Product Announcements Posts

Posted By

2GIG strongly recommends that all Edge panels be updated to the latest firmware version, 3.1.1.016. This firmware has a number of new features and bug fixes. New features include Z-Wave siren support and updated remote keypad features. For a full list of updates, read the release notes.


The 2GIG Edge supports a WIFI connection in addition to the AT&T or Verizon cellular communicator that comes built-in. For any Alarm.com panel that is connected to WIFI, OTA (Over the Air) firmware updates that are downloaded to the panel using WIFI are free. However, for those panels that don't have access to WIFI, a firmware update that is sent to the panel via cellular data usually incurs a small fee. Alarm Grid passes this fee on to our customers with no markup, when it is assessed.

But, for a limited time, Alarm.com is offering to update the 2GIG Edge panel automatically with no fees assessed, even when the firmware has to be downloaded via cellular data. That's how important 2GIG and Alarm.com feel this update is. Beginning on Monday, September 12, 2022, Alarm.com will push the latest firmware to all monitored 2GIG Edge panels.

These automatic updates will take place only during daylight hours, and only when the alarm panel is disarmed. When the firmware update is complete, the alarm panel will reboot. This is a normal part of the update process. Additionally, if there are any remote keypads associated with the panel, they will also be updated once the main panel has completed its update. Alarm.com expects the process of updating all 2GIG Edge panels to be completed by the end of October 2022.

If you'd like to go ahead and update your panel immediately, you can access the necessary files for the update on our 2GIG Edge Firmware Update Page. Instructions for updating the 2GIG Edge can be found in this helpful FAQ. Otherwise, do nothing and your panel will be automatically updated OTA by Alarm.com at no charge, in the near future.

Tags: , , , , , , , , , , , , , , , , , , , , , , , ,

0 Comments


Posted By

Alarm panel manufacturers routinely offer panel firmware updates. This allows them to add features and correct issues. However, most DIY users don't have access to the restricted portion of the company's site where these files are housed. Alarm Grid offers the latest firmware file downloads.

Most alarm panels can be updated Over-the-Air (OTA) using either Alarm.com or AlarmNet360. AlarmNet never charges anything for these updates, and Alarm.com also offers them for free, unless they have to be sent to the panel using cellular data. In that case, the update will incur a small fee, depending on the size and number of updates that need to be sent.

Qolsys panels will not perform an OTA update unless the panel is connected to WIFI. If you have one of these panels installed in a location where WIFI is not available, then the only option is to either update using a cell phone as a WIFI Hotspot, or download the firmware files, and then install them via either Micro SD Card (IQ2/IQ2+) or Access Point (IQ4).

Honeywell L5200, L5210, and L7000

Honeywell used to offer free firmware updates for the LynxTouch panels that they pushed remotely using AlarmNet360. It was a messy process, AlarmNet tech support was required to request these updates individually, per account. So, sometime after the introduction of the Lyric panel, they stopped this practice. The Lyric can only be firmware updated using AlarmNet360, but the update can be requested by the dealer, and now, the customer can also request the firmware update via the panel. When Honeywell, now Resideo, ceased offering OTA updates for the LynxTouch panels, they released the Honeywell LYNXTOUCH-MSD Firmware Update Tool. This tool can be used to update the L5200, L5210, or L7000 panels.

When an L5200 is updated to the latest version, it becomes an L5210 internally, though there are certain physical traits of the L5200 that won't change, like the screen size. Depending on when you purchased the LYNXTOUCH-MSD tool, it may come with the latest firmware version already on the SD Card (it comes with both L5210 and L7000 firmware already loaded). However, if you purchased your update tool when they were first released, it will have an older firmware version on it, and you will need to download the newest firmware to the SD Card and update the panel again to get the most current version. The update files are housed on the Resideo website in the password-protected portion of MyWebTech, so we offer the files for download from our site:

2GIG Go!Control 2 (GC2) or 2GIG GC2e

The 2GIG GC2 and 2GIG GC2e have a couple of different methods for updating the firmware. There is the 2GIG UPDV Easy Updater Tool and the 2GIG UPCBL2 Firmware Update Cable. The updater tool is geared more toward a professional installer who will be updating multiple different panels over the course of years. It comes with a version of either the 2GIG GC2 or GC2e firmware loaded but the tool itself will then have to be updated when newer firmware is released. The files to load are available from our site and are linked below.

The updater cable is the method of update most DIY users choose to use. It requires that the user have a windows computer available. The cable is a fixed length, so the computer that will be used needs to be near the alarm panel in order to perform the update. Ideally, a laptop is used. Instructions for using the updater cable to load the latest firmware onto a 2GIG GC2 or 2GIG GC2e can be found here. Instructions for loading new firmware onto the 2GIG UPDV Easy Updater Tool can be found here. Instructions for using the updater tool to update a 2GIG GC2 or GC2e panel once it has the latest file loaded can be found here.

The 2GIG GC2 and 2GIG GC2e firmware pages are linked below. Each page has both Updater Tool and Updater Cable files:

2GIG GC3 and 2GIG GC3e

The 2GIG GC3 and 2GIG GC3e technically use the same firmware. The 2GIG GC3e was released at firmware version 3.2.1, so any GC3e panel will have at least this version of firmware already installed. Alarm Grid offers firmware versions 3.0.1 up through 3.2.4.6725 on our 2GIG GC3 Firmware Update Page. On our 2GIG GC3e Firmware Update Page, we offer 3.2.3.6713 up through the current version which, at the time of this writing, is 3.2.6.6770.

The 2GIG GC3 and 2GIG GC3e are both much easier to update than the 2GIG GC2 or GC2e. Both 2GIG GC3 versions offer WIFI, which makes OTA updates simple, as well as free. For systems that need it, an OTA update can be pushed from Alarm.com via cellular for a nominal fee. Again, Alarm Grid offers this type of upgrade to our customers at our cost, with no markup. If WIFI is not available at the panel, and a user doesn't want to pay for an OTA update, we offer the upgrade files from our site. This FAQ provides a walkthrough on how to perform the update using the files from our site. Instructions for performing the update are also listed on the page along with the firmware files.

2GIG Edge

The 2GIG Edge updates in the same way as the 2GIG GC3 and GC3e. It has a USB port located on the top of the panel. Once the firmware update file has been loaded onto the root directory of a USB drive, the drive is inserted into the port on the panel's top and the panel prompts the user to update. For full instructions on updating a 2GIG Edge, check out this FAQ.

Qolsys IQ Panel 2 and IQ Panel 2 Plus

The IQ Panel 2 and IQ Panel 2 Plus also use the same firmware version. The difference between the two panels is hardware. The IQ Panel 2 does not support PowerG, and the IQ Panel 2 Plus does. As noted above, Qolsys panels will not download firmware updates via cellular data, so the options are to connect the panel to WIFI, temporarily connect the panel to a Hotspot on a cellular phone, or update locally using a Micro SD Card. The step-by-step instructions for loading the firmware from an SD Card are shown on the firmware update page.

Qolsys IQ Panel 4

The Qolsys IQ Panel 4, like the previous IQ Panels, will not download firmware updates via cellular data. However, unlike the IQ Panel 2 or IQ Panel 2 Plus, the IQ Panel 4 does not have a Micro SD Card slot. Instead, if WIFI is not accessible by the panel, either directly or via a cell phone Hotspot, then the firmware update files have to be downloaded to a phone or tablet, then the phone or tablet must be connected to the IQ Panel 4 Access Point, and the files then loaded to the panel from the phone or tablet. Instructions for updating using the Access Point are available on the firmware download page.

Above are links to all the different panel firmware pages we offer here on the Alarm Grid site. In addition to alarm panel firmware, we also offer some firmware pages for the Honeywell Home TUXEDOW or Resideo TUXEDOWC touchscreen keypads as well as the older Tuxedo Touch firmware. We don't have a page for the older 6280 touchscreen keypads, but if you need access to that firmware, send an email to support@alarmgrid.com letting us know what you need and we can get you access to it.

As mentioned above, the Lyric panel can only be updated via AlarmNet360 and in order to update the firmware, the panel has to be actively monitored. The same is true of the newer Honeywell Home and Resideo ProSeries panels (PROA7, PROA7PLUS, PROA7C, and PROA7PLUSC). These panels must be actively monitored and registered with AlarmNet360 before an update can be applied to them.



Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

0 Comments


Posted By

Johnson Controls released a Technical Advisory Bulletin on Monday noting that some PowerSeries Neo, Pro LTE, and Internet Dual-Path Communicators have labeling errors. The serial number on the box appears to be incorrect. Comms built between August 15, 2021, and July 29, 2022, are affected.

The model numbers affected are the DSC TL880LECVZ, TL880LECAT, TL880LEBAT, TL880LEBTL, and TL880LECTL. This is a labeling error only and does not affect the signal transmitting, or Alarm.com remote control capabilities of these communicators in any way. The mixup seems to be with the name on the label on the product, and the serial number on the label on the box.

The model name listed on the label of the product is incorrect, while the serial number listed on this label is accurate. The model name listed on the sticker for the box is correct, but the serial number listed on the box is incorrect. So, be sure when registering one of these units that you use the serial number from the sticker for the product and not the one from the box.

The following products, built during the listed date range, are affected:

Model Name Production Dates
TL880LECVZ January 4, 2022 - July 29, 2022
TL880LECAT July 5, 2022 - July 29, 2022
TL880LEBAT November 15, 2021 - July 29, 2022
TL880LEBTL November 15, 2021 - July 29, 2022
TL880LECTL June 6, 2022 - July 29, 2022

Beginning July 29, 2022, new, updated and correct labels should be placed on these products. Remember, the performance of communicators that were manufactured during this timeframe is not compromised. This is only a labeling error, so as long as the serial number taken from the sticker affixed to the product itself, or the IMEI number from the printed circuit board is used everything should work as intended. DSC offers a handy Date Code Lookup tool at this site. You can find information on looking up a date code for any DSC product on that page.

The fact that this issue wasn't discovered sooner seems to indicate that this is a very minor issue. What do you think about this announcement? Do you often use these communicators? Have you run across this issue? Leave us a comment below and tell us what you think. We always enjoy hearing from our readers. That's all for today, until we meet again, stay safe!

Tags: , , , , , , , , , , , , , , ,

0 Comments


Posted By

Resideo announced last week that due to a required component becoming obsolete, they are forced to discontinue the popular 5800FLOOD sensor. There is still some available stock, so Alarm Grid has not yet discontinued it, but once all stock has been exhausted, the 5800FLOOD is gone for good.

The 5800FLOOD is popular because unlike the 5821, it doesn't require that a water probe be added to the sensor. Water detection is built-in, and configuration is easy. Another benefit of the 5800FLOOD is that it will alert for flooding more quickly than the 5821. The prongs of the 5800FLOOD need only be in contact with water for about 25 seconds before a signal is sent to the alarm panel. The 5821 flood probe must be in contact with water for about three (3) minutes before sending a signal.

In addition to flood sensing, the 5800FLOOD also monitors for extreme cold and/or hot temperatures locally. This is done using a temperature sensor that is built into the 5800FLOOD. For cold temperature sensing, if the ambient temperature drops below 45℉ (7.2℃) for more than 15 minutes, an alert is sent using Loop 1. For high-temperature sensing, if the temperature rises above 95℉ (35℃) for more than 15 minutes, then an alert is sent using Loop 2. The flood sensor transmits using Loop 3.

Now that the 5800FLOOD is being discontinued, the Resideo and Honeywell Home 5821 is the recommended replacement. One drawback to the 5821 is that it requires a remote probe be added for flood sensing, and for freeze sensing. However, only one (1) remote probe can be used per transmitter, so if you need to monitor for both flood and freeze, two (2) 5821s are required.

The 5821 supports the following functions:

Loop Number Sensing Capability Description
Loop 1 Ambient Low Temperature Sensing <45℉ (7.2℃) >10 Minutes sends alert
Loop 2 - Local Ambient Warm/Hot Temperature Sensing >75℉ (23.8℃) >10 Minutes sends alert; >95℉ (35℃) >10 minutes sends alert. Disabled when any remote probe is used!
Loop 2 - Remote Using T280R or TS300R Remote Probe Freeze Sensing >10℉ (-12.2℃) for 30 minutes; Refrigerator Sensing >42℉ (5.5℃) for 30 minutes. Can't be used if the Flood Probe is used.
Loop 3 - Remote Uses FP280 or 470PB Remote Probe Flood Sensing - Signals when the probe's terminals have been in contact with at least 1/4" of water for > 3 Minutes. Can't be used if the Temp Probe is used.

For flood sensing, we recommend using the FP280 as it includes wiring, and the required resistor is already in place. With the 470PB, the user is responsible for providing their own wire and must add the 2.2 MΩ resistor themselves. In all cases, wiring between the 5821 and whichever remote probe is used should be made as short as possible, and should not exceed 96" (243cm). Be sure to read the full Install Guide for the 5821 for all of its various quirks.

Supply chain shortages claim another victim in the 5800FLOOD. It seems like only yesterday that we were excitedly telling you about it. What are your thoughts on the demise of this "New and Improved" environmental sensor? Leave us a note in the comments, as we always love hearing from our readers.

Tags: , , , , , , , , , , , , , , , , , , ,

2 Comments


Posted By

Resideo and Honeywell Home, formerly Honeywell, released an announcement last week that they will change their date code format from a YDDD (Year, Day of the year) format, to use YYWW (Year, Week of the year). This is being done, ostensibly, to simplify the decoding of date codes for users.

Product date codes are important for determining whether a product is still under warranty, as well as whether it may be affected by a particular anomaly that may have occurred because of an issue in the manufacturing process. For Carbon Monoxide detectors, which always have a finite useful life, the manufacturing date code is important to help determine when a CO detector needs to be replaced, particularly if the detector doesn't include a feature to warn a user when its useful life is coming to an end. For all these reasons, it's important to be able to decode a date code.

Going all the way back to the Ademco days, Resideo products have used a date code where a letter signified the Year of manufacture, and a 3-digit number signified the day of manufacture. For example, 2022 has been signified by the letter F, so a date code of F159 would indicate a product was manufactured on the 159th day of 2022, or June 8. Calendars can be downloaded from the internet with all the days of the year enumerated.

Of course, this date code scheme has advantages and disadvantages. The letter used to signify each year can seem somewhat arbitrary, and at some point, letters must begin to be repeated. So, with a very long-lived product line, there could be some confusion as to whether a particular letter indicates the older or newer iteration of that letter for that product. The advantage of this format is that you know exactly which day a product was manufactured, and exactly which day it was packaged (packaging has its own date code, which follows the same format). This information can be helpful when determining a manufacturing issue.

Starting this month, June 2022, Resideo will standardize on a new Date Code format. In this format, containing four (4) digits, the first two (2) digits will indicate the year of manufacture, and the last two (2) digits will indicate the week of that year (YYWW). This will simplify things, as no one will have to look up or figure out which year goes with which letter, but it also doesn't supply quite as detailed an accounting of when a product was manufactured or packaged as the old format did. Packaging date codes will also be making the switch.

Below are some examples of the new Date Code, in these examples, the Date Codes are all 2223, indicating they were manufactured the 23rd week of 2022:


Tags: , , , , , , ,

0 Comments


Posted By

Effective in August of 2022, Alarm.com is ending sales of Alarm.Com Image Sensors (ADC-IS-220-GC and ADC-IS-300-LP). Alarm Grid has already discontinued these sensors due to the fact that they are in short supply, and no more of them will be produced. Only the Honeywell Home PROINDMV remains.

The 2GIG IMAGE3:


There was some overlap between the Alarm.com Image Sensor models, and the 2GIG and Qolsys Image Sensor models. I have confirmed with Alarm.com that the 2GIG and Qolsys models are also discontinued as of August, 2022. Currently, the only Image Sensors being offered by Alarm Grid are the DSC PowerG and Honeywell Home PROINDMV models which are discussed in more detail below.

Image sensors were a great idea that never really took off. The original image sensors, first offered by 2GIG and Alarm.com, did not have particularly good resolution or picture quality, which is probably one reason they weren't widely adopted by the DIY crowd. By the time the 2nd generation of these sensors came around, people were prepared to simply go with full-on video monitoring or to avoid capturing images altogether.

Both the second and third-generation image sensors that were offered by 2GIG, Qolsys, and Alarm.com had very good image quality. Combine that with Alarm Grid's policy of offering monitoring for image sensors without an additional price markup, and the image sensor was a viable alternative to the use of video cameras. An Alarm.com user could log into their account and perform a "peek-in", meaning they could request that a particular image sensor grab a picture of whatever it was able to see at that moment, and the image (actually two (2) images) would then be uploaded to the customer's alarm.com account for viewing. The sensor could also take images upon sensing motion after a particular period of inactivity, or upon an alarm. For full details on image sensor features and operation, check out this prior post.

DSC offers a couple of PowerG PIR Cameras that will work with the Qolsys IQ Panel 2 and IQ Panel 4 in addition to the DSC PowerSeries Neo panels with a PowerG Transceiver added. These are the DSC PG9934P, Indoor PIR Camera, and the DSC PG9944, Outdoor PIR Camera. These sensors work like any other PowerG Sensor with the Qolsys Panels. They can only capture images when the system is armed and the image sensor is active (not bypassed). They send their images to the panel, and then the first image is uploaded to Alarm.com. A total of ten (10) images are taken, and these images are stitched together by the panel into a sort of stop-motion video where each image can also be viewed individually. This is done via the panel screen itself. When used with the PowerSeries Neo panels, the DSC PIR Cameras can be used for Visual Verification only, they do NOT work like a regular image sensor with Alarm.com.

DSC PG9934P, Indoor Image Sensor:

DSC PG9944, Outdoor Image Sensor:


The Honeywell Home PROINDMV is a wireless PIR motion sensor with a camera built-in, just like the 2GIG, Qolsys, and Alarm.com image sensors were. The PROINDMV is currently only supported on the Resideo PROA7PLUSC, and Honeywell Home PROA7PLUS panels. There is no "peek-in" option for these image sensors. They can only capture images when they sense motion while the system is armed in Away mode. Images or videos are captured and uploaded to Total Connect 2.0 for viewing. The user can choose to receive either a still image or a 10-second video clip. You can read their full details of operation in our previous post.

Honeywell Home PROINDMV:


It seems like the era of the image sensor may be coming to a close, at least for now. Who knows, once we're through the global chip shortage, and the availability of components is back to normal, perhaps the humble image sensor will experience a revival. If so, DIYers may want to consider giving these sensors a try. They really are an excellent idea. They can be used for alarm verification in this age of increasing police resistance to alarm response, and they are cheaper, both initially and on an ongoing month-to-month basis, than video cameras.


Tags: , , , , , , , , , , , , , , , , , , , , , ,

0 Comments


Posted By

Resideo has been investigating an issue with a very small number of communicators. The LTE-CFV, HWF2V-COM, LTE-IV, LTE-L3V, and VISTA-21IPLTE with LTE-21V. In a few cases, starting on March 19, 2022, the Verizon LTE SIM has become locked, causing a comm failure, or secondary path failure.


A device with this issue will show the following symptoms: Locally at the device, the LEDs will flash regularly at a rate of two times per second (see video above). Through AlarmNet360, the affected devices will have checked in normally for the period leading up to March 19, 2022. Then beginning on that date, or on a subsequent date through March 28, 2022, a comm failure will be indicated. Once the comm fail indication appears, it will not clear, so if you've had a comm failure during this time that has restored, then your communication failure is not being caused by this issue.

In addition to the above evidence of an issue, the alarm panel that the communicator is connected to will have a trouble indication displayed. This may come in the form of a Check 103, or a bF on VISTA-20P and similar panels, and also the L3000 panel. For the L3000 panel, the bF will only show on an RF keypad, such as the 5828 or 5828V, the panel itself will show Check or Fault 103. To silence any trouble beeping, enter a disarm command at any panel keypad. These trouble messages can be caused by other things, not just this issue, so if you see one of these error messages and think you may be affected, be sure to contact your alarm dealer for further assistance.

Bear in mind that only the communicators listed above are affected, and that these are all Verizon SIM Cards. If you have an AT&T Communicator, you needn't worry about this issue. Also, for those who have a dual-path communicator with Ethernet connected, you will not necessarily see a Communication Failure message. Instead you will be notified of a Secondary Path Failure. Again, if you are affected by this issue, once the failure occurs, it will not restore. So if you've received a Secondary Path Failure that has since restored, then you experienced a separate issue.

Again, if you feel that you have been affected by this issue, contact your alarm dealer. They can confirm if you are affected and will be able to assist you in receiving a replacement SIM. Alarm Grid customers who are affected have already been contacted and replacement SIMs are on the way. If any further information becomes available, we'll update this post with further details.

Tags: , , , , , , , , , , , , , , ,

0 Comments


Posted By

Alarm Grid has long steered customers away from Schlage locks due to support issues. In our experience, we have spent time troubleshooting myriad issues between these locks and a number of different Z-Wave controllers. Now, Resideo and Honeywell Home have announced confirmed issues as well.

On April 6, 2022, Resideo and Honeywell Home released a Technical Notification to let users know that recent testing discovered a compatibility issue between Schlage lock models BE468, CAM716, and BE469ZP with the newest Honeywell Home TUXEDO and Resideo TUXEDOC keypads. Also incompatible are the ProSeries panels. The ProSeries lineup includes the Honeywell Home PROA7 and PROA7PLUS and the Resideo PROA7C and PROA7PLUSC. The PLUS versions of these panels offer Z-Wave Plus functionality right out of the box, however the NON-PLUS versions require the addition of the PROWIFIZW in order to offer Z-Wave support.

It should be noted that this alert doesn't include other Resideo or Honeywell Z-Wave controller products such as the Lyric, or the L5100-ZWAVE paired with any of the LynxTouch panels. To the best of our knowledge, these products are still compatible with all of the Schlage locks, though we at Alarm Grid still recommend using a Yale or a Kwikset lock instead of a Schlage, even with one of these controllers. Now that the Honeywell Lyric has been discontinued, and the only LynxTouch panel still available is the L5210, Total Connect 2.0 adherents may be hard pressed to find a panel to support a pre-existing Schlage lock.

It is also important to note that not all Schlage locks that were tested were found to be incompatible. The Schlage J-Series, including the JBE109 and JFE109 locks are compatible and both have been added to the compatibility list for the TUXEDO and ProSeries products. You can read the full MyWebTech Technical Notification #71, which includes compatibility documents for both the TUXEDO keypads, and the ProSeries panels.

Have you tried to use a Schlage Lock with a Honeywell, Honeywell Home, or Resideo Z-Wave controller? Were you successful, or no? Leave a note in the comments below with any thoughts or questions about this announcement. We always look forward to hearing from our readers.

Tags: , , , , , , , , , , , , , , ,

3 Comments


Posted By

It's time for ISC West, and all the manufacturers are putting their best foot forward. Resideo now has Release 4 for the ProSeries panels on offer. This update adds Dealer Branding, Customized Voice Descriptors, a WIFI Access Point, 2-Way Voice per Partition, and an Easy Access Help Screen.

Dealer Branding

This can be a hot-button topic for our DIY customers. Many of them don't want dealer branding to mar the look of their touchscreen panel. Release 4 adds the ability to push Dealer Branding to the Honeywell Home PROA7, PROA7PLUS and Resideo PROA7C and PROA7PLUSC. We're not sure how we're going to treat this feature, so stay tuned for more information on this topic.

Customized Voice Descriptors

In the past, Honeywell and now Resideo, and Honeywell Home panels that have supported the voice chime feature were limited to speaking words from a pre-set vocabulary. If a custom voice descriptor was used, then the panel or keypad would just skip that word when speaking the descriptor, as though it didn't exist. With Release 4, this changes for the ProSeries panels. Using either AlarmNet360 or local programming, a custom word descriptor can be entered. It then goes through a text-to-speech process.

If text-to-speech processing occurs on the AlarmNet360 server, then if the custom voice descriptor is typed in by the alarm dealer through AlarmNet360, it will then have to be processed and downloaded to the panel. Then it's ready to be spoken for the zone in question. If the custom voice descriptor is typed in using local panel programming, that means the typed word has to be uploaded, processed, then downloaded again. If processing occurs at the panel, instead of AlarmNet360, then basically the same thing will happen, just in reverse. The point is, some processing and transferring of data must occur, so this kind of change can take a few minutes.

Another very important change comes with this update. In the past, the Device Type has always been spoken as a portion of the zone descriptor (with the exception of Device Type Other). If the Device Type was Window, and you wanted the voice descriptor to be "Front Window" then you only entered "Front" as Zone Descriptor 1 and left Zone Descriptor 2 blank. The panel would automatically say Window as the Device Type. Now, this has changed. The Device Type is no longer being spoken as part of the voice descriptor. So, for my office window, I used Zone Descriptor 1 - Julia, Zone Descriptor 2 - Side, and Device Type Window. However, now, in order to get the panel to actually say "Julia Side Window", I had to make Zone Descriptor 1 - "Julia Side", and Zone Descriptor 2 - "Window". This is a big difference, and may cause some issues, particularly for those with lots of zones. I look for this to possibly change in the near future.

WIFI Access Point

A WIFI Access Point has been added to the ProSeries panels. With this access point the Honeywell Home PROWLTOUCH or Resideo PROWLTOUCHC touchscreen keypad can still be added to a system where no WIFI connection normally exists. This is often an issue seen in second homes, or cabins, where it doesn't make sense to pay for an internet connection when the home is unoccupied. Up to eight (8) secondary keypads can be used per ProSeries panel. Using either the aforementioned touchscreen keypads or the Honeywell Home PROSIXLCDKP push button keypad. As a PROSIX Series Device, the PROSIXLCDKP doesn't require any type of internet connection. It communicates to the panel in the same manner as any PROSIX Series zone does.

Two-Way Voice Per Partition

Two-Way Voice is a feature that allows the central station operator to connect to the location that reported an alarm and either listen in, speak to persons on site, or carry on a two-way conversation. Those, "I've fallen, and I can't get up!" commercials of yesteryear are an early example of two-way voice.

The ProSeries panels have always supported up to four (4) partitions, however, earlier versions did not support two-way voice per partition. When a system with two-way voice enabled reports a burglary or panic signal, the monitoring station receives a special signal. They can then press a command on their end that begins the voice session. Once connected, they can press the 4-Key on their telephone keypad to toggle through up to four (4) touchscreen keypads on the system. Each of those touchscreens can be assigned to any of the partitions that are enabled.

Easy Access Help Screen

In Release 4, a user can go to the hamburger menu icon at the bottom center of the display on either the main panel, or any secondary touchscreen keypad. Once the menu comes up, scroll all the way to the bottom and press Help. A QR Code will be displayed. Scan the QR code with your smartphone or tablet, and then press "Youtube" and you'll be taken to the Resideo and Honeywell Home ProSeries channel on Youtube. You can then browse through the help topics for a video that addresses your issue.


Tags: , , , , , , , , , , , , , ,

3 Comments


Posted By

Final Update: Per a restoral announcement, this issue was resolved by 11:45 AM

Update 10:56 AM: According to Resideo, these notifications are the result of "catch-up" notifications from the outage earlier this week. As the queue for these old messages clears out, the erroneous messages should taper off. In the meantime, actual disarm photos may be delayed.

Original Post: We've had multiple reports this morning of Honeywell Lyric users who are receiving disarm photos from their panels every few minutes. Even users who don't have notifications enabled for disarm photos are being bombarded via the activity log. If you are affected, ignore disarm photo notifications for now.

Initially, it was only Lyric users who were reporting this issue, but now we've received reports from users of the Pro Series panels as well. It seems to be Push Notifications that are being affected. To disable Push Notifications for now, do the following:

  1. Log into Total Connect 2.0.
  2. Go to More > Settings > Notifications.
  3. Tap the toggle for Push Notifications so that it is disabled.

We'll provide more details as they become available.

Tags: , , , , , , , , ,

0 Comments