexa?

How Do I Connect My VISTA-21iP to Alexa?

Resideo Official Instruction Sheet on Integration

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments